Juliana Padilha Leitzke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Juliana Padilha Leitzke has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Hubert Zangl
Institute of Smart Systems Technologies, University of Klagenfurt, Klagenfurt am Worthersee, Austria
9 shared publications - Lisa-Marie Faller
Institute for Smart System Technologies, Sensors and Actuators Department, Alpen-Adria-Universität Klagenfurt, 9020 Klagenfurt, Austria
5 shared publications - Tobias Mitterer
Institute of Smart Systems Technologies, University of Klagenfurt, Klagenfurt am Worthersee, Austria
2 shared publications Astrid Della Mea
1 shared publication- Jean Carlos Cardozo da Silva
Universidade Tecnológica Federal do Paraná
1 shared publication - Jean Paulo Nakatu Longo
Multiphase Flow Research Center (NUEM), Universidade Tecnológica Federal do Paraná, Curitiba, Brazil
1 shared publication
Latest Publications
- Open Access
A Review on Electrical Impedance Tomography Spectroscopy
Electrical Impedance Tomography Spectroscopy (EITS) enables the reconstruction of material distributions inside an object based on the frequency-dependent characteristics of different substances. In this paper, we present a review of EITS focusing on physical principles of the technology, sensor geometries, existing measurement systems, reconstruction algorithms, and image representation methods. In addition, a novel imaging method is proposed which could fill some of the gaps found in the literature. As an example of an application, EITS of ice and water mixtures is used.
Open AccessA Review on Electrical Impedance Tomography Spectroscopy
Electrical Impedance Tomography Spectroscopy (EITS) enables the reconstruction of material distributions inside an object based on the frequency-dependent characteristics of different substances. In this paper, we present a review of EITS focusing on physical principles of the technology, sensor geometries, existing measurement systems, reconstruction algorithms, and image representation methods. In addition, a novel imaging method is proposed which could fill some of the gaps found in the literature. As an example of an application, EITS of ice and water mixtures is used.
- 1 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (3) , 941
Design and Evaluation of a Fast, High-Resolution Sensor Evaluation Platform Applied to MEMS Position Sensing (vol 67, pg 1014, 2018)
In [1], the Associate Editor was mistakenly listed to be the same as the corresponding author. The correct Associate Editor is Serge Demidenko.
- 1 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (3) , 941
Design and Evaluation of a Fast, High-Resolution Sensor Evaluation Platform Applied to MEMS Position Sensing (vol 67, pg 1014, 2018)
In [1], the Associate Editor was mistakenly listed to be the same as the corresponding author. The correct Associate Editor is Serge Demidenko.
- Open Access
Capacitive Sensing of Icing under Vacuum and Cryogenic Temperatures
In certain industrial processes, ice aggregations on surfaces can occur under almost vacuum conditions and at very low to cryogenic temperatures due to residual water molecules. This aggregation can affect the performance of the process and it is therefore of interest to monitor such surfaces. In this paper, we present a capacitive ice measurement system capable to operate in vacuum and temperatures of about and below. We present a capacitive sensor setup with a separation of sensor element and sensor electronics, such that the sensor electronics can reside outside the cold environment. It is demonstrated that the permittivity of such ice formations at vacuum and low temperatures is sufficient for measurement using the proposed sensor configuration. Results from a long-term study using a prototype further demonstrate the stability of the system and thus the feasibility of the proposed system for long term condition monitoring of surfaces in vacuum that are e.g., cooled by cryogenic liquids. The developed system uses wireless communication in order to allow for simple retrofitting of existing infrastructure even in remote locations.Open AccessCapacitive Sensing of Icing under Vacuum and Cryogenic Temperatures
In certain industrial processes, ice aggregations on surfaces can occur under almost vacuum conditions and at very low to cryogenic temperatures due to residual water molecules. This aggregation can affect the performance of the process and it is therefore of interest to monitor such surfaces. In this paper, we present a capacitive ice measurement system capable to operate in vacuum and temperatures of about and below. We present a capacitive sensor setup with a separation of sensor element and sensor electronics, such that the sensor electronics can reside outside the cold environment. It is demonstrated that the permittivity of such ice formations at vacuum and low temperatures is sufficient for measurement using the proposed sensor configuration. Results from a long-term study using a prototype further demonstrate the stability of the system and thus the feasibility of the proposed system for long term condition monitoring of surfaces in vacuum that are e.g., cooled by cryogenic liquids. The developed system uses wireless communication in order to allow for simple retrofitting of existing infrastructure even in remote locations. - Open Access
- 26 July 2019
- Published by Emerald Publishing in COMPEL - The international journal for computation and mathematics in electrical and electronic engineering
- Vol. 38 (5) , 1480-1492
Low-power electrical impedance tomography spectroscopy
Purpose: This paper aims to present an approach based on electrical impedance tomography spectroscopy (EITS) for the determination of water and ice fraction in low-power applications such as autarkic wireless sensors, which require a low computational complexity reconstruction approach and a low number of electrodes. This paper also investigates how the electrode design can affect the reconstruction results in tomography. Design/methodology/approach: EITS is performed by using a non-iterative method called optimal first order approximation. In addition to that, a planar electrode geometry is used instead of the traditional circular electrode geometry. Such a structure allows the system to identify materials placed on the region above the sensor, which do not need to be confined in a pipe. For the optimization, the mean squared error (MSE) between the reference images and the obtained reconstructed images was calculated. Findings: The authors demonstrate that even with a low number of four electrodes and a low complexity reconstruction algorithm, a reasonable reconstruction of water and ice fractions is possible. Furthermore, it is shown that an optimal distribution of the sensor electrodes can help to reduce the MSE without any costs in terms of computational complexity or power consumption. Originality/value: This paper shows through simulations that the reconstruction of ice and water mixtures is possible and that the electrode design is a topic of great importance, as they can significantly affect the reconstruction results.
- 26 July 2019
- Published by Emerald Publishing in COMPEL - The international journal for computation and mathematics in electrical and electronic engineering
- Vol. 38 (5) , 1480-1492
Open AccessLow-power electrical impedance tomography spectroscopy
Purpose: This paper aims to present an approach based on electrical impedance tomography spectroscopy (EITS) for the determination of water and ice fraction in low-power applications such as autarkic wireless sensors, which require a low computational complexity reconstruction approach and a low number of electrodes. This paper also investigates how the electrode design can affect the reconstruction results in tomography. Design/methodology/approach: EITS is performed by using a non-iterative method called optimal first order approximation. In addition to that, a planar electrode geometry is used instead of the traditional circular electrode geometry. Such a structure allows the system to identify materials placed on the region above the sensor, which do not need to be confined in a pipe. For the optimization, the mean squared error (MSE) between the reference images and the obtained reconstructed images was calculated. Findings: The authors demonstrate that even with a low number of four electrodes and a low complexity reconstruction algorithm, a reasonable reconstruction of water and ice fractions is possible. Furthermore, it is shown that an optimal distribution of the sensor electrodes can help to reduce the MSE without any costs in terms of computational complexity or power consumption. Originality/value: This paper shows through simulations that the reconstruction of ice and water mixtures is possible and that the electrode design is a topic of great importance, as they can significantly affect the reconstruction results.
- Open Access
- 1 August 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1065 (5) , 052010
Electrical Impedance Tomography Spectroscopy for Ice and Water Mixtures
The power that is necessary for heating wings and other aircraft surfaces in order to avoid ice formation is high. In this paper, the idea of a system is presented that could be used in the future for increasing safety and efficiency during flight by determining how the ice is being formed. Electrical Impedance Tomography Spectroscopy (EITS) is used to map water and ice mixtures formed on electrodes using Finite Element Method (FEM) simulations.
- 1 August 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1065 (5) , 052010
Open AccessElectrical Impedance Tomography Spectroscopy for Ice and Water Mixtures
The power that is necessary for heating wings and other aircraft surfaces in order to avoid ice formation is high. In this paper, the idea of a system is presented that could be used in the future for increasing safety and efficiency during flight by determining how the ice is being formed. Electrical Impedance Tomography Spectroscopy (EITS) is used to map water and ice mixtures formed on electrodes using Finite Element Method (FEM) simulations.
- 1 July 2018
- Published by Elsevier in Measurement
- Vol. 122, 459-465
Wireless differential pressure measurement for aircraft
- 1 July 2018
- Published by Elsevier in Measurement
- Vol. 122, 459-465
Wireless differential pressure measurement for aircraft
- 21 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 67 (5) , 1014-1027
Design and Evaluation of a Fast, High-Resolution Sensor Evaluation Platform Applied to MEMS Position Sensing
We present the design and implementation of an adaptable field-programmable gate array (FPGA)-based sensor evaluation platform. This platform is developed to benchmark a capacitive position sensor for a resonant micromirror system. The sensor is developed in a smart packaging solution as a multilayer inkjet-printed electrode structure on a 3-D-printed metal housing. Very high required resolutions of res pos < 50 nm, together with a wide measurement range of rm = 1000 μm at an offset of d₀ =1000 μm, motivate the development of such a platform. Yet, it is fully adaptable to other sensing principles (e.g., inductive). The suggested platform provides high sampling rates (up to ≈10 ns) and enables generation of trigger signals, i.e., the mirror control signal, without time lag (as could result from high-order filters). The online configurable FPGA block structure in combination with host software blocks enables flexible and individual design. The sensor read-out circuitry is designed as a carrier frequency system. Such a carrier frequency system enables flexible choices of bandwidth and measurement signal frequency. It thus allows for separation in frequency from coupling parasitics, i.e., other frequencies present in the device under test (e.g., actuation frequency in case of the micromirror system).
- 21 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 67 (5) , 1014-1027
Design and Evaluation of a Fast, High-Resolution Sensor Evaluation Platform Applied to MEMS Position Sensing
We present the design and implementation of an adaptable field-programmable gate array (FPGA)-based sensor evaluation platform. This platform is developed to benchmark a capacitive position sensor for a resonant micromirror system. The sensor is developed in a smart packaging solution as a multilayer inkjet-printed electrode structure on a 3-D-printed metal housing. Very high required resolutions of res pos < 50 nm, together with a wide measurement range of rm = 1000 μm at an offset of d₀ =1000 μm, motivate the development of such a platform. Yet, it is fully adaptable to other sensing principles (e.g., inductive). The suggested platform provides high sampling rates (up to ≈10 ns) and enables generation of trigger signals, i.e., the mirror control signal, without time lag (as could result from high-order filters). The online configurable FPGA block structure in combination with host software blocks enables flexible and individual design. The sensor read-out circuitry is designed as a carrier frequency system. Such a carrier frequency system enables flexible choices of bandwidth and measurement signal frequency. It thus allows for separation in frequency from coupling parasitics, i.e., other frequencies present in the device under test (e.g., actuation frequency in case of the micromirror system).
- 4 September 2017
- Published by Emerald Publishing in COMPEL - The international journal for computation and mathematics in electrical and electronic engineering
- Vol. 36 (5) , 1411-1420
Non-iterative object detection methods in electrical tomography for robotic applications
Purpose: This paper aims to investigate the usability of the non-iterative monotonicity approach for electrical capacitance tomography (ECT)-based object detection. This is of particular importance with respect to object detection in robotic applications. Design/methodology/approach: With respect to the detection problem, the authors propose a precomputed threshold value for the exclusion test to speed up the algorithm. Furthermore, they show that the use of an inhomogeneous split-up strategy of the region of interest (ROI) improves the performance of the object detection. Findings: The proposed split-up strategy enables to use the monotonicity approach for robotic applications, where the spatial placement of the electrodes is constrained to a planar geometry. Additionally, owing to the improvements in the exclusion tests, the selection of subregions in the ROI allows for avoiding self-detection. Furthermore, the computational costs of the algorithm are reduced owing to the use of a predefined threshold, while the detection capabilities are not significantly influenced. Originality/value: The presented simulation results show that the adapted split-up strategies for the ROI improve significantly the detection performance in comparison to the traditional ROI split-up strategy. Thus, the monotonicity approach becomes applicable for ECT-based object detection for applications, where only a reduced number of electrodes with constrained spatial placement can be used, such as in robotics.
- 4 September 2017
- Published by Emerald Publishing in COMPEL - The international journal for computation and mathematics in electrical and electronic engineering
- Vol. 36 (5) , 1411-1420
Non-iterative object detection methods in electrical tomography for robotic applications
Purpose: This paper aims to investigate the usability of the non-iterative monotonicity approach for electrical capacitance tomography (ECT)-based object detection. This is of particular importance with respect to object detection in robotic applications. Design/methodology/approach: With respect to the detection problem, the authors propose a precomputed threshold value for the exclusion test to speed up the algorithm. Furthermore, they show that the use of an inhomogeneous split-up strategy of the region of interest (ROI) improves the performance of the object detection. Findings: The proposed split-up strategy enables to use the monotonicity approach for robotic applications, where the spatial placement of the electrodes is constrained to a planar geometry. Additionally, owing to the improvements in the exclusion tests, the selection of subregions in the ROI allows for avoiding self-detection. Furthermore, the computational costs of the algorithm are reduced owing to the use of a predefined threshold, while the detection capabilities are not significantly influenced. Originality/value: The presented simulation results show that the adapted split-up strategies for the ROI improve significantly the detection performance in comparison to the traditional ROI split-up strategy. Thus, the monotonicity approach becomes applicable for ECT-based object detection for applications, where only a reduced number of electrodes with constrained spatial placement can be used, such as in robotics.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Design of a fast, high-resolution sensor evaluation platform applied to a capacitive position sensor for a micromirror
We present the design and implementation of an adaptable FPGA-based sensor evaluation platform. This platform is developed for benchmarking of an inkjet-printed capacitive position sensor for a resonant micromirror system as part of a smart packaging solution. In the target system, very high required resolutions of resolutions of res pos <; 50 nm 50 nm together with a wide measurement range of r m = 1000 pm at an offset of d 0 = 1000 pm motivate the development of such a platform. Still, it is fully adaptable to other sensing principles (e.g. inductive). The suggested platform provides for high sampling rates (up to ≈ 10 ns) and enables generation of trigger signals, i.e. the mirror control signal, without time lag (as could result from high order filters). The online configurable FPGA block structure in combination with host software blocks enables flexible and individual design. The sensor read-out circuitry is designed as carrier frequency system. Such a carrier frequency system enables flexible choices of bandwidth and measurement signal frequency. It thus allows for separation in frequency from coupling parasitics, i.e. other frequencies present in the device under test (e.g. actuation frequency in case of the micromirror system).
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Design of a fast, high-resolution sensor evaluation platform applied to a capacitive position sensor for a micromirror
We present the design and implementation of an adaptable FPGA-based sensor evaluation platform. This platform is developed for benchmarking of an inkjet-printed capacitive position sensor for a resonant micromirror system as part of a smart packaging solution. In the target system, very high required resolutions of resolutions of res pos <; 50 nm 50 nm together with a wide measurement range of r m = 1000 pm at an offset of d 0 = 1000 pm motivate the development of such a platform. Still, it is fully adaptable to other sensing principles (e.g. inductive). The suggested platform provides for high sampling rates (up to ≈ 10 ns) and enables generation of trigger signals, i.e. the mirror control signal, without time lag (as could result from high order filters). The online configurable FPGA block structure in combination with host software blocks enables flexible and individual design. The sensor read-out circuitry is designed as carrier frequency system. Such a carrier frequency system enables flexible choices of bandwidth and measurement signal frequency. It thus allows for separation in frequency from coupling parasitics, i.e. other frequencies present in the device under test (e.g. actuation frequency in case of the micromirror system).
- 20 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 77-80
Simple measuring system for impedance spectroscopy analysis of fluids
The use of impedance spectroscopy makes it possible to identify different substances based on their different fingerprint. In industrial applications, impedance spectroscopy has the potential to monitor processes. It is a technique of simple implementation, low cost and minimally invasive. In this study, a system based on electrical impedance spectroscopy was developed, calibrated and validated. The system comprises a sensing cell, an electronics and data processing algorithms for data extraction. The system was implemented and evaluated by measuring known substances, showing promising first results. As an example of application, the ice formation process under controlled conditions was monitored. The results show the capability of the developed system to monitor processes via impedance spectroscopy.
- 20 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 77-80
Simple measuring system for impedance spectroscopy analysis of fluids
The use of impedance spectroscopy makes it possible to identify different substances based on their different fingerprint. In industrial applications, impedance spectroscopy has the potential to monitor processes. It is a technique of simple implementation, low cost and minimally invasive. In this study, a system based on electrical impedance spectroscopy was developed, calibrated and validated. The system comprises a sensing cell, an electronics and data processing algorithms for data extraction. The system was implemented and evaluated by measuring known substances, showing promising first results. As an example of application, the ice formation process under controlled conditions was monitored. The results show the capability of the developed system to monitor processes via impedance spectroscopy.