Sebastian Gomez Jorge
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Sebastian Gomez Jorge has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Claudio Alberto Busada
Universidad Nacional del Sur, Bahía
18 shared publications - Jorge Alberto Solsona
Universidad Nacional del Sur, Bahía
18 shared publications Jorge A. Solsona
9 shared publicationsClaudio A. Busada
8 shared publicationsJorge Solsona
Instituto de Investigaciones en Ingeniera Elctrica (IIIE), Universidad Nacional del Sur (UNS)-CONICET and Dpto. Ing. Elctrica y de Computadoras, Baha Blanca, Argentina
7 shared publications- Gerardo Tapia-Otaegui
Department of Automatic Control and Systems Engineering University of the Basque Country UPV/EHU Donostia Spain ehu.eus
6 shared publications
Latest Publications
- Open Access
A Complex-Valued Feedback Linearization-Based Controller for a Voltage Source Inverter Tied to the Grid via a Second-Order Filter
In this document, a nonlinear control law for a grid-tied converter is introduced. The converter topology consists of a voltage source inverter (VSI) linked to the grid through an inductive-capacitive second-order filter, its input being connected to a capacitive DC-link supplied by a renewable energy-based input power source. In order to achieve good performance in presence of large state excursions caused mainly by substantial set-point modifications and/or considerable disturbances, a nonlinear control law based on a complex-valued feedback linearization strategy is designed. Specifically, a flat output is adopted, which is given by the summation of the energy stored in the DC-link capacitor and in the output filter's inductor and capacitor, as well as by the reactive energy at the output. After linearizing the system through a pertinent coordinate transformation and a nonlinear feedback, a linear trajectory tracking control law is implemented. The performance of the system controlled by applying the proposed strategy is tested via simulation for a very weak grid of unity X/R ratio, yielding satisfactory results.
Open AccessA Complex-Valued Feedback Linearization-Based Controller for a Voltage Source Inverter Tied to the Grid via a Second-Order Filter
In this document, a nonlinear control law for a grid-tied converter is introduced. The converter topology consists of a voltage source inverter (VSI) linked to the grid through an inductive-capacitive second-order filter, its input being connected to a capacitive DC-link supplied by a renewable energy-based input power source. In order to achieve good performance in presence of large state excursions caused mainly by substantial set-point modifications and/or considerable disturbances, a nonlinear control law based on a complex-valued feedback linearization strategy is designed. Specifically, a flat output is adopted, which is given by the summation of the energy stored in the DC-link capacitor and in the output filter's inductor and capacitor, as well as by the reactive energy at the output. After linearizing the system through a pertinent coordinate transformation and a nonlinear feedback, a linear trajectory tracking control law is implemented. The performance of the system controlled by applying the proposed strategy is tested via simulation for a very weak grid of unity X/R ratio, yielding satisfactory results.
- Open Access
- 10 January 2025
- Published by Elsevier in Control Engineering Practice
- Vol. 156
Complex-variable sliding-mode control of non-ideal grid-tied self-synchronized inverter for DC-link capacitance reduction
- 10 January 2025
- Published by Elsevier in Control Engineering Practice
- Vol. 156
Open AccessComplex-variable sliding-mode control of non-ideal grid-tied self-synchronized inverter for DC-link capacitance reduction
- 18 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 39 (4) , 2781-2784
A Nonlinear Observer for Self-Synchronizing Grid-Tied Feeding Inverters
This paper proposes a solution for the self-synchronization of grid-tied feeding inverters. Since the proposed algorithm allows the self-synchronization, it avoids using a voltage sensor for measuring the Point of Common Coupling (PCC) voltage. The algorithm is based on an adaptive non-linear observer that uses the measurement of the output inductor current. Unlike synchronization schemes based on the virtual synchronous generator, which is often used in control strategies based on power synchronization, when combined with a non-linear control strategy, the proposed algorithm allows obtaining an excellent dynamic performance, even in presence of large PCC voltage disturbances and fast varying references. The performance of the proposed observer when combined with a non-linear control strategy, designed by considering the non-linear model of the converter, is illustrated through experimental results.
- 18 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 39 (4) , 2781-2784
A Nonlinear Observer for Self-Synchronizing Grid-Tied Feeding Inverters
This paper proposes a solution for the self-synchronization of grid-tied feeding inverters. Since the proposed algorithm allows the self-synchronization, it avoids using a voltage sensor for measuring the Point of Common Coupling (PCC) voltage. The algorithm is based on an adaptive non-linear observer that uses the measurement of the output inductor current. Unlike synchronization schemes based on the virtual synchronous generator, which is often used in control strategies based on power synchronization, when combined with a non-linear control strategy, the proposed algorithm allows obtaining an excellent dynamic performance, even in presence of large PCC voltage disturbances and fast varying references. The performance of the proposed observer when combined with a non-linear control strategy, designed by considering the non-linear model of the converter, is illustrated through experimental results.
- Open Access
Non-linear Control of the Power Injected Into a Weak Grid by a Self-Synchronized Inverter
In this work, a non-linear controller designed using non-linear transformation linearization and feedback is proposed for an inverter connected to a weak grid through a single-stage inductive filter. The proposed strategy is self-synchronized, so that it is not necessary to have a voltage sensor at the Point of Common Coupling (PCC). The strategy allows to robustify, in the presence of a weak grid, a strategy that has already been demonstrated to allow a significant reduction in the size of the DC-link capacitor of the converter. For this purpose, a state observer is designed that allows estimating the voltage at the PCC from the measurement of the output inductor current. A start-up controller is also included, which allows synchronization even in the case of system start-up. Simulation results are presented for different operating cases, including start-up, normal operation, and grid-voltage sags and swells. In all these cases, it is considered that the exact parameters of the grid to which the inverter is connected are unknown.
Open AccessNon-linear Control of the Power Injected Into a Weak Grid by a Self-Synchronized Inverter
In this work, a non-linear controller designed using non-linear transformation linearization and feedback is proposed for an inverter connected to a weak grid through a single-stage inductive filter. The proposed strategy is self-synchronized, so that it is not necessary to have a voltage sensor at the Point of Common Coupling (PCC). The strategy allows to robustify, in the presence of a weak grid, a strategy that has already been demonstrated to allow a significant reduction in the size of the DC-link capacitor of the converter. For this purpose, a state observer is designed that allows estimating the voltage at the PCC from the measurement of the output inductor current. A start-up controller is also included, which allows synchronization even in the case of system start-up. Simulation results are presented for different operating cases, including start-up, normal operation, and grid-voltage sags and swells. In all these cases, it is considered that the exact parameters of the grid to which the inverter is connected are unknown.
- 19 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (12) , 15870-15879
Exact Linearization Control of a Two-Stage DC–AC Converter With a Power Pulsating Buffer
This paper proposes to combine full feedback linearization with full state feedback and trajectory tracking control in order to obtain a high performance dc-ac boost converter. The system is composed of a boost converter, an inverter and a power pulsation buffer, which removes the ripple from the dc-link, and allows reducing the size of its capacitor. This can improve the reliability of the system, as smaller capacitors do not need to be electrolytic. The use of full feedback linearization enables a stable controller at any point of operation, while the trajectory tracking control allows high performance tracking of the references (required for smaller capacitor values). The steady state performance and disturbance rejection capabilities are provided by the full state feedback control. Additionally, the effect of parametric mismatches is analyzed, and the robustness of the proposal is validated through simulations and experimental results
- 19 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (12) , 15870-15879
Exact Linearization Control of a Two-Stage DC–AC Converter With a Power Pulsating Buffer
This paper proposes to combine full feedback linearization with full state feedback and trajectory tracking control in order to obtain a high performance dc-ac boost converter. The system is composed of a boost converter, an inverter and a power pulsation buffer, which removes the ripple from the dc-link, and allows reducing the size of its capacitor. This can improve the reliability of the system, as smaller capacitors do not need to be electrolytic. The use of full feedback linearization enables a stable controller at any point of operation, while the trajectory tracking control allows high performance tracking of the references (required for smaller capacitor values). The steady state performance and disturbance rejection capabilities are provided by the full state feedback control. Additionally, the effect of parametric mismatches is analyzed, and the robustness of the proposal is validated through simulations and experimental results
- 22 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (4) , 3233-3241
Current-Controlled Synchronverter: A Grid Fault Tolerant Grid Forming Inverter
A synchronverter (SV) equipped with an output admittance synthesizer is modified to avoid the usual transient instability of grid forming inverters in presence large grid disturbances, keeping the injected currents at safe values. The proposal consists of changing the control objective of the SV: instead of controlling the injected active and reactive powers, the injected active and reactive currents are controlled (as in a grid following inverter). The resulting system [called here current controlled SV, (CCSV)], injects balanced currents, even against asymmetric faults. The CCSV is capable of operating both in island mode and in grid connected mode, and can switch between these modes without prior synchronization. Like the SV, the CCSV does not use a dedicated algorithm for synchronization (such as a phase-locked loop).
- 22 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (4) , 3233-3241
Current-Controlled Synchronverter: A Grid Fault Tolerant Grid Forming Inverter
A synchronverter (SV) equipped with an output admittance synthesizer is modified to avoid the usual transient instability of grid forming inverters in presence large grid disturbances, keeping the injected currents at safe values. The proposal consists of changing the control objective of the SV: instead of controlling the injected active and reactive powers, the injected active and reactive currents are controlled (as in a grid following inverter). The resulting system [called here current controlled SV, (CCSV)], injects balanced currents, even against asymmetric faults. The CCSV is capable of operating both in island mode and in grid connected mode, and can switch between these modes without prior synchronization. Like the SV, the CCSV does not use a dedicated algorithm for synchronization (such as a phase-locked loop).
- 1 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (3) , 2157-2166
Nonlinear Controller Allowing the Use of a Small-Size DC-Link Capacitor in Grid-Feeding Converters
In this article, we propose an instantaneous complex power control (ICPC) for a grid-tied voltage-source converter, which has two important features: it allows injecting currents with low distortion to the grid, and it allows to significantly reduce the value of the dc link capacitor, which can potentially increase the reliability of the system and decrease its cost (considering different capacitor technologies). The proposal is based on finding the exact active power reference that the controller requires to keep the mean value of the energy in the dc link constant at all times. This means that, even when the loading conditions change, the mean value of the dc link voltage remains unchanged, allowing the reduction of the value of dc link capacitor. The proposed control scheme is validated both through simulations and experimental results.
- 1 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (3) , 2157-2166
Nonlinear Controller Allowing the Use of a Small-Size DC-Link Capacitor in Grid-Feeding Converters
In this article, we propose an instantaneous complex power control (ICPC) for a grid-tied voltage-source converter, which has two important features: it allows injecting currents with low distortion to the grid, and it allows to significantly reduce the value of the dc link capacitor, which can potentially increase the reliability of the system and decrease its cost (considering different capacitor technologies). The proposal is based on finding the exact active power reference that the controller requires to keep the mean value of the energy in the dc link constant at all times. This means that, even when the loading conditions change, the mean value of the dc link voltage remains unchanged, allowing the reduction of the value of dc link capacitor. The proposed control scheme is validated both through simulations and experimental results.
- 13 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (2) , 1125-1134
Model-Matching Control for Low Switching Frequency Converters Unifying Different Performance Requirements
This article presents an active damping control for inductor—capacitor—inductor-filtered grid-connected converters to meet strict grid codes and power quality standards. The control strategy allows unifying into a single design procedure different requirements demanded by system operators. A model-matching approach is used to set the reference tracking and disturbance rejection transfer functions separately, which provides an additional degree of freedom to the converter control design. On the other hand, the measurement stage and digital implementation effects are considered in the control design to maximize the control bandwidth. The proposed control strategy uses a reduced number of sensors and is able to compensate unbalanced and distorted grid voltage conditions; it presents a systematic design and is formulated in the discrete-time domain, enabling a direct digital implementation. Performance assessment and comparison of different control strategies are performed using eigenvalue and transient response analyzes. The effectiveness and advantages of the proposed strategy are validated through an experimental setup.
- 13 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (2) , 1125-1134
Model-Matching Control for Low Switching Frequency Converters Unifying Different Performance Requirements
This article presents an active damping control for inductor—capacitor—inductor-filtered grid-connected converters to meet strict grid codes and power quality standards. The control strategy allows unifying into a single design procedure different requirements demanded by system operators. A model-matching approach is used to set the reference tracking and disturbance rejection transfer functions separately, which provides an additional degree of freedom to the converter control design. On the other hand, the measurement stage and digital implementation effects are considered in the control design to maximize the control bandwidth. The proposed control strategy uses a reduced number of sensors and is able to compensate unbalanced and distorted grid voltage conditions; it presents a systematic design and is formulated in the discrete-time domain, enabling a direct digital implementation. Performance assessment and comparison of different control strategies are performed using eigenvalue and transient response analyzes. The effectiveness and advantages of the proposed strategy are validated through an experimental setup.