Raimes Moraes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Raimes Moraes has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Carlos G. Speranza
Departamento Acadêmico de Eletrônica, Instituto Federal de Educação, Ciência e Tecnologia de Santa Catarina, Florianópolis, Brazil
3 shared publications Deborah C. Hizume
GEPEX/LaPEx, Physiotherapy Department, State University of Santa Catarina, Florianópolis, Brazil
3 shared publicationsJoão Fernando Refosco Baggio
BiTS, Italy
3 shared publicationsMaurício C. Tavares
PDI/Contronic Sistemas Automáticos Ltda
3 shared publications- Adriano Mesquita Alencar
Institute of Physics, University of São Paulo, São Paulo, Brazil
2 shared publications - Daniel F. Ponte
Federal Institute of Piaui, 64800-000, Floriano, PI, Brazil
2 shared publications
Latest Publications
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (6) , 1796-1804
Blind Equalization of Lung Crackle Sounds to Compensate Chest Attenuation
Diseased lungs generate adventitious sounds that propagate through the thorax, reaching the surface where they may be heard or recorded. The attenuation imposed to the lung sounds by the thorax depends on the physical characteristics of each patient, hampering the analysis of quantitative indexes measured to assist the diagnosis of cardiorespiratory disorders. This work proposes the application of a blind equalizer (eigenvector algorithm - EVA) to reduce the effects of thorax attenuation on indexes measured from crackle sounds. Computer simulated crackles (acquired on the posterior chest wall after being applied to volunteer's mouth) and actual crackles belonging to a database were equalized. Quantitative indexes were measured from crackles before and after equalization. Comparison of indexes measured from simulated crackles reveals that the equalizer improves the results due to attenuation compensation and removal of Gaussian noise. Effects of equalization on indexes measured from actual crackles were qualitatively assessed. Results point out that blind equalization of crackles recorded on the thorax provides more consistent quantitative indexes to assist the diagnosis of different cardiorespiratory diseases.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (6) , 1796-1804
Blind Equalization of Lung Crackle Sounds to Compensate Chest Attenuation
Diseased lungs generate adventitious sounds that propagate through the thorax, reaching the surface where they may be heard or recorded. The attenuation imposed to the lung sounds by the thorax depends on the physical characteristics of each patient, hampering the analysis of quantitative indexes measured to assist the diagnosis of cardiorespiratory disorders. This work proposes the application of a blind equalizer (eigenvector algorithm - EVA) to reduce the effects of thorax attenuation on indexes measured from crackle sounds. Computer simulated crackles (acquired on the posterior chest wall after being applied to volunteer's mouth) and actual crackles belonging to a database were equalized. Quantitative indexes were measured from crackles before and after equalization. Comparison of indexes measured from simulated crackles reveals that the equalizer improves the results due to attenuation compensation and removal of Gaussian noise. Effects of equalization on indexes measured from actual crackles were qualitatively assessed. Results point out that blind equalization of crackles recorded on the thorax provides more consistent quantitative indexes to assist the diagnosis of different cardiorespiratory diseases.
- 4 June 2019
- Published by Springer Nature
- p. 459-464
Dual Channel Wireless Electronic Stethoscope for Lung Sound Acquisition
- 4 June 2019
- Published by Springer Nature
- p. 459-464
Dual Channel Wireless Electronic Stethoscope for Lung Sound Acquisition
- 1 November 2018
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 102, 21-29
Instantaneous frequency based index to characterize respiratory crackles
- 1 November 2018
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 102, 21-29
Instantaneous frequency based index to characterize respiratory crackles
- 29 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 23 (4) , 1507-1515
Respiratory Waveform Estimation From Multiple Accelerometers: An Optimal Sensor Number and Placement Analysis
Respiratory patterns are commonly measured to monitor and diagnose cardiovascular, metabolic and sleep disorders. Electronic devices such as masks used to record respiratory waveforms usually require medical staff support and obstruct the patients breathing, causing discomfort. New techniques are being investigated to overcome such limitations. An emerging approach involves accelerometers to estimate the respiratory waveform based on chest motion. However, most existing techniques employ a single accelerometer placed on an arbitrary thorax position. The present work investigates the use and optimal placement of multiple accelerometers located on the thorax and the abdomen. The study population is composed of thirty healthy volunteers in three different postures. By means of a custom-made microcontrolled system, data are acquired from an array of ten accelerometers located on predefined positions and a pneumotachograph used as reference. The best sensor locations are identified by optimal linear reconstruction of the reference waveform from the accelerometer data in the minimum mean square error sense. The analysis shows that right-hand side locations contribute more often to optimal respiratory waveform estimates, a sound finding given that the right lung has a larger volume than the left lung. In addition, we show that the respiratory waveform can be blindly extracted from the recorded accelerometer data by means of independent component analysis. In conclusion, linear processing of multiple accelerometers in optimal positions can successfully recover respiratory information in clinical settings where the use of masks may be contraindicated.
- 29 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 23 (4) , 1507-1515
Respiratory Waveform Estimation From Multiple Accelerometers: An Optimal Sensor Number and Placement Analysis
Respiratory patterns are commonly measured to monitor and diagnose cardiovascular, metabolic and sleep disorders. Electronic devices such as masks used to record respiratory waveforms usually require medical staff support and obstruct the patients breathing, causing discomfort. New techniques are being investigated to overcome such limitations. An emerging approach involves accelerometers to estimate the respiratory waveform based on chest motion. However, most existing techniques employ a single accelerometer placed on an arbitrary thorax position. The present work investigates the use and optimal placement of multiple accelerometers located on the thorax and the abdomen. The study population is composed of thirty healthy volunteers in three different postures. By means of a custom-made microcontrolled system, data are acquired from an array of ten accelerometers located on predefined positions and a pneumotachograph used as reference. The best sensor locations are identified by optimal linear reconstruction of the reference waveform from the accelerometer data in the minimum mean square error sense. The analysis shows that right-hand side locations contribute more often to optimal respiratory waveform estimates, a sound finding given that the right lung has a larger volume than the left lung. In addition, we show that the respiratory waveform can be blindly extracted from the recorded accelerometer data by means of independent component analysis. In conclusion, linear processing of multiple accelerometers in optimal positions can successfully recover respiratory information in clinical settings where the use of masks may be contraindicated.
- Open Access
- 1 October 2017
- Published by FapUNIFESP (SciELO) in Research on Biomedical Engineering
- Vol. 33 (4) , 370-374
An automatic gain control circuit to improve ECG acquisition
Keywords Biopotential amplifier; QRS detection; Amplitude normalization; AGC; SNR
- 1 October 2017
- Published by FapUNIFESP (SciELO) in Research on Biomedical Engineering
- Vol. 33 (4) , 370-374
Open AccessAn automatic gain control circuit to improve ECG acquisition
Keywords Biopotential amplifier; QRS detection; Amplitude normalization; AGC; SNR
- 19 February 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 63 (8) , 1983-1990
Equalization of Crackle Sounds to Compensate Thorax Attenuation
Lung sounds recorded on the chest are attenuated by the thorax and thorax-microphone interface. In order to recover waveforms similar to the ones generated within the lungs, this paper equalizes crackle sounds recorded on the chest. From an experiment in which eight subjects (seven men) took part, an estimation of the channel (thorax and thorax-microphone interface) attenuation was obtained to design the equalizer. For that, multiple tones between 100 and 1200 Hz were applied to each subjects' mouth where they were acquired by an electret microphone. These tones were also recorded on the chest using another electret microphone housed into an acoustic coupler. The attenuation of each tone was calculated by the power ratio between the one measured on the chest and that measured at the mouth. After obtaining the average attenuation curve from the volunteers, a discrete-time equalizer was designed and applied to crackles acquired from 30 patients with fibrosis, congestive heart failure, and pneumonia. The maximum frequency and two cycle duration indices measured from these crackles were modified by the equalization. The obtained results show that the equalizer improves the extraction of features from the crackles sounds. Equalization of crackles may contribute to better characterize the different diseases.
- 19 February 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 63 (8) , 1983-1990
Equalization of Crackle Sounds to Compensate Thorax Attenuation
Lung sounds recorded on the chest are attenuated by the thorax and thorax-microphone interface. In order to recover waveforms similar to the ones generated within the lungs, this paper equalizes crackle sounds recorded on the chest. From an experiment in which eight subjects (seven men) took part, an estimation of the channel (thorax and thorax-microphone interface) attenuation was obtained to design the equalizer. For that, multiple tones between 100 and 1200 Hz were applied to each subjects' mouth where they were acquired by an electret microphone. These tones were also recorded on the chest using another electret microphone housed into an acoustic coupler. The attenuation of each tone was calculated by the power ratio between the one measured on the chest and that measured at the mouth. After obtaining the average attenuation curve from the volunteers, a discrete-time equalizer was designed and applied to crackles acquired from 30 patients with fibrosis, congestive heart failure, and pneumonia. The maximum frequency and two cycle duration indices measured from these crackles were modified by the equalization. The obtained results show that the equalizer improves the extraction of features from the crackles sounds. Equalization of crackles may contribute to better characterize the different diseases.
- 25 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 60 (11) , 3176-3184
Validation of the Inverse Pulse Wave Transit Time Series as Surrogate of Systolic Blood Pressure in MVAR Modeling
Short-term cardiovascular regulation mediated by the sympathetic and parasympathetic branches of the autonomic nervous system has been investigated by multivariate autoregressive (MVAR) modeling, providing insightful analysis. MVAR models employ, as inputs, heart rate (HR), systolic blood pressure (SBP) and respiratory waveforms. ECG (from which HR series is obtained) and respiratory flow waveform (RFW) can be easily sampled from the patients. Nevertheless, the available methods for acquisition of beat-to-beat SBP measurements during exams hamper the wider use of MVAR models in clinical research. Recent studies show an inverse correlation between pulse wave transit time (PWTT) series and SBP fluctuations. PWTT is the time interval between the ECG R-wave peak and photoplethysmography waveform (PPG) base point within the same cardiac cycle. This study investigates the feasibility of using inverse PWTT (IPWTT) series as an alternative input to SBP for MVAR modeling of the cardiovascular regulation. For that, HR, RFW, and IPWTT series acquired from volunteers during postural changes and autonomic blockade were used as input of MVAR models. Obtained results show that IPWTT series can be used as input of MVAR models, replacing SBP measurements in order to overcome practical difficulties related to the continuous sampling of the SBP during clinical exams.
- 25 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 60 (11) , 3176-3184
Validation of the Inverse Pulse Wave Transit Time Series as Surrogate of Systolic Blood Pressure in MVAR Modeling
Short-term cardiovascular regulation mediated by the sympathetic and parasympathetic branches of the autonomic nervous system has been investigated by multivariate autoregressive (MVAR) modeling, providing insightful analysis. MVAR models employ, as inputs, heart rate (HR), systolic blood pressure (SBP) and respiratory waveforms. ECG (from which HR series is obtained) and respiratory flow waveform (RFW) can be easily sampled from the patients. Nevertheless, the available methods for acquisition of beat-to-beat SBP measurements during exams hamper the wider use of MVAR models in clinical research. Recent studies show an inverse correlation between pulse wave transit time (PWTT) series and SBP fluctuations. PWTT is the time interval between the ECG R-wave peak and photoplethysmography waveform (PPG) base point within the same cardiac cycle. This study investigates the feasibility of using inverse PWTT (IPWTT) series as an alternative input to SBP for MVAR modeling of the cardiovascular regulation. For that, HR, RFW, and IPWTT series acquired from volunteers during postural changes and autonomic blockade were used as input of MVAR models. Obtained results show that IPWTT series can be used as input of MVAR models, replacing SBP measurements in order to overcome practical difficulties related to the continuous sampling of the SBP during clinical exams.
- 11 July 2012
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 35 (4) , 448-456
Characterization of crackles from patients with fibrosis, heart failure and pneumonia
The spectral analysis of crackles sounds has been carried out based on the assumption that they are stationary signals, and the majority of the work on the crackles was accomplished before the publication of the Computerized Respiratory Sound Analysis (CORSA) guidelines. This works characterizes crackles acquired from patients with fibrosis, heart failure, and pneumonia, breathing at a constant rate, with a system developed according to the CORSA guidelines. Their maximum frequency was obtained by applying discrete pseudo Wigner-Ville distribution, suitable for non-stationary signals, and an objective method to estimate the maximum frequency, the modified geometric method. The effects of the breathing rate and the tidal volume on the spectra of the crackles were also investigated. The role of the high-pass filter cutoff frequency of the acquisition system on the characteristics of the acquired crackles was also assessed in this present study. Higher high-pass filter cutoff frequency allows for higher amplification which modifies the maximum frequency and the 2CD index. It is shown that the crackles acquired according to the CORSA guidelines have higher frequencies and shorter 2CD indexes than those previously reported, highlighting the need for the standardization and detailed report of the acquisition setup when quantifying lung sounds. The results pointed out that the maximum frequency and the 2CD indexes may allow crackles generated by fibrosis to be distinguished from the ones generated by the heart failure and pneumonia. It is not possible, however, by means of these two indexes, to differentiate between pneumonia and heart failure crackles.
- 11 July 2012
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 35 (4) , 448-456
Characterization of crackles from patients with fibrosis, heart failure and pneumonia
The spectral analysis of crackles sounds has been carried out based on the assumption that they are stationary signals, and the majority of the work on the crackles was accomplished before the publication of the Computerized Respiratory Sound Analysis (CORSA) guidelines. This works characterizes crackles acquired from patients with fibrosis, heart failure, and pneumonia, breathing at a constant rate, with a system developed according to the CORSA guidelines. Their maximum frequency was obtained by applying discrete pseudo Wigner-Ville distribution, suitable for non-stationary signals, and an objective method to estimate the maximum frequency, the modified geometric method. The effects of the breathing rate and the tidal volume on the spectra of the crackles were also investigated. The role of the high-pass filter cutoff frequency of the acquisition system on the characteristics of the acquired crackles was also assessed in this present study. Higher high-pass filter cutoff frequency allows for higher amplification which modifies the maximum frequency and the 2CD index. It is shown that the crackles acquired according to the CORSA guidelines have higher frequencies and shorter 2CD indexes than those previously reported, highlighting the need for the standardization and detailed report of the acquisition setup when quantifying lung sounds. The results pointed out that the maximum frequency and the 2CD indexes may allow crackles generated by fibrosis to be distinguished from the ones generated by the heart failure and pneumonia. It is not possible, however, by means of these two indexes, to differentiate between pneumonia and heart failure crackles.
- 1 January 2012
- Published by INSTICC
- p. 232-237
NONINVASIVE CARDIOVASCULAR SYSTEM IDENTIFICATION USING PULSE WAVE TRANSIT TIME
- 1 January 2012
- Published by INSTICC
- p. 232-237
NONINVASIVE CARDIOVASCULAR SYSTEM IDENTIFICATION USING PULSE WAVE TRANSIT TIME
- 1 January 2011
- Published by INSTICC
- p. 363-367
WIRELESS DEVICE FOR NONINVASIVE RECORDINGS OF CARDIO-RESPIRATORY SIGNALS
- 1 January 2011
- Published by INSTICC
- p. 363-367
WIRELESS DEVICE FOR NONINVASIVE RECORDINGS OF CARDIO-RESPIRATORY SIGNALS