Adam Heller
Research Subjects
Adam Heller has a total of 127 co-authors. Here are the top co-authors by number of shared publications:
- Charles Buddie Mullins
Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712-1224, USA
23 shared publications - Dong-Liang Peng
State Key Laboratory of Physical Chemistry of Solid Surfaces Fujian Key Laboratory of Surface and Interface Engineering for High Performance Materials College of Materials Xiamen University Xiamen P. R. China
7 shared publications - Jason Alexander Weeks
University of Texas at Austin
7 shared publications - Jie Lin
State Key Laboratory of Physical Chemistry of Solid Surface, Fujian Key Laboratory of Surface and Interface Engineering for High Performance Materials, College of Materials, Xiamen University, Xiamen 361005, China
7 shared publications Melissa L. Meyerson
Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
5 shared publications- Qingshui Xie
State Key Lab of Physical Chemistry of Solid Surface, Fujian Key Laboratory of Materials Genome, Collaborative Innovation Center of Chemistry for Energy Materials, College of Materials, Xiamen University, Xiamen 361005, China
5 shared publications
Latest Publications
- Open Access
- 1 July 2025
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 27 (3_suppl)
Evolution of the Artificial Pancreas: Components and Integration—CGMs, Insulin, and AP Systems
The landmark Diabetes Control and Complications Trial (DCCT) showed that glucose control is critical to reducing the risk of diabetes-related complications. This chapter outlines a series of innovations and investigations that followed the DCCT, aimed at minimizing the risk of hypoglycemia while further improving glucose control. The chapter presents an example of innovations in wired enzyme technology that facilitated the movement from capillary glucose monitoring to continuous glucose monitoring (CGM) and ultimately, the first-factory calibrated CGM system. The next glycemic management innovation was to connect CGM data to an insulin pump containing an algorithm able to adjust insulin delivery based on the changing glucose levels and trends. The key features of automated insulin delivery (AID) systems, currently approved in the United States, are presented. The AID summary table includes type of pump, type and function of the insulin delivery algorithm, the data management system, and the indications for use. The next section explores the innovation of alternative routes of insulin delivery to move toward the goal of a fully automated insulin delivery system. The main trials in developing and implementing an implantable intraperitoneal programmable system are summarized. The last section explores if sensor input in addition to glucose levels such as continuous sensing of ketone, lactate, or insulin levels may provide valuable feedback to move us closer to a fully autonomous AID system. Much of this diabetes innovation and investigation work has been supported by the National Institute of Diabetes and Digestive and Kidney Diseases over that last 75 years.
- 1 July 2025
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 27 (3_suppl)
Open AccessEvolution of the Artificial Pancreas: Components and Integration—CGMs, Insulin, and AP Systems
The landmark Diabetes Control and Complications Trial (DCCT) showed that glucose control is critical to reducing the risk of diabetes-related complications. This chapter outlines a series of innovations and investigations that followed the DCCT, aimed at minimizing the risk of hypoglycemia while further improving glucose control. The chapter presents an example of innovations in wired enzyme technology that facilitated the movement from capillary glucose monitoring to continuous glucose monitoring (CGM) and ultimately, the first-factory calibrated CGM system. The next glycemic management innovation was to connect CGM data to an insulin pump containing an algorithm able to adjust insulin delivery based on the changing glucose levels and trends. The key features of automated insulin delivery (AID) systems, currently approved in the United States, are presented. The AID summary table includes type of pump, type and function of the insulin delivery algorithm, the data management system, and the indications for use. The next section explores the innovation of alternative routes of insulin delivery to move toward the goal of a fully automated insulin delivery system. The main trials in developing and implementing an implantable intraperitoneal programmable system are summarized. The last section explores if sensor input in addition to glucose levels such as continuous sensing of ketone, lactate, or insulin levels may provide valuable feedback to move us closer to a fully autonomous AID system. Much of this diabetes innovation and investigation work has been supported by the National Institute of Diabetes and Digestive and Kidney Diseases over that last 75 years.
- Open Access
- 1 July 2025
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 19 (4) , 883-894
Evolution of the Artificial Pancreas: Components and Integration—CGMs, Insulin, and AP Systems
The landmark Diabetes Control and Complications Trial (DCCT) showed that glucose control is critical to reducing the risk of diabetes-related complications. This chapter outlines a series of innovations and investigations that followed the DCCT, aimed at minimizing the risk of hypoglycemia while further improving glucose control. The chapter presents an example of innovations in wired enzyme technology that facilitated the movement from capillary glucose monitoring to continuous glucose monitoring (CGM) and ultimately, the first-factory calibrated CGM system. The next glycemic management innovation was to connect CGM data to an insulin pump containing an algorithm able to adjust insulin delivery based on the changing glucose levels and trends. The key features of automated insulin delivery (AID) systems, currently approved in the United States, are presented. The AID summary table includes type of pump, type and function of the insulin delivery algorithm, the data management system, and the indications for use. The next section explores the innovation of alternative routes of insulin delivery to move toward the goal of a fully automated insulin delivery system. The main trials in developing and implementing an implantable intraperitoneal programmable system are summarized. The last section explores if sensor input in addition to glucose levels such as continuous sensing of ketone, lactate, or insulin levels may provide valuable feedback to move us closer to a fully autonomous AID system. Much of this diabetes innovation and investigation work has been supported by the National Institute of Diabetes and Digestive and Kidney Diseases over that last 75 years.
- 1 July 2025
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 19 (4) , 883-894
Open AccessEvolution of the Artificial Pancreas: Components and Integration—CGMs, Insulin, and AP Systems
The landmark Diabetes Control and Complications Trial (DCCT) showed that glucose control is critical to reducing the risk of diabetes-related complications. This chapter outlines a series of innovations and investigations that followed the DCCT, aimed at minimizing the risk of hypoglycemia while further improving glucose control. The chapter presents an example of innovations in wired enzyme technology that facilitated the movement from capillary glucose monitoring to continuous glucose monitoring (CGM) and ultimately, the first-factory calibrated CGM system. The next glycemic management innovation was to connect CGM data to an insulin pump containing an algorithm able to adjust insulin delivery based on the changing glucose levels and trends. The key features of automated insulin delivery (AID) systems, currently approved in the United States, are presented. The AID summary table includes type of pump, type and function of the insulin delivery algorithm, the data management system, and the indications for use. The next section explores the innovation of alternative routes of insulin delivery to move toward the goal of a fully automated insulin delivery system. The main trials in developing and implementing an implantable intraperitoneal programmable system are summarized. The last section explores if sensor input in addition to glucose levels such as continuous sensing of ketone, lactate, or insulin levels may provide valuable feedback to move us closer to a fully autonomous AID system. Much of this diabetes innovation and investigation work has been supported by the National Institute of Diabetes and Digestive and Kidney Diseases over that last 75 years.
- 28 February 2023
- Published by Wiley in Angewandte Chemie
- Vol. 135 (11)
Frontispiz: Stainless Steel‐Like Passivation Inspires Persistent Silicon Anodes for Lithium‐Ion Batteries
- 28 February 2023
- Published by Wiley in Angewandte Chemie
- Vol. 135 (11)
Frontispiz: Stainless Steel‐Like Passivation Inspires Persistent Silicon Anodes for Lithium‐Ion Batteries
- 28 February 2023
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 62 (11)
Frontispiece: Stainless Steel‐Like Passivation Inspires Persistent Silicon Anodes for Lithium‐Ion Batteries
- 28 February 2023
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 62 (11)
Frontispiece: Stainless Steel‐Like Passivation Inspires Persistent Silicon Anodes for Lithium‐Ion Batteries
- 11 January 2023
- Published by Wiley in Angewandte Chemie
- Vol. 135 (11)
Stainless Steel‐Like Passivation Inspires Persistent Silicon Anodes for Lithium‐Ion Batteries
Passivation of stainless steel by additives forming mass‐transport blocking layers is widely practiced, where Cr element is added into bulk Fe−C forming the Cr2O3‐rich protective layer. Here we extend the long‐practiced passivation concept to Si anodes for lithium‐ion batteries, incorporating the passivator of LiF/Li2CO3 into bulk Si. The passivation mechanism is studied by various ex situ characterizations, redox peak contour maps, thickness evolution tests, and finite element simulations. The results demonstrate that the passivation can enhance the (de)lithiation of Li‐Si alloys, induce the formation of F‐rich solid electrolyte interphase, stabilize the Si/LiF/Li2CO3 composite, and mitigate the volume change of Si anodes upon cycling. The 3D passivated Si anode can fully retain a high capacity of 3701 mAh g−1 after 1500 cycles and tolerate high rates up to 50C. This work provides insight into how to construct durable Si anodes through effective passivation.
- 11 January 2023
- Published by Wiley in Angewandte Chemie
- Vol. 135 (11)
Stainless Steel‐Like Passivation Inspires Persistent Silicon Anodes for Lithium‐Ion Batteries
Passivation of stainless steel by additives forming mass‐transport blocking layers is widely practiced, where Cr element is added into bulk Fe−C forming the Cr2O3‐rich protective layer. Here we extend the long‐practiced passivation concept to Si anodes for lithium‐ion batteries, incorporating the passivator of LiF/Li2CO3 into bulk Si. The passivation mechanism is studied by various ex situ characterizations, redox peak contour maps, thickness evolution tests, and finite element simulations. The results demonstrate that the passivation can enhance the (de)lithiation of Li‐Si alloys, induce the formation of F‐rich solid electrolyte interphase, stabilize the Si/LiF/Li2CO3 composite, and mitigate the volume change of Si anodes upon cycling. The 3D passivated Si anode can fully retain a high capacity of 3701 mAh g−1 after 1500 cycles and tolerate high rates up to 50C. This work provides insight into how to construct durable Si anodes through effective passivation.
- 11 January 2023
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 62 (11) , e202216557
Stainless Steel‐Like Passivation Inspires Persistent Silicon Anodes for Lithium‐Ion Batteries
Passivation of stainless steel by additives forming mass‐transport blocking layers is widely practiced, where Cr element is added into bulk Fe−C forming the Cr2O3‐rich protective layer. Here we extend the long‐practiced passivation concept to Si anodes for lithium‐ion batteries, incorporating the passivator of LiF/Li2CO3 into bulk Si. The passivation mechanism is studied by various ex situ characterizations, redox peak contour maps, thickness evolution tests, and finite element simulations. The results demonstrate that the passivation can enhance the (de)lithiation of Li‐Si alloys, induce the formation of F‐rich solid electrolyte interphase, stabilize the Si/LiF/Li2CO3 composite, and mitigate the volume change of Si anodes upon cycling. The 3D passivated Si anode can fully retain a high capacity of 3701 mAh g−1 after 1500 cycles and tolerate high rates up to 50C. This work provides insight into how to construct durable Si anodes through effective passivation.
- 11 January 2023
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 62 (11) , e202216557
Stainless Steel‐Like Passivation Inspires Persistent Silicon Anodes for Lithium‐Ion Batteries
Passivation of stainless steel by additives forming mass‐transport blocking layers is widely practiced, where Cr element is added into bulk Fe−C forming the Cr2O3‐rich protective layer. Here we extend the long‐practiced passivation concept to Si anodes for lithium‐ion batteries, incorporating the passivator of LiF/Li2CO3 into bulk Si. The passivation mechanism is studied by various ex situ characterizations, redox peak contour maps, thickness evolution tests, and finite element simulations. The results demonstrate that the passivation can enhance the (de)lithiation of Li‐Si alloys, induce the formation of F‐rich solid electrolyte interphase, stabilize the Si/LiF/Li2CO3 composite, and mitigate the volume change of Si anodes upon cycling. The 3D passivated Si anode can fully retain a high capacity of 3701 mAh g−1 after 1500 cycles and tolerate high rates up to 50C. This work provides insight into how to construct durable Si anodes through effective passivation.
- 27 April 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (18) , 7148-7149
Detlev Müller’s Discovery of Glucose Oxidase in 1925
- 27 April 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (18) , 7148-7149
Detlev Müller’s Discovery of Glucose Oxidase in 1925
- 16 February 2021
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 13 (8) , 9985-9993
Li–Zn Overlayer to Facilitate Uniform Lithium Deposition for Lithium Metal Batteries
The highly reactive nature and rough surface of Li foil can lead to the uncontrollable formation of Li dendrites when employed as an anode in a lithium metal battery. Thus, it could be of great practical utility to create uniform, electrochemically stable, and “lithiophilic” surfaces to realize homogeneous deposition of Li. Herein, a LiZn alloy layer is deposited on the surface of Li foil by e-beam evaporation. The idea is to introduce a uniform alloy surface to increase the active area and make use of the Zn sites to induce homogeneous nucleation of Li. The results show that the alloy film protected the Li metal anode, allowing for a longer cycling life with a lower deposition overpotential over a pure-Li metal anode in symmetric Li cells. Furthermore, full cells pairing the modified lithium anode with a LiFePO4 cathode showed an incremental increase in Coulombic efficiency compared with pure-Li. The concept of using only an alloy modifying layer by an in-situ e-beam deposition synthesis method offers a potential method for enabling lithium metal anodes for next-generation lithium batteries.
- 16 February 2021
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 13 (8) , 9985-9993
Li–Zn Overlayer to Facilitate Uniform Lithium Deposition for Lithium Metal Batteries
The highly reactive nature and rough surface of Li foil can lead to the uncontrollable formation of Li dendrites when employed as an anode in a lithium metal battery. Thus, it could be of great practical utility to create uniform, electrochemically stable, and “lithiophilic” surfaces to realize homogeneous deposition of Li. Herein, a LiZn alloy layer is deposited on the surface of Li foil by e-beam evaporation. The idea is to introduce a uniform alloy surface to increase the active area and make use of the Zn sites to induce homogeneous nucleation of Li. The results show that the alloy film protected the Li metal anode, allowing for a longer cycling life with a lower deposition overpotential over a pure-Li metal anode in symmetric Li cells. Furthermore, full cells pairing the modified lithium anode with a LiFePO4 cathode showed an incremental increase in Coulombic efficiency compared with pure-Li. The concept of using only an alloy modifying layer by an in-situ e-beam deposition synthesis method offers a potential method for enabling lithium metal anodes for next-generation lithium batteries.
- 21 December 2020
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 15 (1) , 29-46
Recent Developments in Dendrite-Free Lithium-Metal Deposition through Tailoring of Micro- and Nanoscale Artificial Coatings
Forty years after the failed introduction of rechargeable lithium-metal batteries and 30 years after the successful commercialization of the lower capacity, graphite-anode-based lithium-ion battery by Sony, demand for higher energy density batteries is leading to reinvestigation of the problem of dendrite growth that makes the metallic lithium anodes unsafe and prevented commercialization to begin with. One strategy to mitigate dendrite growth is to deposit thin, tailored, corrosion-passivating coatings on the metallic lithium, instead of allowing the metal to spontaneously react with the organic electrolyte solution to form its passivating solid electrolyte interface (SEI). The challenge is to find and to deposit a coating that is electronically insulating yet allows uniform permeation of Li+ at a high cycling rate, such that Li-metal is electrodeposited uniformly on the nanoscale below the tailored coating. Recently, a number of studies have examined multicomponent films, taking advantage of the properties of two different materials, which can be tuned separately or chosen for their complementary properties. Use of these multicomponent coatings will likely enable future researchers to create rationally designed SEIs capable of effectively suppressing the growth of Li dendrites. This review discusses recent developments in micro- and nanoscale tailored coatings to meet that need.
- 21 December 2020
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 15 (1) , 29-46
Recent Developments in Dendrite-Free Lithium-Metal Deposition through Tailoring of Micro- and Nanoscale Artificial Coatings
Forty years after the failed introduction of rechargeable lithium-metal batteries and 30 years after the successful commercialization of the lower capacity, graphite-anode-based lithium-ion battery by Sony, demand for higher energy density batteries is leading to reinvestigation of the problem of dendrite growth that makes the metallic lithium anodes unsafe and prevented commercialization to begin with. One strategy to mitigate dendrite growth is to deposit thin, tailored, corrosion-passivating coatings on the metallic lithium, instead of allowing the metal to spontaneously react with the organic electrolyte solution to form its passivating solid electrolyte interface (SEI). The challenge is to find and to deposit a coating that is electronically insulating yet allows uniform permeation of Li+ at a high cycling rate, such that Li-metal is electrodeposited uniformly on the nanoscale below the tailored coating. Recently, a number of studies have examined multicomponent films, taking advantage of the properties of two different materials, which can be tuned separately or chosen for their complementary properties. Use of these multicomponent coatings will likely enable future researchers to create rationally designed SEIs capable of effectively suppressing the growth of Li dendrites. This review discusses recent developments in micro- and nanoscale tailored coatings to meet that need.
- 7 December 2020
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 14 (12) , 17142-17150
Stabilization of a Highly Ni-Rich Layered Oxide Cathode through Flower-Petal Grain Arrays
Nickel adds to the capacity of layered oxide cathodes of lithium-ion batteries but comprises their stability. We report a petal-grained Li[Ni0.89Co0.10Sb0.01]O2 cathode that is, nevertheless, stable. The stability originates from the ordering of the nanosized grains in a dense, flower-petal-like array, where the elongated and nearly parallel grains radiate from the center to the surface. The ordering of the grains prevents microcrack generation from abrupt lattice changes of the stressful H2–H3 phase transition. The tight packing of the nanograins is conserved upon cycling, preventing destructive seepage of the electrolytic solution into the particles. The half-cell, cycling between 2.7–4.3 V versus Li/Li+ at a 0.5 C rate retains 95.0% of its initial capacity of 220 mAh g–1 after 100 cycles. The full-cell, cycling with a graphite anode and between 3.0–4.2 V at a 1 C rate, retains 83.9% of its initial capacity after 1000 cycles.
- 7 December 2020
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 14 (12) , 17142-17150
Stabilization of a Highly Ni-Rich Layered Oxide Cathode through Flower-Petal Grain Arrays
Nickel adds to the capacity of layered oxide cathodes of lithium-ion batteries but comprises their stability. We report a petal-grained Li[Ni0.89Co0.10Sb0.01]O2 cathode that is, nevertheless, stable. The stability originates from the ordering of the nanosized grains in a dense, flower-petal-like array, where the elongated and nearly parallel grains radiate from the center to the surface. The ordering of the grains prevents microcrack generation from abrupt lattice changes of the stressful H2–H3 phase transition. The tight packing of the nanograins is conserved upon cycling, preventing destructive seepage of the electrolytic solution into the particles. The half-cell, cycling between 2.7–4.3 V versus Li/Li+ at a 0.5 C rate retains 95.0% of its initial capacity of 220 mAh g–1 after 100 cycles. The full-cell, cycling with a graphite anode and between 3.0–4.2 V at a 1 C rate, retains 83.9% of its initial capacity after 1000 cycles.