YDYanran Du

Yanran Du

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yanran Du has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    How AI Responds to Obstetric Ultrasound Questions and Analyzes and Explains Obstetric Ultrasound Reports: ChatGPT-3.5 vs. Microsoft Copilot in Bing

    by Yanran Du, Chao Ji, Jiale Xu, Minyan Wei, Yunyun Ren, Shujun Xia, JianQiao Zhou

    Objectives: To evaluate and compare the accuracy and consistency of answers to obstetric ultrasound questions and analysis of obstetric ultrasound reports using publicly available ChatGPT-3.5 and Microsoft Copilot in Bing (Copilot). Methods: Twenty questions related to obstetric ultrasound were answered and 110 obstetric ultrasound reports were analyzed by both ChatGPT-3.5 and Copilot, with each question and report being posed three times to them at different times. The accuracy and consistency of each response to twenty questions and each analysis result in the report were evaluated and compared. Results: In answering twenty questions, ChatGPT-3.5 outperformed Copilot in both accuracy (95.0% vs. 80.0%) and consistency (90.0% vs. 75.0%). When analyzing obstetric ultrasound reports, two models performed similarly in accuracy and consistency, and can provide recommendations. The overall accuracy and consistency of ChatGPT-3.5 and Copilot were 83.86%, 87.30% vs 77.51%, 90.48%, respectively. However, in detecting abnormal amniotic fluid index, ChatGPT-3.5 was superior to Copilot (accuracy 87.50% vs. 66.67%, P < 0.05). Conclusion: While ChatGPT-3.5 and Copilot can provide valuable explanations on obstetric ultrasound and interpret most obstetric ultrasound reports accurately, neither model consistently answered all questions correctly or with complete consistency, the supervision of physician is crucial in the use of these models.

  • Ultrasound‐based radiomics for the evaluation of fetal rat lung maturity: A noninvasive assessment method (Ultrasound‐based radiomics in fetal rat lung)

    by Yanran Du, Jing Jiao, Aili Cao, Chao Ji, Man Li, Chenli Ji, Yang Wu, Yi Guo, Yuanyuan Wang, Jianqiao Zhou, et al.

    Objective: To establish a classification model for the evaluation of rat fetal lung maturity (FLM) using radiomics technology.Method: A total of 430 high‐throughput features were extracted per fetal lung image from 134 fetal lung ultrasound images (four‐cardiac‐chamber views) of 67 Sprague–Dawley (SD) fetal rats with a gestational age of 16–21 days. The detection of fetal lung tissues included histopathological staining and the expression of surface proteins SP‐A, SP‐B, and SP‐C. A machine learning classification model was established using a support vector machine based on histopathological results to analyze the relationship between fetal lung texture characteristics and FLM.Results: The rat fetal lungs were divided into two groups: terminal sac period (SD1) and canalicular period (SD2). The mRNA transcription and protein expression level of SP‐C protein were significantly higher in the SD1 group than in the SD2 group (p < 0.05). The diagnostic performance of the rat FLM classification model was measured as follows: area under the receiver operating characteristic curve (AUC), 0.93 (training set) and 0.89 (validation set); sensitivity, 89.26% (training set) and 87.10% (validation set); specificity, 85.87% (training set) and 79.17% (validation set); and accuracy, 87.79% (training set) and 83.64% (validation set).Conclusion: Ultrasound‐based radiomics technology can be used to evaluate the FLM of rats, which lays a foundation for further research on this technology in human fetal lungs.


  • Open Access

    Prenatal prediction of neonatal respiratory morbidity: a radiomics method based on imbalanced few-shot fetal lung ultrasound images

    by Jing Jiao, Yanran Du, Xiaokang Li, Yi Guo, Yunyun Ren, Yuanyuan Wang

    Background: To develop a non-invasive method for the prenatal prediction of neonatal respiratory morbidity (NRM) by a novel radiomics method based on imbalanced few-shot fetal lung ultrasound images. Methods: A total of 210 fetal lung ultrasound images were enrolled in this study, including 159 normal newborns and 51 NRM newborns. Fetal lungs were delineated as the region of interest (ROI), where radiomics features were designed and extracted. Integrating radiomics features selected and two clinical features, including gestational age and gestational diabetes mellitus, the prediction model was developed and evaluated. The modelling methods used were data augmentation, cost-sensitive learning, and ensemble learning. Furthermore, two methods, which embed data balancing into ensemble learning, were employed to address the problems of imbalance and few-shot simultaneously. Results: Our model achieved sensitivity values of 0.82, specificity values of 0.84, balanced accuracy values of 0.83 and area under the curve values of 0.87 in the test set. The radiomics features extracted from the ROIs at different locations within the lung region achieved similar classification performance outcomes. Conclusion: The feature set we designed can efficiently and robustly describe fetal lungs for NRM prediction. RUSBoost shows excellent performance compared to state-of-the-art classifiers on the imbalanced few-shot dataset. The diagnostic efficacy of the model we developed is similar to that of several previous reports of amniocentesis and can serve as a non-invasive, precise evaluation tool for NRM prediction.


  • Application of ultrasound‐based radiomics technology in fetal‐lung‐texture analysis in pregnancies complicated by gestational diabetes and/or pre‐eclampsia

    by Yanran Du, Zhou Fang, J. Jiao, Guannan Xi, Chen Zhu, Yunyun Ren, Y. Guo, Yuanyuan Wang

    Objectives: To analyze and compare, using ultrasound‐based radiomics technology, fetal‐lung texture in pregnancies affected by gestational diabetes mellitus (GDM) and/or pre‐eclampsia (PE) and in normal pregnancies, overall and at different gestational ages.Methods: In this retrospective study, 430 high‐throughput features per fetal‐lung image were extracted from 548 fetal‐lung ultrasound images (obtained at the level of the four‐chamber view of the heart) in 548 pregnant women who delivered between July 2018 and August 2019 at the Obstetrics and Gynecology Hospital of Fudan University. Images had been obtained during ultrasound examinations between 28 and 41 weeks of gestation. The data were divided randomly into training set (80% of fetal‐lung images) and independent test set (20% of images), and 20% of the images in the training set were then selected as the validation set. A standard machine‐learning model based on ultrasound‐based radiomics technology was created using features of fetal‐lung texture extracted from the images, and a regression model was used to evaluate the relationship between lung‐texture features, GDM and/or PE and gestational age.Results: Of the 548 pregnancies included, 108 were affected by GDM alone, 71 by PE alone and 25 by both GDM and PE, and 344 were normal. The overall performance of the GDM and PE prediction model was superior to that of the gestational‐age prediction model, with an area under the receiver‐operating‐characteristics curve of 0.95–0.99, sensitivity of 78.8–97.1% in the validation set and 74.5–91.3% in the independent test set, specificity of 79.8–94.3% in the validation set and 75.7–88.4% in the independent test set and accuracy of 81.0–95.3% in the validation set and 80.6–86.4% in the independent test set.Conclusions: Using ultrasound‐based radiomics technology, fetal lungs from pregnancies grouped according to whether they were affected by GDM and/or PE could be distinguished from each other and from fetal lungs of normal pregnancies, and lungs from pregnancies at different gestational ages could be distinguished. These findings support further research to explore the use of this non‐invasive technology to predict neonatal respiratory complications in women with PE, GDM or their combination. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.