Frits Andreas Rangel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Frits Andreas Rangel has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Anne Marie Kuijpers-Jagtman
Universitas Gadjah Mada
7 shared publications - Ewald Maria Bronkhorst
Department of Dentistry, Radboud Institute for Health Sciences, Radboud University Medical Center, 6500 HB Nijmegen, The Netherlands
7 shared publications Stefaan J. Bergé
Department of Oral and Craniomaxillofacial Surgery, Radboud University Medical Centre, Nijmegen, The Netherlands, and
7 shared publicationsJ.M. Plooij
5 shared publicationsS.J. Bergé
5 shared publicationsT.J.J. Maal
Department of Oral and Maxillofacial Surgery, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
3 shared publications
Latest Publications
- Open Access
- 18 January 2016
- Published by Oxford University Press (OUP) in European Journal of Orthodontics
- Vol. 38 (4) , 440-445
Does powdering of the dentition increase the accuracy of fusing 3D stereophotographs and digital dental casts
The shiny vestibular surfaces of teeth make it difficult to match digital dental casts to 3D stereophotogrammetric images of patient teeth. This study tested whether reducing this shininess by coating the teeth with titanium-oxide powder might improve the accuracy of the matching procedure. Twenty patients participated in the study. For each patient, 3D stereophotogrammetric images were taken without and with a powder coating. Separately, digital dental casts were created. Next, the digital dental casts were fused with the 3D stereophotogrammetric images of either non-powdered or powdered dentition. Distance maps were created to evaluate the inter-surface distance between the digital dental cast and the 3D images. The matching accuracy was compared for dentition with and without powdering. Of all recorded distances between corresponding points, 95% was smaller than 0.84mm for the powdered dentition and smaller than 0.90mm for the non-powdered dentition. Although powdered dentition showed significantly better matching than non-powdered dentition, the difference was less than 0.1mm. Intra-observer statistics showed that five out of 24 repetitions gave significantly different results, but only for dentition that was not powdered. The patients did not have any major malocclusions. Severe malocclusions might cause greater difficulty in matching the dentition without powder. Only one type of powder was used, but it effectively reduced shininess. Powdering the dentition had a small, but significant, positive effect on matching. However, this effect was of minor clinical importance. Therefore, we do not recommend powdering the dentition for 3D stereophotogrammetric images used for matching procedures.
- 18 January 2016
- Published by Oxford University Press (OUP) in European Journal of Orthodontics
- Vol. 38 (4) , 440-445
Open AccessDoes powdering of the dentition increase the accuracy of fusing 3D stereophotographs and digital dental casts
The shiny vestibular surfaces of teeth make it difficult to match digital dental casts to 3D stereophotogrammetric images of patient teeth. This study tested whether reducing this shininess by coating the teeth with titanium-oxide powder might improve the accuracy of the matching procedure. Twenty patients participated in the study. For each patient, 3D stereophotogrammetric images were taken without and with a powder coating. Separately, digital dental casts were created. Next, the digital dental casts were fused with the 3D stereophotogrammetric images of either non-powdered or powdered dentition. Distance maps were created to evaluate the inter-surface distance between the digital dental cast and the 3D images. The matching accuracy was compared for dentition with and without powdering. Of all recorded distances between corresponding points, 95% was smaller than 0.84mm for the powdered dentition and smaller than 0.90mm for the non-powdered dentition. Although powdered dentition showed significantly better matching than non-powdered dentition, the difference was less than 0.1mm. Intra-observer statistics showed that five out of 24 repetitions gave significantly different results, but only for dentition that was not powdered. The patients did not have any major malocclusions. Severe malocclusions might cause greater difficulty in matching the dentition without powder. Only one type of powder was used, but it effectively reduced shininess. Powdering the dentition had a small, but significant, positive effect on matching. However, this effect was of minor clinical importance. Therefore, we do not recommend powdering the dentition for 3D stereophotogrammetric images used for matching procedures.
- 1 September 2014
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 146 (3) , 328-336
Reproducibility and accuracy of linear measurements on dental models derived from cone-beam computed tomography compared with digital dental casts
- 1 September 2014
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 146 (3) , 328-336
Reproducibility and accuracy of linear measurements on dental models derived from cone-beam computed tomography compared with digital dental casts
- Open Access
- 20 March 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (3) , e59130
Accuracy and Reliability of a Novel Method for Fusion of Digital Dental Casts and Cone Beam Computed Tomography Scans
Several methods have been proposed to integrate digital models into Cone Beam Computed Tomography scans. Since all these methods have some drawbacks such as radiation exposure, soft tissue deformation and time-consuming digital handling processes, we propose a new method to integrate digital dental casts into Cone Beam Computed Tomography scans. Plaster casts of 10 patients were randomly selected and 5 titanium markers were glued to the upper and lower plaster cast. The plaster models were scanned, impressions were taken from the plaster models and the impressions were also scanned. Linear measurements were performed on all three models, to assess accuracy and reproducibility. Besides that, matching of the scanned plaster models and scanned impressions was done, to assess the accuracy of the matching procedure. Results show that all measurement errors are smaller than 0.2 mm, and that 81% is smaller than 0.1 mm. Matching of the scanned plaster casts and scanned impressions show a mean error between the two surfaces of the upper arch of 0.14 mm and for the lower arch of 0.18 mm. The time needed for reconstructing the CBCT scans to a digital patient, where the impressions are integrated into the CBCT scan of the patient takes about 15 minutes, with little variance between patients. In conclusion, we can state that this new method is a reliable method to integrate digital dental casts into CBCT scans. As far as radiation exposure, soft tissue deformation and digital handling processes are concerned, it is a significant improvement compared to the previously published methods.
- 20 March 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (3) , e59130
Open AccessAccuracy and Reliability of a Novel Method for Fusion of Digital Dental Casts and Cone Beam Computed Tomography Scans
Several methods have been proposed to integrate digital models into Cone Beam Computed Tomography scans. Since all these methods have some drawbacks such as radiation exposure, soft tissue deformation and time-consuming digital handling processes, we propose a new method to integrate digital dental casts into Cone Beam Computed Tomography scans. Plaster casts of 10 patients were randomly selected and 5 titanium markers were glued to the upper and lower plaster cast. The plaster models were scanned, impressions were taken from the plaster models and the impressions were also scanned. Linear measurements were performed on all three models, to assess accuracy and reproducibility. Besides that, matching of the scanned plaster models and scanned impressions was done, to assess the accuracy of the matching procedure. Results show that all measurement errors are smaller than 0.2 mm, and that 81% is smaller than 0.1 mm. Matching of the scanned plaster casts and scanned impressions show a mean error between the two surfaces of the upper arch of 0.14 mm and for the lower arch of 0.18 mm. The time needed for reconstructing the CBCT scans to a digital patient, where the impressions are integrated into the CBCT scan of the patient takes about 15 minutes, with little variance between patients. In conclusion, we can state that this new method is a reliable method to integrate digital dental casts into CBCT scans. As far as radiation exposure, soft tissue deformation and digital handling processes are concerned, it is a significant improvement compared to the previously published methods.
- Open Access
- 23 September 2012
- Published by Wiley in ISRN Dentistry
- Vol. 2012, 1-6
Integration of Digital Dental Casts in Cone-Beam Computed Tomography Scans
Cone-beam computed tomography (CBCT) is widely used in maxillofacial surgery. The CBCT image of the dental arches, however, is of insufficient quality to use in digital planning of orthognathic surgery. Several authors have described methods to integrate digital dental casts into CBCT scans, but all reported methods have drawbacks. The aim of this feasibility study is to present a new simplified method to integrate digital dental casts into CBCT scans. In a patient scheduled for orthognathic surgery, titanium markers were glued to the gingiva. Next, a CBCT scan and dental impressions were made. During the impression-taking procedure, the titanium markers were transferred to the impression. The impressions were scanned, and all CBCT datasets were exported in DICOM format. The two datasets were matched, and the dentition derived from the scanned impressions was transferred to the CBCT of the patient. After matching the two datasets, the average distance between the corresponding markers was 0.1 mm. This novel method allows for the integration of digital dental casts into CBCT scans, overcoming problems such as unwanted extra radiation exposure, distortion of soft tissues due to the use of bite jigs, and time-consuming digital data handling.
- 23 September 2012
- Published by Wiley in ISRN Dentistry
- Vol. 2012, 1-6
Open AccessIntegration of Digital Dental Casts in Cone-Beam Computed Tomography Scans
Cone-beam computed tomography (CBCT) is widely used in maxillofacial surgery. The CBCT image of the dental arches, however, is of insufficient quality to use in digital planning of orthognathic surgery. Several authors have described methods to integrate digital dental casts into CBCT scans, but all reported methods have drawbacks. The aim of this feasibility study is to present a new simplified method to integrate digital dental casts into CBCT scans. In a patient scheduled for orthognathic surgery, titanium markers were glued to the gingiva. Next, a CBCT scan and dental impressions were made. During the impression-taking procedure, the titanium markers were transferred to the impression. The impressions were scanned, and all CBCT datasets were exported in DICOM format. The two datasets were matched, and the dentition derived from the scanned impressions was transferred to the CBCT of the patient. After matching the two datasets, the average distance between the corresponding markers was 0.1 mm. This novel method allows for the integration of digital dental casts into CBCT scans, overcoming problems such as unwanted extra radiation exposure, distortion of soft tissues due to the use of bite jigs, and time-consuming digital data handling.
- 1 September 2012
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 142 (3) , 308-313
Dental models made with an intraoral scanner: A validation study
- 1 September 2012
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 142 (3) , 308-313
Dental models made with an intraoral scanner: A validation study
- 1 September 2012
- Published by Elsevier in International Journal of Oral and Maxillofacial Surgery
- Vol. 41 (9) , 1137-1145
One year postoperative hard and soft tissue volumetric changes after a BSSO mandibular advancement
- 1 September 2012
- Published by Elsevier in International Journal of Oral and Maxillofacial Surgery
- Vol. 41 (9) , 1137-1145
One year postoperative hard and soft tissue volumetric changes after a BSSO mandibular advancement
- 1 November 2011
- Published by Elsevier in International Journal of Oral and Maxillofacial Surgery
- Vol. 40 (11) , 1252-1257
Variation of the face in rest using 3D stereophotogrammetry
- 1 November 2011
- Published by Elsevier in International Journal of Oral and Maxillofacial Surgery
- Vol. 40 (11) , 1252-1257
Variation of the face in rest using 3D stereophotogrammetry
- 1 October 2010
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 68 (10) , 2391-2401
Registration of 3-Dimensional Facial Photographs for Clinical Use
- 1 October 2010
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 68 (10) , 2391-2401
Registration of 3-Dimensional Facial Photographs for Clinical Use
- 17 July 2010
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 15 (5) , 721-727
Measurements on 3D models of human skulls derived from two different cone beam CT scanners
The aims of this study were to compare measurements on three-dimensional (3D) models of human skulls derived from two different cone beam CT scanners (CBCT) and to evaluate if the used hardware can influence the performed measurements. CBCT scans of 40 dry human skulls with both the i-CAT™ and the Iluma™ cone beam CT scanners were made. From the CBCT scans, 3D models were constructed. One operator identified 19 landmarks five times on both types of 3D models with a time interval of 1 week. Intra-observer reliability was high for most measurements. There was a statistically significant and clinically relevant difference for some measurements between constructed 3D models of the same skull from the two different CBCT devices. Used hardware for scanning might influence the measurements performed. This means that care should be taken when interpreting measurements made on CBCT 3D models derived from different CBCT devices.
- 17 July 2010
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 15 (5) , 721-727
Measurements on 3D models of human skulls derived from two different cone beam CT scanners
The aims of this study were to compare measurements on three-dimensional (3D) models of human skulls derived from two different cone beam CT scanners (CBCT) and to evaluate if the used hardware can influence the performed measurements. CBCT scans of 40 dry human skulls with both the i-CAT™ and the Iluma™ cone beam CT scanners were made. From the CBCT scans, 3D models were constructed. One operator identified 19 landmarks five times on both types of 3D models with a time interval of 1 week. Intra-observer reliability was high for most measurements. There was a statistically significant and clinically relevant difference for some measurements between constructed 3D models of the same skull from the two different CBCT devices. Used hardware for scanning might influence the measurements performed. This means that care should be taken when interpreting measurements made on CBCT 3D models derived from different CBCT devices.
- 1 April 2010
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 68 (4) , 811-817
Reproducibility of 3 Different Tracing Methods Based on Cone Beam Computed Tomography in Determining the Anatomical Position of the Mandibular Canal
- 1 April 2010
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 68 (4) , 811-817
Reproducibility of 3 Different Tracing Methods Based on Cone Beam Computed Tomography in Determining the Anatomical Position of the Mandibular Canal