Elizabeth J. Judge
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Elizabeth J. Judge has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
- James E. Barefield
Los Alamos National Laboratory, Los Alamos, New Mexico 87545
7 shared publications - David Parker Kilcrease
Los Alamos National Laboratory, Los Alamos, NM 87545, USA
6 shared publications - Heather Marie Johns
Los Alamos National Laboratory
5 shared publications - James Colgan
Los Alamos National Laboratory
5 shared publications - John M. Berg
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
3 shared publications - Keri Campbell
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
3 shared publications
Latest Publications
- Open Access
- 6 March 2021
- Published by Wiley in Statistical Analysis and Data Mining: An ASA Data Science Journal
- Vol. 14 (6) , 596-605
An initial exploration of Bayesian model calibration for estimating the composition of rocks and soils on Mars
The Mars Curiosity rover carries an instrument, ChemCam, designed to measure the composition of surface rocks and soil using laser‐induced breakdown spectroscopy (LIBS). The measured spectra from this instrument must be analyzed to identify the component elements in the target sample, as well as their relative proportions. This process, which we call disaggregation, is complicated by so‐called matrix effects, which describe nonlinear changes in the relative heights of emission lines as an unknown function of composition due to atomic interactions within the LIBS plasma. In this work, we explore the use of the plasma physics code ATOMIC, developed at Los Alamos National Laboratory, for the disaggregation task. ATOMIC has recently been used to model LIBS spectra and can robustly reproduce matrix effects from first principles. The ability of ATOMIC to predict LIBS spectra presents an exciting opportunity to perform disaggregation in a manner not yet tried in the LIBS community, namely via Bayesian model calibration. However, using it directly to solve our inverse problem is computationally intractable due to the large parameter space and the computation time required to produce a single output. Therefore, we also explore the use of emulators as a fast solution for this analysis. We discuss a proof of concept Gaussian process emulator for disaggregating two‐element compounds of sodium and copper. The training and test datasets were simulated with ATOMIC using a Latin hypercube design. After testing the performance of the emulator, we successfully recover the composition of 25 test spectra with Bayesian model calibration.
- 6 March 2021
- Published by Wiley in Statistical Analysis and Data Mining: An ASA Data Science Journal
- Vol. 14 (6) , 596-605
Open AccessAn initial exploration of Bayesian model calibration for estimating the composition of rocks and soils on Mars
The Mars Curiosity rover carries an instrument, ChemCam, designed to measure the composition of surface rocks and soil using laser‐induced breakdown spectroscopy (LIBS). The measured spectra from this instrument must be analyzed to identify the component elements in the target sample, as well as their relative proportions. This process, which we call disaggregation, is complicated by so‐called matrix effects, which describe nonlinear changes in the relative heights of emission lines as an unknown function of composition due to atomic interactions within the LIBS plasma. In this work, we explore the use of the plasma physics code ATOMIC, developed at Los Alamos National Laboratory, for the disaggregation task. ATOMIC has recently been used to model LIBS spectra and can robustly reproduce matrix effects from first principles. The ability of ATOMIC to predict LIBS spectra presents an exciting opportunity to perform disaggregation in a manner not yet tried in the LIBS community, namely via Bayesian model calibration. However, using it directly to solve our inverse problem is computationally intractable due to the large parameter space and the computation time required to produce a single output. Therefore, we also explore the use of emulators as a fast solution for this analysis. We discuss a proof of concept Gaussian process emulator for disaggregating two‐element compounds of sodium and copper. The training and test datasets were simulated with ATOMIC using a Latin hypercube design. After testing the performance of the emulator, we successfully recover the composition of 25 test spectra with Bayesian model calibration.
- 9 August 2017
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 31 (20) , 1690-1698
A simple and economical strategy for obtaining calibration plots for relative quantification of positional isomers of YYX/YXY triglycerides using high‐performance liquid chromatography/tandem mass spectrometry
Rationale: Positional analysis of intact triglycerides could provide greater insights into the link between fatty acid position and lipotoxic diseases. However, this methodology has been impeded by lack of commercial availability of positionally pure triglycerides. This work reports on a strategy for defining calibration plots for YXY/YYX triglyceride systems based on the product ion intensities in the collision‐induced dissociation spectra of ammoniated precursor ions. Methods: A set of triglycerides were synthesized and analyzed by electrospray ionization tandem mass spectrometry using an ion trap mass spectrometer. The product ion spectra of the ammoniated precursor ions were collected for 42 triglyceride systems of the form YXY/YYX, where Y represents C 16:0 , C 18:1( c ‐9) and C 20:4( cccc ‐5,8,11,14) . Three‐point calibration plots were prepared by plotting the relative abundance of the YY + product ion vs. the relative abundance of the YYX positional isomer. Results: The calibration plots were shown to give relative abundances of positional isomers accurate to within ±0.02 for most systems. Using an ion trap, under a controlled set of collision parameters, the slopes of the calibration plots can be used to compare the sensitivities of the product ion intensities to fatty acid position for various triglyceride systems. The average slopes of the calibration plots for the C 16:0 , C 18:1( c ‐9) and C 20:4( cccc ‐5,8,11,14) systems were 0.29 ± 0.05, 0.21 ± 0.05 and 0.045 ± 0.005, respectively. Conclusions: While the presence of multiple unsaturated fatty acids tends to slightly decrease the slopes of the calibration plots, the data suggest that the sensitivities are sufficient for performing positional analysis of most triglyceride systems. However, the presence of unsaturated fatty acids that contain double bonds close to the carbonyl group, such as arachidonic acid, tends to dramatically decrease positional sensitivity.
- 9 August 2017
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 31 (20) , 1690-1698
A simple and economical strategy for obtaining calibration plots for relative quantification of positional isomers of YYX/YXY triglycerides using high‐performance liquid chromatography/tandem mass spectrometry
Rationale: Positional analysis of intact triglycerides could provide greater insights into the link between fatty acid position and lipotoxic diseases. However, this methodology has been impeded by lack of commercial availability of positionally pure triglycerides. This work reports on a strategy for defining calibration plots for YXY/YYX triglyceride systems based on the product ion intensities in the collision‐induced dissociation spectra of ammoniated precursor ions. Methods: A set of triglycerides were synthesized and analyzed by electrospray ionization tandem mass spectrometry using an ion trap mass spectrometer. The product ion spectra of the ammoniated precursor ions were collected for 42 triglyceride systems of the form YXY/YYX, where Y represents C 16:0 , C 18:1( c ‐9) and C 20:4( cccc ‐5,8,11,14) . Three‐point calibration plots were prepared by plotting the relative abundance of the YY + product ion vs. the relative abundance of the YYX positional isomer. Results: The calibration plots were shown to give relative abundances of positional isomers accurate to within ±0.02 for most systems. Using an ion trap, under a controlled set of collision parameters, the slopes of the calibration plots can be used to compare the sensitivities of the product ion intensities to fatty acid position for various triglyceride systems. The average slopes of the calibration plots for the C 16:0 , C 18:1( c ‐9) and C 20:4( cccc ‐5,8,11,14) systems were 0.29 ± 0.05, 0.21 ± 0.05 and 0.045 ± 0.005, respectively. Conclusions: While the presence of multiple unsaturated fatty acids tends to slightly decrease the slopes of the calibration plots, the data suggest that the sensitivities are sufficient for performing positional analysis of most triglyceride systems. However, the presence of unsaturated fatty acids that contain double bonds close to the carbonyl group, such as arachidonic acid, tends to dramatically decrease positional sensitivity.
- 3 April 2017
- Published by Office of Scientific and Technical Information (OSTI)
Comparative Assessment of Copper-Coated Kapton: Analysis of Microclad from Several Manufacturing Lots
The U.S. Department of Energy's Office of Scientific and Technical Information
- 3 April 2017
- Published by Office of Scientific and Technical Information (OSTI)
Comparative Assessment of Copper-Coated Kapton: Analysis of Microclad from Several Manufacturing Lots
The U.S. Department of Energy's Office of Scientific and Technical Information
- Open Access
- 6 July 2016
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 163 (9) , F1023-F1031
Cerium Migration during PEM Fuel Cell Accelerated Stress Testing
Cerium is a radical scavenger which improves polymer electrolyte membrane (PEM) fuel cell durability. During operation, however, cerium rapidly migrates in the PEM and into the catalyst layers (CLs). In this work, membrane electrode assemblies (MEAs) were subjected to accelerated stress tests (ASTs) under different humidity conditions. Cerium migration was characterized in the MEAs after ASTs using X-ray fluorescence. During fully humidified operation, water flux from cell inlet to outlet generated in-plane cerium gradients. Conversely, cerium profiles were flat during low humidity operation, where in-plane water flux was negligible, however, migration from the PEM into the CLs was enhanced. Humidity cycling resulted in both in-plane cerium gradients due to water flux during the hydration component of the cycle, and significant migration into the CLs. Fluoride and cerium emissions into effluent cell waters were measured during ASTs and correlated, which signifies that ionomer degradation products serve as possible counter-ions for cerium emissions. Fluoride emission rates were also correlated to final PEM cerium contents, which indicates that PEM degradation and cerium migration are coupled. It is proposed that cerium migrates from the PEM due to humidification conditions and degradation, and is subsequently stabilized in the CLs by carbon catalyst supports.
- 6 July 2016
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 163 (9) , F1023-F1031
Open AccessCerium Migration during PEM Fuel Cell Accelerated Stress Testing
Cerium is a radical scavenger which improves polymer electrolyte membrane (PEM) fuel cell durability. During operation, however, cerium rapidly migrates in the PEM and into the catalyst layers (CLs). In this work, membrane electrode assemblies (MEAs) were subjected to accelerated stress tests (ASTs) under different humidity conditions. Cerium migration was characterized in the MEAs after ASTs using X-ray fluorescence. During fully humidified operation, water flux from cell inlet to outlet generated in-plane cerium gradients. Conversely, cerium profiles were flat during low humidity operation, where in-plane water flux was negligible, however, migration from the PEM into the CLs was enhanced. Humidity cycling resulted in both in-plane cerium gradients due to water flux during the hydration component of the cycle, and significant migration into the CLs. Fluoride and cerium emissions into effluent cell waters were measured during ASTs and correlated, which signifies that ionomer degradation products serve as possible counter-ions for cerium emissions. Fluoride emission rates were also correlated to final PEM cerium contents, which indicates that PEM degradation and cerium migration are coupled. It is proposed that cerium migrates from the PEM due to humidification conditions and degradation, and is subsequently stabilized in the CLs by carbon catalyst supports.
- 1 June 2016
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 120, 1-8
Analysis of geological materials containing uranium using laser-induced breakdown spectroscopy
- 1 June 2016
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 120, 1-8
Analysis of geological materials containing uranium using laser-induced breakdown spectroscopy
- 6 May 2016
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 310 (2) , 533-540
Limiting spectroscopic interferences of 239Pu and 237Np in a UO2 matrix using LA-ICP-MS
- 6 May 2016
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 310 (2) , 533-540
Limiting spectroscopic interferences of 239Pu and 237Np in a UO2 matrix using LA-ICP-MS
- 14 September 2015
- Published by The Electrochemical Society in ECS Transactions
- Vol. 69 (17) , 1009-1015
Cerium Migration during PEM Fuel Cell Assembly and Operation
In PEM fuel cells, cerium migration is influenced by proton flux,as well as gradients in electric potential, ion concentration, andwater content. These factors were investigated in ex situexperiments and in operating fuel cells. Potential-inducedmigration was measured ex situ in hydrated window cells. CeriumcontainingMEAs were also fabricated and tested under ASTs.MEA disassembly and subsequent XRF analysis were used toobserve rapid cerium migration within the MEA. During MEA hotpressing, humidification, and low RH operation at OCV, ionicdiffusion causes uniform migration from the membrane into thecatalyst layers. During high RH operation at OCV, in-plane ceriumgradients arise due to variations in water content. These gradientsmay diminish the scavenging efficacy of cerium by reducing itsproximity to generated radicals.
- 14 September 2015
- Published by The Electrochemical Society in ECS Transactions
- Vol. 69 (17) , 1009-1015
Cerium Migration during PEM Fuel Cell Assembly and Operation
In PEM fuel cells, cerium migration is influenced by proton flux,as well as gradients in electric potential, ion concentration, andwater content. These factors were investigated in ex situexperiments and in operating fuel cells. Potential-inducedmigration was measured ex situ in hydrated window cells. CeriumcontainingMEAs were also fabricated and tested under ASTs.MEA disassembly and subsequent XRF analysis were used toobserve rapid cerium migration within the MEA. During MEA hotpressing, humidification, and low RH operation at OCV, ionicdiffusion causes uniform migration from the membrane into thecatalyst layers. During high RH operation at OCV, in-plane ceriumgradients arise due to variations in water content. These gradientsmay diminish the scavenging efficacy of cerium by reducing itsproximity to generated radicals.
- 1 August 2015
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 110, 20-30
Theoretical modeling and analysis of the emission spectra of a ChemCam standard: Basalt BIR-1A
- 1 August 2015
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 110, 20-30
Theoretical modeling and analysis of the emission spectra of a ChemCam standard: Basalt BIR-1A
- 10 March 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9380, 938004-938004-8
Purification of precursors of Yb3+-doped YLF crystals by solvent extraction and electrochemical processing
- 10 March 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9380, 938004-938004-8
Purification of precursors of Yb3+-doped YLF crystals by solvent extraction and electrochemical processing