Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mostafa Sayahkarajy has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Data-Driven Tracing and Directional Control Strategy for a Simulated Continuum Robot Within Anguilliform Locomotion

    by Mostafa Sayahkarajy, Hartmut Witte

    Biorobotics leverages the principles of natural locomotion to enhance the mobility of bioinspired aquatic robots. Among various swimming modes, anguilliform locomotion is particularly recognized as an energy-efficient mode incorporating complex multiphysics. Due to whole-body undulation, the determination of the anguilliform swimmer’s direction is not trivial. Furthermore, the neuromuscular mechanism that controls straight swimming is not fully understood. This study investigates the challenge of predicting and controling the gross motion trajectory of a soft robot that utilizes anguilliform swimming. The robot consists of a six-segment continuous body, where each segment is actuated with pneumatic artificial muscles. A mode extraction technique based on dynamic mode decomposition (DMD) is proposed to identify the robot’s future state. Using the complex-variable delay embedding (CDE) technique, the CDE DMD algorithm is developed to predict the robot trajectory trend. To vary the robot direction, a hypothesis that asymmetric sidewise actuation results in slightly different fluid velocities between the left and right sides of the robot was investigated using COMSOL Multiphysics® 6.2. The simulation results demonstrate the CDE DMD’s ability to predict gross motion across various scenarios. Furthermore, integrating the prediction model with the asymmetric actuation rule provides a control strategy for directional stability of the robot. Simulations of the closed-loop system with non-zero initial pose (step response) indicate the performance in maintaining straight-line swimming with approximately a 60s settling time.

  • Open Access

    A DMD-Based Directional Stability Control of an Anguilliform Swimming Continuum Robot

    by Mostafa Sayahkarajy, Hartmut Witte

    Biorobotics employs principles of natural locomotion to improve robots' mobility. Among various swimming modes, anguilliform locomotion is particularly recognized as an energy-efficient mode that incorporates complex physics. Due to whole-body undulation, the determination of the anguilliform swimmer’s direction is not trivial, and the mechanism of muscle interaction to maintain the desired direction is complex. In this study, the problem of predicting and controlling the gross motion trajectory of a soft robot with anguilliform swimming on the water surface is investigated. The robot consists of a six-segment continuous body, where each segment is actuated with artificial muscles to bend left and right. A DMD-based mode extraction technique is proposed to identify the robot's trajectory, which represents the heading direction. The algorithm, namely CDE DMD, utilizes delay-embedded complex variable states to calculate the future trend of the robot state. For the control, a hypothesis that asymmetric sidewise actuation results in regulation of the swimming direction was investigated using COMSOL Multiphysics® 6.2. The results demonstrate the CDE DMD ability to predict gross motion for various scenarios. The prediction and asymmetric actuation rules can be used to maintain swimming in a straight line, a problem which is known as directional stability.

  • Open Access

    Empirical Data-Driven Linear Model of a Swimming Robot Using the Complex Delay-Embedding DMD Technique

    by Mostafa Sayahkarajy, Hartmut Witte

    Anguilliform locomotion, an efficient aquatic locomotion mode where the whole body is engaged in fluid–body interaction, contains sophisticated physics. We hypothesized that data-driven modeling techniques may extract models or patterns of the swimmers’ dynamics without implicitly measuring the hydrodynamic variables. This work proposes empirical kinematic control and data-driven modeling of a soft swimming robot. The robot comprises six serially connected segments that can individually bend with the segmental pneumatic artificial muscles. Kinematic equations and relations are proposed to measure the desired actuation to mimic anguilliform locomotion kinematics. The robot was tested experimentally and the position and velocities of spatially digitized points were collected using QualiSys® Tracking Manager (QTM) 1.6.0.1. The collected data were analyzed offline, proposing a new complex variable delay-embedding dynamic mode decomposition (CDE DMD) algorithm that combines complex state filtering and time embedding to extract a linear approximate model. While the experimental results exhibited exotic curves in phase plane and time series, the analysis results showed that the proposed algorithm extracts linear and chaotic modes contributing to the data. It is concluded that the robot dynamics can be described by the linearized model interrupted by chaotic modes. The technique successfully extracts coherent modes from limited measurements and linearizes the system dynamics.


  • Open Access

    Temporal Evolution of the Hydrodynamics of a Swimming Eel Robot Using Sparse Identification: SINDy-DMD

    by Mostafa Sayahkarajy, Hartmut Witte

    Anguilliform swimming is one of the most complex locomotion modes, involving various interacting phenomena, necessitating multidisciplinary studies. Eel robots are designed to incorporate biological principles and achieve efficient locomotion by replicating natural anguilliform swimming. These robots are simpler to engineer and study compared to their natural counterparts. Nevertheless, characterizing the robot–environment interaction is complex, demanding computationally expensive fluid dynamics simulations. In this study, we employ machine learning strategies to investigate the temporal evolution of the system and discover a data-driven model. Three methods were studied, including dynamic mode decomposition (DMD), sparse system identification (SINDy using PySINDy package), and autoencoder neural network (AE NN), as a general function approximator. The models were simulated using MATLAB® R2022 to obtain the prediction errors. The results show that the SINDy model presents less error within the regression range and performs better in extrapolation. Additionally, the SINDy model has a compact form and can explicitly formulate the coupling phenomena amongst the modes. Thus, instead of the standard DMD, we propose the SINDy-DMD approach to describe the anguilliform locomotion of the soft robot. The identified model was employed to recover the system state data matrix. It is concluded that the proposed model with quadratic terms provides a parsimonious representation of the system dynamics.


  • Open Access

    Temporal Evolution of Dynamics of a Swimming Robot Using Sparse Identification

    by Mostafa Sayahkarajy, Hartmut Witte

    Anguilliform swimming is one of the most complex locomotion modes, involving various interacting phenomena, which requires multidisciplinary studies. Eel robots are intended to employ biology principles and exhibit efficient locomotion replicating the natural anguilliform swimming. Such robots are easier to engineer and study than their natural counterparts. Nevertheless, characterizing the robot–environment interaction is complex, demanding computationally expensive fluid dynamics modeling. In this study, we employ machine learning (ML) strategies to discover the temporal evolution of the system, as the data-driven model. Three models were investigated using dynamic mode decomposition (DMD), sparse system identification (SINDy using PySINDy package), and autoencoder neural network (AE NN) as a general function approximator. The models were simulated using MATLAB R2022® to obtain the prediction errors. The results show that the SINDy model presents less error within the regression range, and in particular, performs better within extrapolation. Additionally, the SINDy model has a compact form and can explicitly formulate the coupling phenomena amongst the modes. The identified model, then, was employed to recover the system state data matrix. It is concluded that the proposed model with quadratic terms provides a parsimonious representation of the system dynamics.


  • Open Access

    Analysis of Robot–Environment Interaction Modes in Anguilliform Locomotion of a New Soft Eel Robot

    by Mostafa Sayahkarajy, Hartmut Witte

    Bio-inspired robots with elongated anatomy, like eels, are studied to discover anguilliform swimming principles and improve the robots’ locomotion accordingly. Soft continuum robots replicate animal–environment physics better than noncompliant, rigid, multi-body eel robots. In this study, a slender soft robot was designed and tested in an actual swimming experiment in a still-water tank. The robot employs soft pneumatic muscles laterally connected to a flexible backbone and activated with a rhythmic input. The position of seven markers mounted on the robot’s backbone was recorded using QualiSys® Tracking Manager (QTM) 1.6.0.1. The system was modeled as a fully coupled fluid–solid interaction (FSI) system using COMSOL Multiphysics® 6.1. Further data postprocessing and analysis were conducted, proposing a new mode decomposition algorithm using simulation data. Experiments show the success of swimming with a velocity of 28 mm/s and at a frequency of 0.9 Hz. The mode analysis allowed the modeling and explanation of the fluctuation. Results disclose the presence of traveling waves related to anguilliform waves obtained by the superposition of two main modes. The similarities of the results with natural anguilliform locomotion are discussed. It is concluded that soft robot undulation is ruled by dynamic modes induced by robot–environment interaction.


  • A multi-chamber soft robot for transesophageal echocardiography: continuous kinematic matching control of soft medical robots

    by Mostafa Sayahkarajy, Hartmut Witte

    Objectives: This research investigates designing a continuum soft robot and proposing a kinematic matching control to enable the robot to perform a specified medical task, which in this paper is the transesophageal echocardiography (TEE). Methods: A multi-chamber soft robot was designed and fabricated based on the molding of separate layers. The method of transformation matrices was used to develop the kinematic models, and a control method using Jacobian matrices was proposed to manipulate the robot. Results: A prototype was made based on a multi-chamber multi-layer design. The system contains three segments that can be actuated independently to mimic the active bending part of the respective probe. Kinematic models were developed. Negative pressure (vacuum) was used as actuation input. An open-loop controller inspired by a redundancy resolution technique was proposed to make the soft robot tip follow the desired path, i.e. the path of the rigid ultrasound probe. Conclusions: It is concluded that the soft solution can perform the required task as the reachable points of the TEE tip cover the proposed robot workspace and the proposed control can be used for maneuvering in arbitrary trajectories.


  • Open Access

    Chorda Dorsalis System as a Paragon for Soft Medical Robots to Design Echocardiography Probes with a New SOM-Based Steering Control

    by Mostafa Sayahkarajy, Hartmut Witte, Ahmad Athif Mohd Faudzi

    Continuum robots play the role of end effectors in various surgical robots and endoscopic devices. While soft continuum robots (SCRs) have proven advantages such as safety and compliance, more research and development are required to enhance their capability for specific medical scenarios. This research aims at designing a soft robot, considering the concepts of geometric and kinematic similarities. The chosen application is a semi-invasive medical application known as transesophageal echocardiography (TEE). The feasibility of fabrication of a soft endoscopic device derived from the Chorda dorsalis paragon was shown empirically by producing a three-segment pneumatic SCR. The main novelties include bioinspired design, modeling, and a navigation control strategy presented as a novel algorithm to maintain a kinematic similarity between the soft robot and the rigid counterpart. The kinematic model was derived based on the method of transformation matrices, and an algorithm based on a self-organizing map (SOM) network was developed and applied to realize kinematic similarity. The simulation results indicate that the control method forces the soft robot tip to follow the path of the rigid probe within the prescribed distance error (5 mm). The solution provides a soft robot that can surrogate and succeed the traditional rigid counterpart owing to size, workspace, and kinematics.


  • Open Access

    Chorda Dorsalis System as a Paragon for Locally Actuated Compliant Bending Beams to Improve the Performance of TEE Probes

    by Mostafa Sayahkarajy, Hartmut Witte, A. Athif M. Faudzi

    Continuum robots play the role of end-effector in various surgical robots and endoscopic devices. The robots may be categorized as rigid or soft continuum robots (SCRs). While the SCRs have proven advantages such as safety and compliance, more research and development are required to enhance their capability for specific medical scenarios. This research aims at designing a soft robot considering concepts of geometric and kinematic similarities. The chosen application is a semi-invasive medical application known as Transesophageal Echocardiography (TEE), but the methodology can be implemented in other similar applications. Since established rigid carrier construction make use of principles we find as well embodied in vertebral spines, the paragon for soft robot solution can be the phylogenetic precursor of the spine, the Chorda dorsalis. The feasibility of fabrication of a soft endoscopic device derived from that paragon within a robotics laboratory was shown empirically by producing a three-segment pneumatic SCR. The kinematic model was proposed based on the method of transformation matrices, and an algorithm based on a self-organizing map (SOM) was proposed and applied to realize kinematic similarity. The simulation results indicate that the algorithm acting as an open-loop controller forces the soft robot tip to follow the desired path which in this case is the path of the rigid probe. It is concluded that the solution provides a soft robot that can surrogate and succeed the traditional rigid counterpart owing to size, workspace, and kinematics.