FCFrancesca Canalias

Francesca Canalias

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Francesca Canalias has a total of 85 co-authors. Here are the top co-authors by number of shared publications:

  • F.-Javier Gella

    Biosystems S.A., Barcelona, Spain

    10 shared publications
  • Ferruccio Ceriotti

    Microbiology and Virology Unit and Clinical Pathology Laboratory, Foundation IRCCS Ca’ Granda Ospedale Maggiore Policlinico, 20122 Milan, Italy

    5 shared publications
  • Maribel Sánchez

    Departamento de Investigación y Desarrollo, División Reactivos, BioSystems, S.A., Barcelona, Spain

    4 shared publications
  • Yolanda Saco

    Servei de Bioquímica Clínica Veterinària (SBCV); Departament de Bioquímica i Biologia Molecular; Facultat de Veterinària; Universitat Autònoma de Barcelona; Barcelona Spain

    4 shared publications
  • Alexandre Bota

    Departament de Bioquímica i de Biologia Molecular, Unitat de Bioquímica de Medicina, Universitat Autònoma de Barcelona, Edifici M, 08193 Bellaterra, Spain

    3 shared publications
  • Anna Bassols

    Universitat Autònoma de Barcelona Veterinary Clinical Biochemistry Service (SBCV), Department of Biochemistry and Molecular Biology, School of Veterinary Bellaterra, 08193

    3 shared publications

Latest Publications

  • Measurement uncertainty and metrological traceability of whole blood cyclosporin A mass concentration results obtained by UHPLC-MS/MS

    by Raül Rigo-Bonnin, Pedro Alía, Francesca Canalias

    Background: Traceable and accurate results of cyclosporine A (CsA) mass concentrations in whole blood are required to ensure the monitoring of immunosuppressive therapy in transplant recipients. Metrological traceability and measurement uncertainty can allow ensuring reliability and comparability of these results over time and space. In this study, we provide a practical and detailed example of how the traceability and uncertainty of mass concentration of CsA results, obtained using an ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) procedure, can be described and estimated. Methods: Traceability was described mainly according to ISO 17511 and information obtained from certificates facilitated with the manufacturer’s calibrators. Uncertainty estimation was performed using the bottom-up and top-down approaches. For the bottom-up approach, the most relevant sources of uncertainty were identified and later used to estimate the standard, combined and expanded uncertainties. For the top-down approach, expanded uncertainty was estimated directly using intralab quality control data mainly. Results: Mass concentration of CsA results was traceable to the manufacturer’s product calibrators used to calibrate the UHPLC-MS/MS procedure. The expanded uncertainties estimated by the bottom-up and top-down approaches were 7.4% and 7.2%, respectively. Conclusions: After performing the bottom-up and top-down approaches, we observed that their results were quite similar. This fact would confirm that the top-down approach could be sufficient for estimating uncertainty of CsA mass concentrations in whole blood results in clinical laboratories. Finally, we hope that this study can help and motivate clinical laboratories to describe metrological traceability and to perform measurement uncertainty studies based on the simpler top-down approach.


  • Preparation of canine C-reactive protein serum reference material: A feasibility study

    by Francesca Canalias, Matilde Piñeiro, Raquel Pato, Raquel Peña, Lluís Bosch, Lourdes Soler, Natalia García, Fermín Lampreave, Yolanda Saco, Anna Bassols

    Background The availability of a species‐specific reference material is essential for the harmonization of results obtained in different laboratories by different methods. Objectives We describe the preparation of a canine C‐reactive protein (cCRP) serum reference material containing purified cCRP stabilized in a serum matrix. The material can be used by manufacturers to assign values to their calibrator and control materials. Methods The serum matrix was obtained using blood collected from healthy dogs, stabilized and submitted for a delipidation process. The reference material was prepared by diluting purified cCRP in the serum matrix containing 1.0 mol/L HEPES buffer, 3.0 mmol/L calcium chloride, 80,000 kUI/L aprotinin, and 1.0 mmol/L benzamidine hydrochloride monohydrate at a pH of 7.2, and dispensing (0.5 mL) the matrix into vials that were then frozen. Results The pilot batch of 200 vials was shown to be homogeneous and stable after a stability study at various temperatures and over a total time of 110 days. The prepared material was submitted to an assignment value study. Eight laboratories from different European countries participated by using the same reagents for an immunoturbidimetric method adapted for different analyzers. The obtained cCRP concentration in the reference material was 78.5 mg/L with an expanded uncertainty (k = 2) of 4.2 mg/L. Conclusions Canine C‐reactive protein serum reference material has been produced that allows harmonization of results obtained by different methods and different laboratories, thus reducing the possibility of errors and misunderstandings.


  • A new automated turbidimetric immunoassay for the measurement of canine C‐reactive protein

    by Matilde Piñeiro, Raquel Pato, Lourdes Soler, Raquel Peña, Natalia García, Carlos Torrente, Yolanda Saco, Fermín Lampreave, Anna Bassols, Francesca Canalias

    Background: In dogs, as in humans, C‐reactive protein (CRP) is a major acute phase protein that is rapidly and prominently increased after exposure to inflammatory stimuli. CRP measurements are used in the diagnosis and monitoring of infectious and inflammatory diseases.Objectives: The study aim was to develop and validate a turbidimetric immunoassay for the quantification of canine CRP (cCRP), using canine‐specific reagents and standards.Methods: A particle‐enhanced turbidimetric immunoassay was developed. The assay was set up in a fully automated analyzer, and studies of imprecision, limits of linearity, limits of detection, prozone effects, and interferences were carried out. The new method was compared with 2 other commercially available automated immunoassays for cCRP: one turbidimetric immunoassay (Gentian CRP) and one point‐of‐care assay based on magnetic permeability (Life Assays CRP).Results: The within‐run and between‐day imprecision were 320 mg/L. No interference from hemoglobin (20 g/L), triglycerides (10 g/L), or bilirubin (150 mg/L) was detected. Good agreement was observed between the results obtained with the new method and the Gentian cCRP turbidimetric immunoassay.Conclusions: The new turbidimetric immunoassay (Turbovet canine CRP, Acuvet Biotech) is a rapid, robust, precise, and accurate method for the quantification of cCRP. The method can be easily set up in automated analyzers, providing a suitable tool for routine clinical use.


  • An approach to establish the uncertainty budget of catalytic activity concentration measurements in a reference laboratory

    by Laura Rami, Francesca Canalias

    Background: Reference laboratories providing reference services recognized by the Joint Committee for Traceability in Laboratory Medicine (JCTLM) must be accredited as calibration laboratories according to ISO 17025 and ISO 15195. These standards require laboratories to establish an uncertainty budget, in which the uncertainty contributions of the relevant uncertainty components are specified. We present a model to estimate the measurement uncertainty of creatine kinase catalytic activity concentration results obtained by IFCC primary reference measurement procedure. Methods: The measurement uncertainty has been estimated by following the next steps: 1) specification of the measurand; 2) identification of the most relevant uncertainty sources; 3) estimation of standard uncertainties by either type A or type B evaluation; 4) estimation of combined uncertainty while taking into account sensitivity coefficients, as well as existence of correlated uncertainty sources; and 5) estimation of expanded uncertainty with a defined coverage probability. Results: The estimated expanded uncertainty was 2.2% (k=2). Uncertainty sources with a significant contribution to the measurement uncertainty were the following: pH adjustment (0.68%), absorbance accuracy (0.48%), wavelength adjustment (0.20%), reaction temperature (0.19%), volume fraction of sample (0.15%) and absorbance linearity (0.06%). Conclusions: The present model is an approach to establish the uncertainty budget of primary reference procedures for the measurement of the catalytic activity concentration of enzymes, and aims at being an example to be followed by other reference laboratories, as well as by laboratories that carry out primary reference measurement procedures.


  • IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 °C. Part 9: Reference procedure for the measurement of catalytic concentration of alkaline phosphatase

    by Gerhard Schumann, Rainer Klauke, Francesca Canalias, Steffen Bossert-Reuther, Paul F.H. Franck, F.-Javier Gella, Poul J. Jørgensen, Dongchon Kang, Jean-Marc Lessinger, Mauro Panteghini, et al.

    This paper is the ninth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 °C and the certification of reference preparations. Other parts deal with: Part 1. The concept of reference procedures for the measurement of catalytic activity concentrations of enzymes; Part 2. Reference procedure for the measurement of catalytic concentration of creatine kinase; Part 3. Reference procedure for the measurement of catalytic concentration of lactate dehydrogenase; Part 4. Reference procedure for the measurement of catalytic concentration of alanine aminotransferase; Part 5. Reference procedure for the measurement of catalytic concentration of aspartate aminotransferase; Part 6. Reference procedure for the measurement of catalytic concentration of γ-glutamyltransferase; Part 7. Certification of four reference materials for the determination of enzymatic activity of γ-glutamyltransferase, lactate dehydrogenase, alanine aminotransferase and creatine kinase at 37 °C; Part 8. Reference procedure for the measurement of catalytic concentration of α-amylase. The procedure described here is derived from the previously described 30 °C IFCC reference method. Differences are tabulated and commented on in Appendix 1.


  • Validation of an immunoturbidimetric method for determination of porcine serum C-reactive protein

    by Yolanda Saco, Lorenzo Fraile, Mercè Giménez, Francesca Canalias, Anna Bassols


  • IFCC reference procedures for measurement of the catalytic concentrations of enzymes: corrigendum, notes and useful advice

    by Gerhard Schumann, Francesca Canalias, Poul J. Joergensen, Dongchon Kang, Jean-Marc Lessinger, Rainer Klauke, on behalf of the Committee on Reference Systems for Enzymes

    The primary reference measurement procedures (PRMPs) for the international standardization of catalytic concentration measurements of α-amylase, alanine aminotransferase, aspartate aminotransferase (AST), creatine kinase (CK), γ-glutamyltransferase and lactate dehydrogenase have been performed in reference laboratories for several years. The IFCC Committee on Reference Systems for Enzymes and two reference laboratories, with official accreditation for the PRMPs, have collected useful information on some of the steps of the reference procedures that require special attention. This document comprises errata corrige for minor mistakes in published PRMPs for AST and CK. Several notes on the PRMPs are emphasized. This includes details that are very important for improved standardization, and general suggestions for reducing measurement uncertainty. Clin Chem Lab Med 2010;48:615–21.