Jose-Luis Bueso-Bello
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jose-Luis Bueso-Bello has a total of 92 co-authors. Here are the top co-authors by number of shared publications:
- Paola Rizzoli
Microwaves and Radar Institute, German Aerospace Center (DLR), 82234 Wessling, Germany
17 shared publications - Michele Martone
German Aerospace Center (DLR), Microwaves and Radar Institute, Weling, Germany
9 shared publications - Carolina González
German Aerospace Center, Münchener Str. 20
8 shared publications - Pau Prats-Iraola
Microwaves and Radar Institute, German Aerospace Center (DLR), Weling, Germany
6 shared publications - Pietro Milillo
Department of Civil and Environmental Engineering, University of Houston, Houston, TX, USA
6 shared publications - Daniel Carcereri
Microwaves and Radar Institute, German Aerospace Center, Wessling, Germany
4 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 19, 33633-33659
Self-Supervised Learning for Very High-Resolution Forest Mapping With TanDEM-X InSAR Data
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 19, 33633-33659
Open AccessSelf-Supervised Learning for Very High-Resolution Forest Mapping With TanDEM-X InSAR Data
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Geoscience and Remote Sensing Magazine
- Vol. 13 (2) , 116-151
TanDEM-X: The 4D Mission Phase for Earth Surface Dynamics: Science activities highlights and new data products after 15 years of bistatic operations
The main goal of the TerraSAR-X Add-On for Digital Elevation Measurements (TanDEM-X) mission is the generation of a global digital elevation model (DEM) of unprecedented accuracy and coverage. The global TanDEM-X DEM product became available in 2016, surpassed all expectations, and became a reference for a wide range of Earth science, commercial, and geospatial applications. In addition, new information products, such as DEM change maps (DCMs), have been developed and are available to the geoscience and remote sensing community. Beyond the operational products, new science applications have been demonstrated and are summarized in this article, along with experimental data acquisitions. This article also aims to provide an overview of science activities with TanDEM-X data and science data acquisitions planned for the coming years.
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Geoscience and Remote Sensing Magazine
- Vol. 13 (2) , 116-151
TanDEM-X: The 4D Mission Phase for Earth Surface Dynamics: Science activities highlights and new data products after 15 years of bistatic operations
The main goal of the TerraSAR-X Add-On for Digital Elevation Measurements (TanDEM-X) mission is the generation of a global digital elevation model (DEM) of unprecedented accuracy and coverage. The global TanDEM-X DEM product became available in 2016, surpassed all expectations, and became a reference for a wide range of Earth science, commercial, and geospatial applications. In addition, new information products, such as DEM change maps (DCMs), have been developed and are available to the geoscience and remote sensing community. Beyond the operational products, new science applications have been demonstrated and are summarized in this article, along with experimental data acquisitions. This article also aims to provide an overview of science activities with TanDEM-X data and science data acquisitions planned for the coming years.
- Open Access
- 23 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 18 (19391404) , 3385-3397
Sentinel-1-Aided Mutual Calibration of TanDEM-X DEMs for the Estimation of Height and Volume Changes
Digital elevation models (DEM) derived from TanDEM-X single-pass interferometric SAR data are widely used for a large vary of applications. One of the main application fields regards the monitoring of topographic changes, which can be properly estimated by differentiating two DEM scenes acquired at different times. In this scenario, a critical aspect is represented by the precise mutual calibration of the two DEMs, which are normally affected by residual offsets and tilts caused by uncertainties in the baseline determination. This calibration is in general performed by utilizing reference tie-points, whose location and height is known a priori, or estimated through other reference sensors, such as GPS or LiDAR data. The manual procedure is time-consuming and can be jeopardized by the absence of available external reference points. In this paper, we present a novel technique for performing an automatic selection of reliable natural tie-points from Sentinel-1 repeat-pass timeseries, by exploiting persistent scatterers candidates, and we discuss their applicability to TanDEM-X data. We propose a novel method for retrieving a set of reliable natural calibration targets and for performing an effective mutual calibration of TanDEM-X time-tagged DEMs. The approach is validated by considering the estimation of lava field volumes in the test-case scenario of the volcanic eruptions in the Reykjanes Peninsula, Iceland, occurred between 2021 and 2023. Thanks to the continuous global coverage of Sentinel-1, this approach can be applied when no a priori knowledge on reference tie-points is available, allowing for the precise estimation of height and volume changes.
- 23 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 18 (19391404) , 3385-3397
Open AccessSentinel-1-Aided Mutual Calibration of TanDEM-X DEMs for the Estimation of Height and Volume Changes
Digital elevation models (DEM) derived from TanDEM-X single-pass interferometric SAR data are widely used for a large vary of applications. One of the main application fields regards the monitoring of topographic changes, which can be properly estimated by differentiating two DEM scenes acquired at different times. In this scenario, a critical aspect is represented by the precise mutual calibration of the two DEMs, which are normally affected by residual offsets and tilts caused by uncertainties in the baseline determination. This calibration is in general performed by utilizing reference tie-points, whose location and height is known a priori, or estimated through other reference sensors, such as GPS or LiDAR data. The manual procedure is time-consuming and can be jeopardized by the absence of available external reference points. In this paper, we present a novel technique for performing an automatic selection of reliable natural tie-points from Sentinel-1 repeat-pass timeseries, by exploiting persistent scatterers candidates, and we discuss their applicability to TanDEM-X data. We propose a novel method for retrieving a set of reliable natural calibration targets and for performing an effective mutual calibration of TanDEM-X time-tagged DEMs. The approach is validated by considering the estimation of lava field volumes in the test-case scenario of the volcanic eruptions in the Reykjanes Peninsula, Iceland, occurred between 2021 and 2023. Thanks to the continuous global coverage of Sentinel-1, this approach can be applied when no a priori knowledge on reference tie-points is available, allowing for the precise estimation of height and volume changes.
- Open Access
- 29 June 2024
- Published by Elsevier in Remote Sensing of Environment
- Vol. 311
Generation of country-scale canopy height maps over Gabon using deep learning and TanDEM-X InSAR data
- 29 June 2024
- Published by Elsevier in Remote Sensing of Environment
- Vol. 311
Open AccessGeneration of country-scale canopy height maps over Gabon using deep learning and TanDEM-X InSAR data
- Open Access
- 4 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 17 (19391404) , 1673-1690
Characterization of the Amazon Rainforest Backscatter at X-Band Using TanDEM-X Data
The radiometric calibration of spaceborne SAR products plays a key role for ensuring a good performance of the whole end-to-end system and requires a precise knowledge of both the radar system and the illuminated target on ground. The shape of the antenna pattern in elevation can be directly estimated by analyzing SAR detected images in presence of a homogeneous and flat backscatter profile in the slant range dimension. To this aim, tropical rainforests have been established by the SAR community as well-known calibration sites for performing such an activity. Here, according to the hypothesis of isotropic scattering, the backscattering coefficient in terms of unit area perpendicular to the antenna, called gamma nought, is assumed to remain constant with respect to the incidence angle. Nevertheless, several studies using X- and C-band sensors have shown a slight dependency of the backscatter on the incidence angle, as well as on ground target properties and meteorological conditions. In this work, we present a detailed statistical characterization of radar backscatter at X-band over the Amazon rainforest using TanDEM-X data and we provide insights on how to best utilize radar backscatter data in this region for SAR calibration and modeling purposes. In particular, we concentrate on the dependency of the Amazon rainforest backscatter on the day-time of acquisition, which is directly related to the orbit direction of TanDEM-X. Furthermore, we analyze the seasonal variation of the radar backscatter, as well as possible radiation variations over different locations in the Amazon, characterized by different climate conditions and biomes. Finally, we provide a series of backscatter models for different scenarios, which can be used, e.g., for X-band spaceborne SAR system design and theoretical modeling.
- 4 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 17 (19391404) , 1673-1690
Open AccessCharacterization of the Amazon Rainforest Backscatter at X-Band Using TanDEM-X Data
The radiometric calibration of spaceborne SAR products plays a key role for ensuring a good performance of the whole end-to-end system and requires a precise knowledge of both the radar system and the illuminated target on ground. The shape of the antenna pattern in elevation can be directly estimated by analyzing SAR detected images in presence of a homogeneous and flat backscatter profile in the slant range dimension. To this aim, tropical rainforests have been established by the SAR community as well-known calibration sites for performing such an activity. Here, according to the hypothesis of isotropic scattering, the backscattering coefficient in terms of unit area perpendicular to the antenna, called gamma nought, is assumed to remain constant with respect to the incidence angle. Nevertheless, several studies using X- and C-band sensors have shown a slight dependency of the backscatter on the incidence angle, as well as on ground target properties and meteorological conditions. In this work, we present a detailed statistical characterization of radar backscatter at X-band over the Amazon rainforest using TanDEM-X data and we provide insights on how to best utilize radar backscatter data in this region for SAR calibration and modeling purposes. In particular, we concentrate on the dependency of the Amazon rainforest backscatter on the day-time of acquisition, which is directly related to the orbit direction of TanDEM-X. Furthermore, we analyze the seasonal variation of the radar backscatter, as well as possible radiation variations over different locations in the Amazon, characterized by different climate conditions and biomes. Finally, we provide a series of backscatter models for different scenarios, which can be used, e.g., for X-band spaceborne SAR system design and theoretical modeling.
- Open Access
- 18 July 2023
- Published by MDPI AG in Remote Sensing
- Vol. 15 (14) , 3589
Relationship between Lidar-Derived Canopy Densities and the Scattering Phase Center of High-Resolution TanDEM-X Data
The estimation of forestry parameters is essential to understanding the three-dimensional structure of forests. In this respect, the potential of X-band synthetic aperture radar (SAR) has been recognized for years. Many studies have been conducted on deriving tree heights with SAR data, but few have paid attention to the effects of the canopy structure. Canopy density plays an important role since it provides information about the vertical distribution of dominant scatterers in the forest. In this study, the position of the scattering phase center (SPC) of interferometric X-band SAR data is investigated with regard to the densest vegetation layer in a deciduous and coniferous forest in Germany by applying a canopy density index from high-resolution airborne laser scanning data. Two different methods defining the densest layer are introduced and compared with the position of the TanDEM-X SPC. The results indicate that the position of the SPC often coincides with the densest layer, with mean differences ranging from −1.6 m to +0.7 m in the deciduous forest and +1.9 m in the coniferous forest. Regarding relative tree heights, the SAR signal on average penetrates up to 15% (3.4 m) of the average tree height in the coniferous forest. In the deciduous forest, the difference increases to 18% (6.2 m) during summer and 24% (8.2 m) during winter. These findings highlight the importance of considering not only tree height but also canopy density when delineating SAR-based forest heights. The vertical structure of the canopy influences the position of the SPC, and incorporating canopy density can improve the accuracy of SAR-derived forest height estimations.
- 18 July 2023
- Published by MDPI AG in Remote Sensing
- Vol. 15 (14) , 3589
Open AccessRelationship between Lidar-Derived Canopy Densities and the Scattering Phase Center of High-Resolution TanDEM-X Data
The estimation of forestry parameters is essential to understanding the three-dimensional structure of forests. In this respect, the potential of X-band synthetic aperture radar (SAR) has been recognized for years. Many studies have been conducted on deriving tree heights with SAR data, but few have paid attention to the effects of the canopy structure. Canopy density plays an important role since it provides information about the vertical distribution of dominant scatterers in the forest. In this study, the position of the scattering phase center (SPC) of interferometric X-band SAR data is investigated with regard to the densest vegetation layer in a deciduous and coniferous forest in Germany by applying a canopy density index from high-resolution airborne laser scanning data. Two different methods defining the densest layer are introduced and compared with the position of the TanDEM-X SPC. The results indicate that the position of the SPC often coincides with the densest layer, with mean differences ranging from −1.6 m to +0.7 m in the deciduous forest and +1.9 m in the coniferous forest. Regarding relative tree heights, the SAR signal on average penetrates up to 15% (3.4 m) of the average tree height in the coniferous forest. In the deciduous forest, the difference increases to 18% (6.2 m) during summer and 24% (8.2 m) during winter. These findings highlight the importance of considering not only tree height but also canopy density when delineating SAR-based forest heights. The vertical structure of the canopy influences the position of the SPC, and incorporating canopy density can improve the accuracy of SAR-derived forest height estimations.
- Open Access
- 8 May 2023
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 120 (20)
Melt rates in the kilometer-size grounding zone of Petermann Glacier, Greenland, before and during a retreat
Warming of the ocean waters surrounding Greenland plays a major role in driving glacier retreat and the contribution of glaciers to sea level rise. The melt rate at the junction of the ocean with grounded ice—or grounding line—is, however, not well known. Here, we employ a time series of satellite radar interferometry data from the German TanDEM-X mission, the Italian COSMO-SkyMed constellation, and the Finnish ICEYE constellation to document the grounding line migration and basal melt rates of Petermann Glacier, a major marine-based glacier of Northwest Greenland. We find that the grounding line migrates at tidal frequencies over a kilometer-wide (2 to 6 km) grounding zone, which is one order of magnitude larger than expected for grounding lines on a rigid bed. The highest ice shelf melt rates are recorded within the grounding zone with values from 60 ± 13 to 80 ± 15 m/y along laterally confined channels. As the grounding line retreated by 3.8 km in 2016 to 2022, it carved a cavity about 204 m in height where melt rates increased from 40 ± 11 m/y in 2016 to 2019 to 60 ± 15 m/y in 2020 to 2021. In 2022, the cavity remained open during the entire tidal cycle. Such high melt rates concentrated in kilometer-wide grounding zones contrast with the traditional plume model of grounding line melt which predicts zero melt. High rates of simulated basal melting in grounded glacier ice in numerical models will increase the glacier sensitivity to ocean warming and potentially double projections of sea level rise.
- 8 May 2023
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 120 (20)
Open AccessMelt rates in the kilometer-size grounding zone of Petermann Glacier, Greenland, before and during a retreat
Warming of the ocean waters surrounding Greenland plays a major role in driving glacier retreat and the contribution of glaciers to sea level rise. The melt rate at the junction of the ocean with grounded ice—or grounding line—is, however, not well known. Here, we employ a time series of satellite radar interferometry data from the German TanDEM-X mission, the Italian COSMO-SkyMed constellation, and the Finnish ICEYE constellation to document the grounding line migration and basal melt rates of Petermann Glacier, a major marine-based glacier of Northwest Greenland. We find that the grounding line migrates at tidal frequencies over a kilometer-wide (2 to 6 km) grounding zone, which is one order of magnitude larger than expected for grounding lines on a rigid bed. The highest ice shelf melt rates are recorded within the grounding zone with values from 60 ± 13 to 80 ± 15 m/y along laterally confined channels. As the grounding line retreated by 3.8 km in 2016 to 2022, it carved a cavity about 204 m in height where melt rates increased from 40 ± 11 m/y in 2016 to 2019 to 60 ± 15 m/y in 2020 to 2021. In 2022, the cavity remained open during the entire tidal cycle. Such high melt rates concentrated in kilometer-wide grounding zones contrast with the traditional plume model of grounding line melt which predicts zero melt. High rates of simulated basal melting in grounded glacier ice in numerical models will increase the glacier sensitivity to ocean warming and potentially double projections of sea level rise.
- Open Access
- 16 August 2022
- Published by MDPI AG in Remote Sensing
- Vol. 14 (16) , 3981
Deep Learning for Mapping Tropical Forests with TanDEM-X Bistatic InSAR Data
The TanDEM-X synthetic aperture radar (SAR) system allows for the recording of bistatic interferometric SAR (InSAR) acquisitions, which provide additional information to the common amplitude images acquired by monostatic SAR systems. More concretely, the volume decorrelation factor, which can be derived from the bistatic interferometric coherence, is a reliable indicator of the presence of vegetation and it was used as main input feature for the generation of the global TanDEM-X forest/non-forest map, by means of a clustering algorithm. In this work, we investigate the capabilities of deep Convolutional Neural Networks (CNNs) for mapping tropical forests at large-scale using TanDEM-X InSAR data. For this purpose, we rely on a U-Net architecture, which takes as input a set of feature maps selected on the basis of previous preparatory works. Moreover, we design an ad hoc training strategy, aimed at developing a robust model for global mapping purposes, which has to properly manage the large variety of different acquisition geometries characterizing the TanDEM-X global data set. In addition to detecting forest/non-forest areas, the CNN has also been trained to detect water surfaces, which are typically characterized by low values of coherence. By applying the proposed method on single TanDEM-X images, we achieved a significant performance improvement with respect to the baseline clustering approach, with an average F-score increase of 0.13. We then applied such a model for mapping the entire Amazon rainforest, as well as the other tropical forests in Central Africa and South-East Asia, in order to test its robustness and generalization capabilities, and we observed that forests are typically well detected as contour closed regions and that water classification is reliable, too. Finally, the generated maps show a great potential for mapping temporal changes occurring over forested areas and can be used for generating large-scale maps of deforestation.
- 16 August 2022
- Published by MDPI AG in Remote Sensing
- Vol. 14 (16) , 3981
Open AccessDeep Learning for Mapping Tropical Forests with TanDEM-X Bistatic InSAR Data
The TanDEM-X synthetic aperture radar (SAR) system allows for the recording of bistatic interferometric SAR (InSAR) acquisitions, which provide additional information to the common amplitude images acquired by monostatic SAR systems. More concretely, the volume decorrelation factor, which can be derived from the bistatic interferometric coherence, is a reliable indicator of the presence of vegetation and it was used as main input feature for the generation of the global TanDEM-X forest/non-forest map, by means of a clustering algorithm. In this work, we investigate the capabilities of deep Convolutional Neural Networks (CNNs) for mapping tropical forests at large-scale using TanDEM-X InSAR data. For this purpose, we rely on a U-Net architecture, which takes as input a set of feature maps selected on the basis of previous preparatory works. Moreover, we design an ad hoc training strategy, aimed at developing a robust model for global mapping purposes, which has to properly manage the large variety of different acquisition geometries characterizing the TanDEM-X global data set. In addition to detecting forest/non-forest areas, the CNN has also been trained to detect water surfaces, which are typically characterized by low values of coherence. By applying the proposed method on single TanDEM-X images, we achieved a significant performance improvement with respect to the baseline clustering approach, with an average F-score increase of 0.13. We then applied such a model for mapping the entire Amazon rainforest, as well as the other tropical forests in Central Africa and South-East Asia, in order to test its robustness and generalization capabilities, and we observed that forests are typically well detected as contour closed regions and that water classification is reliable, too. Finally, the generated maps show a great potential for mapping temporal changes occurring over forested areas and can be used for generating large-scale maps of deforestation.
- Open Access
- 26 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 15 (19391404) , 3504-3518
On the Derivation of Volume Decorrelation From TanDEM-X Bistatic Coherence
The bistatic interferometric coherence is affected by different sources of error, among which volume decorrelation, which quantifies the amount of noise caused by volume scattering mechanisms. The magnitude of volume decorrelation can be derived from the total interferometric coherence by properly compensating for all other decorrelation sources. In the scientific community, it is common practice to approximate the volume decorrelation with the coherence or to compute it by compensating for the signal-to-noise ratio (SNR) decorrelation only, which typically represents the predominant decorrelation component. The aim of this work is to assess the impact of different decorrelation sources in detail and to provide the readers with a practical procedure for a precise computation of the volume decorrelation from TanDEM-X bistatic data. In particular, we concentrate on the two most relevant decorrelation components: the SNR and the quantization components. Regarding the former, we estimate the noise equivalent sigma nought directly from real SAR data and we provide the users with a set of polynomial coefficients for the retrieval of the system noise floor for each operational TanDEM-X StripMap beam used for the generation of the global Digital Elevation Model (DEM). Concerning the latter, we analyze its dependency on the backscatter local statistics and quantization rate and we provide the reader with a set of empirical look-up-tables (LUT) for quantifying its impact on the coherence. Finally, we provide reasonable assumptions for all other remaining decorrelation sources, discussing two application scenarios.
- 26 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 15 (19391404) , 3504-3518
Open AccessOn the Derivation of Volume Decorrelation From TanDEM-X Bistatic Coherence
The bistatic interferometric coherence is affected by different sources of error, among which volume decorrelation, which quantifies the amount of noise caused by volume scattering mechanisms. The magnitude of volume decorrelation can be derived from the total interferometric coherence by properly compensating for all other decorrelation sources. In the scientific community, it is common practice to approximate the volume decorrelation with the coherence or to compute it by compensating for the signal-to-noise ratio (SNR) decorrelation only, which typically represents the predominant decorrelation component. The aim of this work is to assess the impact of different decorrelation sources in detail and to provide the readers with a practical procedure for a precise computation of the volume decorrelation from TanDEM-X bistatic data. In particular, we concentrate on the two most relevant decorrelation components: the SNR and the quantization components. Regarding the former, we estimate the noise equivalent sigma nought directly from real SAR data and we provide the users with a set of polynomial coefficients for the retrieval of the system noise floor for each operational TanDEM-X StripMap beam used for the generation of the global Digital Elevation Model (DEM). Concerning the latter, we analyze its dependency on the backscatter local statistics and quantization rate and we provide the reader with a set of empirical look-up-tables (LUT) for quantifying its impact on the coherence. Finally, we provide reasonable assumptions for all other remaining decorrelation sources, discussing two application scenarios.
- Open Access
- 18 January 2022
- Published by MDPI AG in Remote Sensing
- Vol. 14 (3) , 452
An Effective Method for InSAR Mapping of Tropical Forest Degradation in Hilly Areas
Current satellite remote sensing methods struggle to detect and map forest degradation, which is a critical issue as it is likely a major and growing source of carbon emissions and biodiveristy loss. TanDEM-X InSAR phase height () is a promising variable for measuring forest disturbances, as it is closely related to the mean canopy height, and thus should decrease if canopy trees are removed. However, previous research has focused on relatively flat terrains, despite the fact that much of the world’s remaining tropical forests are found in hilly areas, and this inevitably introduces artifacts in sideways imaging systems. In this paper, we find a relationship between and aboveground biomass change in four selectively logged plots in a hilly region of central Gabon. We show that minimising multilooking prior to the calculation of strengthens this relationship, and that degradation estimates across steep slopes in the surrounding region are improved by selecting data from the most appropriate pass directions on a pixel-by-pixel basis. This shows that TanDEM-X InSAR can measure the magnitude of degradation, and that topographic effects can be mitigated if data from multiple SAR viewing geometries are available.- 18 January 2022
- Published by MDPI AG in Remote Sensing
- Vol. 14 (3) , 452
Open AccessAn Effective Method for InSAR Mapping of Tropical Forest Degradation in Hilly Areas
Current satellite remote sensing methods struggle to detect and map forest degradation, which is a critical issue as it is likely a major and growing source of carbon emissions and biodiveristy loss. TanDEM-X InSAR phase height () is a promising variable for measuring forest disturbances, as it is closely related to the mean canopy height, and thus should decrease if canopy trees are removed. However, previous research has focused on relatively flat terrains, despite the fact that much of the world’s remaining tropical forests are found in hilly areas, and this inevitably introduces artifacts in sideways imaging systems. In this paper, we find a relationship between and aboveground biomass change in four selectively logged plots in a hilly region of central Gabon. We show that minimising multilooking prior to the calculation of strengthens this relationship, and that degradation estimates across steep slopes in the surrounding region are improved by selecting data from the most appropriate pass directions on a pixel-by-pixel basis. This shows that TanDEM-X InSAR can measure the magnitude of degradation, and that topographic effects can be mitigated if data from multiple SAR viewing geometries are available.