Ramin Alipour
Research Subjects
Ramin Alipour has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
M. Ghoranneviss
Plasma Physics Research Center, Science and Research Branch, Islamic Azad University, Tehran, Iran
6 shared publicationsA. Jafari
Islamic Azad University
5 shared publications- Mahmood Ghoranneviss
Plasma Physics Research Center, Science and Research Branch, Islamic Azad University, Tehran, Iran
5 shared publications - Sakineh Meshkani
Plasma Physics Research Center, Science and Research Branch, Islamic Azad University, Tehran, Iran
3 shared publications A. Salar Elahi
Plasma Physics Research Center, Science and Research Branch, Islamic Azad University , Tehran, Iran
2 shared publicationsAhmad Salar Elahi
Plasma Physics Research Center, Science and Research Branch, Islamic Azad University
2 shared publications
Latest Publications
- 30 April 2018
- Published by Springer Nature in The European Physical Journal D
- Vol. 72 (4) , 75
Magnetic evaluation of hydrogen pressures changes on MHD fluctuations in IR-T1 tokamak plasma
- 30 April 2018
- Published by Springer Nature in The European Physical Journal D
- Vol. 72 (4) , 75
Magnetic evaluation of hydrogen pressures changes on MHD fluctuations in IR-T1 tokamak plasma
- Open Access
- 1 November 2017
- Published by AIP Publishing in AIP Advances
- Vol. 7 (11)
First investigation on plasma impurities of the IR-T1 tokamak
One of the best ways to get information about plasma and interactions within it, is the study on visible light emitted from plasma. Detection of the emission spectrum from plasma leads to identify the spectral lines of ions and impurities inside the plasma and measurement of all related parameters to ion flux such as velocity and temperature. The first measurement of impurities into the IR-T1 tokamak plasma is done by spectroscopic technique. The CCD-based spectrometer device with the wavelength range of 400-550 nm is used to detection the spectrum emitted from the plasma. The impurities into the plasma in the intended wavelength range are identified. Furthermore, the Doppler broadening of the most intense peaks of impurities and their temperatures are measured. The methods in this paper can be used on all fusion devices.
- 1 November 2017
- Published by AIP Publishing in AIP Advances
- Vol. 7 (11)
Open AccessFirst investigation on plasma impurities of the IR-T1 tokamak
One of the best ways to get information about plasma and interactions within it, is the study on visible light emitted from plasma. Detection of the emission spectrum from plasma leads to identify the spectral lines of ions and impurities inside the plasma and measurement of all related parameters to ion flux such as velocity and temperature. The first measurement of impurities into the IR-T1 tokamak plasma is done by spectroscopic technique. The CCD-based spectrometer device with the wavelength range of 400-550 nm is used to detection the spectrum emitted from the plasma. The impurities into the plasma in the intended wavelength range are identified. Furthermore, the Doppler broadening of the most intense peaks of impurities and their temperatures are measured. The methods in this paper can be used on all fusion devices.
- 26 October 2017
- Published by Springer Nature in Brazilian Journal of Physics
- Vol. 47 (6) , 567-574
Investigation on the Hard X-ray Radiations of the IR-T1 Tokamak Plasma: Electric and Magnetic Perspectives
- 26 October 2017
- Published by Springer Nature in Brazilian Journal of Physics
- Vol. 47 (6) , 567-574
Investigation on the Hard X-ray Radiations of the IR-T1 Tokamak Plasma: Electric and Magnetic Perspectives
- 5 September 2017
- Published by Springer Nature in The European Physical Journal D
- Vol. 71 (9) , 228
Effects of the location of a biased limiter on turbulent transport in the IR-T1 tokamak plasma
- 5 September 2017
- Published by Springer Nature in The European Physical Journal D
- Vol. 71 (9) , 228
Effects of the location of a biased limiter on turbulent transport in the IR-T1 tokamak plasma
- 1 September 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (9) , 093516
Design and fabrication of a new compound probe for plasma flux measurement in IR-T1 tokamak
A new compound probe is designed, built, and installed on an IR-T1 tokamak to flow measurements in the plasma edge region. The first results of using this probe on the IR-T1 tokamak are presented. The plasma parameters such as plasma current, loop voltage, floating potential, ion and electron saturation currents, electron temperature, plasma potential, and plasma flow velocities are measured in this work. The results show that the electron temperature and the plasma potential in the edge area are 14 eV and 44 V, respectively. The results indicate that the mean value of a parallel Mach number is 0.5 while the mean value of a perpendicular Mach number is almost zero. The large parallel flow velocity (about 17 km/s) and the negligible perpendicular flow velocity are also seen in this work. The most important advantage of using this compound probe is that it can not only save space and vacuum ports but also measure more physical quantities at the same time, contributing to further physical analysis.
- 1 September 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (9) , 093516
Design and fabrication of a new compound probe for plasma flux measurement in IR-T1 tokamak
A new compound probe is designed, built, and installed on an IR-T1 tokamak to flow measurements in the plasma edge region. The first results of using this probe on the IR-T1 tokamak are presented. The plasma parameters such as plasma current, loop voltage, floating potential, ion and electron saturation currents, electron temperature, plasma potential, and plasma flow velocities are measured in this work. The results show that the electron temperature and the plasma potential in the edge area are 14 eV and 44 V, respectively. The results indicate that the mean value of a parallel Mach number is 0.5 while the mean value of a perpendicular Mach number is almost zero. The large parallel flow velocity (about 17 km/s) and the negligible perpendicular flow velocity are also seen in this work. The most important advantage of using this compound probe is that it can not only save space and vacuum ports but also measure more physical quantities at the same time, contributing to further physical analysis.
- 9 March 2017
- Published by Springer Nature in The European Physical Journal D
- Vol. 71 (3) , 60
Investigation on the effect of pressure on turbulent transports of the IR-T1 Tokamak plasma
- 9 March 2017
- Published by Springer Nature in The European Physical Journal D
- Vol. 71 (3) , 60
Investigation on the effect of pressure on turbulent transports of the IR-T1 Tokamak plasma
- 1 January 2017
- Published by AIP Publishing
Study of particle transport in IR-T1 Tokamak
In this paper, particles transport and plasma confinement in different conditions were investigated. For this purpose, the important plasma parameters such as radial and poliodal electric fields, radial and poloidal turbulent transport and Reynolds stress were calculated in three different pressures of hydrogen gas (1.9, 2.3 and 2.7 Torr). Measurements were done by two probes: radial and poloidal array of Langmuir probes. At each pressure, we also investigated the effect of biased voltages (±200V) produced by limiter biasing system on plasma confinement. Particle transport is calculated in both the radial and poloidal directions at plasma edge by arrays of Langmuir probes. The results show that filling gas pressure of the vacuum chamber and external electric field have key role in plasma confinement.
- 1 January 2017
- Published by AIP Publishing
Study of particle transport in IR-T1 Tokamak
In this paper, particles transport and plasma confinement in different conditions were investigated. For this purpose, the important plasma parameters such as radial and poliodal electric fields, radial and poloidal turbulent transport and Reynolds stress were calculated in three different pressures of hydrogen gas (1.9, 2.3 and 2.7 Torr). Measurements were done by two probes: radial and poloidal array of Langmuir probes. At each pressure, we also investigated the effect of biased voltages (±200V) produced by limiter biasing system on plasma confinement. Particle transport is calculated in both the radial and poloidal directions at plasma edge by arrays of Langmuir probes. The results show that filling gas pressure of the vacuum chamber and external electric field have key role in plasma confinement.
- 1 November 2016
- Published by IOP Publishing in Chinese Physics Letters
- Vol. 33 (11) , 115202
Improving Plasma Confinement by Controlling Hard X-Ray
Since runaway electrons and magnetohydrodynamics activity can contribute to serious damage and energy losses in tokamaks, the effect of an external electric field on runaway electrons and hard x-ray spectra is investigated. Parameters such as the plasma current, the hard x-ray photons count and the mean energy of runaway electrons are measured. Positive and negative voltages of 300 V are applied at 10 ms after the plasma initiation (while the plasma is forming), at 15 ms (while the plasma is stable) and at 20 ms (while the plasma is fading away) to attain the most effective time of applying the external electric field. The number of hard x-ray photons has the most changes in the range of 0–200 keV when the external electric fields are applied. Also in the duration of 20–30 ms of plasma the greatest number of hard x-ray spectra is detected. When the external electric fields are applied, the mean energy of runaway electrons reduces significantly, especially at 15 ms (while the plasma is stable).
- 1 November 2016
- Published by IOP Publishing in Chinese Physics Letters
- Vol. 33 (11) , 115202
Improving Plasma Confinement by Controlling Hard X-Ray
Since runaway electrons and magnetohydrodynamics activity can contribute to serious damage and energy losses in tokamaks, the effect of an external electric field on runaway electrons and hard x-ray spectra is investigated. Parameters such as the plasma current, the hard x-ray photons count and the mean energy of runaway electrons are measured. Positive and negative voltages of 300 V are applied at 10 ms after the plasma initiation (while the plasma is forming), at 15 ms (while the plasma is stable) and at 20 ms (while the plasma is fading away) to attain the most effective time of applying the external electric field. The number of hard x-ray photons has the most changes in the range of 0–200 keV when the external electric fields are applied. Also in the duration of 20–30 ms of plasma the greatest number of hard x-ray spectra is detected. When the external electric fields are applied, the mean energy of runaway electrons reduces significantly, especially at 15 ms (while the plasma is stable).
- 28 October 2016
- Published by Springer Nature in Research on Chemical Intermediates
- Vol. 43 (5) , 2889-2890
Answer to the comment on: “The effect of pressure on morphological features and quality of synthesized graphene” [Res Chem Intermed Journal DOI 10.1007/s11164-016-2758-6]
- 28 October 2016
- Published by Springer Nature in Research on Chemical Intermediates
- Vol. 43 (5) , 2889-2890
Answer to the comment on: “The effect of pressure on morphological features and quality of synthesized graphene” [Res Chem Intermed Journal DOI 10.1007/s11164-016-2758-6]
- 11 June 2016
- Published by Springer Nature in Research on Chemical Intermediates
- Vol. 42 (12) , 8261-8272
The effect of pressure on morphological features and quality of synthesized graphene
- 11 June 2016
- Published by Springer Nature in Research on Chemical Intermediates
- Vol. 42 (12) , 8261-8272
The effect of pressure on morphological features and quality of synthesized graphene