CCChiao-Chen Chen

Chiao-Chen Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Chiao-Chen Chen has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Transfer-Free Conformal Graphene Coating on Pyramidal Microstructures Decorated with Silver Nanoparticles for Superior Raman Signal Enhancement

    by Cheuk Yui Lai, Yu-Xuan Lin, En-Jing Lin, Ching-Chih Lin, Chiao-Chen Chen

    Graphene, a two-dimensional nanomaterial with excellent physicochemical properties, has considerable potential to functionalize surfaces for diverse applications. However, reliable methods for preparing uniform conformal graphene on complex surfaces are still limited. In this study, we develop a practical strategy for the direct growth of conformal graphene coatings on silicon substrates textured with randomly distributed micropyramidal structures. The produced transfer-free graphene exhibits high uniformity (monolayer content ∼95%), low defect density, and excellent conformality, even across high-curvature features, such as micropyramid apexes. The graphene films not only faithfully replicate the underlying microstructures but also contribute to advantageous surface properties, including strong fluorescence quenching, excellent chemical stability, enhanced molecular adsorption, and improved charge-transfer interactions. All these properties are crucial for effective surface-enhanced Raman scattering (SERS). This graphene-coated pyramidal substrate enabled reproducible and stable SERS detection of rhodamine 6G (R6G), exhibiting high sensitivity with a detection limit of ∼10-6 M, excellent long-term stability over 30 days, and low spatial signal variation of ∼10% at the millimeter scale. By further decorating the graphene-coated pyramidal substrate with silver nanoparticles, the detection limit was improved to 5.5 × 10-9 M for R6G with a high analytical enhancement factor of 1.08 × 105. This enhanced performance arose from the synergistic interplay between the light-trapping capability of the microstructured surface, the chemical enhancement caused by the graphene interface, and the electromagnetic amplification provided by the plasmonic nanoparticles. These findings offer valuable insights into the design of high-performance SERS platforms. This study also presents a practical method for the direct synthesis of conformal graphene for surface functionalization that is promising for a wide range of applications in sensing, optoelectronics, and catalysis.


  • Open Access

    Tailoring the Morphology of Cu2O Microcrystals in Cu2O/rGO Composites for Achieving Enhanced Supercapacitor Performance

    by Hsin-Lin Hsieh, Yi-Hsiu Wang, Chun-Yu Tsai, Chao-Hsuan Yang, En-Jing Lin, Chiao-Chen Chen


  • Laminar Flow-Assisted Metal Etching for the Preparation of High-Quality Transfer-Free Graphene

    by Fang-Chi Ding, Cheng-Yu Dai, Chun-Lung Yao, Cheuk Yui Lai, Chiao-Chen Chen


  • Lipid-Modified Graphene-Transistor Biosensor for Monitoring Amyloid-β Aggregation

    by Chia-Jung Kuo, Hsu-Cheng Chiang, Chi-Ang Tseng, Chin-Fu Chang, Rajesh Kumar Ulaganathan, Tzu-Ting Ling, Yu-Jen Chang, Chiao-Chen Chen, Yun-Ru Chen, Yit-Tsong Chen

    A graphene field-effect transistor (G-FET) with the spacious planar graphene surface can provide a large-area interface with cell membranes to serve as a platform for the study of cell membrane-related protein interactions. In this study, a G-FET device paved with a supported lipid bilayer (referred to as SLB/G-FET) was first used to monitor the catalytic hydrolysis of the SLB by phospholipase D. With excellent detection sensitivity, this G-FET was also modified with a ganglioside GM1-enriched SLB (GM1-SLB/G-FET) to detect cholera toxin B. Finally, the GM1-SLB/G-FET was employed to monitor amyloid-beta 40 (Aβ40) aggregation. In the early nucleation stage of Aβ40 aggregation, while no fluorescence was detectable with traditional thioflavin T (ThT) assay, the prominent electrical signals probed by GM1-SLB/G-FET demonstrate that the G-FET detection is more sensitive than the ThT assay. The comprehensive kinetic information during the Aβ40 aggregation could be collected with a GM1-SLB/G-FET, especially covering the kinetics involved in the early stage of Aβ40 aggregation. These experimental results suggest that SLB/G-FETs hold great potential as a powerful biomimetic sensor for versatile investigations of membrane-related protein functions and interaction kinetics.


  • One-Step Synthesis of Antioxidative Graphene-Wrapped Copper Nanoparticles on Flexible Substrates for Electronic and Electrocatalytic Applications

    by Chi-Ang Tseng, Chiao-Chen Chen, Rajesh Kumar Ulaganathan, Chuan-Pei Lee, Hsu-Cheng Chiang, Chin-Fu Chang, Yit-Tsong Chen

    In this study, we report a novel, one-step synthesis method to fabricate multilayer graphene (MLG)-wrapped copper nanoparticles (CuNPs) directly on various substrates (e.g., polyimide film (PI), carbon cloth (CC), or Si wafer (Si)). The electrical resistivities of the pristine MLG-CuNPs/PI and MLG-CuNPs/Si were measured 1.7 × 10–6 and 1.4 × 10–6 Ω·m, respectively, of which both values are ∼100-fold lower than earlier reports. The MLG shell could remarkably prevent the Cu nanocore from serious damages after MLG-CuNPs being exposed to various harsh conditions. Both MLG-CuNPs/PI and MLG-CuNPs/Si retained almost their conductivities after ambient annealing at 150 °C. Furthermore, the flexible MLG-CuNPs/PI exhibits excellent mechanical durability after 1000 bending cycles. We also demonstrate that the MLG-CuNPs/PI can be used as promising source-drain electrodes in fabricating flexible graphene-based field-effect transistor (G-FET) devices. Finally, the MLG-CuNPs/CC was shown to possess high performance and durability toward hydrogen evolution reaction (HER).


  • Growth of Large-Area Graphene Single Crystals in Confined Reaction Space with Diffusion-Driven Chemical Vapor Deposition

    by Chiao-Chen Chen, Chia-Jung Kuo, Chun-Da Liao, Chin-Fu Chang, Chi-Ang Tseng, Chia-Rung Liu, Yit-Tsong Chen


  • Potentiometric-Scanning Ion Conductance Microscopy

    by Yi Zhou, Chiao-Chen Chen, Anna E. Weber, Lushan Zhou, Lane A. Baker

    We detail the operation mechanism and instrumental limitations for potentiometric-scanning ion conductance microscopy (P-SICM). P-SICM makes use of a dual-barrel probe, where probe position is controlled by the current measured in one barrel and the potential is measured in a second barrel. Here we determine the interaction of these two barrels and resultant effects in quantitation of signals. Effects due to the size difference in pipet tip opening are examined and compared to model calculations. These results provide a basis for quantitation and image interpretation for P-SICM.


  • Advances in nanowire transistors for biological analysis and cellular investigation

    by Bor-Ran Li, Chiao-Chen Chen, U. Rajesh Kumar, Yit-Tsong Chen

    Electrical biosensors based on silicon nanowire field-effect transistors (SiNW-FETs) have attracted enormous interest in the biosensing field. SiNW-FETs have proven to be significant and efficient in detecting diverse biomolecular species with the advantages of high probing sensitivity, target selectivity, real-time recording and label-free detection. In recent years, significant advances in biosensors have been achieved, particularly for cellular investigation and biomedical diagnosis. In this critical review, we will report on the latest developments in biosensing with SiNW-FETs and discuss recent advancements in the innovative designs of SiNW-FET devices. This critical review introduces the basic instrumental setup and working principle of SiNW-FETs. Technical approaches that attempted to enhance the detection sensitivity and target selectivity of SiNW-FET sensors are discussed. In terms of applications, we review the recent achievements with SiNW-FET biosensors for the investigations of protein–protein interaction, DNA/RNA/PNA hybridization, virus detection, cellular recording, biological kinetics, and clinical diagnosis. In addition, the novel architecture designs of the SiNW-FET devices are highlighted in studies of live neuron cells, electrophysiological measurements and other signal transduction pathways. Despite these remarkable achievements, certain improvements remain necessary in the device performance and clinical applications of FET-based biosensors; thus, several prospects about the future development of nanowire transistor-based instruments for biosensing employments are discussed at the end of this review.


  • Open Access

    Potentiometric-scanning ion conductance microscopy for measurement at tight junctions

    by Yi Zhou, Chiao-Chen Chen, Anna E Weber, Lushan Zhou, Lane A Baker, Jianghui Hou

    Scanning Ion Conductance Microscopy (SICM) has been developed originally for high-resolution imaging of topographic features. Recently, we have described a hybrid voltage scanning mode of SICM, termed Potentiometric-SICM (P-SICM) for recording transmembrane ionic conductance at specific nanostructures of synthetic and biological interfaces. With this technique, paracellular conductance through tight junctions – a subcellular structure that has been difficult to interrogate previously – has been realized. P-SICM utilizes a dual-barrel pipet to differentiate paracellular from transcellular transport processes with nanoscale spatial resolution. The unique combination of voltage scanning and topographic imaging enables P-SICM to capture paracellular conductance within a nominal radius of several hundred nanometers. This review summarizes recent advances in paracellular conductance recording with an emphasis on the P-SICM based approach, which is applied to detect claudin-2 mediated permeability changes at the tight junction.