MÖMustafa Özakça

Mustafa Özakça

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mustafa Özakça has a total of 73 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effect of Void Geometry on the Structural Behavior of Biaxial Voided Slabs: A Nonlinear Finite Element Analysis

    by Nursel Kütük, Mustafa Özakça, Esra Eylem Karataş

    This study examines the influence of void geometry on the structural performance of biaxial voided reinforced concrete slabs using nonlinear finite element (FE) analysis in ANSYS Workbench 2022 R1. Seven void configurations—spherical, cubic, elliptical, ellipsoidal, capsule, biaxial capsule, and donut—were evaluated under identical material properties, loading, boundary conditions, and equivalent total concrete volume. This approach ensures that performance differences arise from geometric material distribution rather than increased material quantity. This controlled framework enables the isolated assessment of geometric effects on slab stiffness, load capacity, and deflection behavior. In addition, a solid slab with equivalent concrete volume, achieved by reducing its thickness, was analyzed as a reference case to evaluate the structural benefits of void incorporation. All voided slabs were subjected to incremental loading up to a maximum load of 1500 kN and maintained adequate structural performance throughout the loading process. Among the investigated configurations, the ellipsoidal and elliptical void geometries exhibited the most favorable response, characterized by the smallest midspan deflections of 19.79 mm and 20.38 mm, respectively. These results confirm that void geometry plays a significant role in governing slab stiffness and structural efficiency. In contrast, the solid slab with equivalent concrete volume failed at a load of 895 kN and exhibited the largest midspan deflection of 52.93 mm, indicating lower stiffness and reduced load-carrying capacity compared to the voided configurations. Overall, elongated void shapes—particularly ellipsoidal, elliptical, capsule, and biaxial capsule—provide an effective balance between stiffness and strength, offering practical guidance for the design of lightweight, material-efficient biaxial voided slab systems.

  • Open Access

    Simplified Post-Fire Structural Performance of Biaxial Voided Reinforced Concrete Slabs: Influence of Void Geometry

    by Nursel Kütük, Mustafa Özakça

    Reinforced concrete (RC) slabs with internal voids are increasingly used to improve material efficiency; however, their residual structural performance after fire exposure remains insufficiently understood. This study presents a numerical investigation of RC slabs with different void geometries using a three-dimensional nonlinear Finite Element (FE) model. A sequential thermal–structural approach was adopted, in which fire exposure was simulated through transient thermal analysis, and the resulting spatial distribution of maximum temperatures was used to assign residual material properties to each FE based on its local peak temperature, followed by structural analysis under ambient conditions. A parametric study was conducted on seven slab configurations, including two solid slabs and five voided slabs with spherical, elliptical, ellipsoidal, capsule, and biaxial capsule geometries. To ensure a consistent evaluation, two reference solid slabs were considered: a 230 mm thick slab to enable comparison under identical geometric conditions, and a 160 mm thick slab representing equivalent concrete volume to assess material efficiency. Fire exposure was applied according to the ISO 834 standard fire curve for durations of 30, 60, and 90 min. The results indicate that voided slabs exhibit higher deflections than the solid slab of identical thickness due to reduced stiffness, while achieving comparable performance relative to the solid slab with equivalent concrete volume. These findings highlight the trade-off between structural stiffness and material efficiency under increasing fire exposure time.


  • Open Access

    Effects of Area of Walls, Internal Corridors, and Stairs on the Built-Up Area of Houses

    by Hassan Faisal Jaafar, Abdulbaqi Ghazi, Ali I. Sabur, Mustafa Özakça

    الخلاصة: تتطلب عملية تصميم المنزل تطوير تصورات أولية لمساحة العديد من العناصر والمساحات ، والتي غالبًا لا يتم حسابها فعليًا ، بما في ذلك مساحة الدرج والممرات الداخلية والجدران ، والتي تستهلك مساحة كبيرة جدًا. الطريقة الاستنتاجية لتحليل مجموعة من العينات للوصول إلى نتيجة موحدة تقريبية. حيث تم تحديد النسبة التقريبية لمساحة السلالم والممرات الداخلية (17٪) بينما كانت النسبة التقريبية للجدران (17٪) وبالتالي فإن النسبة الإجمالية (34٪) من الممرات والسلالم والجدران. من المساحة المبنية.وفقًا لذلك ، من خلال هذه النسبة ، يمكن تطوير تصور أولي لمساحة المساحة المتبقية في المنزل السكني. لاحظ أن وجود مثل هذه النسبة لدى المصمم المعماري سيقلل من العديد من الاختلافات بين المهندس المعماري والعميل من ناحية ، وكذلك يعطي تصورًا أوليًا للمساحات المحتملة من ناحية أخرى

  • Open Access

    Structural Behavior of Full-Scale Novel Hybrid Layered Concrete Slabs Reinforced with CFRP and Steel Grids under Impact Load

    by Ahmed Abbas Ghali Abu Altemen, Mu’taz Kadhim Medhlom, Mustafa Özakça

    Reinforced concrete two-way slabs are important elements in the construction field, and their impact response under drop-weight impact is a complex mechanical issue that can cause the collapse of heavy structures. Previous research has documented the analysis of conventional steel-reinforced concrete slabs under impact loads. However, the investigation of layered hybrid concrete composite flat solid slabs reinforced with carbon-fiber-reinforced polymer (CFRP) rebars is an innovative subject. This paper examines the structural behavior of layered novel hybrid concrete composite flat solid slabs with a combination of reactive powder concrete (RPC) in the top layer and normal concrete (NC) in the bottom layer, reinforced with internal CFRP or traditional steel bars in the tension zone, under an impact load test. For this purpose, ten full-scale square flat solid slab samples with a 1550 mm length and a 150 mm depth were fabricated and divided into eight layered hybrid concrete samples with 50% RPC and 50% NC and two samples cast with NC only. The impact tests were carried out using a hardened steel cylindroconical impactor (projectile) with a height of 650 mm and a diameter of 200 mm, a flat nose diameter of 90 mm, and a total mass of 150 kg released from two different heights of 5 and 7 m. The variables considered were the types and ratios of reinforcement, as well as the free-drop weight and height. The experimental results obtained showed that layered RPC flat solid slabs are superior in resisting and sustaining impact forces and also have fewer scattered parts when compared to NC flat solid slabs. Additionally, the flat solid slab samples reinforced with CFRP bar grids were overall more resistant to impact loads, by an average of 19%, compared to flat solid slabs with steel bars and showed lower deflection, by an average of 10%, compared to the other flat solid slabs.


  • Open Access

    Recent Literature on Steel Fiber Role in Resistance Improvement of Fibrous Concrete to Repeated Impacts

    by Mustafa Ozakca, Raad A. Al-Ameri, Esra Eylem Karataş, M. Tolga Göğüş, A. Hamza Tanrıkulu

    Concrete is a brittle material when subjected to design and accidental impact loads, which are expected along the life span of the structure. To improve the impact performance of concrete, steel fibers are used as short discrete material reinforcing elements. Among the available impact test, the ACI 544-2R repeated impact test is considered as the simplest and cheapest test procedure that needs no sophisticated sensors and costly techniques, which is used as a qualitative tool to evaluate the impact of fibrous concrete. This article introduces a state-of-the-art literature review of the repeated impact performance of steel fiber-reinforced concrete. Rich literature of different steel fiber-reinforced concrete types is reviewed and the effect of steel fibers on the retained cracking and failure impact numbers is highlighted. The sole effects of the geometrical parameters of steel fibers were analyzed in addition to fiber content. Based on the reviewed literature works, it can be summarized that increasing the fiber content increases the bond strength, and using longer fibers affords deeper anchorage lengths inside the cement paste across cracks, which postpone their widening and improves the impact resistance in terms of recorded cracking and failure numbers.


  • Open Access

    Drop-Weight Impact Tests on Engineered Cementitious Composites heated to 500 oC

    by Raad A. Al-Ameri, Mustafa Özakça, Esra Eylem Karataş, M Tolga Göğüş, A. Hamza Tanrıkulu

    Despite that concrete is a fire-resisting construction material, its microstructure suffers significant chemical and physical changes when subjected to temperatures higher than 400 oC. Therefore, the combined effect of unexpected impacts and fire can lead to the collapse of the structure. To evaluate this combined effect, an experimental program was directed in this study using the ACI 544-2R repeated impact test method. Shallow cylindrical specimens with 150 mm diameter and 64 mm depth were prepared to evaluate the cracking and failure impact strengths of normal strength concrete (NC) and engineered cementitious composites (ECC). The ECC mixture was reinforced with 2% of polypropylene fibers. In addition to the impact strength, the compressive and flexural strengths of NC and ECC mixtures were also investigated. The impact, compressive and flexural tests were performed on unheated specimens and others heated to 500 oC to evaluate the residual strengths of NC and ECC mixtures. The results showed that before heating, ECC exhibited a failure impact performance that is approximately 6 times more ductile than that of NC, where the retained failure impact numbers of NC and ECC were 57 and 259 blows, respectively. However, both mixtures lost approximately 95% of their impact strengths after exposure to 500 oC.

  • Open Access

    Residual Impact Performance of ECC Subjected to Sub-High Temperatures

    by Raad A. Al-Ameri, Sallal Rashid Abid, Gunasekaran Murali, Sajjad H. Ali, Mustafa Özakça, Nikolay Ivanovich Vatin

    Despite the fact that the mechanical properties of Engineered Cementitious Composites (ECC) after high-temperature exposure are well investigated in the literature, the repeated impact response of ECC is not yet explored. Aiming to evaluate the residual impact response of ECC subjected to sub-high temperatures under repeated drop weight blows, the ACI 544-2R repeated impact test was utilized in this study. Disk impact specimens (150 mm diameter and 64 mm thickness) were prepared from the M45 ECC mixture but using polypropylene fibers, while similar 100 mm cube specimens and 100 × 100 × 400 mm prism specimens were used to evaluate the compressive and flexural strengths. The specimens were all cast, cured, heated, cooled, and tested under the same conditions and at the same age. The specimens were subjected to three temperatures of 100, 200 and 300 °C, while a group of specimens was tested without heating as a reference group. The test results showed that heating to 100 and 200 °C did not affect the impact resistance noticeably, where the retained cracking and failure impact numbers and ductility were higher or slightly lower than those of unheated specimens. On the other hand, exposure to 300 °C led to a serious deterioration in the impact resistance and ductility. The retained failure impact numbers after exposure to 100, 200, and 300 °C were 313, 257, and 45, respectively, while that of the reference specimens was 259. The results also revealed that the impact resistance at this range of temperature showed a degree of dependency on the compressive strength behavior with temperature.


  • Open Access

    Mechanical and Impact Properties of Engineered Cementitious Composites Reinforced with PP Fibers at Elevated Temperatures

    by Raad A. Al-Ameri, Sallal Rashid Abid, Mustafa Özakça

    The repeated impact performance of engineered cementitious composites (ECCs) is not well explored yet, especially after exposure to severe conditions, such as accidental fires. An experimental study was conducted to evaluate the degradation of strength and repeated impact capacity of ECCs reinforced with Polypropylene fibers after high temperature exposure. Compressive strength and flexural strength were tested using cube and beam specimens, while disk specimens were used to conduct repeated impact tests according to the ACI 544-2R procedure. Reference specimens were tested at room temperature, while three other groups were tested after heating to 200 °C, 400 °C and 600 °C and naturally cooled to room temperature. The test results indicated that the reference ECC specimens exhibited a much higher failure impact resistance compared to normal concrete specimens, which was associated with a ductile failure showing a central surface fracture zone and fine surface multi-cracking under repeated impacts. This behavior was also recorded for specimens subjected to 200 °C, while the exposure to 400 °C and 600 °C significantly deteriorated the impact resistance and ductility of ECCs. The recorded failure impact numbers decreased from 259 before heating to 257, 24 and 10 after exposure to 200 °C, 400 °C and 600 °C, respectively. However, after exposure to all temperature levels, the failure impact records of ECCs kept at least four times higher than their corresponding normal concrete ones.


  • Open Access

    Residual Repeated Impact Strength of Concrete Exposed to Elevated Temperatures

    by Raad A. Al-Ameri, Sallal R. Abid, G. Murali, Sajjad H. Ali, Mustafa Özakça

    Portland cement concrete is known to have good fire resistance; however, its strength would be degraded after exposure to the temperatures of fire. Repeated low-velocity impacts are a type of probable accidental load in many types of structures. Although there is a rich body of literature on the residual mechanical properties of concrete after high temperature exposure, the residual repeated impact performance of concrete has still not been well explored. For this purpose, an experimental study was conducted in this work to evaluate the effect of high temperatures on the repeated impact strength of normal strength concrete. Seven identical concrete patches with six disc specimens each were cast and tested using the ACI 544-2R repeated impact setup at ambient temperature and after exposure to 100, 200, 300, 400, 500 and 500 °C. Similarly, six cubes and six prisms from each patch were used to evaluate the residual compressive and flexural strengths at the same conditions. Additionally, the scattering of the impact strength results was examined using three methods of the Weibull distribution, and the results are presented in terms of reliability. The test results show that the cracking and failure impact numbers of specimens heated to 100 °C reduced slightly by only 2.4 and 3.5%, respectively, while heating to higher temperatures deteriorated the impact resistance much faster than the compressive and flexural strengths. The percentage reduction in impact resistance at 600 °C was generally higher than 96%. It was also found that the deduction trend of the impact strength with temperature is more related to that of the flexural strength than the compressive strength. The test results also show that, within the limits of the adopted concrete type and conducted tests, the strength reduction after high temperature exposure is related to the percentage weight loss.


  • Open Access

    Experimental Investigation on the Effect of Steel Fibers on the Flexural Behavior and Ductility of High‐Strength Concrete Hollow Beams

    by Ahmmad Abbass, Sallal Abid, Mustafa Özakça

    In this study, an experimental work was directed toward comparing the flexural behavior of solid and hollow steel fiber‐reinforced concrete beams. For this purpose, eight square cross‐sectional beam specimens, four solid and four hollow, were prepared. One concrete mixture with four different steel fiber contents of 0, 0.5, 1.0, and 1.5% were used. The side length of the central square hole was 80 mm, whereas the cross‐sectional side length was 150 mm. All beams were tested under four‐point monotonic loading until failure. In addition to the solid and hollow beams, cylinders were cast to evaluate the compressive strength, splitting tensile strength, and modulus of elasticity, whereas prisms were used to conduct the fracture test. The test results showed that all fibrous beams failed in flexure, whereas those without fiber exhibited flexural‐shear failure. In general, the flexural behavior of fibrous‐beams was superior to that of beams without fiber. The hollow beams with fiber contents of 0, 0.5, and 1.0% were observed to withstand lower loads at cracking, yielding, and peak stages compared with their corresponding solid beams; this was not the case for the 1.5% fiber hollow beam, which exhibited a higher peak load than its corresponding solid beam. Although all eight beams exhibited ductility indices higher than 3.7, hollow beams exhibited better ductility than solid beams, showing higher ductility index values.