WRWillem Jan van Rooij

Willem Jan van Rooij

*This is an algorithmically generated author record based on publicly available information.

Willem Jan van Rooij has a total of 129 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    WEB Treatment of Ruptured Intracranial Aneurysms: Long-Term Follow-up of a Single-Center Cohort of 100 Patients

    by H. Kortman, S.B.T. van Rooij, U. Mutlu, I. Boukrab, W.J. van Rooij, B. van der Pol, B. Burhani, J.P.P. Peluso

    BACKGROUND AND PURPOSE: The Woven EndoBridge device (WEB) was introduced for the intrasaccular treatment of wide-neck aneurysms without the need for adjunctive devices. We used the WEB as a primary treatment for 100 ruptured aneurysms regardless of neck size or location. In this study, we present the long-term follow-up of 78 surviving patients. MATERIALS AND METHODS: Between February 2015 and April 2017, one hundred ruptured aneurysms were treated with the WEB. For surviving patients, angiographic and clinical follow-up was scheduled at 3 months, and 3T MRA and clinical follow-up, at 6, 12, 36, and 60 months. Of 100 patients, 18 died during hospital admission, and in 4, the ruptured aneurysm was additionally treated. The remaining 78 patients had a mean follow-up of 51 months (median, 52 months; range, 5–84 months). There were 57 women and 21 men, with a mean age of 58.5 years (median, 59 years; range, 24–80 years). Of 78 aneurysms with long-term follow-up, 52 (66%) had a wide neck. RESULTS: Of 78 ruptured aneurysms, 56 (72%) remained completely occluded and 17 (22%) had a stable small neck remnant. Five of 78 aneurysms (6%; 95% CI, 2.4%–14.5%) reopened during follow-up and were additionally treated. There were no rebleeds during follow-up. CONCLUSIONS: Treatment of ruptured aneurysms with the WEB was safe and effective and has long-term results comparable with those of simple coiling of small-neck aneurysms. The WEB proved to be a valuable alternative to coils for both wide- and small-neck ruptured aneurysms without the need for stents, balloons, or antiplatelet therapy.


  • The Woven EndoBridge for unruptured intracranial aneurysms: Results in 95 aneurysms from a single center

    by Tom De Beule, Thierry Boulanger, Sam Heye, Williem J van Rooij, Wim van Zwam, Luc Stockx

    Background and purpose: The Woven EndoBridge (WEB) is an intrasaccular flowdisruptor that is increasingly used for the treatment of (wide-necked) aneurysms. We present our experience with the WEB for unruptured aneurysms. Materials and methods: Between April 2014 and August 2019, 93 patients with 95 unruptured aneurysms were primarily treated with the WEB. There were 69 women and 24 men, mean age 61 years (median 58, range 37–80). Results: Of 95 aneurysms, 86 had been discovered incidentally, 3 were symptomatic and 6 were additional to another ruptured aneurysm. Location was anterior communicating artery 33, middle cerebral artery 29, basilar tip 19, carotid tip 8, posterior communicating artery 4, posterior inferior cerebellar artery 1, superior cerebellar artery 1. Mean aneurysm size was 6 mm (median 6, range 3–13 mm). In one aneurysm additional coils were used and in another, a stent was placed. There was one procedural rupture without clinical sequelae. There were two thrombo-embolic complications leading to permanent deficit in one patient (mRS 2). Morbidity rate was 1.0% (1 of 93, 95%CI 0.01–6.5%) and mortality was 0% (0 of 93, 95%CI 0.0–4.8%). Angiographic follow-up at six months was available in 85 patients with 87 aneurysms (91%). Of 87 aneurysms, 68 (78%) were completely occluded, 14 (16%) had a neck remnant and 5 were incompletely occluded. Four aneurysms were retreated. Retreatment rate was 4.5% (4 of 87, 95%CI 1.7–13.6%). Conclusion: WEB treatment of unruptured aneurysms is safe and effective. Additional devices are needed only rarely and retreatment at follow-up is infrequent.


  • The p48 flow diverter: First clinical results in 25 aneurysms in three centers

    by Fra Van Den Bergh, T De Beule, Wj van Rooij, Mh Voormolen, T Van der Zijden, L Stockx, Wh van Zwam, H Fransen

    Background: The novel low-profile p48 flow diverter has been designed to treat aneurysms on small vessels of 1.75–3mm. We report our first clinical experiences. Methods: Between March 2018–January 2020, 22 patients with 25 aneurysms were treated with the p48 in 3 centers. One patient had 3 aneurysms covered by one p48 and one patient had 2 aneurysms. There were 5 men, 17 women, with a mean age of 55 years (median 59, range 29–73 years). Results: In 25 aneurysms, 24 p48 flow diverters were placed. In 1 patient additional coils were placed in the aneurysm. Procedural vessel rupture by the micro guidewire occurred in 2 patients and vessel rupture during p48 balloon dilatation occurred in 1 patient. Overall, the permanent morbidity rate was 13.6% (3 of 22, 95%CI 3.9–34.2%) and mortality was 4.5% (1 of 22, 95%CI <0.01–23.5%). Most complications were procedure-related and not device-specific. Of 22 patients with 25 aneurysms treated with p48, 18 patients with 20 aneurysms had angiographic follow-up after 5–18 months. Of 19 aneurysms, 10 were occluded and 7 showed a remnant. Two aneurysms were open after 6 months. Three aneurysms were still not occluded after 12, 14, and 18 months and these 3 were retreated. Retreatment rate was 16% (3 of 19) and the adequate occlusion rate was 90% (17 of 19). Conclusions: Treatment of aneurysms in small-caliber vessels with the p48 is feasible and effective but is not without complications. More data is needed to establish indications, safety, and efficacy more accurately.


  • p64 flow diverter: Results in 108 patients from a single center

    by Tom De Beule, T Boulanger, S Heye, Wj van Rooij, Wh van Zwam, L Stockx

    Background and purpose: Flow diverters are increasingly used to treat intracranial aneurysms. We report the safety and efficacy of the p64 flow diverter, a resheathable and detachable device for intracranial aneurysms. Materials and methods: We retrospectively reviewed 108 patients with 109 aneurysms treated with the p64 between March 2014 and July 2019. There were 87 women and 21 men, mean age 57 years. Of 109 aneurysms, 74 were discovered incidentally, 12 were symptomatic, 18 were previously treated, and five were ruptured dissection aneurysms. A total of 10 aneurysms were located in the posterior circulation. The mean aneurysm or remnant size was 8.1 mm. Results: Hemorrhage by perforation with the distal guidewire occurred in two patients with permanent neurological deficits in one. In one patient, acute in-stent occlusion caused infarction with a permanent deficit. Permanent morbidity was 1.9% (2 of 108, 95%CI 0.1–6.9%); there was no mortality. During follow-up, three in-stent occlusions occurred, all asymptomatic. There were no delayed hemorrhagic complications. At six months, 77 of 96 aneurysms (80.2%) were completely occluded, and at last follow-up, this increased to 93 of 96 aneurysms (96.9%). In-stent stenosis at any degree occurred in 11 patients, progressing to asymptomatic complete occlusion in one. In the other patients, stenosis resolved or improved at further follow-up. Conclusion: The p64 offers an effective and safe treatment option. Aneurysm occlusion rate was 97% at last follow-up, mostly achieved with a single device. There were no delayed hemorrhagic complications. Delayed in-stent stenosis infrequently progresses to occlusion but remains a matter of concern.


  • A systematic review and meta-analysis of Woven EndoBridge single layer for treatment of intracranial aneurysms

    by Sbt van Rooij, Me Sprengers, Jp Peluso, J Daams, D Verbaan, Wj van Rooij, Cb Majoie

    Background and purpose: The Woven EndoBridge is an intrasaccular device for the treatment of intracranial aneurysms. The first generation consisted of a high-profile double-layer braid. This review aims to evaluate the outcomes of the new generation low-profile Woven EndoBridge single layer device for intracranial aneurysm treatment. Methods: A systematic review was conducted with Medline, Embase, and Web of Science Conference Proceedings databases. The search strategy provided 589 articles, 15 articles were included. Results: Fifteen articles were identified reporting the use of Woven EndoBridge single-layer devices in 963 aneurysms, mostly wide-necked bifurcation aneurysms. Procedural aneurysm rupture was reported in 8 of 963 patients (0.83%; 95%CI 0.39–1.66%) and thromboembolic events in 54 of 963 patients (5.61%, 95CI 4.31–7.26%). Cumulative morbidity was 2.85% (27/949, 95%CI 1.95–4.12%) and mortality 0.93% (9/963, 95%CI 0.46–1.80%). The overall rate of adequate aneurysm occlusion at last follow-up was 83.3% (613/736; 95%CI 80.4–85.8%). Retreatment was reported in 38 aneurysms in eight studies with 450 aneurysms with follow-up (38/450; 8.4%, 95CI 6.2–11.4%). In 12 studies comprising 644 aneurysms with follow-up, rebleeds occurred in three patients in three studies with mean follow-up between 3.3 and 14.4 months (0.47%, 95%CI 0.09–1.43%) Conclusion: Woven EndoBridge single-layer is a promising new low-profile device especially for wide-neck bifurcation aneurysms, both ruptured and unruptured. No antiplatelet medication is needed which is a great advantage, especially in ruptured aneurysms. Efficacy and safety compare favorably with (stent-assisted) coiling. However, no direct comparison with other treatments is available as yet.


  • Current Hospital Demographics of Subarachnoid Hemorrhage Based on CT Angiography and 3D Rotational Angiography in a Neurosurgical Center

    by S.B.T. van Rooij, R.S. Bechan, W.J. van Rooij, M.E. Sprengers

    BACKGROUND AND PURPOSE: Aneurysmal subarachnoid hemorrhage is an important cause of mortality and morbidity. Modern hospital demographics are scarce. We evaluated the diagnosis and treatment of patients with SAH in a neurosurgical referral center. MATERIALS AND METHODS: Between March 2013 and April 2015, two hundred eighty-four patients with SAH diagnosed on CT or lumbar puncture were admitted. All patients underwent 64– to 128–detector row CT angiography. Additional imaging was with 3D rotational angiography of all vessels. In patients with aneurysms, characteristics and mode of treatment were recorded. RESULTS: In 197 of 220 patients with an aneurysmal bleeding pattern, we found a cause of the bleeding: One hundred ninety-five patients had a ruptured aneurysm (98%); 1 patient, a micro-AVM; and 1 patient, reversible vasoconstriction syndrome. Of 195 ruptured aneurysms, 6 were dissecting aneurysms and 3 were AVM-associated flow aneurysms. In 23 of 204 patients (11%) with an aneurysmal bleeding pattern and 3D rotational angiography performed, no cause was found. In 8 of 9 patients (89%) with lumbar puncture positive for SAH but CT negative for it, no cause was found. Of 180 patients with a ruptured aneurysm eligible for treatment, 147 (82%) were treated endovascularly and 30 aneurysms (17%) were clipped. Of 204 patients with an aneurysmal bleeding pattern and 3D rotational angiography, 72 (35%) had multiple aneurysms. These 72 patients had, altogether, 117 additional aneurysms, of which 24 (21%) were treated by either coiling or clipping. CONCLUSIONS: This study provides robust data on hospital demographics of SAH in a neurosurgical referral center, based on CTA and 3D rotational angiography of all vessels.


  • Open Access

    The Woven EndoBridge Finally Coming Home across the Atlantic: What to Expect?

    by W.J. van Rooij, S.B.T. van Rooij, H.G. Kortman, J.P. Peluso

    The Woven EndoBridge (WEB; Sequent Medical, Aliso Viejo, California) is an intrasaccular flow diverter primarily developed for wide-neck bifurcation aneurysms without the need for supporting stents and concomitant dual-antiplatelet therapy. The WEB consists of a self-expanding, oblong or spheric


  • The Woven EndoBridge (WEB) as primary treatment for unruptured intracranial aneurysms

    by Sanne Bt van Rooij, Willem Jan van Rooij, Jo P Peluso, Menno Sluzewski

    Purpose: The intrasaccular flow disruptor Woven EndoBridge (WEB) device is developed for the treatment of wide-necked aneurysms without supportive devices. We used the WEB as primary treatment for unruptured aneurysms suitable for the device, regardless of neck size. Methods: Between February 2015 and June 2017, 59 aneurysms in 51 patients were selectively treated with the WEB. There were 15 men and 36 women with a mean age of 59 years. Mean aneurysm size was 7.0 mm (range 3–22 mm). Of 59 aneurysms, 45 (76%) had a wide neck defined as ≥4 mm or dome-neck ratio ≤1.5. No stents or supporting balloons were used. Results: Initial WEB position was judged good in all 59 unruptured aneurysms. One patient with a basilar tip aneurysm had a late thrombotic posterior cerebral artery occlusion by protrusion of the WEB over the artery. There were no procedural ruptures. Overall complication rate was 2.0% (1 of 51, 95% CI 0.01–11.3%). Imaging follow-up was available in 55 of 59 aneurysms (93%). At 3 months, 41 of 57 aneurysms (72%) were completely occluded, 12 (21%) had a neck remnant and 4 (7%) were incompletely occluded. Conclusion: WEB treatment is safe and effective in selected unruptured aneurysms suitable for the device, regardless of neck size or location. There was no need for supportive devices. Three-quarters of all unruptured small aneurysms could be treated with the WEB. In our opinion, the WEB is a valuable alternative to coils, especially in wide-necked aneurysms.


  • Open Access

    The New Low-Profile WEB 17 System for Treatment of Intracranial Aneurysms: First Clinical Experiences

    by S.B.T. van Rooij, J.P. Peluso, M. Sluzewski, H.G. Kortman, W.J. van Rooij

    BACKGROUND AND PURPOSE: The Woven EndoBridge (WEB) is an intrasaccular flow diverter intended to treat wide-neck aneurysms. The latest generation WEBs needed a 0.021-inch microcatheter in the small sizes. Recently, a lower profile range of WEBs compliant with a 0.017-inch microcatheter (WEB 17) has been introduced. We present the first clinical results of treatment of both ruptured and unruptured aneurysms with the WEB 17. MATERIALS AND METHODS: Between December 2016 and September 2017, forty-six aneurysms in 40 patients were treated with the WEB 17. No supporting stents or balloons were used. Twenty-five aneurysms were ruptured (54%). There were 6 men and 34 women (mean age, 62 years; median, 63 years; range, 46–87 years). The mean aneurysm size was 4.9 mm (median, 5 mm; range, 2–7 mm). RESULTS: There were 2 thromboembolic procedural complications without clinical sequelae and no ruptures. The overall permanent procedural complication rate was 0% (0 of 40; 97.5% CI, 0%–10.4%). Imaging follow-up at 3 months was available in 33 patients with 39 aneurysms (97.5% of 40 eligible aneurysms). In 1 aneurysm, the detached WEB was undersized and the remnant was additionally treated with coils after 1 week. This same aneurysm reopened at 3 months and was again treated with a second WEB. One other aneurysm showed persistent WEB filling at 3 months. Complete occlusion was achieved in 28 of 39 aneurysms (72%), and 9 aneurysms (23%) showed a neck remnant. CONCLUSIONS: The WEB 17 is safe and effective for both ruptured and unruptured aneurysms. The WEB 17 is a valuable addition to the existing WEB size range, especially for very small aneurysms.


  • Open Access

    WEB Treatment of Ruptured Intracranial Aneurysms: A Single-Center Cohort of 100 Patients

    by S.B.T. van Rooij, W.J. van Rooij, J.P. Peluso, M. Sluzewski, R.S. Bechan, H.G. Kortman, G.N. Beute, B. van der Pol, C.B. Majoie

    BACKGROUND AND PURPOSE: The Woven EndoBridge device was recently introduced for the intrasaccular treatment of wide-neck aneurysms without the need for adjunctive devices. We present our results of the primary treatment of ruptured aneurysms with the Woven EndoBridge regardless of location or neck size. MATERIALS AND METHODS: Between February 2015 and April 2017, 100 ruptured aneurysms were selectively treated with the Woven EndoBridge. No supporting stents or balloons were used. There were 71 women treated (mean patient age, 59 years; median age, 60 years; range, 23–82 years). RESULTS: The mean aneurysm size was 5.6 mm (range, 3–13 mm), and 42 aneurysms were ≤4 mm. Sixty-six aneurysms (66%) had a wide neck, defined as ≥4 mm or a dome-neck ratio ≤1.5. There was 1 procedural rupture without sequelae. In 9 patients (9%), thromboembolic complications occurred. One poor grade patient died; neurologic deficits remained in 3. Overall treatment-related morbidity-mortality was 4% (4 of 100; 95% CI, 1.2%–10.2%). Two of 100 aneurysms were initially incompletely occluded and were additionally treated early after initial intervention. Of 80 eligible patients, 74 (93%) had 3-month angiographic follow-up. Fifty-four aneurysms (73%) were completely occluded, 17 (23%) had a small neck remnant, and 3 (4%) were incompletely occluded. One patient was additionally treated with a second Woven EndoBridge, and in 2 patients, additional treatment is scheduled. The overall reopening/retreatment rate was 6.8% (5 of 74; 95% CI, 2.6%–15.2%). There were no rebleeds during follow-up. CONCLUSIONS: Treatment of small ruptured aneurysms with the Woven EndoBridge was safe and effective. The Woven EndoBridge proved to be a valuable alternative to coils without the need for stents or balloons.