TKThomas Klotzbuecher

Thomas Klotzbuecher

*This is an algorithmically generated author record based on publicly available information.

Thomas Klotzbuecher has a total of 87 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • MEMS-based non-dispersive mid-infrared sensor for condition monitoring of lubricants

    by Kai-Vincent Mettang, Thomas P. Burg, Stefan Schmitt, Thomas Klotzbücher


  • In vivo continuous glucose monitoring using a chip based near infrared sensor

    by L. Ben Mohammadi, S. Sigloch, I. Frese, K. Welzel, M. Göddel, T. Klotzbücher

    Diabetes is a serious health condition considered to be one of the major healthcare epidemics of modern era. An effective treatment of this disease can be only achieved by reliable continuous information on blood glucose levels. In this work we present a minimally invasive, chip-based near infrared (NIR) sensor, combined with microdialysis, for continuous glucose monitoring (CGM). The sensor principle is based on difference absorption spectroscopy in the 1st overtone band of the near infrared spectrum. The device features a multi-emitter LED and InGaAs-Photodiodes, which are located on a single electronic board (non-disposable part), connected to a personal computer via Bluetooth. The disposable part consists of a chip containing the fluidic connections for microdialysis, two fluidic channels acting as optical transmission cells and total internally reflecting mirrors for in- and out-coupling of the LED light to the chip and to the detectors. The sensor is combined with an intraveneous microdialysis to separate the glucose from the cells and proteins in the blood and operates without any chemical consumption. In vitro measurements showed a linear relationship between glucose concentration and the integrated difference signal with a coefficient of determination of 99 % in the relevant physiological concentration range from 0 to 400 mg/dl. In vivo measurements on 10 patients showed that the NIR-CGM sensor data reflects the blood reference values adequately, if a proper calibration and signal drift compensation is applied. The MARE (mean absolute relative error) value taken over all patient data is 13.8 %. The best achieved MARE value is at 4.8 %, whereas the worst is 25.8 %, with a standard deviation of 5.5 %. © (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only


  • In vivo evaluation of a chip based near infrared sensor for continuous glucose monitoring

    by Lhoucine Ben Mohammadi, Thomas Klotzbuecher, Susanne Sigloch, Knut Welzel, Michael Göddel, Thomas R. Pieber, Lukas Schaupp


  • A minimally invasive chip based near infrared sensor for continuous glucose monitoring

    by L. Ben Mohammadi, S. Sigloch, I. Frese, V. Stein, K. Welzel, F. Schmitz, T. Klotzbücher

    Assessment of glycaemia in diabetes is crucially important for prevention of both, acute and long term complications. Continuous glucose monitoring (CGM) is certainly the most appropriate way for optimizing the glycaemic control, since it prevents or delays the progression of complications associated with hypo- or hyperglycaemic events, reducing morbidity, mortality, and overall costs in health care systems. In this paper we describe the concept and first in vitro results of a minimally invasive, chip-based NIR-Sensor for continuous glucose monitoring. The sensor concept is based on difference infrared absorption spectroscopy, which was evaluated within laboratory measurements of D+-Glucose dissolved in water. The laboratory measurements revealed a linear relationship between glucose concentration and the integrated difference spectroscopy signal with a coefficient of determination of 99.6% in the concentration range of 0- 500 mg/dL. Suitable wavelength bands were identified in which the correlation is preserved and commercial light sources are available for realisation of a spectrometer-less, integrated NIR-sensor. In the designed sensor the component area (non-disposable) is separated from the detection area (disposable, low-cost). The disposable part of the sensor is fluidically connected to a micro-dialyses needle, accessing glucose subcutaneously via the ISF (interstitial fluid) or intravascularly. The non-disposable part contains all the optical elements, like LED´s and photo-detectors. The in- and out-coupling of the optical signal is achieved across the plane of the chip by using total internal reflection on mirrors integrated into the fluidic chip. The glucose is continuously measured by considering the difference signals of light at the corresponding wavelengths, as a function of time or in defined intervals if the light sources are modulated. The in-vitro measurements show an absolute error of about 5 mg/dL with a relative error of 5% for glucose concentrations larger than 50 mg/dL and about 12 % in the hypoglycemic range (<50 mg /dL).


  • Nano-structured surfaces by laser interference lithography and fs-laser direct writing as substrates for surface-enhanced Raman spectroscopy

    by L. Ben Mohammadi, N. Hundertmark, F. Kullmann, F. Fleissner, T. Klotzbücher

    Nano-structured surfaces were generated by laser interference lithography and femtosecond-laser direct writing of photo resists that subsequently were metallized by electroless plating or sputter deposition of silver. Laser lithography was performed with a 405 nm coherent diode laser in AZ9260, using two-beam interference with double illumination by 90° rotating of the substrate, leading to 2D periodic surface patterns with smallest features of the order of 200 nm. With fs-laser direct writing using a Ti-sapphire oscillator of 800 nm and 15 fs pulse length, feature sizes down to 100 nm were realized in SU8, even with aspect ratios much larger than 1. Metallization with electroless plating delivered either grainy silver coatings with a grain size around 100 nm or needle-like silver coatings with a needle length around 100 nm and a width of around 10 nm. The metallized substrates were exposed to aqueous solutions of Rhodamine 6G (Rh6G) of different concentrations and the corresponding Raman signals were recorded with a Raman micro-probe spectrometer. The nano-structured surfaces lead to formation of Raman bands attributable to Rh6G. In case of the grainy silver coatings, surfaces without nano-structures did not show Raman activity, indicating that grating-coupled surface plasmons play the dominant role for Raman enhancement. In case of substrates coated with the needle-shaped silver crystallites, Raman activity was also seen in regions without laser-generated nano-structures, indicating that localized particle plasmons play the dominant role for Raman enhancement. A comparison with Raman spectra measured with conventional Raman spectrometer showed that the enhancement factor achieved by the laser-generated nano-structures themself, is of the order of 6×104. Raman intensity as a function of Rh6G concentration revealed a regular behaviour, as expected from a Langmuir isotherm.


  • Three‐Dimensional Bichiral Plasmonic Crystals Fabricated by Direct Laser Writing and Electroless Silver Plating

    by André Radke, Timo Gissibl, Thomas Klotzbücher, Paul V. Braun, Harald Giessen


  • Fabrication of dielectric and metallo-dielectric 3D nanostructures by direct laser writing and electroless plating

    by André Radke, Frank Wolff, Harald Giessen, Thomas Klotzbücher

    Direct laser writing via two-photon absorption allows the fabrication of three-dimensional dielectric structures with submicron resolution by tightly focusing ultrashort laser pulses into a photo-sensitive material with a high-resolution microscope objective and scanning the laser focus relative to the material. Woodpile photonic crystals fabricated with this method show a characteristic dip in transmission at near-infrared wavelengths. The spectral position of this transmission dip scales with the grating period of the fabricated crystals. Metallo-dielectric structures can be obtained by first fabricating dielectric templates with direct laser writing and subsequently coating the templates with a thin conformal metal film by electroless plating. Contiguous and conducting silver films can be deposited even on convoluted 3D geometries.


  • Active integrated components for fluid control in automatic analytical chip-based systems

    by F. von Germar, J. Claußen, R. Gransee, E. Schaeffer, L. B. Mohammadi, T. Klotzbücher

    A robust optical sensor for liquid control in fluidic channels is reported. The sensor operates on light intensity modulation resulting from alteration of total internal reflection into partial reflection. When a liquid guided in a channel covers an integrated prism, the total internal reflection is changed into a partial reflection, resulting in an intensity modulation of the reflected light. The set-up comprises a fibre which is built in a coupler unit with integrated LED and photodiode as well as a prism micro-machined directly into a micro-fluidic polymeric channel by laser ablation. The Prism is of 45-90-45° type with a dimension of 0.5 mm × 1 mm × 2 mm. In this design the radiation of the LED light source is transmitted and collected from the prism by a 50:50 fibre coupler by means of total or partial internal reflection. The sensor was characterised by filling alternately the channel with water and air. The influence of stray light onto the sensor signal was tested by applying a strong uncollimated illumination of the channel. Only a small increase in the output signal level in the presence of air but a strong increase in case of the presence of water could be detected.

  • Integrated optical sensor for liquid control in micro-fluidic channel systems

    by Frithjof V. Germar, Thomas Klotzbücher, Lhoucine Ben Mohammadi, Jan Claussen

    A robust optical sensor for liquid control in fluidic channels is reported. The sensor operates on light intensity modulation resulting from alteration of total internal reflection into partial reflection. When a liquid guided in a channel covers an integrated prism, the total internal reflection is changed into a partial reflection, resulting in an intensity modulation of the reflected light. The set-up comprises a fibre which is built in a coupler unit with integrated LED and photodiode as well as a prism micro-machined directly into a micro-fluidic polymeric channel by laser ablation. The Prism is of 45-90-45° type with a dimension of 0.5 mm × 1 mm × 2 mm. In this design the radiation of the LED light source is transmitted and collected from the prism by a 50:50 fibre coupler by means of total or partial internal reflection. The sensor was characterised by filling alternately the channel with water and air. The signal level for the liquid in contact with the prism was determined to be 222 mV while the signal level of the air filled channel was 336 mV. The influence of stray light onto the sensor signal was tested by applying a strong uncollimated illumination of the channel. Only a small increase in the output signal level in the presence of air but a strong increase in case of the presence of water could be detected. However, the discrimination between air and liquid was still possible sufficiently (290 mV for liquid, 340 mV for air). The sensor was also demonstrated to be operated as a micro-refractometer.