Tran Thien Thanh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tran Thien Thanh has a total of 192 co-authors. Here are the top co-authors by number of shared publications:
Chau Van Tao
26 shared publicationsHuynh Dinh Chuong
18 shared publicationsVo Hoang Nguyen
Department of Nuclear Physics, Faculty of Physics and Engineering Physics, University of Science, Ho Chi Minh City, Vietnam
12 shared publicationsPhan Long Ho
10 shared publications- Hoang Duc Tam
Faculty of Physics, Ho Chi Minh City University of Education, Ho Chi Minh City, Viet Nam
9 shared publications - Huynh Dinh Chuong
Nuclear Technique Laboratory, University of Science, Ho Chi Minh City, Viet Nam
7 shared publications
Latest Publications
- Open Access
- 7 March 2026
- Published by Elsevier in SSRN Electronic Journal
Bulk density determination of concrete by gamma-ray transmission using a 137Cs source and NaI(Tl) spectrometry: MCNP-based calibration and experimental validation across varying aggregate compositions
This paper presents a gamma-ray transmission method for the non-destructive determination of concrete bulk density. The experimental setup comprises a 137Cs source, a NaI(Tl) detector, and lead collimators arranged in a narrow-beam transmission geometry. An MCNP model was developed to closely replicate the measurement configuration and was subsequently used to generate pulse-height spectra for elemental and concrete specimens covering densities of 2.10 – 8.96 g.cm-3 and thicknesses of 1 – 15 cm. From each spectrum, the net area of the 661.7 keV peak was extracted, and the attenuation indicator R was defined as the ratio of the peak areas recorded with and without the specimen. The simulations were benchmarked against measurements for aluminum and copper reference specimens at different thicknesses, showing good agreement in spectral response and relative deviations between simulated and experimental R values below 0.8%. Using the simulated R dataset, a linear calibration curve was established, enabling concrete bulk density to be determined without prior knowledge of the elemental composition. The method was applied to 22 concrete specimens fabricated with different aggregate systems, including ordinary concretes and concretes incorporating heavyweight additives (e.g., barite, Bi2O3, Fe2O3, and steel chips). These specimens covered densities of 2.2 – 2.6 g.cm-3 and thicknesses of 3 – 15 cm. Each specimen was measured at nine locations to assess spatial variability, and the weighted mean was taken as the representative bulk density. The resulting densities agree well with reference values obtained from mass-to-volume measurements, with relative deviations not exceeding 3.74% for all specimens. A coverage-probability–based statistical framework, augmented by additional sampling, was introduced to assess and improve measurement reliability when structural heterogeneity produces spatial variations in the inferred density. These preliminary results demonstrate that the proposed method is reliable and well suited for rapid concrete quality control.
- 7 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessBulk density determination of concrete by gamma-ray transmission using a 137Cs source and NaI(Tl) spectrometry: MCNP-based calibration and experimental validation across varying aggregate compositions
This paper presents a gamma-ray transmission method for the non-destructive determination of concrete bulk density. The experimental setup comprises a 137Cs source, a NaI(Tl) detector, and lead collimators arranged in a narrow-beam transmission geometry. An MCNP model was developed to closely replicate the measurement configuration and was subsequently used to generate pulse-height spectra for elemental and concrete specimens covering densities of 2.10 – 8.96 g.cm-3 and thicknesses of 1 – 15 cm. From each spectrum, the net area of the 661.7 keV peak was extracted, and the attenuation indicator R was defined as the ratio of the peak areas recorded with and without the specimen. The simulations were benchmarked against measurements for aluminum and copper reference specimens at different thicknesses, showing good agreement in spectral response and relative deviations between simulated and experimental R values below 0.8%. Using the simulated R dataset, a linear calibration curve was established, enabling concrete bulk density to be determined without prior knowledge of the elemental composition. The method was applied to 22 concrete specimens fabricated with different aggregate systems, including ordinary concretes and concretes incorporating heavyweight additives (e.g., barite, Bi2O3, Fe2O3, and steel chips). These specimens covered densities of 2.2 – 2.6 g.cm-3 and thicknesses of 3 – 15 cm. Each specimen was measured at nine locations to assess spatial variability, and the weighted mean was taken as the representative bulk density. The resulting densities agree well with reference values obtained from mass-to-volume measurements, with relative deviations not exceeding 3.74% for all specimens. A coverage-probability–based statistical framework, augmented by additional sampling, was introduced to assess and improve measurement reliability when structural heterogeneity produces spatial variations in the inferred density. These preliminary results demonstrate that the proposed method is reliable and well suited for rapid concrete quality control.
- 18 February 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1086
A dual-energy gamma-ray transmission method using 137Cs and 241Am sources for determining effective atomic number and mass attenuation coefficient of lightweight materials
- 18 February 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1086
A dual-energy gamma-ray transmission method using 137Cs and 241Am sources for determining effective atomic number and mass attenuation coefficient of lightweight materials
- Open Access
- 13 July 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (7) , e70144
Novel validation of HDR brachytherapy dosimetry for cervical cancer using egs_brachy Monte Carlo simulations: a comparative analysis with Oncentra treatment planning system
Purpose: This study aims to validate HDR brachytherapy dosimetry for cervical cancer patients utilizing the egs_brachy Monte Carlo (MC) simulation. Methods: Three cervical cancer patients treated with 192 Ir HDR brachytherapy were included. Dose distributions were calculated by the Oncentra Brachy v4 treatment planning system (TPS) based on AAPM TG‐43. The newly developed eb_gui, an egs_brachy graphical user interface for MC simulations, was applied in recalculating dose distributions for 12 fractions using digital imaging and communications in medicine‐radiotherapy (DICOM‐RT) anatomical information. Comparisons were made for clinical target volume (CTV), bladder, and rectum using dose–volume histograms (DVH) and clinically relevant plan quality indices. Results: TPS‐calculated doses were greater than those obtained from MC simulations. For the CTV, the median percentage differences were 7.9% (Q1: 6.4%, Q3: 9.8%; range: 0.4%–10.4%) for D 90 . For the bladder, the median percentage differences were 0.7% (Q1: 0.4%, Q3: 2.3%; range: −9.4–5.4%) for D 2cc . For the rectum, the median percentage differences were 3.6% (Q1: 2.8%, Q3: 5.6%; range: 0.9%–6.4%) for D 2cc . Conclusion: CTV and critical organ doses calculated by the TPS were consistently greater than those obtained from MC simulations. This suggests that the TPS may overestimate dose distributions, especially in heterogeneous regions like the pelvis. These results emphasize the need for continued validation of TPS algorithms in HDR brachytherapy for cervical cancer.
- 13 July 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (7) , e70144
Open AccessNovel validation of HDR brachytherapy dosimetry for cervical cancer using egs_brachy Monte Carlo simulations: a comparative analysis with Oncentra treatment planning system
Purpose: This study aims to validate HDR brachytherapy dosimetry for cervical cancer patients utilizing the egs_brachy Monte Carlo (MC) simulation. Methods: Three cervical cancer patients treated with 192 Ir HDR brachytherapy were included. Dose distributions were calculated by the Oncentra Brachy v4 treatment planning system (TPS) based on AAPM TG‐43. The newly developed eb_gui, an egs_brachy graphical user interface for MC simulations, was applied in recalculating dose distributions for 12 fractions using digital imaging and communications in medicine‐radiotherapy (DICOM‐RT) anatomical information. Comparisons were made for clinical target volume (CTV), bladder, and rectum using dose–volume histograms (DVH) and clinically relevant plan quality indices. Results: TPS‐calculated doses were greater than those obtained from MC simulations. For the CTV, the median percentage differences were 7.9% (Q1: 6.4%, Q3: 9.8%; range: 0.4%–10.4%) for D 90 . For the bladder, the median percentage differences were 0.7% (Q1: 0.4%, Q3: 2.3%; range: −9.4–5.4%) for D 2cc . For the rectum, the median percentage differences were 3.6% (Q1: 2.8%, Q3: 5.6%; range: 0.9%–6.4%) for D 2cc . Conclusion: CTV and critical organ doses calculated by the TPS were consistently greater than those obtained from MC simulations. This suggests that the TPS may overestimate dose distributions, especially in heterogeneous regions like the pelvis. These results emphasize the need for continued validation of TPS algorithms in HDR brachytherapy for cervical cancer.
- 6 May 2025
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 334 (5) , 3819-3831
Combination of experimental and simulation methods for determination of effective atomic number by Rayleigh-Compton scattering technique
- 6 May 2025
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 334 (5) , 3819-3831
Combination of experimental and simulation methods for determination of effective atomic number by Rayleigh-Compton scattering technique
- 14 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (4) , 1516-1524
An Assessment of External Dose From Natural Radioactivity in Building Materials by Using Simulation Monte Carlo
Aside from the natural background ionizing radiation that humans are constantly exposed to, there is a significant risk of elevated radiation levels from building materials with enhanced radioactivity. Given the time individuals spend indoors, this study is crucial in assessing the external radiation dose from commonly used construction materials. A room model with dimensions 5 4 2.8 m and walls 20 cm thick was developed to simulate radiation doses from materials such as cement, brick, sand, and rock collected from suppliers in Ho Chi Minh City, Vietnam. Absorbed dose rates from radionuclides, specifically 238U, 232Th, and 40K, were calculated using the Monte Carlo N-Particle Transport code (MCNP6), with phantom water used to represent the dose absorption medium. The results indicate that the external radiation doses ranged from 0.11 – 0.64 mSv/y for sand, 0.47 – 0.79 mSv/y for cement, 1.07 – 1.58 mSv/y and 1.00 mSv/y for brick and rock, respectively. While most measured doses were below the reference value, specific brick samples exceeded these thresholds. In addition, a comparative analysis was conducted using the RESRAD-BUILD code, with dosimetric data derived from the ICRP 38 library. The comparison between MCNP6 and RESRADBUILD results showed a good agreement with relative deviations of less than 12%, underscoring the accuracy and reliability of the model. These findings suggest that the proposed methodology provides a reliable and efficient approach for quantifying external radiation doses from building materials, thus contributing to improved radiation safety assessments in indoor environments.
- 14 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (4) , 1516-1524
An Assessment of External Dose From Natural Radioactivity in Building Materials by Using Simulation Monte Carlo
Aside from the natural background ionizing radiation that humans are constantly exposed to, there is a significant risk of elevated radiation levels from building materials with enhanced radioactivity. Given the time individuals spend indoors, this study is crucial in assessing the external radiation dose from commonly used construction materials. A room model with dimensions 5 4 2.8 m and walls 20 cm thick was developed to simulate radiation doses from materials such as cement, brick, sand, and rock collected from suppliers in Ho Chi Minh City, Vietnam. Absorbed dose rates from radionuclides, specifically 238U, 232Th, and 40K, were calculated using the Monte Carlo N-Particle Transport code (MCNP6), with phantom water used to represent the dose absorption medium. The results indicate that the external radiation doses ranged from 0.11 – 0.64 mSv/y for sand, 0.47 – 0.79 mSv/y for cement, 1.07 – 1.58 mSv/y and 1.00 mSv/y for brick and rock, respectively. While most measured doses were below the reference value, specific brick samples exceeded these thresholds. In addition, a comparative analysis was conducted using the RESRAD-BUILD code, with dosimetric data derived from the ICRP 38 library. The comparison between MCNP6 and RESRADBUILD results showed a good agreement with relative deviations of less than 12%, underscoring the accuracy and reliability of the model. These findings suggest that the proposed methodology provides a reliable and efficient approach for quantifying external radiation doses from building materials, thus contributing to improved radiation safety assessments in indoor environments.
- 4 September 2024
- Published by Springer Nature in Environmental Geochemistry and Health
- Vol. 46 (10) , 1-19
Assessment of physicochemical properties and radioactivity in groundwater at households living in bac Lieu province, vietnam
This paper presents findings on groundwater physiochemical composition and radioactivity levels in households in Bac Lieu province, Vietnam. Through discriminant analysis, it was observed that groundwater quality exhibits spatial variations corresponding to saline intrusion zones. The paired-samples T-tests revealed significantly different ratios of Ra-224, Ra-226, and Ra-228 isotopes between Na–Cl and Ca–Na–HCO3 water types. All three water types had a ratio of Ra-226/Ra-228 of approximately one, indicating the presence of groundwater aquifers beneath the crust and fluvial marine sediment. Furthermore, strong associations between sulfate and calcium suggest that CO2 enrichment in groundwater aquifers indicates anoxic aquatic environments. Twenty-five of the thirty-three evaluated samples exceeded the national technical regulations for domestic water quality with parameters such as chloride, sulfate, sodium, gross alpha, or total dissolved solids. Fifteen samples exceeded gross alpha's allowable contamination threshold of 0.1 Bq/L. The combination of Ra-226 and Ra-228 did not surpass the U.S. Environmental Protection Agency's recommended limit of 0.185 Bq/L. However, nineteen samples exhibited annual committed effective doses of radium isotopes for infants that exceeded the WHO recommendation of 0.1 mSv/year.
- 4 September 2024
- Published by Springer Nature in Environmental Geochemistry and Health
- Vol. 46 (10) , 1-19
Assessment of physicochemical properties and radioactivity in groundwater at households living in bac Lieu province, vietnam
This paper presents findings on groundwater physiochemical composition and radioactivity levels in households in Bac Lieu province, Vietnam. Through discriminant analysis, it was observed that groundwater quality exhibits spatial variations corresponding to saline intrusion zones. The paired-samples T-tests revealed significantly different ratios of Ra-224, Ra-226, and Ra-228 isotopes between Na–Cl and Ca–Na–HCO3 water types. All three water types had a ratio of Ra-226/Ra-228 of approximately one, indicating the presence of groundwater aquifers beneath the crust and fluvial marine sediment. Furthermore, strong associations between sulfate and calcium suggest that CO2 enrichment in groundwater aquifers indicates anoxic aquatic environments. Twenty-five of the thirty-three evaluated samples exceeded the national technical regulations for domestic water quality with parameters such as chloride, sulfate, sodium, gross alpha, or total dissolved solids. Fifteen samples exceeded gross alpha's allowable contamination threshold of 0.1 Bq/L. The combination of Ra-226 and Ra-228 did not surpass the U.S. Environmental Protection Agency's recommended limit of 0.185 Bq/L. However, nineteen samples exhibited annual committed effective doses of radium isotopes for infants that exceeded the WHO recommendation of 0.1 mSv/year.