Carlos Oliveira
Research Subjects
Carlos Oliveira has a total of 201 co-authors. Here are the top co-authors by number of shared publications:
J. Salgado
ITN-Instituto Tecnológico e Nuclear, Estrada Nacional, no. 10, 2686-953 Sacavém, Portugal
11 shared publications- Thomas A. Girard
University of Lisbon
9 shared publications D. Limagne
6 shared publicationsF. Giuliani
6 shared publicationsG. Waysand
6 shared publications- Luis Mota Ferreira
Centro de Ciências e Tecnologias Nucleares (C2TN), Instituto Superior Técnico (IST), Universidade de Lisboa, 2695-066 Bobadela, Portugal
6 shared publications
Latest Publications
- 1 July 2016
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 113, 47-52
Study of the response of an ORTEC GMX45 HPGe detector with a multi-radionuclide volume source using Monte Carlo simulations
- 1 July 2016
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 113, 47-52
Study of the response of an ORTEC GMX45 HPGe detector with a multi-radionuclide volume source using Monte Carlo simulations
- 13 May 2016
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 170 (1-4) , 136-140
COMPARISON METHODOLOGIES FOR CALIBRATION OFHp(10) PERSONAL DOSEMETERS USING ISO 4037 AND ISO 29661 STANDARDS
The calibration of electronic personal dosemeters at the Portuguese ionizing radiation metrology laboratory uses the standard IEC 61526 for calibration methodology. This standard describes the irradiation geometry for testing and indicates that the standard ISO 4037-1, 2, 3 and 4 should be used. The ISO 4037 establishes that the reference point of test is a point in the radiation monitor, known or established, and the calibration phantom should be placed on its back in order to simulate the trunk body. Recently, ISO published another standard, the ISO 29661, that changes the reference point from the radiation monitor to the front face of the calibration phantom. The aim of this work is to present the result of the comparison of these two methodologies on personal dosemeters from five different manufacturers. The work shows differences in the Hp(10) response up to 4% resulting from the two different reference point concepts.
- 13 May 2016
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 170 (1-4) , 136-140
COMPARISON METHODOLOGIES FOR CALIBRATION OFHp(10) PERSONAL DOSEMETERS USING ISO 4037 AND ISO 29661 STANDARDS
The calibration of electronic personal dosemeters at the Portuguese ionizing radiation metrology laboratory uses the standard IEC 61526 for calibration methodology. This standard describes the irradiation geometry for testing and indicates that the standard ISO 4037-1, 2, 3 and 4 should be used. The ISO 4037 establishes that the reference point of test is a point in the radiation monitor, known or established, and the calibration phantom should be placed on its back in order to simulate the trunk body. Recently, ISO published another standard, the ISO 29661, that changes the reference point from the radiation monitor to the front face of the calibration phantom. The aim of this work is to present the result of the comparison of these two methodologies on personal dosemeters from five different manufacturers. The work shows differences in the Hp(10) response up to 4% resulting from the two different reference point concepts.
- 21 April 2016
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 170 (1-4) , 127-131
CHARACTERIZATION OF AN ACTIVE DOSEMETER ACCORDING TO IEC 61526:2010
The active personal dosemeter, RaySafe i2, allows the measurement and record of Hp(10) in real time, every second, via wireless technology for real-time display on a portable computer and/or a local network. The system seems particularly attractive for individual monitoring at clinical facilities where high intensity and varying radiation fields may occur, as it enables the user to acknowledge and optimize the dose and dose rate values in real time for each procedure. Prior to its use, the system was characterized at the Metrology Laboratory of Ionizing Radiation of IST-LPSR aiming at the metrological characterization of the system in accordance with IEC 61526:2010 for metrological control purposes and to verify the technical specifications stated by the manufacturer.
- 21 April 2016
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 170 (1-4) , 127-131
CHARACTERIZATION OF AN ACTIVE DOSEMETER ACCORDING TO IEC 61526:2010
The active personal dosemeter, RaySafe i2, allows the measurement and record of Hp(10) in real time, every second, via wireless technology for real-time display on a portable computer and/or a local network. The system seems particularly attractive for individual monitoring at clinical facilities where high intensity and varying radiation fields may occur, as it enables the user to acknowledge and optimize the dose and dose rate values in real time for each procedure. Prior to its use, the system was characterized at the Metrology Laboratory of Ionizing Radiation of IST-LPSR aiming at the metrological characterization of the system in accordance with IEC 61526:2010 for metrological control purposes and to verify the technical specifications stated by the manufacturer.
- 1 November 2015
- Published by Elsevier in Radiation Measurements
- Vol. 82, 138-145
The determination of the focal spot size of an X-ray tube from the radiation beam profile
- 1 November 2015
- Published by Elsevier in Radiation Measurements
- Vol. 82, 138-145
The determination of the focal spot size of an X-ray tube from the radiation beam profile
- 1 November 2015
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 116, 189-193
Characterisation of a radionuclide specific laboratory detector system for the metallurgical industry by Monte Carlo simulations
- 1 November 2015
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 116, 189-193
Characterisation of a radionuclide specific laboratory detector system for the metallurgical industry by Monte Carlo simulations
- 26 August 2015
- Published by EDP Sciences in International Journal of Metrology and Quality Engineering
- Vol. 6 (2) , 203
SI physiological units
One of the seven base units of the International System of Units (SI), the candela, which is the unit of the luminous intensity, and its derived units are physiological units. The effect of the optical radiation on human beings is taken into account by introducing a weighting factor, the luminous efficiency, to the definition of radiant quantity of interest. Some SI physiological units are frequently used in other metrological domains, such as ionizing radiation, photochemical and biological activities, acoustics and photobiology. This communication is intended to present some principles underlying the definitions of physiological quantities and units associated to these metrological fields.
- 26 August 2015
- Published by EDP Sciences in International Journal of Metrology and Quality Engineering
- Vol. 6 (2) , 203
SI physiological units
One of the seven base units of the International System of Units (SI), the candela, which is the unit of the luminous intensity, and its derived units are physiological units. The effect of the optical radiation on human beings is taken into account by introducing a weighting factor, the luminous efficiency, to the definition of radiant quantity of interest. Some SI physiological units are frequently used in other metrological domains, such as ionizing radiation, photochemical and biological activities, acoustics and photobiology. This communication is intended to present some principles underlying the definitions of physiological quantities and units associated to these metrological fields.
- 3 March 2015
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 116, 82-86
A comparative study of three ionizing chambers for measurements of personal dose equivalent, Hp(10)
- 3 March 2015
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 116, 82-86
A comparative study of three ionizing chambers for measurements of personal dose equivalent, Hp(10)
- Open Access
- 7 October 2013
- Published by EDP Sciences
- p. 05004
Design, construction and characterization of a portable irradiator to calibrate installed ambient dose equivalent monitors
Calibration of installed dose monitors measuring the ambient dose equivalent, H *(10), should be done periodically according to portuguese national law. These monitors are fixed on the wall of the facility, hospitals or any other installation and usually they are checked in situ. To be able to realize this calibration LMRI (Metrology Laboratory for Ionizing Radiation) constructed a portable irradiator made of lead with a 137Cs source. The dosimetric characterization of the irradiator was realized and the H *(10) was determined at several distances from the irradiator. The profiles at different distances from the irradiator have been performed either experimentally or using the MCNPX code and was observed that the full width at half maximum of the radiation field is a linear function of the distance to the irradiator. The influence of the wall where the monitors are installed was studied by Monte Carlo simulation and correction factors applied to the H *(10) are determined.
- 7 October 2013
- Published by EDP Sciences
- p. 05004
Open AccessDesign, construction and characterization of a portable irradiator to calibrate installed ambient dose equivalent monitors
Calibration of installed dose monitors measuring the ambient dose equivalent, H *(10), should be done periodically according to portuguese national law. These monitors are fixed on the wall of the facility, hospitals or any other installation and usually they are checked in situ. To be able to realize this calibration LMRI (Metrology Laboratory for Ionizing Radiation) constructed a portable irradiator made of lead with a 137Cs source. The dosimetric characterization of the irradiator was realized and the H *(10) was determined at several distances from the irradiator. The profiles at different distances from the irradiator have been performed either experimentally or using the MCNPX code and was observed that the full width at half maximum of the radiation field is a linear function of the distance to the irradiator. The influence of the wall where the monitors are installed was studied by Monte Carlo simulation and correction factors applied to the H *(10) are determined.
- 10 August 2012
- Published by IOP Publishing in Metrologia
- Vol. 49 (5) , S223-S227
Full characterization of the125I IBt Bebig I25.S16 brachytherapy source and sensitivity study of the absorbed dose to water due to the seed dimensional variations
- 10 August 2012
- Published by IOP Publishing in Metrologia
- Vol. 49 (5) , S223-S227
Full characterization of the125I IBt Bebig I25.S16 brachytherapy source and sensitivity study of the absorbed dose to water due to the seed dimensional variations
- 1 July 2012
- Published by Elsevier in Radiation Measurements
- Vol. 47 (7) , 492-500
Monte Carlo modelling for the in vivo lung monitoring of enriched uranium: Results of an international comparison
- 1 July 2012
- Published by Elsevier in Radiation Measurements
- Vol. 47 (7) , 492-500
Monte Carlo modelling for the in vivo lung monitoring of enriched uranium: Results of an international comparison