Jaka Katrašnik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jaka Katrašnik has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Boštjan Likar
University of Ljubljana, Faculty of Electrical Engineering, Trzaska cesta 25, Ljubljana SI-1000, Slovenia
9 shared publicationsFranjo Pernuš
University of Ljubljana, Faculty of Electrical Engineering, Trzaska cesta 25, Ljubljana SI-1000, Slovenia
9 shared publicationsMiran Bürmen
Faculty of Electrical Engineering, Laboratory of Imaging Technologies, University of Ljubljana, Tržaška 25, 1000 Ljubljana, Slovenia
4 shared publicationsBostjan Likar
1 shared publication- Boštjan Likar
Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia
1 shared publication Franjo Pernus
1 shared publication
Latest Publications
- 15 May 2013
- Published by Optica Publishing Group in Applied Optics
- Vol. 52 (15) , 3526-3537
Radiometric calibration and noise estimation of acousto-optic tunable filter hyperspectral imaging systems.
The accuracy of the radiometric response of acousto-optic tunable filter (AOTF) hyperspectral imaging systems is crucial for obtaining reliable measurements. It is therefore important to know the radiometric response and noise characteristics of the hyperspectral imaging system used. A radiometric model of an AOTF hyperspectral imaging system composed of an imaging sensor radiometric model (CCD, CMOS, and sCMOS) and an AOTF light transmission model is proposed. Using the radiometric model, a method for obtaining the fixed pattern noise (FPN) of the imaging system by displacing and imaging an illuminated reference target is developed. Methods for estimating the temporal noise of the imaging system, using the photon transfer method, and for correcting FPN are also presented. Noise estimation and image restoration methods were tested on an AOTF hyperspectral imaging system. The results indicate that the developed methods can accurately calculate temporal and FPN, and can effectively correct the acquired images. After correction, the signal-to-noise ratio of the acquired images was shown to increase by 26%.
- 15 May 2013
- Published by Optica Publishing Group in Applied Optics
- Vol. 52 (15) , 3526-3537
Radiometric calibration and noise estimation of acousto-optic tunable filter hyperspectral imaging systems.
The accuracy of the radiometric response of acousto-optic tunable filter (AOTF) hyperspectral imaging systems is crucial for obtaining reliable measurements. It is therefore important to know the radiometric response and noise characteristics of the hyperspectral imaging system used. A radiometric model of an AOTF hyperspectral imaging system composed of an imaging sensor radiometric model (CCD, CMOS, and sCMOS) and an AOTF light transmission model is proposed. Using the radiometric model, a method for obtaining the fixed pattern noise (FPN) of the imaging system by displacing and imaging an illuminated reference target is developed. Methods for estimating the temporal noise of the imaging system, using the photon transfer method, and for correcting FPN are also presented. Noise estimation and image restoration methods were tested on an AOTF hyperspectral imaging system. The results indicate that the developed methods can accurately calculate temporal and FPN, and can effectively correct the acquired images. After correction, the signal-to-noise ratio of the acquired images was shown to increase by 26%.
- 20 February 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (4) , 4841-4853
A method for characterizing illumination systems for hyperspectral imaging
Near-infrared hyperspectral imaging is becoming a popular tool in various fields. In all imaging systems, proper illumination is crucial for attaining optimal image quality that is needed for the best performance of image analysis algorithms. In hyperspectral imaging, the acquired spectral signature has to be representative in all parts of the imaged object. Therefore, the whole object must be equally well illuminated–without shadows or specular reflections. As there are no restrictions imposed on the material and geometry of the object, the desired illumination of the object can only be achieved with completely diffuse illumination. In order to minimize shadows and specular reflections, the light illuminating the object must be spatially, angularly and spectrally uniform. The quality of illumination systems for hyperspectral imaging can therefore be assessed using spatial-intensity, spatial-spectral, angular-intensity and angular-spectral non-uniformity measures that are presented in this paper. Emphasis is given to the angular-intensity and angular-spectral non-uniformity measures, which are the most important contributions of this paper. The measures were defined on images of two reference targets—a flat, white diffuse reflectance target and a sphere grid target—acquired with an acousto-optic tunable filter (AOTF) based hyperspectral imaging system. The proposed measures were tested on a ring light and on a diffuse dome illumination system.
- 20 February 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (4) , 4841-4853
A method for characterizing illumination systems for hyperspectral imaging
Near-infrared hyperspectral imaging is becoming a popular tool in various fields. In all imaging systems, proper illumination is crucial for attaining optimal image quality that is needed for the best performance of image analysis algorithms. In hyperspectral imaging, the acquired spectral signature has to be representative in all parts of the imaged object. Therefore, the whole object must be equally well illuminated–without shadows or specular reflections. As there are no restrictions imposed on the material and geometry of the object, the desired illumination of the object can only be achieved with completely diffuse illumination. In order to minimize shadows and specular reflections, the light illuminating the object must be spatially, angularly and spectrally uniform. The quality of illumination systems for hyperspectral imaging can therefore be assessed using spatial-intensity, spatial-spectral, angular-intensity and angular-spectral non-uniformity measures that are presented in this paper. Emphasis is given to the angular-intensity and angular-spectral non-uniformity measures, which are the most important contributions of this paper. The measures were defined on images of two reference targets—a flat, white diffuse reflectance target and a sphere grid target—acquired with an acousto-optic tunable filter (AOTF) based hyperspectral imaging system. The proposed measures were tested on a ring light and on a diffuse dome illumination system.
- 10 February 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7891, 78910T-78910T-10
Illumination system characterization for hyperspectral imaging
Near-infrared hyperspectral imaging is becoming a popular tool in the biomedical field, especially for detection and analysis of different types of cancers, analysis of skin burns and bruises, imaging of blood vessels and for many other applications. As in all imaging systems, proper illumination is crucial to attain optimal image quality that is needed for best performance of image analysis algorithms. In hyperspectral imaging based on filters (AOTF, LCTF and filter wheel) the acquired spectral signature has to be representative in all parts of the imaged object. Therefore, the whole object must be equally well illuminated - without shadows and specular reflections. As there are no restrictions imposed on the material and geometry of the object, the desired object illumination can only be achieved with completely diffuse illumination. In order to minimize shadows and specular reflections in diffuse illumination the light illuminating the object must be spatially, angularly and spectrally uniform. We present and test two diffuse illumination system designs that try to achieve optimal uniformity of the above mentioned properties. The illumination uniformity properties were measured with an AOTF based hyperspectral imaging system utilizing a standard white diffuse reflectance target and a specially designed calibration target for estimating the spatial and angular illumination uniformity.
- 10 February 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7891, 78910T-78910T-10
Illumination system characterization for hyperspectral imaging
Near-infrared hyperspectral imaging is becoming a popular tool in the biomedical field, especially for detection and analysis of different types of cancers, analysis of skin burns and bruises, imaging of blood vessels and for many other applications. As in all imaging systems, proper illumination is crucial to attain optimal image quality that is needed for best performance of image analysis algorithms. In hyperspectral imaging based on filters (AOTF, LCTF and filter wheel) the acquired spectral signature has to be representative in all parts of the imaged object. Therefore, the whole object must be equally well illuminated - without shadows and specular reflections. As there are no restrictions imposed on the material and geometry of the object, the desired object illumination can only be achieved with completely diffuse illumination. In order to minimize shadows and specular reflections in diffuse illumination the light illuminating the object must be spatially, angularly and spectrally uniform. We present and test two diffuse illumination system designs that try to achieve optimal uniformity of the above mentioned properties. The illumination uniformity properties were measured with an AOTF based hyperspectral imaging system utilizing a standard white diffuse reflectance target and a specially designed calibration target for estimating the spatial and angular illumination uniformity.
- 1 November 2010
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 64 (11) , 1265-1273
Deconvolution in Acousto-Optical Tunable Filter Spectrometry
Spectrometers and spectral imaging systems based on the acousto-optical tunable filter (AOTF) are becoming commonly used in many different fields in which high spectral resolution is crucial, e.g., laser-induced breakdown spectroscopy, Raman spectroscopy, and absorption spectroscopy of gases. As AOTFs have many advantages over other spectroscopic instruments but lack spectral resolution, a procedure for resolution enhancement, composed of point spread function characterization and spectrum preprocessing and deconvolution, is proposed. Wiener, Fourier-wavelet regularized (ForWaRD), Richardson–Lucy, and Wavelet–Lucy deconvolution methods were tested and their performances assessed with two deconvolution quality measures: resolution enhancement and noise amplification. It was shown that the proposed spectral resolution enhancement is feasible and gives good results for line spectra and highly dynamic spectra.
- 1 November 2010
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 64 (11) , 1265-1273
Deconvolution in Acousto-Optical Tunable Filter Spectrometry
Spectrometers and spectral imaging systems based on the acousto-optical tunable filter (AOTF) are becoming commonly used in many different fields in which high spectral resolution is crucial, e.g., laser-induced breakdown spectroscopy, Raman spectroscopy, and absorption spectroscopy of gases. As AOTFs have many advantages over other spectroscopic instruments but lack spectral resolution, a procedure for resolution enhancement, composed of point spread function characterization and spectrum preprocessing and deconvolution, is proposed. Wiener, Fourier-wavelet regularized (ForWaRD), Richardson–Lucy, and Wavelet–Lucy deconvolution methods were tested and their performances assessed with two deconvolution quality measures: resolution enhancement and noise amplification. It was shown that the proposed spectral resolution enhancement is feasible and gives good results for line spectra and highly dynamic spectra.
- 13 May 2010
- Published by Optica Publishing Group in Applied Optics
- Vol. 49 (15) , 2813-2818
Geometric calibration of a hyperspectral imaging system
Every imaging system requires a geometric calibration to yield accurate optical measurements. Geometric calibration typically involves imaging of a known calibration object and finding the parameters of a camera model and a model of optical aberrations. Optical aberrations can vary significantly across the wide spectral ranges of hyperspectral imaging systems, which can lead to inaccurate geometric calibrations if conventional methods were used. We propose a method based on a B-spline transformation field to align the spectral images of the calibration object to the model image of the calibration object. The degree of spatial alignment between the ideal and the spectral images is measured by normalized cross correlation. Geometric calibration was performed on a hyperspectral imaging system based on an acousto-optic tunable filter designed for the near-infrared spectral range (). The proposed method can accurately characterize wavelength dependent optical aberrations and produce transformations for efficient subpixel geometric calibration.- 13 May 2010
- Published by Optica Publishing Group in Applied Optics
- Vol. 49 (15) , 2813-2818
Geometric calibration of a hyperspectral imaging system
Every imaging system requires a geometric calibration to yield accurate optical measurements. Geometric calibration typically involves imaging of a known calibration object and finding the parameters of a camera model and a model of optical aberrations. Optical aberrations can vary significantly across the wide spectral ranges of hyperspectral imaging systems, which can lead to inaccurate geometric calibrations if conventional methods were used. We propose a method based on a B-spline transformation field to align the spectral images of the calibration object to the model image of the calibration object. The degree of spatial alignment between the ideal and the spectral images is measured by normalized cross correlation. Geometric calibration was performed on a hyperspectral imaging system based on an acousto-optic tunable filter designed for the near-infrared spectral range (). The proposed method can accurately characterize wavelength dependent optical aberrations and produce transformations for efficient subpixel geometric calibration.- 1 March 2010
- Published by Elsevier in Chemometrics and Intelligent Laboratory Systems
- Vol. 101 (1) , 23-29
Spectral characterization and calibration of AOTF spectrometers and hyper-spectral imaging systems
- 1 March 2010
- Published by Elsevier in Chemometrics and Intelligent Laboratory Systems
- Vol. 101 (1) , 23-29
Spectral characterization and calibration of AOTF spectrometers and hyper-spectral imaging systems
- 11 February 2010
- Published by SPIE-Intl Soc Optical Eng
- p. 75560I-75560I-6
Geometrical calibration of an AOTF hyper-spectral imaging system
Optical aberrations present an important problem in optical measurements. Geometrical calibration of an imaging system is therefore of the utmost importance for achieving accurate optical measurements. In hyper-spectral imaging systems, the problem of optical aberrations is even more pronounced because optical aberrations are wavelength dependent. Geometrical calibration must therefore be performed over the entire spectral range of the hyper-spectral imaging system, which is usually far greater than that of the visible light spectrum. This problem is especially adverse in AOTF (Acousto- Optic Tunable Filter) hyper-spectral imaging systems, as the diffraction of light in AOTF filters is dependent on both wavelength and angle of incidence. Geometrical calibration of hyper-spectral imaging system was performed by stable caliber of known dimensions, which was imaged at different wavelengths over the entire spectral range. The acquired images were then automatically registered to the caliber model by both parametric and nonparametric transformation based on B-splines and by minimizing normalized correlation coefficient. The calibration method was tested on an AOTF hyper-spectral imaging system in the near infrared spectral range. The results indicated substantial wavelength dependent optical aberration that is especially pronounced in the spectral range closer to the infrared part of the spectrum. The calibration method was able to accurately characterize the aberrations and produce transformations for efficient sub-pixel geometrical calibration over the entire spectral range, finally yielding better spatial resolution of hyperspectral imaging system.
- 11 February 2010
- Published by SPIE-Intl Soc Optical Eng
- p. 75560I-75560I-6
Geometrical calibration of an AOTF hyper-spectral imaging system
Optical aberrations present an important problem in optical measurements. Geometrical calibration of an imaging system is therefore of the utmost importance for achieving accurate optical measurements. In hyper-spectral imaging systems, the problem of optical aberrations is even more pronounced because optical aberrations are wavelength dependent. Geometrical calibration must therefore be performed over the entire spectral range of the hyper-spectral imaging system, which is usually far greater than that of the visible light spectrum. This problem is especially adverse in AOTF (Acousto- Optic Tunable Filter) hyper-spectral imaging systems, as the diffraction of light in AOTF filters is dependent on both wavelength and angle of incidence. Geometrical calibration of hyper-spectral imaging system was performed by stable caliber of known dimensions, which was imaged at different wavelengths over the entire spectral range. The acquired images were then automatically registered to the caliber model by both parametric and nonparametric transformation based on B-splines and by minimizing normalized correlation coefficient. The calibration method was tested on an AOTF hyper-spectral imaging system in the near infrared spectral range. The results indicated substantial wavelength dependent optical aberration that is especially pronounced in the spectral range closer to the infrared part of the spectrum. The calibration method was able to accurately characterize the aberrations and produce transformations for efficient sub-pixel geometrical calibration over the entire spectral range, finally yielding better spatial resolution of hyperspectral imaging system.
- 11 February 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7556, 75560H-75560H-10
Spectral characterization and calibration of AOTF spectrometers and hyper-spectral imaging system
The goal of this article is to present a novel method for spectral characterization and calibration of spectrometers and hyper-spectral imaging systems based on non-collinear acousto-optical tunable filters. The method characterizes the spectral tuning curve (frequency-wavelength characteristic) of the AOTF (Acousto-Optic Tunable Filter) filter by matching the acquired and modeled spectra of the HgAr calibration lamp, which emits line spectrum that can be well modeled via AOTF transfer function. In this way, not only tuning curve characterization and corresponding spectral calibration but also spectral resolution assessment is performed. The obtained results indicated that the proposed method is efficient, accurate and feasible for routine calibration of AOTF spectrometers and hyper-spectral imaging systems and thereby a highly competitive alternative to the existing calibration methods.
- 11 February 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7556, 75560H-75560H-10
Spectral characterization and calibration of AOTF spectrometers and hyper-spectral imaging system
The goal of this article is to present a novel method for spectral characterization and calibration of spectrometers and hyper-spectral imaging systems based on non-collinear acousto-optical tunable filters. The method characterizes the spectral tuning curve (frequency-wavelength characteristic) of the AOTF (Acousto-Optic Tunable Filter) filter by matching the acquired and modeled spectra of the HgAr calibration lamp, which emits line spectrum that can be well modeled via AOTF transfer function. In this way, not only tuning curve characterization and corresponding spectral calibration but also spectral resolution assessment is performed. The obtained results indicated that the proposed method is efficient, accurate and feasible for routine calibration of AOTF spectrometers and hyper-spectral imaging systems and thereby a highly competitive alternative to the existing calibration methods.
- Top Cited Papers
- 4 December 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 25 (1) , 485-493
A Survey of Mobile Robots for Distribution Power Line Inspection
The purpose of this paper is to present the most important achievements in the field of distribution power line inspection by mobile robots. Stimulated by the need for fast, accurate, safe and low-cost power line inspection, which would increase the quality of power delivery, the field of automated power line inspection has witnessed rapid development over the last decade. This paper addresses automated helicopter inspection, inspection with flying robots and inspection with climbing robots. The first attempts to automate power line inspection were conducted in the field of helicopter inspection. In recent years, however, the research was mostly focused on flying and climbing robots. These two types of robots for automated power line inspection are critically assessed according to four important characteristics: design requirements, inspection quality, autonomy and universality of inspection. Besides, some general not yet identified problems and tasks of inspection robots, which should be addressed in the future, are presented. In conclusion, the two robot types have specific benefits and drawbacks so that none can currently be considered generally advantageous.
- 4 December 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 25 (1) , 485-493
Top Cited PapersA Survey of Mobile Robots for Distribution Power Line Inspection
The purpose of this paper is to present the most important achievements in the field of distribution power line inspection by mobile robots. Stimulated by the need for fast, accurate, safe and low-cost power line inspection, which would increase the quality of power delivery, the field of automated power line inspection has witnessed rapid development over the last decade. This paper addresses automated helicopter inspection, inspection with flying robots and inspection with climbing robots. The first attempts to automate power line inspection were conducted in the field of helicopter inspection. In recent years, however, the research was mostly focused on flying and climbing robots. These two types of robots for automated power line inspection are critically assessed according to four important characteristics: design requirements, inspection quality, autonomy and universality of inspection. Besides, some general not yet identified problems and tasks of inspection robots, which should be addressed in the future, are presented. In conclusion, the two robot types have specific benefits and drawbacks so that none can currently be considered generally advantageous.
- 26 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7259, 725927
Contrast enhancement of subcutaneous blood vessel images by means of visible and near-infrared hyper-spectral imaging
Visualization of subcutaneous veins is very difficult with the naked eye, but important for diagnosis of medical conditions and different medical procedures such as catheter insertion and blood withdrawal. Moreover, recent studies showed that the images of subcutaneous veins could be used for biometric identification. The majority of methods used for enhancing the contrast between the subcutaneous veins and surrounding tissue are based on simple imaging systems utilizing CMOS or CCD cameras with LED illumination capable of acquiring images from the near infrared spectral region, usually near 900 nm. However, such simplified imaging methods cannot exploit the full potential of the spectral information. In this paper, a new highly versatile method for enhancing the contrast of subcutaneous veins based on state-of-the-art high-resolution hyper-spectral imaging system utilizing the spectral region from 550 to 1700 nm is presented. First, a detailed analysis of the contrast between the subcutaneous veins and the surrounding tissue as a function of wavelength, for several different positions on the human arm, was performed in order to extract the spectral regions with the highest contrast. The highest contrast images were acquired at 1100 nm, however, combining the individual images from the extracted spectral regions by the proposed contrast enhancement method resulted in a single image with up to ten-fold better contrast. Therefore, the proposed method has proved to be a useful tool for visualization of subcutaneous veins.© (2009) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
- 26 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7259, 725927
Contrast enhancement of subcutaneous blood vessel images by means of visible and near-infrared hyper-spectral imaging
Visualization of subcutaneous veins is very difficult with the naked eye, but important for diagnosis of medical conditions and different medical procedures such as catheter insertion and blood withdrawal. Moreover, recent studies showed that the images of subcutaneous veins could be used for biometric identification. The majority of methods used for enhancing the contrast between the subcutaneous veins and surrounding tissue are based on simple imaging systems utilizing CMOS or CCD cameras with LED illumination capable of acquiring images from the near infrared spectral region, usually near 900 nm. However, such simplified imaging methods cannot exploit the full potential of the spectral information. In this paper, a new highly versatile method for enhancing the contrast of subcutaneous veins based on state-of-the-art high-resolution hyper-spectral imaging system utilizing the spectral region from 550 to 1700 nm is presented. First, a detailed analysis of the contrast between the subcutaneous veins and the surrounding tissue as a function of wavelength, for several different positions on the human arm, was performed in order to extract the spectral regions with the highest contrast. The highest contrast images were acquired at 1100 nm, however, combining the individual images from the extracted spectral regions by the proposed contrast enhancement method resulted in a single image with up to ten-fold better contrast. Therefore, the proposed method has proved to be a useful tool for visualization of subcutaneous veins.© (2009) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.