Milan Honner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Milan Honner has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Michal Švantner
University of West Bohemia
15 shared publications - Jiri Martan
New Technologies—Research Centre, University of West Bohemia, Univerzitní 8, 301 00 Plzeň, Czech Republic
8 shared publications - Lukáš Muzika
New Technologies-Research Centre, University of West Bohemia, 30100 Pilsen, Czech Republic
7 shared publications - Zdenek Vesely
New Technologies - Research Centre, University of West Bohemia, Czech Republic
6 shared publications - Denys Moskal
New Technologies—Research Centre, University of West Bohemia in Pilsen, Univerzitni 8, 301 00 Pilsen, Czech Republic
5 shared publications - Jiří Skála
New Technologies-Research Centre, University of West Bohemia, 301 00 Pilsen, Czech Republic
5 shared publications
Latest Publications
- 12 August 2026
- Published by Springer Nature
- p. 500-515
Application for Parametric Image Evaluation and Comparison
- 12 August 2026
- Published by Springer Nature
- p. 500-515
Application for Parametric Image Evaluation and Comparison
- 2 August 2026
- Published by Springer Nature
- p. 672-689
Adapting AI-Based Medical Imaging Techniques for Forensic Gunshot Residue Analysis Using Infrared Thermography
- 2 August 2026
- Published by Springer Nature
- p. 672-689
Adapting AI-Based Medical Imaging Techniques for Forensic Gunshot Residue Analysis Using Infrared Thermography
- Open Access
- 27 May 2026
- Published by Taylor & Francis in Quantitative InfraRed Thermography Journal
- p. 1-16
Explainable AI for shooting distance estimation from gunshot residue (GSR) via flash thermography
- 27 May 2026
- Published by Taylor & Francis in Quantitative InfraRed Thermography Journal
- p. 1-16
Open AccessExplainable AI for shooting distance estimation from gunshot residue (GSR) via flash thermography
- Open Access
- 25 May 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (6) , 653
Fast Thermal Monitoring of Pulsed Laser Cleaning Processes
Current manual laser cleaning methods often require highly skilled operators to achieve fast and reliable cleaning. This study investigated the feasibility of measuring thermal processes during laser metal cleaning to support the development of an automated and intelligent laser cleaning system. The measurement system was based on fast infrared (IR) diagnostics and used a field programmable gate array (FPGA) for fast signal analysis. Experiments were conducted on steel substrates covered with paint, scale, or corrosion. Thermal response in real-time for every laser pulse was monitored. Paints showed no solidification plateau, while steel exhibited a clear plateau above the ablation threshold. The scaled surface showed longer time intervals and higher heat accumulation. A histogram of time intervals enabled statistical analysis of the process. Time-resolved temperature values revealed hidden processes. These findings demonstrated the potential of IR thermal diagnostics for evaluating surface conditions and providing real-time data to optimise, monitor, and control laser cleaning processes.
- 25 May 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (6) , 653
Open AccessFast Thermal Monitoring of Pulsed Laser Cleaning Processes
Current manual laser cleaning methods often require highly skilled operators to achieve fast and reliable cleaning. This study investigated the feasibility of measuring thermal processes during laser metal cleaning to support the development of an automated and intelligent laser cleaning system. The measurement system was based on fast infrared (IR) diagnostics and used a field programmable gate array (FPGA) for fast signal analysis. Experiments were conducted on steel substrates covered with paint, scale, or corrosion. Thermal response in real-time for every laser pulse was monitored. Paints showed no solidification plateau, while steel exhibited a clear plateau above the ablation threshold. The scaled surface showed longer time intervals and higher heat accumulation. A histogram of time intervals enabled statistical analysis of the process. Time-resolved temperature values revealed hidden processes. These findings demonstrated the potential of IR thermal diagnostics for evaluating surface conditions and providing real-time data to optimise, monitor, and control laser cleaning processes.
- Open Access
- 12 September 2025
- Published by MDPI AG in Proceedings
- Vol. 129 (1) , 62
Quantitative Analysis of Flash-Pulse Thermographic Detection of Gunshot Residue
This study addresses the detection of gunshot residue (GSR) around a bullet hole, which is one of the key forensic procedures for estimating the firing distance. GSR was inspected using flash-pulse thermography (FPT) with Kurtosis statistical processing. The result of such an inspection is a pattern composed of numerous small indications distributed around the hole, attributed to gunshot residue particles. The number and spatial distribution of these indications depend on the firing distance. Analyzing such results based on individual indications is impractical, as the pattern must be evaluated as a whole. Therefore, quantifying the overall result can significantly improve the analysis of the firing distance estimation. This study presents a quantification procedure based on threshold-based mass-marking of indications and evaluation of several statistical characteristics. The correlation between these characteristics and firing distance is then analyzed. A strong but distinctly nonlinear correlation was found between the firing distance and some simple quantitative characteristics, such as the total number of indications. However, the study shows that some derived characteristics, such as the contrast between marked areas and background, exhibit a near-linear correlation. These parameters are, therefore, promising for firing distance analysis based on FPT inspection of GSR on through-shot targets.
- 12 September 2025
- Published by MDPI AG in Proceedings
- Vol. 129 (1) , 62
Open AccessQuantitative Analysis of Flash-Pulse Thermographic Detection of Gunshot Residue
This study addresses the detection of gunshot residue (GSR) around a bullet hole, which is one of the key forensic procedures for estimating the firing distance. GSR was inspected using flash-pulse thermography (FPT) with Kurtosis statistical processing. The result of such an inspection is a pattern composed of numerous small indications distributed around the hole, attributed to gunshot residue particles. The number and spatial distribution of these indications depend on the firing distance. Analyzing such results based on individual indications is impractical, as the pattern must be evaluated as a whole. Therefore, quantifying the overall result can significantly improve the analysis of the firing distance estimation. This study presents a quantification procedure based on threshold-based mass-marking of indications and evaluation of several statistical characteristics. The correlation between these characteristics and firing distance is then analyzed. A strong but distinctly nonlinear correlation was found between the firing distance and some simple quantitative characteristics, such as the total number of indications. However, the study shows that some derived characteristics, such as the contrast between marked areas and background, exhibit a near-linear correlation. These parameters are, therefore, promising for firing distance analysis based on FPT inspection of GSR on through-shot targets.
- Open Access
- 14 December 2024
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 239
Thermo-electron accumulation in light and heavy water during MHz-burst laser ablation
- 14 December 2024
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 239
Open AccessThermo-electron accumulation in light and heavy water during MHz-burst laser ablation
- 28 February 2024
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 200
Analysis of laser surface absorptivity modification for selective laser hardening
- 28 February 2024
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 200
Analysis of laser surface absorptivity modification for selective laser hardening
- Open Access
- 30 October 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 51 (1) , 17
Compact Thermographic Device with Built-in Active Reference Element for Increased Measurement Accuracy
Many common thermographic cameras have quite good sensitivity (0.05 °C or better) but limited accuracy, often about ±2 °C. This is not sufficient for quantitative measurements such as human body temperature diagnostics, where an accuracy of 0.3 °C is assumed. A thermographic device with a built-in active reference element for enhanced precision measurement was developed for these purposes. It was adapted for human body temperature diagnostics using face temperature measurements. It is based on a micro-bolometers detector and the reference element is heated to a temperature of 37 °C, which is mostly assumed as decisive for an increased temperature indication. As the reference element is embedded into the device housing, the use of the device can be very flexible. The performed human temperature measurement experiments showed that the accuracy of the introduced device is comparable with the thermographic measurements obtained using an external black body, which is often used for these applications.
- 30 October 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 51 (1) , 17
Open AccessCompact Thermographic Device with Built-in Active Reference Element for Increased Measurement Accuracy
Many common thermographic cameras have quite good sensitivity (0.05 °C or better) but limited accuracy, often about ±2 °C. This is not sufficient for quantitative measurements such as human body temperature diagnostics, where an accuracy of 0.3 °C is assumed. A thermographic device with a built-in active reference element for enhanced precision measurement was developed for these purposes. It was adapted for human body temperature diagnostics using face temperature measurements. It is based on a micro-bolometers detector and the reference element is heated to a temperature of 37 °C, which is mostly assumed as decisive for an increased temperature indication. As the reference element is embedded into the device housing, the use of the device can be very flexible. The performed human temperature measurement experiments showed that the accuracy of the introduced device is comparable with the thermographic measurements obtained using an external black body, which is often used for these applications.
- Open Access
- 30 October 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 51 (1) , 16
Tracking Long-Term Temperature Anomalies with Person Identification Using Thermal Cameras: An Initial Step towards Disease Recognition
An outbreak of infectious diseases has highlighted the importance of the early detection and prevention of high temperatures or fevers, which are some of the main symptoms of many diseases. Thermal cameras have become a promising tool for the detection of fever due to their non-invasive, non-contact and rapidly inspecting nature. By using person identification to analyze temperature data from the corner of the eye (inner canthus), the temperature of individuals can be tracked over time. This could provide information not only about their current temperature but also about long-term temperature anomalies, and therefore can urge people to visit a doctor. This paper is intended as an initial study for the long-term temperature measurement of individuals. The preliminary results show the feasibility of such approach. In the future, a similar procedure is to be used for the detection and recognition of individual diseases.
- 30 October 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 51 (1) , 16
Open AccessTracking Long-Term Temperature Anomalies with Person Identification Using Thermal Cameras: An Initial Step towards Disease Recognition
An outbreak of infectious diseases has highlighted the importance of the early detection and prevention of high temperatures or fevers, which are some of the main symptoms of many diseases. Thermal cameras have become a promising tool for the detection of fever due to their non-invasive, non-contact and rapidly inspecting nature. By using person identification to analyze temperature data from the corner of the eye (inner canthus), the temperature of individuals can be tracked over time. This could provide information not only about their current temperature but also about long-term temperature anomalies, and therefore can urge people to visit a doctor. This paper is intended as an initial study for the long-term temperature measurement of individuals. The preliminary results show the feasibility of such approach. In the future, a similar procedure is to be used for the detection and recognition of individual diseases.
- Open Access
- 12 June 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (6) , 1241
Scanning Strategies in Laser Surface Texturing: A Review
Laser surface texturing (LST) is one of the most promising technologies for controllable surface structuring and the acquisition of specific physical surface properties needed in functional surfaces. The quality and processing rate of the laser surface texturing strongly depend on the correct choice of a scanning strategy. In this paper, a comparative review of the classical and recently developed scanning strategies of laser surface texturing is presented. The main attention is paid to maximal processing rate, precision and existing physical limitations. Possible ways of further development of the laser scanning strategies are proposed.
- 12 June 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (6) , 1241
Open AccessScanning Strategies in Laser Surface Texturing: A Review
Laser surface texturing (LST) is one of the most promising technologies for controllable surface structuring and the acquisition of specific physical surface properties needed in functional surfaces. The quality and processing rate of the laser surface texturing strongly depend on the correct choice of a scanning strategy. In this paper, a comparative review of the classical and recently developed scanning strategies of laser surface texturing is presented. The main attention is paid to maximal processing rate, precision and existing physical limitations. Possible ways of further development of the laser scanning strategies are proposed.