Ana Catarina Lopes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ana Catarina Lopes has a total of 116 co-authors. Here are the top co-authors by number of shared publications:
- Senentxu Lanceros Mendez
BCMaterials, Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940 Leioa, Spain
26 shared publications - Gabriela Botelho
Center of Chemistry, University of Minho, 4710-057 Braga, Portugal
11 shared publications - Carlos Miguel Costa
Physics Centre of Minho and Porto Universities (CF-UM-UP), University of Minho, Campus de Gualtar, 4710-057 Braga, Portugal
7 shared publications - Jon Gutierrez
Departamento de Electricidad y Electrónica, Universidad del País Vasco, UPV/EHU. Barrio Sarriena S/N, Leioa 48940, Spain
7 shared publications - Isabel Correia Neves
CQUM, Centro de Química, Departamento de Química, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal
6 shared publications - Andoni Lasheras
Departamento de Electricidad y Electrónica, Universidad del País Vasco UPV/EHU, P.O. Box 644, 48080 Bilbao, Spain
5 shared publications
Latest Publications
- Open Access
- 13 August 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 394
Magneto-mechanical behavior in polyurethane foams containing oriented FeCo microparticles: A competition between bending and stretching effects
- 13 August 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 394
Open AccessMagneto-mechanical behavior in polyurethane foams containing oriented FeCo microparticles: A competition between bending and stretching effects
- Open Access
- 11 October 2024
- Published by Elsevier in Sensors and Actuators Reports
- Vol. 8
Development of nanocrystallized magnetoelastic sensors with self-biased effect and improved mass sensitivity
- 11 October 2024
- Published by Elsevier in Sensors and Actuators Reports
- Vol. 8
Open AccessDevelopment of nanocrystallized magnetoelastic sensors with self-biased effect and improved mass sensitivity
- 10 May 2023
- Published by Udako Euskal Unibertsitatea
Nobel Saridun Klik erreakzioaren baliagarritasuna konposatu biologikoak eransteko polimero gainazalean
Nobel Saridun Klik erreakzioaren baliagarritasuna konposatu biologikoak eransteko polimero gainazalean produkzioaren informazio-fitxa
- 10 May 2023
- Published by Udako Euskal Unibertsitatea
Nobel Saridun Klik erreakzioaren baliagarritasuna konposatu biologikoak eransteko polimero gainazalean
Nobel Saridun Klik erreakzioaren baliagarritasuna konposatu biologikoak eransteko polimero gainazalean produkzioaren informazio-fitxa
- 1 March 2023
- Published by IATED Academy in INTED Proceedings
- Vol. 1, 8095-8098
ENHANCING PHYSICAL CHEMISTRY KNOWLEDGE AND SOFT SKILLS BY SHORT IN-CLASS ACTIVITIES
- 1 March 2023
- Published by IATED Academy in INTED Proceedings
- Vol. 1, 8095-8098
ENHANCING PHYSICAL CHEMISTRY KNOWLEDGE AND SOFT SKILLS BY SHORT IN-CLASS ACTIVITIES
- Open Access
- 24 February 2023
- Published by Elsevier in Journal of Power Sources
- Vol. 564
DFT calculation, a practical tool to predict the electrochemical behaviour of organic electrolytes in aqueous redox flow batteries
- 24 February 2023
- Published by Elsevier in Journal of Power Sources
- Vol. 564
Open AccessDFT calculation, a practical tool to predict the electrochemical behaviour of organic electrolytes in aqueous redox flow batteries
- 10 September 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 8 (39) , 13743-13753
Rhombic-magnetoelastic/metal–organic framework functionalized resonators for highly sensitive toluene detection
The monitoring of different harmful gases such as volatile organic compounds (VOCs) is essential to ensure the air quality and population security. Therefore, the development of rapid, cheap and accurate sensing devices is a key to enable continuous monitoring of the air quality. On this matter, magnetoelastic sensors, particularly the rhombus-shaped ones, have become an interesting alternative to the current sensing systems because, besides exhibiting a fast response, they present a wireless sensing capacity. Moreover, the addition of metal–organic frameworks (MOFs) as highly porous active layers to different sensing devices endows them with the desired adsorption capacity and selectivity to detect VOCs. Therefore, in this work, we explore the performance of a highly sensitive rhombic magnetoelastic Metglas 2826 MB resonator functionalized with a high-toluene adsorption capacity MOF layer (i.e. UiO66-NH2) for its wireless detection. Our findings confirm the feasibility of the Metglas/MOF system for fast and reversible toluene detection, being key the control of the active layer mass to improve its sensitivity. From the toluene sensing experiments, a maximum sensitivity of 0.27 Hz ppm−1 was determined. Finally, the sensor selectivity has been evaluated through the analysis of the sensor response to different atmospheres (water, acetone, ethanol and toluene) and it was observed that the sensor presents an enhanced selectivity towards toluene. Given the structural diversity and chemical tunability of MOF materials, their use as active sorbent layers in resonator systems together with the possibility to further optimize the resonator geometry to improve the sensitivity and the MOF structure to gain more selectivity, opens up the possibility for the facile and straightforward designing of future wireless sensors for any kind of environmentally hazardous substance.
- 10 September 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 8 (39) , 13743-13753
Rhombic-magnetoelastic/metal–organic framework functionalized resonators for highly sensitive toluene detection
The monitoring of different harmful gases such as volatile organic compounds (VOCs) is essential to ensure the air quality and population security. Therefore, the development of rapid, cheap and accurate sensing devices is a key to enable continuous monitoring of the air quality. On this matter, magnetoelastic sensors, particularly the rhombus-shaped ones, have become an interesting alternative to the current sensing systems because, besides exhibiting a fast response, they present a wireless sensing capacity. Moreover, the addition of metal–organic frameworks (MOFs) as highly porous active layers to different sensing devices endows them with the desired adsorption capacity and selectivity to detect VOCs. Therefore, in this work, we explore the performance of a highly sensitive rhombic magnetoelastic Metglas 2826 MB resonator functionalized with a high-toluene adsorption capacity MOF layer (i.e. UiO66-NH2) for its wireless detection. Our findings confirm the feasibility of the Metglas/MOF system for fast and reversible toluene detection, being key the control of the active layer mass to improve its sensitivity. From the toluene sensing experiments, a maximum sensitivity of 0.27 Hz ppm−1 was determined. Finally, the sensor selectivity has been evaluated through the analysis of the sensor response to different atmospheres (water, acetone, ethanol and toluene) and it was observed that the sensor presents an enhanced selectivity towards toluene. Given the structural diversity and chemical tunability of MOF materials, their use as active sorbent layers in resonator systems together with the possibility to further optimize the resonator geometry to improve the sensitivity and the MOF structure to gain more selectivity, opens up the possibility for the facile and straightforward designing of future wireless sensors for any kind of environmentally hazardous substance.
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (22) , 13332-13340
Theoretical and Experimental Analysis of Novel Rhombus Shaped Magnetoelastic Sensors With Enhanced Mass Sensitivity
Magnetoelastic resonant platforms are gaining attention in different sensing applications due mainly to their wireless detecting capacity. In that way, the improvement of the main parameters of those devices turns out to be essential in the development of advanced functional magnetoelastic resonators. In our attempt to improve such systems, we concluded that modified geometries of the resonant platforms can be a good alternative to achieve higher mass sensitivities. In this work, a novel high sensitive rhombus shaped magnetoelastic resonant platform design has been proposed. The obtained mass sensitivities have been both experimentally and theoretically compared with the classical rectangular sensors case. The results of these novel sensor geometry performance show an increase on the resonance frequency value by a factor of 1.53 with respect to the traditional rectangular one and, as a first consequence, an improvement of more than a 60 % in the mass sensitivity value. Besides, a multiple detection system based on a combination of both magnetoelastic platform geometries has been developed. The obtained results are very promising in the goal of achieving improved and novel multiple detection systems.
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (22) , 13332-13340
Theoretical and Experimental Analysis of Novel Rhombus Shaped Magnetoelastic Sensors With Enhanced Mass Sensitivity
Magnetoelastic resonant platforms are gaining attention in different sensing applications due mainly to their wireless detecting capacity. In that way, the improvement of the main parameters of those devices turns out to be essential in the development of advanced functional magnetoelastic resonators. In our attempt to improve such systems, we concluded that modified geometries of the resonant platforms can be a good alternative to achieve higher mass sensitivities. In this work, a novel high sensitive rhombus shaped magnetoelastic resonant platform design has been proposed. The obtained mass sensitivities have been both experimentally and theoretically compared with the classical rectangular sensors case. The results of these novel sensor geometry performance show an increase on the resonance frequency value by a factor of 1.53 with respect to the traditional rectangular one and, as a first consequence, an improvement of more than a 60 % in the mass sensitivity value. Besides, a multiple detection system based on a combination of both magnetoelastic platform geometries has been developed. The obtained results are very promising in the goal of achieving improved and novel multiple detection systems.
- 23 June 2020
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 29 (8) , 085041
Development of novel piezo-ionic/magnetostrictive composites for energy generation systems
Novel piezo-ionic/magnetostrictive bi-layer composites for new energy generation devices are presented. These structures, fabricated with Metglas® 2826MB ferromagnetic alloys and ionic liquid based PVDF-HFP polymer composites, show an induced electric response as a consequence of the coupling between the magnetostrictive properties of the Metglas® 2826MB and the piezo-ionic ones of the ionic liquid based PVDF-HFP polymer composites. These flexible, simple and low cost structures do not need to be polarized to exhibit an electric response, and show an increased induced voltage as the percentage of the ionic liquid in the PVDF-HFP matrix does. This response is a consequence of the asymmetric deformation caused by the magnetostrictive material on the piezo-ionic composite, which induces a non-uniform distribution of the cations and anions in the polymer matrix. The laminates present a maximum response under the application of a low magnetic fields of 9 Oe, and a normalized magneto-ionic coefficient values up to 550 mV/cm.Oe for the structure with an ionic liquid content of 30 %. These values are even higher than others obtained with piezoelectric materials based ME composites. The simple fabrication process and potentiality of these new piezo-ionic/magnetostrictive laminates contributes to broaden and improve the state of the art of the energy generation systems.
- 23 June 2020
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 29 (8) , 085041
Development of novel piezo-ionic/magnetostrictive composites for energy generation systems
Novel piezo-ionic/magnetostrictive bi-layer composites for new energy generation devices are presented. These structures, fabricated with Metglas® 2826MB ferromagnetic alloys and ionic liquid based PVDF-HFP polymer composites, show an induced electric response as a consequence of the coupling between the magnetostrictive properties of the Metglas® 2826MB and the piezo-ionic ones of the ionic liquid based PVDF-HFP polymer composites. These flexible, simple and low cost structures do not need to be polarized to exhibit an electric response, and show an increased induced voltage as the percentage of the ionic liquid in the PVDF-HFP matrix does. This response is a consequence of the asymmetric deformation caused by the magnetostrictive material on the piezo-ionic composite, which induces a non-uniform distribution of the cations and anions in the polymer matrix. The laminates present a maximum response under the application of a low magnetic fields of 9 Oe, and a normalized magneto-ionic coefficient values up to 550 mV/cm.Oe for the structure with an ionic liquid content of 30 %. These values are even higher than others obtained with piezoelectric materials based ME composites. The simple fabrication process and potentiality of these new piezo-ionic/magnetostrictive laminates contributes to broaden and improve the state of the art of the energy generation systems.
- Open Access
Magnetic, Magnetoelastic and Corrosion Resistant Properties of (Fe–Ni)-Based Metallic Glasses for Structural Health Monitoring Applications
We have performed a study of the magnetic, magnetoelastic, and corrosion resistance properties of seven different composition magnetoelastic-resonant platforms. For some applications, such as structural health monitoring, these materials must have not only good magnetomechanical properties, but also a high corrosion resistance. In the fabricated metallic glasses of composition , the Fe/Ni ratio was varied (Fe + Ni = 73% at.) thus changing the magnetic and magnetoelastic properties. A small amount of chromium was added in order to achieve the desired good corrosion resistance. As expected, all the studied properties change with the composition of the samples. Alloys containing a higher amount of than do not show magnetic behavior at room temperature, while iron-rich alloys have demonstrated not only good magnetic properties, but also good magnetoelastic ones, with magnetoelastic coupling coefficient as high as for in the (the sample containing only but not ). Concerning corrosion resistance, we have found a continuous degradation of these properties as the content increases in the composition. Thus, the corrosion potential decreases monotonously from 46.74 mV for the , composition to −239.47 mV for the , composition .Open AccessMagnetic, Magnetoelastic and Corrosion Resistant Properties of (Fe–Ni)-Based Metallic Glasses for Structural Health Monitoring Applications
We have performed a study of the magnetic, magnetoelastic, and corrosion resistance properties of seven different composition magnetoelastic-resonant platforms. For some applications, such as structural health monitoring, these materials must have not only good magnetomechanical properties, but also a high corrosion resistance. In the fabricated metallic glasses of composition , the Fe/Ni ratio was varied (Fe + Ni = 73% at.) thus changing the magnetic and magnetoelastic properties. A small amount of chromium was added in order to achieve the desired good corrosion resistance. As expected, all the studied properties change with the composition of the samples. Alloys containing a higher amount of than do not show magnetic behavior at room temperature, while iron-rich alloys have demonstrated not only good magnetic properties, but also good magnetoelastic ones, with magnetoelastic coupling coefficient as high as for in the (the sample containing only but not ). Concerning corrosion resistance, we have found a continuous degradation of these properties as the content increases in the composition. Thus, the corrosion potential decreases monotonously from 46.74 mV for the , composition to −239.47 mV for the , composition .