Richard Tresch Fienberg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Richard Tresch Fienberg has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
D. Y. Gezari
5 shared publicationsC. R. McCreight
4 shared publicationsG. G. Fazio
3 shared publicationsG. Lamb
NASA/Goddard Space Flight Center (United States)
3 shared publicationsG. M. Lamb
3 shared publications- Giovanni Fazio
Center for Astrophysics 02138 Cambridge MA USA
3 shared publications
Latest Publications
- 10 December 2025
- Published by American Astronomical Society
- Vol. 57
Ensuring the Safety of Eclipse Glasses and Handheld Solar Viewers
- 10 December 2025
- Published by American Astronomical Society
- Vol. 57
Ensuring the Safety of Eclipse Glasses and Handheld Solar Viewers
- 6 September 2023
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 107 (3) , 1-4
Advice to the public about safe and comfortable eclipse viewing and the 20 April 2023 eclipse
- 6 September 2023
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 107 (3) , 1-4
Advice to the public about safe and comfortable eclipse viewing and the 20 April 2023 eclipse
- Open Access
- 13 August 2021
- Published by American Astronomical Society in The Astronomical Journal
- Vol. 162 (3) , 103
Physical and Visual Evaluation of Filters for Direct Observation of the Sun and the International Standard ISO 12312-2:2015
We investigated the compliance of 43 commercially available solar filters (eclipse glasses) with the ISO 12312-2:2015 standard by measuring their spectral transmittances (280–2000 nm) and calculating their luminous, solar ultraviolet A, ultraviolet B, and infrared (IR) transmittances. We also evaluated the filters for usability by observing the full midday Sun and rating the view on a seven-point balanced scale, from “far too dark, details seen only with great difficulty” to “far too light, uncomfortable to view the Sun.” The mean ratings of two observers, one experienced and one inexperienced in solar observing, differed by 0.28 (95% confidence interval of the mean = 0.26). The inexperienced observer tended to be less accepting of high transmittances. All 43 solar filters complied with the UV and IR requirements. Eighteen filters passed the luminous transmittance requirements, and 24 were borderline too light or too dark. Seven of the 15 solar filters with a luminous transmittance darker than the requirement were rated as acceptable. One filter that passed and another that was borderline too light were rated as too light or far too light. The ISO 12312-2 limits derive from welding filter standards and do not represent an appropriate evidence base for direct solar viewing. This work provides the evidence base for a maximum 0.0012% and a minimum 0.00004% luminous transmittance for solar filters. The results of this study also support the use of welding filters between shades 12 and 16. Lighter welding filters are more acceptable than solar filters of the same luminous transmittance.
- 13 August 2021
- Published by American Astronomical Society in The Astronomical Journal
- Vol. 162 (3) , 103
Open AccessPhysical and Visual Evaluation of Filters for Direct Observation of the Sun and the International Standard ISO 12312-2:2015
We investigated the compliance of 43 commercially available solar filters (eclipse glasses) with the ISO 12312-2:2015 standard by measuring their spectral transmittances (280–2000 nm) and calculating their luminous, solar ultraviolet A, ultraviolet B, and infrared (IR) transmittances. We also evaluated the filters for usability by observing the full midday Sun and rating the view on a seven-point balanced scale, from “far too dark, details seen only with great difficulty” to “far too light, uncomfortable to view the Sun.” The mean ratings of two observers, one experienced and one inexperienced in solar observing, differed by 0.28 (95% confidence interval of the mean = 0.26). The inexperienced observer tended to be less accepting of high transmittances. All 43 solar filters complied with the UV and IR requirements. Eighteen filters passed the luminous transmittance requirements, and 24 were borderline too light or too dark. Seven of the 15 solar filters with a luminous transmittance darker than the requirement were rated as acceptable. One filter that passed and another that was borderline too light were rated as too light or far too light. The ISO 12312-2 limits derive from welding filter standards and do not represent an appropriate evidence base for direct solar viewing. This work provides the evidence base for a maximum 0.0012% and a minimum 0.00004% luminous transmittance for solar filters. The results of this study also support the use of welding filters between shades 12 and 16. Lighter welding filters are more acceptable than solar filters of the same luminous transmittance.
- 25 March 2011
- Published by Springer Nature
- p. 37-46
Communicating Astronomy Beyond IYA2009
- 16 July 2010
- Published by SPIE-Intl Soc Optical Eng
- p. 773803-773803-10
Optical and system engineering in the development of a high-quality student telescope kit
The Galileoscope student telescope kit was developed by a volunteer team of astronomers, science education experts, and optical engineers in conjunction with the International Year of Astronomy 2009. This refracting telescope is in production with over 180,000 units produced and distributed with 25,000 units in production. The telescope was designed to be able to resolve the rings of Saturn and to be used in urban areas. The telescope system requirements, performance metrics, and architecture were established after an analysis of current inexpensive telescopes and student telescope kits. The optical design approaches used in the various prototypes and the optical system engineering tradeoffs will be described. Risk analysis, risk management, and change management were critical as was cost management since the final product was to cost around $15 (but had to perform as well as $100 telescopes). In the system engineering of the Galileoscope a variety of analysis and testing approaches were used, including stray light design and analysis using the powerful optical analysis program FRED™.
- 16 July 2010
- Published by SPIE-Intl Soc Optical Eng
- p. 773803-773803-10
Optical and system engineering in the development of a high-quality student telescope kit
The Galileoscope student telescope kit was developed by a volunteer team of astronomers, science education experts, and optical engineers in conjunction with the International Year of Astronomy 2009. This refracting telescope is in production with over 180,000 units produced and distributed with 25,000 units in production. The telescope was designed to be able to resolve the rings of Saturn and to be used in urban areas. The telescope system requirements, performance metrics, and architecture were established after an analysis of current inexpensive telescopes and student telescope kits. The optical design approaches used in the various prototypes and the optical system engineering tradeoffs will be described. Risk analysis, risk management, and change management were critical as was cost management since the final product was to cost around $15 (but had to perform as well as $100 telescopes). In the system engineering of the Galileoscope a variety of analysis and testing approaches were used, including stray light design and analysis using the powerful optical analysis program FRED™.
- Open Access
- 2 September 2004
- Published by IOP Publishing in New Journal of Physics
- Vol. 6 (1) , 114
SNEWS: the SuperNova Early Warning System
- 2 September 2004
- Published by IOP Publishing in New Journal of Physics
- Vol. 6 (1) , 114
Open AccessSNEWS: the SuperNova Early Warning System
- 1 March 1989
- Published by American Astronomical Society in The Astronomical Journal
- Vol. 97, 809
Images of the 10-micron source in the Cygnus 'Egg'
- 1 March 1989
- Published by American Astronomical Society in The Astronomical Journal
- Vol. 97, 809
Images of the 10-micron source in the Cygnus 'Egg'
- 1 January 1987
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 312, 542
Structure in the nucleus of NGC 1068 at 10 microns
- 1 January 1987
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 312, 542
Structure in the nucleus of NGC 1068 at 10 microns
- 18 July 1986
- Published by SPIE-Intl Soc Optical Eng
- Vol. 0619, 60-69
Wide Field And Diffraction Limited Array Camera For SIRTF
The Infrared Array Camera for the Space Infrared Telescope Facility (SIRTF/IRAC) is capable of two-dimensional photometry in either a wide field or diffraction-limited mode over the wavelength interval from 2 to 30 microns. Three different two-dimensional direct readout (DRO) array detectors are being considered: Band 1 - InSb or Si:In (2 - 5 microns) 128 x 128 pixels, Band 2 - Si:Ga (5 - 18 microns) 64 x 64 pixels, and Band 3 - Si:Sb (18 -30 microns) 64 x 64 pixels. The hybrid DRO readout architecture has the advantages of low read noise, random pixel access with individual readout rates, and non-destructive readout. The scientific goals of IRAC are discussed, which are the basis for several important requirements and capabilities of the array camera: 1) diffraction-limited resolution from 2 - 30 microns, 2) use of the maximum unvignetted field of view of SIRTF, 3) simultaneous observations within the three infrared spectral bands, 4) the capability for broad and narrow bandwith spectral resolution. A strategy has been developed to minimize the total electronic and environmental noise sources to satisfy the scientific requirements.
- 18 July 1986
- Published by SPIE-Intl Soc Optical Eng
- Vol. 0619, 60-69
Wide Field And Diffraction Limited Array Camera For SIRTF
The Infrared Array Camera for the Space Infrared Telescope Facility (SIRTF/IRAC) is capable of two-dimensional photometry in either a wide field or diffraction-limited mode over the wavelength interval from 2 to 30 microns. Three different two-dimensional direct readout (DRO) array detectors are being considered: Band 1 - InSb or Si:In (2 - 5 microns) 128 x 128 pixels, Band 2 - Si:Ga (5 - 18 microns) 64 x 64 pixels, and Band 3 - Si:Sb (18 -30 microns) 64 x 64 pixels. The hybrid DRO readout architecture has the advantages of low read noise, random pixel access with individual readout rates, and non-destructive readout. The scientific goals of IRAC are discussed, which are the basis for several important requirements and capabilities of the array camera: 1) diffraction-limited resolution from 2 - 30 microns, 2) use of the maximum unvignetted field of view of SIRTF, 3) simultaneous observations within the three infrared spectral bands, 4) the capability for broad and narrow bandwith spectral resolution. A strategy has been developed to minimize the total electronic and environmental noise sources to satisfy the scientific requirements.
- 1 May 1986
- Published by SPIE-Intl Soc Optical Eng
- Vol. 0589, 229-238
Wide Field And Diffraction Limited Array Camera For SIRTF
The Infrared Array Camera for the Space Infrared Telescope Facility (SIRTF/IRAC) is capable of two-dimensional photometry in either a wide field or diffraction-limited mode over the wavelength interval from 2 to 30 microns. Three different two-dimensional direct readout (DRO) array detectors will be used: Band 1 - InSb or Si:In (2 - 5 microns) 128 x 128 pixels, Band 2 - Si:Ga (5 - 18 microns) 64 x 64 pixels, and Band 3 - Si:Sb (18 - 30 microns) 64 x 64 pixels. The hybrid DRO readout architecture has the advantages of low read noise, random pixel access with individual readout rates, and non-destructive readout. The scientific goals of IRAC are discussed, which are the basis for several important requirements and capabilities of the array camera: 1) diffraction-limited resolution from 2 - 30 microns, 2) use of the maximum unvignetted field of view of SIRTF, 3) simultaneous observations within the three infrared spectral bands, 4) the capability for broad and narrow bandwith spectral resolution. A strategy has been developed to minimize the total electronic and environmental noise sources to satisfy the scientific requirements.
- 1 May 1986
- Published by SPIE-Intl Soc Optical Eng
- Vol. 0589, 229-238
Wide Field And Diffraction Limited Array Camera For SIRTF
The Infrared Array Camera for the Space Infrared Telescope Facility (SIRTF/IRAC) is capable of two-dimensional photometry in either a wide field or diffraction-limited mode over the wavelength interval from 2 to 30 microns. Three different two-dimensional direct readout (DRO) array detectors will be used: Band 1 - InSb or Si:In (2 - 5 microns) 128 x 128 pixels, Band 2 - Si:Ga (5 - 18 microns) 64 x 64 pixels, and Band 3 - Si:Sb (18 - 30 microns) 64 x 64 pixels. The hybrid DRO readout architecture has the advantages of low read noise, random pixel access with individual readout rates, and non-destructive readout. The scientific goals of IRAC are discussed, which are the basis for several important requirements and capabilities of the array camera: 1) diffraction-limited resolution from 2 - 30 microns, 2) use of the maximum unvignetted field of view of SIRTF, 3) simultaneous observations within the three infrared spectral bands, 4) the capability for broad and narrow bandwith spectral resolution. A strategy has been developed to minimize the total electronic and environmental noise sources to satisfy the scientific requirements.