Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Qing Chen has a total of 41 co-authors. Here are the top co-authors by number of shared publications:

  • Ning Shao

    Key Laboratory of Power System Intelligent Dispatch and Control of Ministry of Education, Shandong University, Jinan 250061, China

    6 shared publications
  • Wei Ding

    Key Laboratory of Power System Intelligent Dispatch and Control of Ministry of Education, Shandong University, Jinan 250061, China

    6 shared publications
  • Dan Xie

    Key Laboratory of Power System Intelligent Dispatch and Control of Ministry of Education, Shandong University, Jinan 250061, China

    4 shared publications
  • Ye Sun

    Key Laboratory of Power System Intelligent Dispatch and Control of Ministry of Education, Shandong University, Jinan 250061, China

    4 shared publications
  • Yuzhan Dong

    Key Laboratory of Power System Intelligent Dispatch and Control of Ministry of Education, Shandong University, Jinan 250061, China

    4 shared publications
  • Kongming Sun

    State Grid Shandong Electric Power Research Institute, Jinan 250003, China

    3 shared publications

Latest Publications

  • Open Access

    Improved Temporal Fuzzy Reasoning Spiking Neural P Systems for Power System Fault Diagnosis

    by Ning Shao, Qing Chen, Dan Xie, Ye Sun, Chengao Yu

    Fuzzy and temporal reasoning can effectively improve the accuracy of fault diagnosis methods. However, there are challenges in practical applications, such as missing alarm messages, temporal reasoning with complex calculations, and complex modeling processes. Therefore, this study proposes an improved temporal fuzzy reasoning spiking neural P (ITFRSNP) system for power system fault diagnosis. First, the ITFRSNP system and its reasoning method are proposed to perform association reasoning between confidence degrees and temporal constraints. Second, a general fault diagnosis model and process are developed based on the ITFRSNP system to diagnose various faulty components and simplify the modeling process. In addition, a search method is provided for identifying suspected faulty components, considering the missing alarm message of the circuit breaker. Simulation results of fault cases demonstrate that the proposed method exhibits high accuracy and fault tolerance. It can precisely identify faulty components despite incorrect operations or inaccurate alarm messages of protective relays and circuit breakers. Moreover, the search method effectively narrows down the diagnostic scope without missing suspected faulty components in scenarios where alarms from boundary circuit breakers are missing, thereby enhancing the fault diagnosis efficiency. The fault diagnosis model features a straightforward structure and reasoning process with minimal computational complexity, making it suitable for real-time diagnosis of complex faults within power systems.


  • Open Access

    Fault Tracing Method for Relay Protection System–Circuit Breaker Based on Improved Random Forest

    by Ning Shao, Qing Chen, Chengao Yu, Dan Xie, Ye Sun

    The incorrect operation of protective relays and circuit breakers will significantly compromise the safety and stability of power systems. To promptly detect the faults of the relay protection system and the circuit breakers in time and to ensure the operational reliability of these protective devices, this paper proposes a fault tracing method for a relay protection system–circuit breaker based on improved Random Forest. Firstly, an analysis is conducted to identify the causes of incorrect operation of the protective relay and the circuit breaker. The fault types and corresponding alarm messages for the relay protection system and the circuit breaker are categorized, and the alarm feature set is constructed. Then, the Random Forest is improved and trained to develop the fault tracking model. Finally, the operation evaluation process is developed to determine the incorrect operations of the protective relay and the circuit breaker, and the fault tracking model and fault tracking process are then employed to locate the faults of the relay protection system and the circuit breaker. The experimental results demonstrate the method’s capability to accurately track faults in the relay protection system and the circuit breaker, thereby assisting operation and maintenance personnel in troubleshooting and highlighting its promising practical potential.


  • Open Access

    A Wide-Area Measurement System-Based Load Encroachment Identification Method Applicable to Power Systems with High Wind Power Penetration

    by Dan Xie, Qing Chen, Ye Sun, Ning Shao, Yuzhan Dong, Wei Ding

    One of the main factors in triggering cascading outages is the unexpected tripping of backup protection caused by load encroachment (LE). Hence, LE should be identified quickly to avoid unexpected tripping. This paper proposes a fast LE identification method based on the wide-area measurement system (WAMS), applicable to transmission grids with high wind power penetration. Firstly, based on the improved shortest path algorithm, the method searches for critical lines greatly affected by the LE to determine the collected range of wide-area information. Then, by analyzing the hidden dangers of the existing calculation method for the active power estimation value (APEV) in the power system with wind farms, a fast calculation method of the APEV based on the WAMS is proposed to ensure that the existing LE identification criterion is still applicable in the high-penetration system of wind power. Finally, based on the PSASP platform, the wind farm model is integrated into the IEEE 39-bus New England system for simulation. The simulation results show that the method proposed in this paper can quickly search for the critical line set (CLS) and accurately identify the LE under high wind power penetration, effectively avoiding the unexpected tripping of backup protection and preventing cascading outages.

  • Open Access

    Novel Faulted-Section Location Method for Active Distribution Networks of New-Type Power Systems

    by Ye Sun, Qing Chen, Dan Xie, Ning Shao, Wei Ding, Yuzhan Dong

    This paper puts forward a fault location method combining the improved matrix algorithm and the genetic tabu algorithm based on multi-source information in view of the limitation of existing fault location methods in active distribution networks, such as long-time consumption, low accuracy, and low tolerance performance. Firstly, the fault region location method is proposed to simplify the active distribution network model and reduce the matrix calculation dimension. Secondly, the improved matrix algorithm is proposed to locate the fault section, and a positioning result verification method is proposed to improve the tolerance performance. Finally, the genetic tabu algorithm is proposed to optimize suspicious fault sections when the verification is incorrect and obtain the positioning result. The simulation results show that the fault location method proposed in this paper locates faster and performs better in both accuracy and tolerance in different fault conditions than others.


  • Power System Fault Diagnosis Method Based on Intuitionistic Fuzzy Sets and Incidence Matrices

    by Ning Shao, Qing Chen, Yuzhan Dong, Wei Ding, Lei Wang

    Fault diagnosis is critical to ensuring the stable and reliable operation of power systems. Currently, power system fault diagnosis faces two challenges. One is that fault diagnosis methods do not fully consider power system scale and topology changes. The other is that the uncertainty of alarm information yields inaccurate fault diagnosis results. To address the above problems, this article proposes a fault diagnosis method based on intuitionistic fuzzy sets and incidence matrices. First, the fault area is searched, and its incidence matrices are constructed. Then, the intuitionistic fuzzy numbers are assigned to the incidence matrices using proposed assignment rules to form intuitionistic fuzzy incidence matrices while considering the missing alarm information. Finally, the fault diagnosis model based on intuitionistic fuzzy incidence matrices and its reasoning process are utilized to diagnose the fault area. The case studies illustrate that the proposed method has high accuracy and fault tolerance. The fault diagnosis model is independent of the power system scale and can adapt to topology changes. Moreover, the reasoning process is low-complexity and easy to implement. The proposed method is demonstrated to satisfy the demand for online fault diagnosis in large-scale power systems.


  • Open Access

    Fault Diagnosis Method of Intelligent Substation Protection System Based on Gradient Boosting Decision Tree

    by Wei Ding, Qing Chen, Yuzhan Dong, Ning Shao

    In order to improve the efficiency of the devices’ fault diagnosis of the protection systems of intelligent substation, a fault diagnosis method based on a gradient boosting decision tree (GBDT) was proposed. Using the integrated alarm information, the device self-checking information, the link information of generic object-oriented substation event (GOOSE) and sampled value (SV) and the sampling value information generated during the fault of the protection system, the fault feature information set is constructed. According to different fault characteristics, the protection system faults are classified into simple faults and complex faults to improve the diagnosis efficiency. Using GBDT training rules, a fault diagnosis model of protection system based on GBDT is established and fault diagnosis steps are given. This study takes a 110 kV intelligent substation in southern China as an example, to verify the effectiveness and accuracy of the proposed fault diagnosis method, and compared it with the existing methods in terms of the accuracy. The diagnostic accuracy in the case of false alarms and the case of multiple faults are verified. The results show that the method can meet the practical engineering application.


  • Open Access

    State Evaluation and Fault Prediction of Protection System Equipment Based on Digital Twin Technology

    by Yuzhan Dong, Qing Chen, Wei Ding, Ning Shao, Guanting Chen, Guanbin Li

    Digital twin technology aims to build a map of physical entities in virtual space, and simulate the real-time state and dynamic characteristics of physical devices through bi-directional interactive data flow. In order to guarantee the safe and stable operation of protection system equipment in intelligent substations and improve the efficiency of protection system operation and condition maintenance, this paper proposes a protection system state evaluation and fault prediction method based on digital twin technology. The architecture, application and operation control mode of digital twin technology in a real-time state analysis of a protection system are studied. The state evaluation model based on matter-element extension and the fault prediction model based on clustering algorithm are constructed. By analyzing the historical data of an intelligent station protection system in actual operation, a database that can be updated and corrected in real time is constructed. The effectiveness and accuracy of the state evaluation and fault prediction method are verified with actual cases, which can provide technical support for the operation and maintenance of the protection system.


  • Open Access

    A Power Grid Fault Diagnosis Method in the Case of Alarm Information Loss Based on the Top-k Skyline Query Algorithm

    by Lei Jin, Qing Chen, Jinjie Ji, Xiaotong Zhou

    After the failure of the power system, a large amount of alarm information will flood into the dispatching terminal instantly. At the same time, there are inevitable problems, such as the abnormal operation of the protection and the circuit breaker, the lack of alarm information, and so on. This kind of uncertainty problem brings great trouble to the fault diagnosis algorithm. As a data processing algorithm for an uncertain information set, Top-k Skyline query algorithm can eliminate the data points that do not meet the requirements in the information set, and then output the final K results in order. Based on this background, this paper proposes a power grid fault diagnosis method based on the Top-k Skyline query algorithm considering alarm information loss. Firstly, the fault area is determined by using the information of the electrical quantity and switching value. Then, backward reasoning Petri nets are established for the nodes in the fault area to form the data set of fault hypotheses. Then, the Top-k Skyline query algorithm is used to sort the hypotheses and choose the hypothesis with higher reliability. Finally, an IEEE 39-bus system example is given to verify the reliability of the proposed method.


  • Open Access

    Fault Diagnosis System of Power Grid Based on Multi-Data Sources

    by Jinjie Ji, Qing Chen, Lei Jin, Xiaotong Zhou, Wei Ding

    In order to complete the function of power grid fault diagnosis accurately, rapidly and comprehensively, the power grid fault diagnosis system based on multi-data sources is proposed. The integrated system uses accident-level information, warning-level information and fault recording documents and outputs a complete diagnosis and tracking report. According to the timeliness of three types of information transmission, the system is divided into three subsystems: real-time processing system, quasi-real-time processing system and batch processing system. The complete work is realized through the cooperation between them. While a real-time processing system completes fault diagnosis of elements, it also screens out incorrectly operating protections and circuit breakers and judges the loss of accident-level information. Quasi-real-time system outputs reasons for incorrect actions of protections and circuit breakers under the premise of considering partial warning-level information missing. The batch processing system corrects diagnosis results of the real-time processing system and outputs fault details, including fault phases, types, times and locations of faulty elements. The simulation results and test show that the system can meet actual engineering requirements in terms of execution efficiency and fault diagnosis and tracking effect. It can be used as a reference for self-healing and maintenance of power grids and has a preferable application value.


  • Open Access

    Fault Tracking Method for Relay Protection Devices

    by Qing Chen, Xiaotong Zhou, Mengxuan Sun, Xiaotong Zhang

    A method of fault tracking for relay protection devices is presented in this paper. Fault tracking means that after the failure of relay protection devices, the anomalies and warning information are obtained through data-mining technology, and then, the fault tracking algorithm is used to find the cause of failure. Let us take microcomputer protection as an example: Firstly, the common failure symptoms and the prior probability of failure causes can be collected through empirical field data. Then, the concept of an event set is proposed; thus, the causes set and the symptoms set of failure can be created. According to the causal relationship between the causes set of failure and symptoms set of failure, the reasoning chain and the corresponding Bayesian network model are built. Then, the probability of failure causes can be obtained through backward reasoning to continue the tracking analysis of failure causes for relay protection devices. Since the data used in modeling are all from statistics, this method has strong applicability and represents a simple and reliable method for the timely determination and elimination of failure in a power system.