Elsaeed Ali
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Elsaeed Ali has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Om Parkash Malik
University of Calgary, Canada
3 shared publications - Sobhy Mohamed Abdelkader
Electrical Power Engineering, Egypt-Japan University of Science and Technology (E-JUST), New Borg El-Arab City, Alexandria, Egypt
3 shared publications A. Helal
2 shared publications- Andrew M. Knight
Department of Electrical and Software Engineering, University of Calgary, Calgary, AB, Canada
2 shared publications H. Desouki
2 shared publicationsA. Knight
1 shared publication
Latest Publications
- Open Access
- 29 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 147295-147305
An Enhanced Algorithm for Conventional Protection Devices of Transmission Lines With DTLR
As the installed capacity of renewable generation continues to increase nowadays to satisfy both emissions and economic requirements, the nature of intermittent generation results in a need to further increase transmission capacity. Dynamic thermal line rating may be used to increase the capacity of transmission lines without upgrading infrastructure. However, existing transmission line protection devices may mal-operate due to the increased capacity. So, it is required to evaluate the performance of existing protection devices. This paper proposes an algorithm that enhances the performance of existing conventional relays such as distance and overcurrent relays. The proposed algorithm is based on a combination of dynamic thermal rating, current ratio of negative and positive sequences and voltage criterion to detect faults whether symmetrical or asymmetrical and unsafe overload. In addition, it aims at restraining the existing relays during safe overloads. A model of a system under investigation is simulated, with studies are performed in MATLAB/Simulink environment. The results demonstrate the ability of the proposed scheme to detect all types of faults and unsafe overload dependably and restrain the conventional relays securely during safe overloads.
- 29 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 147295-147305
Open AccessAn Enhanced Algorithm for Conventional Protection Devices of Transmission Lines With DTLR
As the installed capacity of renewable generation continues to increase nowadays to satisfy both emissions and economic requirements, the nature of intermittent generation results in a need to further increase transmission capacity. Dynamic thermal line rating may be used to increase the capacity of transmission lines without upgrading infrastructure. However, existing transmission line protection devices may mal-operate due to the increased capacity. So, it is required to evaluate the performance of existing protection devices. This paper proposes an algorithm that enhances the performance of existing conventional relays such as distance and overcurrent relays. The proposed algorithm is based on a combination of dynamic thermal rating, current ratio of negative and positive sequences and voltage criterion to detect faults whether symmetrical or asymmetrical and unsafe overload. In addition, it aims at restraining the existing relays during safe overloads. A model of a system under investigation is simulated, with studies are performed in MATLAB/Simulink environment. The results demonstrate the ability of the proposed scheme to detect all types of faults and unsafe overload dependably and restrain the conventional relays securely during safe overloads.
- 6 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (6) , 1-10
Performance of Ratios‐Based Transformer Differential Protection Scheme in the Presence of Resistive Superconductor Fault Current Limiter
With increased demand for electrical power, it is required to increase the number of power transformers in power systems. One of the main challenges facing protection engineers is the protection and isolation of power transformers, in the shortest time possible, during internal faults. One of the alternative solutions to reduce fault current in the power system is the application of superconductor fault current limiter (SFCL). In this paper, the ratios-based transformer differential protection algorithm is evaluated in the presence of resistive SFCL during internal fault conditions. A model of the system under study including SFCL is simulated and studies are performed in MATLAB/Simulink environment. The results demonstrate the capability of the ratios-based differential protection scheme to detect internal faults in the presence of SFCL.
- 6 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (6) , 1-10
Performance of Ratios‐Based Transformer Differential Protection Scheme in the Presence of Resistive Superconductor Fault Current Limiter
With increased demand for electrical power, it is required to increase the number of power transformers in power systems. One of the main challenges facing protection engineers is the protection and isolation of power transformers, in the shortest time possible, during internal faults. One of the alternative solutions to reduce fault current in the power system is the application of superconductor fault current limiter (SFCL). In this paper, the ratios-based transformer differential protection algorithm is evaluated in the presence of resistive SFCL during internal fault conditions. A model of the system under study including SFCL is simulated and studies are performed in MATLAB/Simulink environment. The results demonstrate the capability of the ratios-based differential protection scheme to detect internal faults in the presence of SFCL.
- 1 September 2020
- Published by Elsevier in Electric Power Systems Research
- Vol. 186
Ratios-based universal differential protection algorithm for power transformer
- 1 September 2020
- Published by Elsevier in Electric Power Systems Research
- Vol. 186
Ratios-based universal differential protection algorithm for power transformer
- 9 July 2019
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 29 (11)
Experimental results of ratios‐based transformer differential protection scheme
- 9 July 2019
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 29 (11)
Experimental results of ratios‐based transformer differential protection scheme
- 1 January 2018
- Published by Elsevier in Electric Power Systems Research
- Vol. 154, 140-150
Power transformer differential protection using current and voltage ratios
- 1 January 2018
- Published by Elsevier in Electric Power Systems Research
- Vol. 154, 140-150
Power transformer differential protection using current and voltage ratios