Paul R. P. Rushton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Paul R. P. Rushton has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
Michael P. Grevitt
Centre for Spinal Studies and Surgery, Queen's Medical Centre, Nottingham, NG7 2UH, UK
6 shared publicationsAndrew J. Bowey
Great North Children’s Hospital, Royal Victoria Infirmary, Newcastle upon Tyne, UK
3 shared publicationsSimon L. Smith
School of Mechanical and Systems Engineering, Newcastle University, Newcastle upon Tyne, UK
3 shared publicationsDavid Fender
Great North Children’s Hospital, Royal Victoria Infirmary, Newcastle upon Tyne, UK
2 shared publicationsMichael J. Gibson
Orthopaedic Spinal Surgeon, Newcastle upon Tyne, UK
2 shared publicationsThomas J. Joyce
School of Mechanical and Systems Engineering, Newcastle University, Newcastle upon Tyne, UK
2 shared publications
Latest Publications
- 16 June 2021
- Published by Springer Nature in Spine Deformity
- Vol. 9 (6) , 1549-1557
What is the effect of intraoperative traction on correction of adolescent idiopathic scoliosis (AIS)?
Purpose Determine the efficacy of intraoperative traction (IOT) on curve correction in AIS. Methods A prospective, multicenter, longitudinal database identified patients with major thoracic AIS (Lenke 1–4) treated with surgery using IOT and follow-up of 2 years. These cases were matched to comparable cases treated without traction (non-IOT). All patients were treated with single-stage posterior only surgery with pedicle screw constructs. Perioperative, radiographic and clinical outcome data at 2 years post-op were compared between the groups. Results 104 cases treated with IOT were matched to 104 treated without IOT. Operating room time was significantly greater in the IOT group (339 vs. 306 min, p = < 0.001). Neuromonitoring alerts were more frequent in the IOT group (23% vs. 5%, p < 0.001). There were no postoperative neurological deficits in either group. The IOT group showed significantly greater MT curve correction (IOT 71% vs. non-IOT 66.7%, p < 0.003), with the effect most pronounced in curves > 70° (IOT 72% vs. non-IOT 64%, p = 0.04). IOT was associated with a significant reduction in 2D T5–T12 kyphosis measurements (IOT − 6.5° vs non-IOT + 0.48°, p < 0.001), yet significant improvements in estimated 3D thoracic kyphosis were made in both groups, with the non-IOT group making greater improvement when compared to the IOT group (IOT + 18.1° vs. non-IOT + 22.3° vs., p = 0.008). Conclusions IOT is associated with modestly enhanced coronal deformity correction. Surgeons should be aware of the increased rates of neuromonitoring alerts when using this technique and its affect on the sagittal profile. Given this IOT may be best suited to larger curves. Level of evidence 3.
- 16 June 2021
- Published by Springer Nature in Spine Deformity
- Vol. 9 (6) , 1549-1557
What is the effect of intraoperative traction on correction of adolescent idiopathic scoliosis (AIS)?
Purpose Determine the efficacy of intraoperative traction (IOT) on curve correction in AIS. Methods A prospective, multicenter, longitudinal database identified patients with major thoracic AIS (Lenke 1–4) treated with surgery using IOT and follow-up of 2 years. These cases were matched to comparable cases treated without traction (non-IOT). All patients were treated with single-stage posterior only surgery with pedicle screw constructs. Perioperative, radiographic and clinical outcome data at 2 years post-op were compared between the groups. Results 104 cases treated with IOT were matched to 104 treated without IOT. Operating room time was significantly greater in the IOT group (339 vs. 306 min, p = < 0.001). Neuromonitoring alerts were more frequent in the IOT group (23% vs. 5%, p < 0.001). There were no postoperative neurological deficits in either group. The IOT group showed significantly greater MT curve correction (IOT 71% vs. non-IOT 66.7%, p < 0.003), with the effect most pronounced in curves > 70° (IOT 72% vs. non-IOT 64%, p = 0.04). IOT was associated with a significant reduction in 2D T5–T12 kyphosis measurements (IOT − 6.5° vs non-IOT + 0.48°, p < 0.001), yet significant improvements in estimated 3D thoracic kyphosis were made in both groups, with the non-IOT group making greater improvement when compared to the IOT group (IOT + 18.1° vs. non-IOT + 22.3° vs., p = 0.008). Conclusions IOT is associated with modestly enhanced coronal deformity correction. Surgeons should be aware of the increased rates of neuromonitoring alerts when using this technique and its affect on the sagittal profile. Given this IOT may be best suited to larger curves. Level of evidence 3.
- Open Access
- 4 June 2021
- Published by Wolters Kluwer Health in Spine
- Vol. 46 (21) , 1461-1467
Anterior Vertebral Body Tethering for Treatment of Idiopathic Scoliosis in the Skeletally Immature
Study Design.: Prospective case series. Objective.: Determine the efficacy of anterior vertebral body tethering (AVBT) in skeletally immature patients. Summary of Background Data.: The value of AVBT is currently unclear given the paucity of available data. Methods.: Consecutive skeletally immature patients with idiopathic scoliosis were treated with AVBT between 2012 and 2018 by one of two surgeons working at two independent centers and followed up for >2 years. Data were collected prospectively and supplemented retrospectively where necessary. Outcomes were measured preoperatively, at first erect radiograph (FE), 1-year postoperatively and at most recent follow up (FU). Results.: One hundred twelve patients underwent 116 primary tethering procedures (108 thoracic and eight lumbar tethers). Four patients had primary tethering of both lumbar and thoracic curves. At surgery mean age was 12.7 ± 1.4 years (8.2–16.7) and Risser 0.5 ± 0.9 (0–3). Follow up was mean 37 ± 9 months (15–64). Preoperative mean coronal Cobb angle of the 130 tethered curves was 50.8° ± 10.2 (31–81) and corrected significantly to 26.6° ± 10.1 (−3–61) at FE radiograph (P < 0.001). Further significant improvement was seen from FE to 1-year, to mean 23.1° ± 12.4 (−37–57) (P < 0.001). There was a small but significant increase between 1-year and FU to 25.7° ± 16.3 (−32–58) (P < 0.001), which appeared to reflect tether breakage. Untethered minor curves were corrected from 31.0° ± 9.5 (3–57) to 20.3° ± 10.3 (0–52) at FU (P < 0.001). Rib hump was corrected from 14.1 ± 4.8 (0–26) to 8.8° ± 5.4 (0–22) at FU (P < 0.01). Twenty-five patients (22%) had 28 complications. Fifteen patients (13%) requiring 18 revision operations including six completed and one awaited fusions. Conclusion.: AVBT of immature cases is associated with satisfactory deformity correction in the majority of cases. However, complication and revision rates suggest the need for improved implants and patient selection. Long-term follow-up remains crucial to establish the true efficacy of this procedure. Level of Evidence: 3
- 4 June 2021
- Published by Wolters Kluwer Health in Spine
- Vol. 46 (21) , 1461-1467
Open AccessAnterior Vertebral Body Tethering for Treatment of Idiopathic Scoliosis in the Skeletally Immature
Study Design.: Prospective case series. Objective.: Determine the efficacy of anterior vertebral body tethering (AVBT) in skeletally immature patients. Summary of Background Data.: The value of AVBT is currently unclear given the paucity of available data. Methods.: Consecutive skeletally immature patients with idiopathic scoliosis were treated with AVBT between 2012 and 2018 by one of two surgeons working at two independent centers and followed up for >2 years. Data were collected prospectively and supplemented retrospectively where necessary. Outcomes were measured preoperatively, at first erect radiograph (FE), 1-year postoperatively and at most recent follow up (FU). Results.: One hundred twelve patients underwent 116 primary tethering procedures (108 thoracic and eight lumbar tethers). Four patients had primary tethering of both lumbar and thoracic curves. At surgery mean age was 12.7 ± 1.4 years (8.2–16.7) and Risser 0.5 ± 0.9 (0–3). Follow up was mean 37 ± 9 months (15–64). Preoperative mean coronal Cobb angle of the 130 tethered curves was 50.8° ± 10.2 (31–81) and corrected significantly to 26.6° ± 10.1 (−3–61) at FE radiograph (P < 0.001). Further significant improvement was seen from FE to 1-year, to mean 23.1° ± 12.4 (−37–57) (P < 0.001). There was a small but significant increase between 1-year and FU to 25.7° ± 16.3 (−32–58) (P < 0.001), which appeared to reflect tether breakage. Untethered minor curves were corrected from 31.0° ± 9.5 (3–57) to 20.3° ± 10.3 (0–52) at FU (P < 0.001). Rib hump was corrected from 14.1 ± 4.8 (0–26) to 8.8° ± 5.4 (0–22) at FU (P < 0.01). Twenty-five patients (22%) had 28 complications. Fifteen patients (13%) requiring 18 revision operations including six completed and one awaited fusions. Conclusion.: AVBT of immature cases is associated with satisfactory deformity correction in the majority of cases. However, complication and revision rates suggest the need for improved implants and patient selection. Long-term follow-up remains crucial to establish the true efficacy of this procedure. Level of Evidence: 3
- 5 February 2021
- Published by Springer Nature in European Spine Journal
- Vol. 30 (7) , 1905-1911
Metallosis is commonly associated with magnetically controlled growing rods; results from an independent multicentre explant database
Purpose Determine the incidence of metallosis around MAGEC rods. Methods A multicentre explant database was searched to identify cases with complete intraoperative findings at rod removal. Surgeons removing rods detailed the presence or absence of tissue metallosis associated with rods. More recently surgeons measured the ‘length’ of tissue metallosis. Prior to rod disassembly, the majority underwent testing with an external remote controller (ERC). The impact of clinical and explant variables on metallosis was assessed. Results Sixty-six cases were identified. Mean age at insertion was 8.1 ± 2.3 years with mean duration of implantation 37.6 ± 15.1 months. Tissue metallosis was noted at revision surgery in 52/66 cases (79%). Metallosis was noted more commonly when rods were removed during fusion surgery than rod removal/exchange (97% vs. 58% (p = < 0.01)). The mass at insertion was greater in cases with metallosis (25.9 ± 7.8 kg vs. 21.1 ± 6.2 kg, p = 0.04). Length of tissue metallosis was reported for 45 rods, median 9 cm (range 1–25). Metallosis was noted in 43/59 (73%) rods that produced no force and 22/30 (73%) rods that produced some force on ERC activation (p = 0.96). Wear debris was found within the actuator in all rods, and all but 3 rods had damaged O-rings. Conclusion MAGEC rods are associated with tissue metallosis in the majority of cases. It is seen with functional rods as well as failed rods and appears related to wear debris within the actuator and high rates of O-ring failure. Until the implications of metal debris in children are known, we urge caution with the use of this implant.
- 5 February 2021
- Published by Springer Nature in European Spine Journal
- Vol. 30 (7) , 1905-1911
Metallosis is commonly associated with magnetically controlled growing rods; results from an independent multicentre explant database
Purpose Determine the incidence of metallosis around MAGEC rods. Methods A multicentre explant database was searched to identify cases with complete intraoperative findings at rod removal. Surgeons removing rods detailed the presence or absence of tissue metallosis associated with rods. More recently surgeons measured the ‘length’ of tissue metallosis. Prior to rod disassembly, the majority underwent testing with an external remote controller (ERC). The impact of clinical and explant variables on metallosis was assessed. Results Sixty-six cases were identified. Mean age at insertion was 8.1 ± 2.3 years with mean duration of implantation 37.6 ± 15.1 months. Tissue metallosis was noted at revision surgery in 52/66 cases (79%). Metallosis was noted more commonly when rods were removed during fusion surgery than rod removal/exchange (97% vs. 58% (p = < 0.01)). The mass at insertion was greater in cases with metallosis (25.9 ± 7.8 kg vs. 21.1 ± 6.2 kg, p = 0.04). Length of tissue metallosis was reported for 45 rods, median 9 cm (range 1–25). Metallosis was noted in 43/59 (73%) rods that produced no force and 22/30 (73%) rods that produced some force on ERC activation (p = 0.96). Wear debris was found within the actuator in all rods, and all but 3 rods had damaged O-rings. Conclusion MAGEC rods are associated with tissue metallosis in the majority of cases. It is seen with functional rods as well as failed rods and appears related to wear debris within the actuator and high rates of O-ring failure. Until the implications of metal debris in children are known, we urge caution with the use of this implant.
- 1 February 2020
- Published by Wolters Kluwer Health in Spine
- Vol. 45 (3) , 170-176
Spinal Lengthening With Magnetically Controlled Growing Rods
Study Design.: Laboratory analysis of explanted MAGnetic Expansion Control (MAGEC) rods. Objective.: The aim of this study was to identify the in vivo lengthening of MAGEC rods. Summary of Background Data.: Little data is available regarding the lengthening achieved by MAGEC rods. Methods.: Cases were identified from the largest series of independently analyzed explanted MAGEC rods. The in vivo growth of rods was determined by the distance between the first “growth mark” and the actuator. The instrumented spinal lengthening was calculated for each construct. Constructs were considered functional if all rods could lengthen with external remote controller activation and no rods were “telescoping”. Results.: Fifty-five MAGEC constructs (99 rods) from 53 patients treated at 10 centers were included. The mean age at insertion was 8.5 years with rods implanted a mean of 35 months. Sixty rods were suitable for analysis with mean lengthening 21.7 mm, 8.9 mm/year. Of these 60 rods, three were maximally distracted. Mean instrumented spinal lengthening for 38 suitable cases was 22.1 mm, 8.4 mm/year. This was positively correlated with the duration of implantation (r = 0.34, P = 0.04) but negatively with patient age at insertion (r = −0.35, P = 0.03). The rate of instrumented spinal lengthening was negatively correlated with duration of implantation (r = −0.47, P = 0.004). Of 55 constructs, 34 were nonfunctional at time of removal with nine functional and 12 indeterminate. Functional constructs had been implanted significantly less time (20.0 vs. 39.7 months, P < 0.001) and lengthened less than those nonfunctional (12.3 mm vs. 23.3 mm, P = 0.04). Conclusion.: This multicenter explant study represents the largest cohort managed with MAGEC rods reported. Rods are very rarely removed having fully lengthened with mean instrumented spinal growth of 22 mm over the implant's life. This may be explained by a high rate of lengthening mechanism failure in received rods after around 3 years in vivo. Our findings question the effectiveness of the MAGEC system and mandate urgent comparative clinical studies. Level of Evidence: 4
- 1 February 2020
- Published by Wolters Kluwer Health in Spine
- Vol. 45 (3) , 170-176
Spinal Lengthening With Magnetically Controlled Growing Rods
Study Design.: Laboratory analysis of explanted MAGnetic Expansion Control (MAGEC) rods. Objective.: The aim of this study was to identify the in vivo lengthening of MAGEC rods. Summary of Background Data.: Little data is available regarding the lengthening achieved by MAGEC rods. Methods.: Cases were identified from the largest series of independently analyzed explanted MAGEC rods. The in vivo growth of rods was determined by the distance between the first “growth mark” and the actuator. The instrumented spinal lengthening was calculated for each construct. Constructs were considered functional if all rods could lengthen with external remote controller activation and no rods were “telescoping”. Results.: Fifty-five MAGEC constructs (99 rods) from 53 patients treated at 10 centers were included. The mean age at insertion was 8.5 years with rods implanted a mean of 35 months. Sixty rods were suitable for analysis with mean lengthening 21.7 mm, 8.9 mm/year. Of these 60 rods, three were maximally distracted. Mean instrumented spinal lengthening for 38 suitable cases was 22.1 mm, 8.4 mm/year. This was positively correlated with the duration of implantation (r = 0.34, P = 0.04) but negatively with patient age at insertion (r = −0.35, P = 0.03). The rate of instrumented spinal lengthening was negatively correlated with duration of implantation (r = −0.47, P = 0.004). Of 55 constructs, 34 were nonfunctional at time of removal with nine functional and 12 indeterminate. Functional constructs had been implanted significantly less time (20.0 vs. 39.7 months, P < 0.001) and lengthened less than those nonfunctional (12.3 mm vs. 23.3 mm, P = 0.04). Conclusion.: This multicenter explant study represents the largest cohort managed with MAGEC rods reported. Rods are very rarely removed having fully lengthened with mean instrumented spinal growth of 22 mm over the implant's life. This may be explained by a high rate of lengthening mechanism failure in received rods after around 3 years in vivo. Our findings question the effectiveness of the MAGEC system and mandate urgent comparative clinical studies. Level of Evidence: 4
- 1 January 2018
- Published by Wolters Kluwer Health in Spine
- Vol. 43 (1) , E16-E22
Analysis of Explanted Magnetically Controlled Growing Rods From Seven UK Spinal Centers
Analysis of explanted MAGnetic Expansion Control (MAGEC) growing rods. To analyze explanted MAGEC rods used in management of early onset scoliosis and identify the mode of failure in such cases. Magnetically controlled growing rods are increasingly used as the option of choice for early onset scoliosis. However, being more complex than conventional growing rods they are perhaps more likely to succumb to multifarious failure modes. In addition, metallosis has been reported around failed MAGEC rods. Explanted MAGEC rods from 7 UK spinal centers were obtained for independent analysis. Thirty-four MAGEC rods, from 18 children, explanted for reasons including failure of rod lengthening and maximum rod distraction reached, were cut open to allow internal components to be evaluated and assessed. Externally, all MAGEC rods showed localized marks, which were termed ‘growth marks’ as they indicated growth of the rod in vivo, on the extending bar component. After cutting open, titanium wear debris was found inside all 34 (100%) MAGEC rods. Ninety-one percent (31/34) of MAGEC rods showed measurable wear of the extending bar, towards the magnet end. Substantial damage to the radial bearing was seen inside 74% (25/34) of MAGEC rods while O-ring seal failure was seen in 53% (18/34) of cases. In 44% (15/34) of MAGEC rods the drive pin was fractured but this was felt to be an effect of rod failure, not a cause. The combination of high volumes of titanium wear debris alongside O-ring seal damage likely accounts for the metallosis reported clinically around some MAGEC rods. Based on this explant data, a failure mechanism in MAGEC rods due to the natural off axis loading in the spine was proposed. This is the largest data set reporting a complete analysis of explanted MAGEC rods to date. Level of Evidence: 4
- 1 January 2018
- Published by Wolters Kluwer Health in Spine
- Vol. 43 (1) , E16-E22
Analysis of Explanted Magnetically Controlled Growing Rods From Seven UK Spinal Centers
Analysis of explanted MAGnetic Expansion Control (MAGEC) growing rods. To analyze explanted MAGEC rods used in management of early onset scoliosis and identify the mode of failure in such cases. Magnetically controlled growing rods are increasingly used as the option of choice for early onset scoliosis. However, being more complex than conventional growing rods they are perhaps more likely to succumb to multifarious failure modes. In addition, metallosis has been reported around failed MAGEC rods. Explanted MAGEC rods from 7 UK spinal centers were obtained for independent analysis. Thirty-four MAGEC rods, from 18 children, explanted for reasons including failure of rod lengthening and maximum rod distraction reached, were cut open to allow internal components to be evaluated and assessed. Externally, all MAGEC rods showed localized marks, which were termed ‘growth marks’ as they indicated growth of the rod in vivo, on the extending bar component. After cutting open, titanium wear debris was found inside all 34 (100%) MAGEC rods. Ninety-one percent (31/34) of MAGEC rods showed measurable wear of the extending bar, towards the magnet end. Substantial damage to the radial bearing was seen inside 74% (25/34) of MAGEC rods while O-ring seal failure was seen in 53% (18/34) of cases. In 44% (15/34) of MAGEC rods the drive pin was fractured but this was felt to be an effect of rod failure, not a cause. The combination of high volumes of titanium wear debris alongside O-ring seal damage likely accounts for the metallosis reported clinically around some MAGEC rods. Based on this explant data, a failure mechanism in MAGEC rods due to the natural off axis loading in the spine was proposed. This is the largest data set reporting a complete analysis of explanted MAGEC rods to date. Level of Evidence: 4
- 1 June 2017
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 99-B (6) , 708-713
Magnetically controlled growing rods in the treatment of early-onset scoliosis
The MAGnetic Expansion Control (MAGEC) system is used increasingly in the management of early-onset scoliosis. Good results have been published, but there have been recent reports identifying implant failures that may be associated with significant metallosis surrounding the implants. This article aims to present the current knowledge regarding the performance of this implant, and the potential implications and strategies that may be employed to identify and limit any problems. We urge surgeons to apply caution to patient and construct selection; engage in prospective patient registration using a spine registry; ensure close clinical monitoring until growth has ceased; and send all explanted MAGEC rods for independent analysis. The MAGEC system may be a good instrumentation system for the treatment of early-onset scoliosis. However, it is innovative and like all new technology, especially when deployed in a paediatric population, robust systems to assess long-term outcome are required to ensure that patient safety is maintained. Cite this article: Bone Joint J 2017;99-B:708–13.
- 1 June 2017
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 99-B (6) , 708-713
Magnetically controlled growing rods in the treatment of early-onset scoliosis
The MAGnetic Expansion Control (MAGEC) system is used increasingly in the management of early-onset scoliosis. Good results have been published, but there have been recent reports identifying implant failures that may be associated with significant metallosis surrounding the implants. This article aims to present the current knowledge regarding the performance of this implant, and the potential implications and strategies that may be employed to identify and limit any problems. We urge surgeons to apply caution to patient and construct selection; engage in prospective patient registration using a spine registry; ensure close clinical monitoring until growth has ceased; and send all explanted MAGEC rods for independent analysis. The MAGEC system may be a good instrumentation system for the treatment of early-onset scoliosis. However, it is innovative and like all new technology, especially when deployed in a paediatric population, robust systems to assess long-term outcome are required to ensure that patient safety is maintained. Cite this article: Bone Joint J 2017;99-B:708–13.
- 6 May 2016
- Published by Springer Nature in European Spine Journal
- Vol. 26 (6) , 1652-1657
Intrathecal baclofen pumps do not accelerate progression of scoliosis in quadriplegic spastic cerebral palsy
Purpose To compare scoliosis progression in quadriplegic spastic cerebral palsy with and without intrathecal baclofen (ITB) pumps. Methods A retrospective matched cohort study was conducted. Patients with quadriplegic spastic cerebral palsy, GMFCS level 5, treated with ITB pumps with follow-up >1 year were matched to comparable cases by age and baseline Cobb angle without ITB pumps. Annual and peak coronal curve progression, pelvic obliquity progression and need for spinal fusion were compared. Results ITB group: 25 patients (9 female), mean age at pump insertion 9.4 and Risser 0.9. Initial Cobb angle 25.6° and pelvic tilt 3.2°. Follow-up 4.3 (1.0–7.8) years. Cobb angle at follow-up 76.1° and pelvic tilt 18.9°. Non-ITB group: 25 patients (14 female), mean age at baseline 9.2 and Risser 1.0. Initial Cobb angle 29.7° and pelvic tilt 7.1°. Follow-up 3.5 (1.0–7.5) years. Cobb angle at follow-up 69.1° and pelvic tilt 21.0°. The two groups were statistically similar for baseline age, Cobb angle and Risser grade. Mean curve progression was 13.6°/year for the ITB group vs 12.6°/year for the non-ITB group (p = 0.39). Peak curve progression was similar between the groups. Pelvic tilt progression was comparable; ITB group 4.5°/year vs non-ITB 4.6°/year (p = 0.97). During follow-up 5 patients in the ITB group and 9 in the non-ITB group required spinal fusion surgery for curve progression (p = 0.35). Conclusions Patients with quadriplegic spastic cerebral palsy with and without ITB pumps showed significant curve progression over time. ITB pumps do not appear to alter the natural history of curve progression in this population.
- 6 May 2016
- Published by Springer Nature in European Spine Journal
- Vol. 26 (6) , 1652-1657
Intrathecal baclofen pumps do not accelerate progression of scoliosis in quadriplegic spastic cerebral palsy
Purpose To compare scoliosis progression in quadriplegic spastic cerebral palsy with and without intrathecal baclofen (ITB) pumps. Methods A retrospective matched cohort study was conducted. Patients with quadriplegic spastic cerebral palsy, GMFCS level 5, treated with ITB pumps with follow-up >1 year were matched to comparable cases by age and baseline Cobb angle without ITB pumps. Annual and peak coronal curve progression, pelvic obliquity progression and need for spinal fusion were compared. Results ITB group: 25 patients (9 female), mean age at pump insertion 9.4 and Risser 0.9. Initial Cobb angle 25.6° and pelvic tilt 3.2°. Follow-up 4.3 (1.0–7.8) years. Cobb angle at follow-up 76.1° and pelvic tilt 18.9°. Non-ITB group: 25 patients (14 female), mean age at baseline 9.2 and Risser 1.0. Initial Cobb angle 29.7° and pelvic tilt 7.1°. Follow-up 3.5 (1.0–7.5) years. Cobb angle at follow-up 69.1° and pelvic tilt 21.0°. The two groups were statistically similar for baseline age, Cobb angle and Risser grade. Mean curve progression was 13.6°/year for the ITB group vs 12.6°/year for the non-ITB group (p = 0.39). Peak curve progression was similar between the groups. Pelvic tilt progression was comparable; ITB group 4.5°/year vs non-ITB 4.6°/year (p = 0.97). During follow-up 5 patients in the ITB group and 9 in the non-ITB group required spinal fusion surgery for curve progression (p = 0.35). Conclusions Patients with quadriplegic spastic cerebral palsy with and without ITB pumps showed significant curve progression over time. ITB pumps do not appear to alter the natural history of curve progression in this population.
- 10 December 2015
- Published by Springer Nature in European Spine Journal
- Vol. 25 (10) , 3324-3330
The effect of metal density in thoracic adolescent idiopathic scoliosis
Determine impact of metal density on curve correction and costs in thoracic adolescent idiopathic scoliosis (AIS). Ascertain if increased metal density is required for larger or stiffer curves. Multicentre retrospective case series of patients with Lenke 1-2 AIS treated with single-stage posterior only surgery using a standardized surgical technique; constructs using >80 % screws with variable metal density. All cases had >2-year follow up. Outcomes measures included coronal and sagittal radiographic outcomes, metal density (number of instrumented pedicles vs total available), fusion length and cost. 106 cases included 94 female. 78 Lenke 1. Mean age 14 years (9–26). Mean main thoracic (MT) Cobb angle 63° corrected to 22° (66 %). No significant correlations were present between metal density and: (a) coronal curve correction rates of the MT (r = 0.13, p = 0.19); (b) lumbar curve frontal correction (r = −0.15, p = 0.12); (c) correction index in MT curve (r = −0.10, p = 0.32); and (d) correction index in lumbar curve (r = 0.11, p = 0.28). Metal density was not correlated with change in thoracic kyphosis (r = 0.22, p = 0.04) or lumbosacral lordosis (r = 0.27, p = 0.01). Longer fusions were associated with greater loss of thoracic kyphosis (r = −0.31, p = 0.003). Groups differing by preoperative curve size and stiffness had comparable corrections with similar metal density. The pedicle screw cost represented 21–29 % of overall cost of inpatient treatment depending on metal density. Metal density affects cost but not the coronal and sagittal correction of thoracic AIS. Neither larger nor stiffer curves necessitate high metal density.
- 10 December 2015
- Published by Springer Nature in European Spine Journal
- Vol. 25 (10) , 3324-3330
The effect of metal density in thoracic adolescent idiopathic scoliosis
Determine impact of metal density on curve correction and costs in thoracic adolescent idiopathic scoliosis (AIS). Ascertain if increased metal density is required for larger or stiffer curves. Multicentre retrospective case series of patients with Lenke 1-2 AIS treated with single-stage posterior only surgery using a standardized surgical technique; constructs using >80 % screws with variable metal density. All cases had >2-year follow up. Outcomes measures included coronal and sagittal radiographic outcomes, metal density (number of instrumented pedicles vs total available), fusion length and cost. 106 cases included 94 female. 78 Lenke 1. Mean age 14 years (9–26). Mean main thoracic (MT) Cobb angle 63° corrected to 22° (66 %). No significant correlations were present between metal density and: (a) coronal curve correction rates of the MT (r = 0.13, p = 0.19); (b) lumbar curve frontal correction (r = −0.15, p = 0.12); (c) correction index in MT curve (r = −0.10, p = 0.32); and (d) correction index in lumbar curve (r = 0.11, p = 0.28). Metal density was not correlated with change in thoracic kyphosis (r = 0.22, p = 0.04) or lumbosacral lordosis (r = 0.27, p = 0.01). Longer fusions were associated with greater loss of thoracic kyphosis (r = −0.31, p = 0.003). Groups differing by preoperative curve size and stiffness had comparable corrections with similar metal density. The pedicle screw cost represented 21–29 % of overall cost of inpatient treatment depending on metal density. Metal density affects cost but not the coronal and sagittal correction of thoracic AIS. Neither larger nor stiffer curves necessitate high metal density.
- 1 December 2015
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 97 (12) , 1657-1661
Acromioclavicular joint reconstruction using the LockDown synthetic implant
Dislocation of the acromioclavicular joint is a relatively common injury and a number of surgical interventions have been described for its treatment. Recently, a synthetic ligament device has become available and been successfully used, however, like other non-native solutions, a compromise must be reached when choosing non-anatomical locations for their placement. This cadaveric study aimed to assess the effect of different clavicular anchorage points for the Lockdown device on the reduction of acromioclavicular joint dislocations, and suggest an optimal location. We also assessed whether further stability is provided using a coracoacromial ligament transfer (a modified Neviaser technique). The acromioclavicular joint was exposed on seven fresh-frozen cadaveric shoulders. The joint was reconstructed using the Lockdown implant using four different clavicular anchorage points and reduction was measured. The coracoacromial ligament was then transferred to the lateral end of the clavicle, and the joint re-assessed. If the Lockdown ligament was secured at the level of the conoid tubercle, the acromioclavicular joint could be reduced anatomically in all cases. If placed medial or 2 cm lateral, the joint was irreducible. If the Lockdown was placed 1 cm lateral to the conoid tubercle, the joint could be reduced with difficulty in four cases. Correct placement of the Lockdown device is crucial to allow anatomical joint reduction. Even when the Lockdown was placed over the conoid tubercle, anterior clavicle displacement remained but this could be controlled using a coracoacromial ligament transfer. Cite this article: Bone Joint J 2015;97-B:1657–61.
- 1 December 2015
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 97 (12) , 1657-1661
Acromioclavicular joint reconstruction using the LockDown synthetic implant
Dislocation of the acromioclavicular joint is a relatively common injury and a number of surgical interventions have been described for its treatment. Recently, a synthetic ligament device has become available and been successfully used, however, like other non-native solutions, a compromise must be reached when choosing non-anatomical locations for their placement. This cadaveric study aimed to assess the effect of different clavicular anchorage points for the Lockdown device on the reduction of acromioclavicular joint dislocations, and suggest an optimal location. We also assessed whether further stability is provided using a coracoacromial ligament transfer (a modified Neviaser technique). The acromioclavicular joint was exposed on seven fresh-frozen cadaveric shoulders. The joint was reconstructed using the Lockdown implant using four different clavicular anchorage points and reduction was measured. The coracoacromial ligament was then transferred to the lateral end of the clavicle, and the joint re-assessed. If the Lockdown ligament was secured at the level of the conoid tubercle, the acromioclavicular joint could be reduced anatomically in all cases. If placed medial or 2 cm lateral, the joint was irreducible. If the Lockdown was placed 1 cm lateral to the conoid tubercle, the joint could be reduced with difficulty in four cases. Correct placement of the Lockdown device is crucial to allow anatomical joint reduction. Even when the Lockdown was placed over the conoid tubercle, anterior clavicle displacement remained but this could be controlled using a coracoacromial ligament transfer. Cite this article: Bone Joint J 2015;97-B:1657–61.
- 1 April 2015
- Published by Wolters Kluwer Health in Journal of Spinal Disorders & Techniques
- Vol. 28 (3) , 80-88
Anterior or Posterior Surgery for Right Thoracic Adolescent Idiopathic Scoliosis (AIS)? A Prospective Cohorts’ Comparison Using Radiologic and Functional Outcomes
Prospective cohort study. Prospectively compare patient-reported as well as clinical and radiologic outcomes after anterior or posterior surgery for right thoracic adolescent idiopathic scoliosis (AIS) in a single center by the same surgeons. Anterior and posterior spinal instrumentation and arthrodesis are both well-established treatments of thoracic AIS. The majority of studies comparing the 2 approaches have focused on radiographic outcomes. There remains a paucity of prospectively gathered patient-reported outcomes comparing surgical approaches. Forty-two consecutive patients with right thoracic AIS were treated in a single center by one of 2 surgeons with either anterior (n=18) or posterior (n=24) approaches and followed up for over 2 years. Radiographic, clinical, and patient-reported outcomes of the Modified Scoliosis Research Society Outcome Instrument were gathered and analyzed by an independent surgeon. Patients reported significant improvements in all areas of the Modified Scoliosis Research Society Outcome Instrument, especially pain and self-image domains. There were no significant differences in the degree of improvement in any domains between the groups. Posterior and anterior surgery corrected rib hump by 53% and 61%, respectively (P=0.4). The Main thoracic curve Cobb angle was corrected from 69 to 26 degrees (62%) by posterior surgery and 61 to 23 degrees (64%) by anterior surgery (P=0.6). Posterior surgery significantly reduced kyphosis and lumbosacral lordosis. Anterior surgery had no overall affect of sagittal alignment but seemed able to correct those hypokyphotic preoperatively. Complications differed and were largely approach-related--intrathoracic in anterior and wound-related in posterior surgery. Patients with right thoracic AIS of differing curve types but otherwise similar preoperatively demonstrated that anterior and posterior surgery are largely equivalent. Patient-reported outcomes are improved similarly by either approach. Both offer excellent radiographic and trunk deformity correction. Differences in the effect of sagittal alignment, operative time, and complications should be considered when selecting approach.
- 1 April 2015
- Published by Wolters Kluwer Health in Journal of Spinal Disorders & Techniques
- Vol. 28 (3) , 80-88
Anterior or Posterior Surgery for Right Thoracic Adolescent Idiopathic Scoliosis (AIS)? A Prospective Cohorts’ Comparison Using Radiologic and Functional Outcomes
Prospective cohort study. Prospectively compare patient-reported as well as clinical and radiologic outcomes after anterior or posterior surgery for right thoracic adolescent idiopathic scoliosis (AIS) in a single center by the same surgeons. Anterior and posterior spinal instrumentation and arthrodesis are both well-established treatments of thoracic AIS. The majority of studies comparing the 2 approaches have focused on radiographic outcomes. There remains a paucity of prospectively gathered patient-reported outcomes comparing surgical approaches. Forty-two consecutive patients with right thoracic AIS were treated in a single center by one of 2 surgeons with either anterior (n=18) or posterior (n=24) approaches and followed up for over 2 years. Radiographic, clinical, and patient-reported outcomes of the Modified Scoliosis Research Society Outcome Instrument were gathered and analyzed by an independent surgeon. Patients reported significant improvements in all areas of the Modified Scoliosis Research Society Outcome Instrument, especially pain and self-image domains. There were no significant differences in the degree of improvement in any domains between the groups. Posterior and anterior surgery corrected rib hump by 53% and 61%, respectively (P=0.4). The Main thoracic curve Cobb angle was corrected from 69 to 26 degrees (62%) by posterior surgery and 61 to 23 degrees (64%) by anterior surgery (P=0.6). Posterior surgery significantly reduced kyphosis and lumbosacral lordosis. Anterior surgery had no overall affect of sagittal alignment but seemed able to correct those hypokyphotic preoperatively. Complications differed and were largely approach-related--intrathoracic in anterior and wound-related in posterior surgery. Patients with right thoracic AIS of differing curve types but otherwise similar preoperatively demonstrated that anterior and posterior surgery are largely equivalent. Patient-reported outcomes are improved similarly by either approach. Both offer excellent radiographic and trunk deformity correction. Differences in the effect of sagittal alignment, operative time, and complications should be considered when selecting approach.