Bennett P. Samuel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bennett P. Samuel has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
- Joseph John Vettukattil
Spectrum Health Helen DeVos Children’s Hospital
17 shared publications - Jordan M. Gosnell
Betz Advanced Visualization and Innovation Center, Corewell Health Helen DeVos Children's Hospital, Grand Rapids, Michigan
5 shared publications E. Oliver Aregullin
Congenital Heart Center, Spectrum Health Helen DeVos Children’s Hospital, Grand Rapids, MI, USA
4 shared publicationsJoseph J. Vettukattil
Congenital Heart Center, Spectrum Health Helen DeVos Children’s Hospital, Grand Rapids, MI, USA
4 shared publications- Bassel Mohammad Nijres
Division of Pediatric Cardiology, King Faisal Specialist Hospital and Research Centre, Jeddah, Saudi Arabia
3 shared publications Darcy N. Marckini
Congenital Heart Center, Spectrum Health Helen DeVos Children's Hospital, Grand Rapids, Michigan, USA
3 shared publications
Latest Publications
- 15 April 2021
- Published by SAGE Publications in Journal of Intensive Care Medicine
- Vol. 36 (6) , 726-728
Emergency Use of Occlutech® Atrial Flow Regulator Device Facilitates Weaning From Veno-Arterial Extracorporeal Membrane Oxygenation in a Patient With Severe Pulmonary Arterial Hypertension
Pulmonary arterial hypertension (PAH) is a severe and progressive disease. Treatment options include anti-PAH medications, continuous intravenous therapies, and diuretics. Lung transplant is required in many cases. Atrial septostomy is an under recognized option in symptomatic patients on maximal PAH therapy. However, creating a sustainable and restrictive atrial communication is challenging with existing devices. We describe emergency use of the Occlutech® Atrial Flow Regulator, a novel device, in a 35-year-old female with PAH supported on veno-arterial extracorporeal membrane oxygenation after postpartum decompensation.
- 15 April 2021
- Published by SAGE Publications in Journal of Intensive Care Medicine
- Vol. 36 (6) , 726-728
Emergency Use of Occlutech® Atrial Flow Regulator Device Facilitates Weaning From Veno-Arterial Extracorporeal Membrane Oxygenation in a Patient With Severe Pulmonary Arterial Hypertension
Pulmonary arterial hypertension (PAH) is a severe and progressive disease. Treatment options include anti-PAH medications, continuous intravenous therapies, and diuretics. Lung transplant is required in many cases. Atrial septostomy is an under recognized option in symptomatic patients on maximal PAH therapy. However, creating a sustainable and restrictive atrial communication is challenging with existing devices. We describe emergency use of the Occlutech® Atrial Flow Regulator, a novel device, in a 35-year-old female with PAH supported on veno-arterial extracorporeal membrane oxygenation after postpartum decompensation.
- 12 April 2021
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 31 (10) , 1690-1692
Planned reduction in Fontan fenestration size using the Atrial Flow Regulator
Fontan fenestration allows right-to-left shunting increasing cardiac output and oxygen delivery. Increased shunting occurs as cardiac function and ventricular end-diastolic pressures improve, potentially decreasing oxygen saturation. Complete closure may result in impaired Fontan haemodynamics and low cardiac output; however, there are no dedicated devices to reduce fenestration size. We describe Fontan fenestration size reduction using the Atrial Flow Regulator.
- 12 April 2021
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 31 (10) , 1690-1692
Planned reduction in Fontan fenestration size using the Atrial Flow Regulator
Fontan fenestration allows right-to-left shunting increasing cardiac output and oxygen delivery. Increased shunting occurs as cardiac function and ventricular end-diastolic pressures improve, potentially decreasing oxygen saturation. Complete closure may result in impaired Fontan haemodynamics and low cardiac output; however, there are no dedicated devices to reduce fenestration size. We describe Fontan fenestration size reduction using the Atrial Flow Regulator.
- 1 July 2020
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 36 (7) , 1098-1103
Complex Determinants of Work Ability in Adults With Congenital Heart Disease and Implications for Clinical Practice
- 1 July 2020
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 36 (7) , 1098-1103
Complex Determinants of Work Ability in Adults With Congenital Heart Disease and Implications for Clinical Practice
- 25 April 2020
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 36 (8) , 1567-1573
Moving beyond two-dimensional screens to interactive three-dimensional visualization in congenital heart disease
Beginning with the discovery of X-rays to the development of three-dimensional (3D) imaging, improvements in acquisition, post-processing, and visualization have provided clinicians with detailed information for increasingly accurate medical diagnosis and clinical management. This paper highlights advances in imaging technologies for congenital heart disease (CHD), medical adoption, and future developments required to improve pre-procedural and intra-procedural guidance.
- 25 April 2020
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 36 (8) , 1567-1573
Moving beyond two-dimensional screens to interactive three-dimensional visualization in congenital heart disease
Beginning with the discovery of X-rays to the development of three-dimensional (3D) imaging, improvements in acquisition, post-processing, and visualization have provided clinicians with detailed information for increasingly accurate medical diagnosis and clinical management. This paper highlights advances in imaging technologies for congenital heart disease (CHD), medical adoption, and future developments required to improve pre-procedural and intra-procedural guidance.
- 21 November 2019
- Published by Springer Nature in SN Comprehensive Clinical Medicine
- Vol. 1 (12) , 996-1000
Rapid Prototyping and Image Fusion Guidance for Transcatheter Closure of Superior Sinus Venosus Atrial Septal Defect
- 21 November 2019
- Published by Springer Nature in SN Comprehensive Clinical Medicine
- Vol. 1 (12) , 996-1000
Rapid Prototyping and Image Fusion Guidance for Transcatheter Closure of Superior Sinus Venosus Atrial Septal Defect
- 30 September 2019
- Published by Wiley in Pediatrics International
- Vol. 61 (11) , 1071-1080
Trends in the off‐label use of β‐blockers in pediatric patients
The use of US Food and Drug Administration (FDA)‐approved drugs for the treatment of an unapproved indication or in an unapproved age group, or at doses or route of administration not indicated on the label is known as off‐label use. Off‐label use may be beneficial in circumstances when the standard‐of‐care treatment has failed, and/or no other FDA‐approved medications are available for a particular condition. In pediatric patients, off‐label use may increase the risk of adverse events as pharmacokinetic and pharmacodynamic data are limited in children. Approximately 73% of off‐label drugs currently prescribed for various conditions do not have sufficient scientific evidence for safety and efficacy. For example, β‐blockers are a class of drugs with FDA‐approval for very few indications in pediatrics but are commonly used for various off‐label indications. Interestingly, the proportion of off‐label use of β‐blockers in adults is at about 52% (66.2 million) of the total number of β‐blockers prescribed. The frequency of off‐label use of β‐blockers in children is also high with limited data on the indications as well as safety and efficacy. We present trends in off‐label use of β‐blockers in children to discuss drug safety and efficacy and include recommendations for pediatric providers.
- 30 September 2019
- Published by Wiley in Pediatrics International
- Vol. 61 (11) , 1071-1080
Trends in the off‐label use of β‐blockers in pediatric patients
The use of US Food and Drug Administration (FDA)‐approved drugs for the treatment of an unapproved indication or in an unapproved age group, or at doses or route of administration not indicated on the label is known as off‐label use. Off‐label use may be beneficial in circumstances when the standard‐of‐care treatment has failed, and/or no other FDA‐approved medications are available for a particular condition. In pediatric patients, off‐label use may increase the risk of adverse events as pharmacokinetic and pharmacodynamic data are limited in children. Approximately 73% of off‐label drugs currently prescribed for various conditions do not have sufficient scientific evidence for safety and efficacy. For example, β‐blockers are a class of drugs with FDA‐approval for very few indications in pediatrics but are commonly used for various off‐label indications. Interestingly, the proportion of off‐label use of β‐blockers in adults is at about 52% (66.2 million) of the total number of β‐blockers prescribed. The frequency of off‐label use of β‐blockers in children is also high with limited data on the indications as well as safety and efficacy. We present trends in off‐label use of β‐blockers in children to discuss drug safety and efficacy and include recommendations for pediatric providers.
- 26 August 2019
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 34 (11) , 1363-1369
Three‐dimensional printing for surgical planning in complex congenital heart disease
Surgical management of complex congenital heart disease (CHD) is challenging. Three‐dimensional (3D) printing can improve multidisciplinary team decision‐making, patient and family understanding, and education of medical professionals. We describe 3D printing for surgical management of five patients with complex CHD. The anatomical details of the 3D printed models were instrumental in planning surgical techniques especially in determining between single ventricle, 1.5 ventricle, and biventricular repair.
- 26 August 2019
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 34 (11) , 1363-1369
Three‐dimensional printing for surgical planning in complex congenital heart disease
Surgical management of complex congenital heart disease (CHD) is challenging. Three‐dimensional (3D) printing can improve multidisciplinary team decision‐making, patient and family understanding, and education of medical professionals. We describe 3D printing for surgical management of five patients with complex CHD. The anatomical details of the 3D printed models were instrumental in planning surgical techniques especially in determining between single ventricle, 1.5 ventricle, and biventricular repair.
- 1 May 2019
- Published by Elsevier in International Journal of Cardiology
- Vol. 282, 44
Subclinical atherosclerosis in patients with cyanotic congenital heart disease
- 1 May 2019
- Published by Elsevier in International Journal of Cardiology
- Vol. 282, 44
Subclinical atherosclerosis in patients with cyanotic congenital heart disease
- 1 March 2019
- Published by Pulmonary Hypertension Association in Advances in Pulmonary Hypertension
- Vol. 18 (1) , 4-9
Atrial Septal Defect–Associated Pulmonary Hypertension: Outcomes of Closure With a Fenestrated Device
Article Citation: Vishal Kaley, Nagib Dahdah, Amal El-Sisi, Jochen Grohmann, Eric Rosenthal, Matthew Jones, Gareth Morgan, Nicholas Hayes, Ashish Shah, Cemsit Karakurt, Masood Sadiq, Matthias Sigler, Hans Figulla, Michael Becker, Nikolaus Haas, Eustaquio Onorato, Angel Puentes Rico, Supaporn Roymanee, Anselm Uebing, Walter Wiebe, Bennett Samuel, Ziyad Hijazi, and Joseph Vettukattil (2019) Atrial Septal Defect–Associated Pulmonary Hypertension: Outcomes of Closure With a Fenestrated Device. Advances in Pulmonary Hypertension: 2019, Vol. 18, No. 1, pp. 4-9. https://doi.org/10.21693/1933-088X-18.1.4
- 1 March 2019
- Published by Pulmonary Hypertension Association in Advances in Pulmonary Hypertension
- Vol. 18 (1) , 4-9
Atrial Septal Defect–Associated Pulmonary Hypertension: Outcomes of Closure With a Fenestrated Device
Article Citation: Vishal Kaley, Nagib Dahdah, Amal El-Sisi, Jochen Grohmann, Eric Rosenthal, Matthew Jones, Gareth Morgan, Nicholas Hayes, Ashish Shah, Cemsit Karakurt, Masood Sadiq, Matthias Sigler, Hans Figulla, Michael Becker, Nikolaus Haas, Eustaquio Onorato, Angel Puentes Rico, Supaporn Roymanee, Anselm Uebing, Walter Wiebe, Bennett Samuel, Ziyad Hijazi, and Joseph Vettukattil (2019) Atrial Septal Defect–Associated Pulmonary Hypertension: Outcomes of Closure With a Fenestrated Device. Advances in Pulmonary Hypertension: 2019, Vol. 18, No. 1, pp. 4-9. https://doi.org/10.21693/1933-088X-18.1.4
- 3 January 2019
- Published by Tech Science Press in Congenital Heart Disease
- Vol. 14 (3) , 356-361
Electronic health record associated stress: A survey study of adult congenital heart disease specialists
Background Physician burnout has many undesirable consequences, including negative impact on patient care delivery and physician career satisfaction. Electronic health records (EHRs) may exacerbate burnout by increasing physician workload. Objective To determine burnout in adult congenital heart disease (ACHD) specialists by assessing stress associated with EHRs. Design Electronic survey study of ACHD providers. Setting Canada and United States. Participants Three hundred eighty‐three ACHD specialists listed on the Adult Congenital Heart Association directory between February and April 2017. Outcome Measures Burnout was measured using the Maslach Burnout Inventory (MBI) to understand factors contributing to work life and EHR satisfaction. Chi‐square and Wilcoxon Rank Sum tests were used for statistical analysis. Results Of the 383 invited participants, 110 (28.7%) completed surveys with the majority (n = 88, 80.7%) reporting from an academic medical center. Burnout was defined as high scores on the emotional exhaustion and/or depersonalization MBI subscales. When comparing the 40% (n = 44) that met criteria for burnout with those that did not, there was strong disagreement that a reasonable amount of time is spent on clerical tasks related to direct (P = .0043) or indirect (P = .0004) patient care. There was strong disagreement that EHRs increased efficiency (P = .006) or the patient portal improved patient care (P = .0215). Finally, physicians who met criteria for burnout had lower personal accomplishment scores (P = .0355). Conclusions Our results suggest time spent on EHRs creates clerical burden exacerbating ACHD physician burnout. The high levels of emotional exhaustion may decrease quality of ACHD care by directing focus away from physician‐patient interaction. Health care systems must develop best practice for EHR design and implementation to optimize patient advocacy and care, and decrease physician burnout.
- 3 January 2019
- Published by Tech Science Press in Congenital Heart Disease
- Vol. 14 (3) , 356-361
Electronic health record associated stress: A survey study of adult congenital heart disease specialists
Background Physician burnout has many undesirable consequences, including negative impact on patient care delivery and physician career satisfaction. Electronic health records (EHRs) may exacerbate burnout by increasing physician workload. Objective To determine burnout in adult congenital heart disease (ACHD) specialists by assessing stress associated with EHRs. Design Electronic survey study of ACHD providers. Setting Canada and United States. Participants Three hundred eighty‐three ACHD specialists listed on the Adult Congenital Heart Association directory between February and April 2017. Outcome Measures Burnout was measured using the Maslach Burnout Inventory (MBI) to understand factors contributing to work life and EHR satisfaction. Chi‐square and Wilcoxon Rank Sum tests were used for statistical analysis. Results Of the 383 invited participants, 110 (28.7%) completed surveys with the majority (n = 88, 80.7%) reporting from an academic medical center. Burnout was defined as high scores on the emotional exhaustion and/or depersonalization MBI subscales. When comparing the 40% (n = 44) that met criteria for burnout with those that did not, there was strong disagreement that a reasonable amount of time is spent on clerical tasks related to direct (P = .0043) or indirect (P = .0004) patient care. There was strong disagreement that EHRs increased efficiency (P = .006) or the patient portal improved patient care (P = .0215). Finally, physicians who met criteria for burnout had lower personal accomplishment scores (P = .0355). Conclusions Our results suggest time spent on EHRs creates clerical burden exacerbating ACHD physician burnout. The high levels of emotional exhaustion may decrease quality of ACHD care by directing focus away from physician‐patient interaction. Health care systems must develop best practice for EHR design and implementation to optimize patient advocacy and care, and decrease physician burnout.