Laurent Robert
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Laurent Robert has a total of 105 co-authors. Here are the top co-authors by number of shared publications:
- Jean-José Orteu
Université de Toulouse, Institut Clément Ader (ICA), CNRS, IMT Mines Albi, INSA, UPS, ISAE-SUPAERO, Albi, France
12 shared publications - Vincent Velay
Université de Toulouse
6 shared publications B. Vergnes
CEMEF, École des Mines de Paris, Sophia Antipolis, France
4 shared publicationsM. Fazzini
INP/ENIT, LGP EA 1905 Université de Toulouse Tarbes France
4 shared publicationsB. Wattrisse
Laboratoire de Mécanique et Génie Civil, UMR CNRS 5508 Université Montpellier 2 Montpellier France
3 shared publications- Emmanuel Marin
Laboratoire Hubert Curien, UMR CNRS 5516, Université Jean Monnet, 42000 Saint-Etienne, France
3 shared publications
Latest Publications
- 1 February 2016
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 77, 44-53
Unstructured finite element-based digital image correlation with enhanced management of quadrature and lens distortions
- 1 February 2016
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 77, 44-53
Unstructured finite element-based digital image correlation with enhanced management of quadrature and lens distortions
- 8 September 2014
- Published by Springer Nature
- p. 265-275
Multiscale FE-Based DIC for Enhanced Measurements and Constitutive Parameter Identification
- 8 September 2014
- Published by Springer Nature
- p. 265-275
Multiscale FE-Based DIC for Enhanced Measurements and Constitutive Parameter Identification
- 26 April 2014
- Published by Springer Nature in Experimental Mechanics
- Vol. 55 (1) , 121-137
Multiscale Displacement Field Measurement Using Digital Image Correlation: Application to the Identification of Elastic Properties
- 26 April 2014
- Published by Springer Nature in Experimental Mechanics
- Vol. 55 (1) , 121-137
Multiscale Displacement Field Measurement Using Digital Image Correlation: Application to the Identification of Elastic Properties
- 10 October 2013
- Published by SAGE Publications in Journal of Reinforced Plastics and Composites
- Vol. 32 (21) , 1646-1655
Effect of acetylation and additive on the tensile properties of wood fiber–high-density polyethylene composite
The wood plastic composites studied in this work are composed of high-density polyethylene matrix and Pinus pinaster wood fibers. Despite some interesting intrinsic properties, this wood plastic composite has limited mechanical properties because of the incompatibility between the polar hydrophilic fibers and the non-polar hydrophobic matrix. In this study, the effects of maleic anhydride-modified polyethylene additive, of carbon chains grafted by acetylation and of wood fiber contents on the tensile mechanical properties of the wood plastic composite were studied. Tensile tests were carried out using digital image correlation as an intrusiveness and robust method for strain measurements. Results showed first that the addition of wood fibers made the wood plastic composite stiffer but less flexible. Acetylation improved the interfacial adhesion properties: the Young modulus was increased and a lower strain at failure was reported. The coupling agent also increased the compatibility but mainly in the case where there was no grafted chain. With regard to the carbon chains, the number of grafts improved the elastic properties while their length did not appear to have any influence. Finally, a scanning electron microscope was used to characterize the post-mortem morphology of the fracture surfaces, the results of which supported the observations obtained from the tensile mechanical properties.
- 10 October 2013
- Published by SAGE Publications in Journal of Reinforced Plastics and Composites
- Vol. 32 (21) , 1646-1655
Effect of acetylation and additive on the tensile properties of wood fiber–high-density polyethylene composite
The wood plastic composites studied in this work are composed of high-density polyethylene matrix and Pinus pinaster wood fibers. Despite some interesting intrinsic properties, this wood plastic composite has limited mechanical properties because of the incompatibility between the polar hydrophilic fibers and the non-polar hydrophobic matrix. In this study, the effects of maleic anhydride-modified polyethylene additive, of carbon chains grafted by acetylation and of wood fiber contents on the tensile mechanical properties of the wood plastic composite were studied. Tensile tests were carried out using digital image correlation as an intrusiveness and robust method for strain measurements. Results showed first that the addition of wood fibers made the wood plastic composite stiffer but less flexible. Acetylation improved the interfacial adhesion properties: the Young modulus was increased and a lower strain at failure was reported. The coupling agent also increased the compatibility but mainly in the case where there was no grafted chain. With regard to the carbon chains, the number of grafts improved the elastic properties while their length did not appear to have any influence. Finally, a scanning electron microscope was used to characterize the post-mortem morphology of the fracture surfaces, the results of which supported the observations obtained from the tensile mechanical properties.
Assessment of Digital Image Correlation Measurement Accuracy in the Ultimate Error Regime: Main Results of a Collaborative Benchmark
We report on the main results of a collaborative work devoted to the study of the uncertainties associated with Digital image correlation techniques (DIC). More specifically, the dependence of displacement measurement uncertainties with both image characteristics and DIC parameters is emphasised. A previous work [Bornert et al. (2009) Assessment of digital image correlation measurement errors: methodology and results. Exp. Mech. 49, 353–370] dedicated to situations with spatially fluctuating displacement fields demonstrated the existence of an ‘ultimate error’ regime, insensitive to the mismatch between the shape function and the real displacement field. The present work is focused on this ultimate error. To ensure that there is no mismatch error, synthetic images of in‐plane rigid body translation have been analysed. Several DIC softwares developed by or in use in the French community have been used to explore the effects of a large number of settings. The discrepancies between DIC evaluated displacements and prescribed ones have been statistically analysed in terms of random errors and systematic bias, in correlation with the fractional part τ of the displacement component expressed in pixels. Main results are as follows: (i) bias amplitude is almost always insensitive to subset size, (ii) standard deviation of random error increases with noise level and decreases with subset size and (iii) DIC formulations can be split up into two main families regarding bias sensitivity to noise. For the first one, bias amplitude increases with noise while it remains nearly constant for the second one. In addition, for the first family, a strong dependence of random error with τ is observed for noisy images.
Assessment of Digital Image Correlation Measurement Accuracy in the Ultimate Error Regime: Main Results of a Collaborative Benchmark
We report on the main results of a collaborative work devoted to the study of the uncertainties associated with Digital image correlation techniques (DIC). More specifically, the dependence of displacement measurement uncertainties with both image characteristics and DIC parameters is emphasised. A previous work [Bornert et al. (2009) Assessment of digital image correlation measurement errors: methodology and results. Exp. Mech. 49, 353–370] dedicated to situations with spatially fluctuating displacement fields demonstrated the existence of an ‘ultimate error’ regime, insensitive to the mismatch between the shape function and the real displacement field. The present work is focused on this ultimate error. To ensure that there is no mismatch error, synthetic images of in‐plane rigid body translation have been analysed. Several DIC softwares developed by or in use in the French community have been used to explore the effects of a large number of settings. The discrepancies between DIC evaluated displacements and prescribed ones have been statistically analysed in terms of random errors and systematic bias, in correlation with the fractional part τ of the displacement component expressed in pixels. Main results are as follows: (i) bias amplitude is almost always insensitive to subset size, (ii) standard deviation of random error increases with noise level and decreases with subset size and (iii) DIC formulations can be split up into two main families regarding bias sensitivity to noise. For the first one, bias amplitude increases with noise while it remains nearly constant for the second one. In addition, for the first family, a strong dependence of random error with τ is observed for noisy images.
- 26 July 2013
- Published by Wiley in Polymer Engineering & Science
- Vol. 54 (7) , 1585-1594
Assessment of thermoset cure‐induced strains by fiber bragg grating sensor
Composites based on thermosetting resin and reinforcement fibers present generally unwanted residual internal stresses inherent to their elaboration process. In this article, different curing experiments of thermosets (isothermal and anisothermal) were monitored using optical fiber Bragg grating (FBG) sensors and thermocouples, to assess the cure‐induced strains. A thermokinetic model evaluates the degree of conversion of the resin. At the onset of stress transfer to the optical fiber, the degree of conversion ranges between 0.63 and 0.68. During curing, the FBG deforms under chemical shrinkage with an amplitude widely lower than the expected chemical strain, showing that the FBG signal is not directly related to the actual chemical shrinkage. However, once the resin is cured, the FBG sensor provides directly the coefficient of thermal expansion of the resin, as function of temperature and degree of conversion, reached in the different experiments. POLYM. ENG. SCI., 54:1585–1594, 2014. © 2013 Society of Plastics Engineers
- 26 July 2013
- Published by Wiley in Polymer Engineering & Science
- Vol. 54 (7) , 1585-1594
Assessment of thermoset cure‐induced strains by fiber bragg grating sensor
Composites based on thermosetting resin and reinforcement fibers present generally unwanted residual internal stresses inherent to their elaboration process. In this article, different curing experiments of thermosets (isothermal and anisothermal) were monitored using optical fiber Bragg grating (FBG) sensors and thermocouples, to assess the cure‐induced strains. A thermokinetic model evaluates the degree of conversion of the resin. At the onset of stress transfer to the optical fiber, the degree of conversion ranges between 0.63 and 0.68. During curing, the FBG deforms under chemical shrinkage with an amplitude widely lower than the expected chemical strain, showing that the FBG signal is not directly related to the actual chemical shrinkage. However, once the resin is cured, the FBG sensor provides directly the coefficient of thermal expansion of the resin, as function of temperature and degree of conversion, reached in the different experiments. POLYM. ENG. SCI., 54:1585–1594, 2014. © 2013 Society of Plastics Engineers
- 30 May 2013
- Published by Wiley in Polymer Engineering & Science
- Vol. 54 (3) , 626-635
Anisothermal thermosetting resin cure monitored by optical fiber refractometer
The cure monitoring of composite parts is an important key to optimize the industrial curing cycles. In this study, it is proposed to monitor the cure of a thermosetting resin by a Fresnel refractometer. The measurements are first compared to dielectric analyses and predictions of a thermo‐kinetic model that uses parameters from the literature. Under isothermal conditions, the results show that the Fresnel power can be directly exploited to obtain qualitatively the degree of conversion. This is also demonstrated in anisothermal conditions by correcting the Fresnel signal from its temperature dependence. If the initial degree of conversion is known, its quantitative assessment is achieved using the Fresnel and temperature measurements. POLYM. ENG. SCI., 54:626–635, 2014. © 2013 Society of Plastics Engineers
- 30 May 2013
- Published by Wiley in Polymer Engineering & Science
- Vol. 54 (3) , 626-635
Anisothermal thermosetting resin cure monitored by optical fiber refractometer
The cure monitoring of composite parts is an important key to optimize the industrial curing cycles. In this study, it is proposed to monitor the cure of a thermosetting resin by a Fresnel refractometer. The measurements are first compared to dielectric analyses and predictions of a thermo‐kinetic model that uses parameters from the literature. Under isothermal conditions, the results show that the Fresnel power can be directly exploited to obtain qualitatively the degree of conversion. This is also demonstrated in anisothermal conditions by correcting the Fresnel signal from its temperature dependence. If the initial degree of conversion is known, its quantitative assessment is achieved using the Fresnel and temperature measurements. POLYM. ENG. SCI., 54:626–635, 2014. © 2013 Society of Plastics Engineers
- 16 February 2013
- Published by Springer Nature in Experimental Mechanics
- Vol. 57 (9) , 1515
Addendum to: Assessment of Digital Image Correlation Measurement Errors: Methodology and Results [Experimental Mechanics 49(3)]
- 16 February 2013
- Published by Springer Nature in Experimental Mechanics
- Vol. 57 (9) , 1515
Addendum to: Assessment of Digital Image Correlation Measurement Errors: Methodology and Results [Experimental Mechanics 49(3)]
- 1 February 2013
- Published by Elsevier in Journal of the European Ceramic Society
- Vol. 33 (2) , 221-231
Applicability of image correlation techniques to characterise asymmetric refractory creep during bending tests
- 1 February 2013
- Published by Elsevier in Journal of the European Ceramic Society
- Vol. 33 (2) , 221-231
Applicability of image correlation techniques to characterise asymmetric refractory creep during bending tests
- 1 December 2012
- Published by Elsevier in Polymer Testing
- Vol. 31 (8) , 1045-1052
Liquid Resin Infusion process monitoring with superimposed Fibre Bragg Grating sensor
- 1 December 2012
- Published by Elsevier in Polymer Testing
- Vol. 31 (8) , 1045-1052
Liquid Resin Infusion process monitoring with superimposed Fibre Bragg Grating sensor