Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Juliana Padilha Leitzke has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Review on Electrical Impedance Tomography Spectroscopy

    by Juliana Padilha Leitzke, Hubert Zangl

    Electrical Impedance Tomography Spectroscopy (EITS) enables the reconstruction of material distributions inside an object based on the frequency-dependent characteristics of different substances. In this paper, we present a review of EITS focusing on physical principles of the technology, sensor geometries, existing measurement systems, reconstruction algorithms, and image representation methods. In addition, a novel imaging method is proposed which could fill some of the gaps found in the literature. As an example of an application, EITS of ice and water mixtures is used.


  • Design and Evaluation of a Fast, High-Resolution Sensor Evaluation Platform Applied to MEMS Position Sensing (vol 67, pg 1014, 2018)

    by Lisa-Marie Faller, Tobias Mitterer, Juliana Padilha Leitzke, Hubert Zangl

    In [1], the Associate Editor was mistakenly listed to be the same as the corresponding author. The correct Associate Editor is Serge Demidenko.

  • Open Access

    Capacitive Sensing of Icing under Vacuum and Cryogenic Temperatures

    by Juliana Padilha Leitzke, Tobias Mitterer, Hubert Zangl

    In certain industrial processes, ice aggregations on surfaces can occur under almost vacuum conditions and at very low to cryogenic temperatures due to residual water molecules. This aggregation can affect the performance of the process and it is therefore of interest to monitor such surfaces. In this paper, we present a capacitive ice measurement system capable to operate in vacuum and temperatures of about - 120 ∘ C and below. We present a capacitive sensor setup with a separation of sensor element and sensor electronics, such that the sensor electronics can reside outside the cold environment. It is demonstrated that the permittivity of such ice formations at vacuum and low temperatures is sufficient for measurement using the proposed sensor configuration. Results from a long-term study using a prototype further demonstrate the stability of the system and thus the feasibility of the proposed system for long term condition monitoring of surfaces in vacuum that are e.g., cooled by cryogenic liquids. The developed system uses wireless communication in order to allow for simple retrofitting of existing infrastructure even in remote locations.


  • Open Access

    Low-power electrical impedance tomography spectroscopy

    by Juliana Padilha Leitzke, Hubert Zangl

    Purpose: This paper aims to present an approach based on electrical impedance tomography spectroscopy (EITS) for the determination of water and ice fraction in low-power applications such as autarkic wireless sensors, which require a low computational complexity reconstruction approach and a low number of electrodes. This paper also investigates how the electrode design can affect the reconstruction results in tomography. Design/methodology/approach: EITS is performed by using a non-iterative method called optimal first order approximation. In addition to that, a planar electrode geometry is used instead of the traditional circular electrode geometry. Such a structure allows the system to identify materials placed on the region above the sensor, which do not need to be confined in a pipe. For the optimization, the mean squared error (MSE) between the reference images and the obtained reconstructed images was calculated. Findings: The authors demonstrate that even with a low number of four electrodes and a low complexity reconstruction algorithm, a reasonable reconstruction of water and ice fractions is possible. Furthermore, it is shown that an optimal distribution of the sensor electrodes can help to reduce the MSE without any costs in terms of computational complexity or power consumption. Originality/value: This paper shows through simulations that the reconstruction of ice and water mixtures is possible and that the electrode design is a topic of great importance, as they can significantly affect the reconstruction results.


  • Open Access

    Electrical Impedance Tomography Spectroscopy for Ice and Water Mixtures

    by Juliana P. Leitzke, Hubert Zangl

    The power that is necessary for heating wings and other aircraft surfaces in order to avoid ice formation is high. In this paper, the idea of a system is presented that could be used in the future for increasing safety and efficiency during flight by determining how the ice is being formed. Electrical Impedance Tomography Spectroscopy (EITS) is used to map water and ice mixtures formed on electrodes using Finite Element Method (FEM) simulations.


  • Wireless differential pressure measurement for aircraft

    by Juliana P. Leitzke, Astrid Della Mea, Lisa-Marie Faller, Stephan Mühlbacher-Karrer, Hubert Zangl


  • Design and Evaluation of a Fast, High-Resolution Sensor Evaluation Platform Applied to MEMS Position Sensing

    by Lisa-Marie Faller, Tobias Mitterer, Juliana Padilha Leitzke, Hubert Zangl

    We present the design and implementation of an adaptable field-programmable gate array (FPGA)-based sensor evaluation platform. This platform is developed to benchmark a capacitive position sensor for a resonant micromirror system. The sensor is developed in a smart packaging solution as a multilayer inkjet-printed electrode structure on a 3-D-printed metal housing. Very high required resolutions of res pos < 50 nm, together with a wide measurement range of rm = 1000 μm at an offset of d₀ =1000 μm, motivate the development of such a platform. Yet, it is fully adaptable to other sensing principles (e.g., inductive). The suggested platform provides high sampling rates (up to ≈10 ns) and enables generation of trigger signals, i.e., the mirror control signal, without time lag (as could result from high-order filters). The online configurable FPGA block structure in combination with host software blocks enables flexible and individual design. The sensor read-out circuitry is designed as a carrier frequency system. Such a carrier frequency system enables flexible choices of bandwidth and measurement signal frequency. It thus allows for separation in frequency from coupling parasitics, i.e., other frequencies present in the device under test (e.g., actuation frequency in case of the micromirror system).


  • Non-iterative object detection methods in electrical tomography for robotic applications

    by Stephan Mühlbacher-Karrer, Juliana Padilha Leitzke, Lisa-Marie Faller, Hubert Zangl

    Purpose: This paper aims to investigate the usability of the non-iterative monotonicity approach for electrical capacitance tomography (ECT)-based object detection. This is of particular importance with respect to object detection in robotic applications. Design/methodology/approach: With respect to the detection problem, the authors propose a precomputed threshold value for the exclusion test to speed up the algorithm. Furthermore, they show that the use of an inhomogeneous split-up strategy of the region of interest (ROI) improves the performance of the object detection. Findings: The proposed split-up strategy enables to use the monotonicity approach for robotic applications, where the spatial placement of the electrodes is constrained to a planar geometry. Additionally, owing to the improvements in the exclusion tests, the selection of subregions in the ROI allows for avoiding self-detection. Furthermore, the computational costs of the algorithm are reduced owing to the use of a predefined threshold, while the detection capabilities are not significantly influenced. Originality/value: The presented simulation results show that the adapted split-up strategies for the ROI improve significantly the detection performance in comparison to the traditional ROI split-up strategy. Thus, the monotonicity approach becomes applicable for ECT-based object detection for applications, where only a reduced number of electrodes with constrained spatial placement can be used, such as in robotics.


  • Design of a fast, high-resolution sensor evaluation platform applied to a capacitive position sensor for a micromirror

    by Lisa-Marie Faller, Juliana Leitzke, Hubert Zangl

    We present the design and implementation of an adaptable FPGA-based sensor evaluation platform. This platform is developed for benchmarking of an inkjet-printed capacitive position sensor for a resonant micromirror system as part of a smart packaging solution. In the target system, very high required resolutions of resolutions of res pos <; 50 nm 50 nm together with a wide measurement range of r m = 1000 pm at an offset of d 0 = 1000 pm motivate the development of such a platform. Still, it is fully adaptable to other sensing principles (e.g. inductive). The suggested platform provides for high sampling rates (up to ≈ 10 ns) and enables generation of trigger signals, i.e. the mirror control signal, without time lag (as could result from high order filters). The online configurable FPGA block structure in combination with host software blocks enables flexible and individual design. The sensor read-out circuitry is designed as carrier frequency system. Such a carrier frequency system enables flexible choices of bandwidth and measurement signal frequency. It thus allows for separation in frequency from coupling parasitics, i.e. other frequencies present in the device under test (e.g. actuation frequency in case of the micromirror system).


  • Simple measuring system for impedance spectroscopy analysis of fluids

    by Jean Paulo Nakatu Longo, Juliana Padilha Leitzke, Rigoberto E.M. Morales, Marco Jose da Silva

    The use of impedance spectroscopy makes it possible to identify different substances based on their different fingerprint. In industrial applications, impedance spectroscopy has the potential to monitor processes. It is a technique of simple implementation, low cost and minimally invasive. In this study, a system based on electrical impedance spectroscopy was developed, calibrated and validated. The system comprises a sensing cell, an electronics and data processing algorithms for data extraction. The system was implemented and evaluated by measuring known substances, showing promising first results. As an example of application, the ice formation process under controlled conditions was monitored. The results show the capability of the developed system to monitor processes via impedance spectroscopy.