Norio Saito
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Norio Saito has a total of 536 co-authors. Here are the top co-authors by number of shared publications:
- Kiyoshi Ueda
Institute of Atomic and Molecular Physics and Jilin Provincial Key Laboratory of Applied Atomic and Molecular Spectroscopy, Jilin University, Changchun, China
36 shared publications Isao H. Suzuki
Photon Factory, Institute of Material Structure Science, Oho 1-1, Tsukuba 980-0801, Japan
34 shared publications- Yusuke Tamenori
Japan Synchrotron Radiation Research Institute, Sayo, Japan
32 shared publications - Yuichiro Morishita
National Metrology Institute of Japan, AIST, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 Japan
30 shared publications - Makina Yabashi
Japan Synchrotron Radiation Research Institute
28 shared publications K Ueda
RIKEN SPring-8 Center, Hyogo 679-5148, Japan
24 shared publications
Latest Publications
- 1 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-8
Subfemtoampere Resolved Ionization Current Measurements Using a High-Resistance Transimpedance Amplifier
In low-dose-rate dosimetry using ionization chambers, the predominant component in the uncertainty budget is a measurement uncertainty of current at a measurement range of around 10 fA. To improve this, in this article, we report on the development of a system for measuring a small ionization current based on a transimpedance amplifier utilizing a high-resistance feedback resistor. In this amplifier, we used a feedback resistor of 1 $\text{T}\Omega $ made of a metalized glaze thick film, which has clear traceability to a resistance standard. In addition, the nonlinear current-to-voltage profile of the feedback resistor and its contribution to the measurement uncertainty were carefully evaluated. Type-A uncertainty well below 1 fA can be achieved within a practical measurement time shorter than an hour. As a result, current measurements with relative expanded uncertainty from 0.1 % to 2 % were demonstrated for the ionization currents ranging from sub-fA to sub-pA generated by a 137 Cs gamma-ray source. This transimpedance amplifier with high-resistance feedback is appropriate for low-dose-rate radiation dosimetry needed for medical and environmental monitoring applications.
- 1 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-8
Subfemtoampere Resolved Ionization Current Measurements Using a High-Resistance Transimpedance Amplifier
In low-dose-rate dosimetry using ionization chambers, the predominant component in the uncertainty budget is a measurement uncertainty of current at a measurement range of around 10 fA. To improve this, in this article, we report on the development of a system for measuring a small ionization current based on a transimpedance amplifier utilizing a high-resistance feedback resistor. In this amplifier, we used a feedback resistor of 1 $\text{T}\Omega $ made of a metalized glaze thick film, which has clear traceability to a resistance standard. In addition, the nonlinear current-to-voltage profile of the feedback resistor and its contribution to the measurement uncertainty were carefully evaluated. Type-A uncertainty well below 1 fA can be achieved within a practical measurement time shorter than an hour. As a result, current measurements with relative expanded uncertainty from 0.1 % to 2 % were demonstrated for the ionization currents ranging from sub-fA to sub-pA generated by a 137 Cs gamma-ray source. This transimpedance amplifier with high-resistance feedback is appropriate for low-dose-rate radiation dosimetry needed for medical and environmental monitoring applications.
- Open Access
- 1 January 2021
- Published by IOP Publishing in Journal of Physics Communications
- Vol. 5 (1) , 015014
Surface plasma resonance in Xe clusters studied by EUV pump-NIR probe experiments
The ionization dynamics of Xe cluster was analyzed by extreme ultraviolet (EUV) pump-near infrared (NIR) probe experiments. The experiments were carried out for Xe clusters containing around 5000 atoms on average at the SPring-8 Compact SASE Source (SCSS) test accelerator in Japan. We recorded ion spectra emitted from Xe clusters as a function of the time delay between the EUV and NIR pulses. The ion yields up to highly-charged states were substantially enhanced when Xe clusters excited by the EUV pulses were illuminated by the NIR laser pulses at 1 to 2 ps after the pump pulse, providing a compelling evidence for nano-plasma formation and subsequent NIR absorption via surface plasma resonance. We also observed emergence of low kinetic energy Xe+ at long time delay, which can be attributed to the ionization of excited neutral atoms resulting from the electron-ion recombination in the expanding nano-plasma.
- 1 January 2021
- Published by IOP Publishing in Journal of Physics Communications
- Vol. 5 (1) , 015014
Open AccessSurface plasma resonance in Xe clusters studied by EUV pump-NIR probe experiments
The ionization dynamics of Xe cluster was analyzed by extreme ultraviolet (EUV) pump-near infrared (NIR) probe experiments. The experiments were carried out for Xe clusters containing around 5000 atoms on average at the SPring-8 Compact SASE Source (SCSS) test accelerator in Japan. We recorded ion spectra emitted from Xe clusters as a function of the time delay between the EUV and NIR pulses. The ion yields up to highly-charged states were substantially enhanced when Xe clusters excited by the EUV pulses were illuminated by the NIR laser pulses at 1 to 2 ps after the pump pulse, providing a compelling evidence for nano-plasma formation and subsequent NIR absorption via surface plasma resonance. We also observed emergence of low kinetic energy Xe+ at long time delay, which can be attributed to the ionization of excited neutral atoms resulting from the electron-ion recombination in the expanding nano-plasma.
- Open Access
- 9 September 2019
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 151 (10) , 104302
Probing gaseous molecular structure by molecular-frame photoelectron angular distributions
Carbon 1s photoelectron angular distributions of an iodomethane molecule were measured relative to the recoil-frame determined by the momentum correlation between I+ and at photoelectron energies of 3, 6.1, and 12 eV. The energy dependent behavior of the recoil-frame photoelectron angular distributions is reproduced reasonably well by the time-dependent density functional theory with B-spline methods. We discuss potential applications of the fully differential photoelectron angular distribution measurements in the molecular frame to three-dimensional molecular structural determinations identifying the directions and lengths of the bonds.- 9 September 2019
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 151 (10) , 104302
Open AccessProbing gaseous molecular structure by molecular-frame photoelectron angular distributions
Carbon 1s photoelectron angular distributions of an iodomethane molecule were measured relative to the recoil-frame determined by the momentum correlation between I+ and at photoelectron energies of 3, 6.1, and 12 eV. The energy dependent behavior of the recoil-frame photoelectron angular distributions is reproduced reasonably well by the time-dependent density functional theory with B-spline methods. We discuss potential applications of the fully differential photoelectron angular distribution measurements in the molecular frame to three-dimensional molecular structural determinations identifying the directions and lengths of the bonds. - 7 May 2019
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 150 (17) , 174306
Probing molecular bond-length using molecular-frame photoelectron angular distributions
The molecular-frame photoelectron angular distributions (MFPADs) in O 1s photoemission from CO2 molecule were measured. Patterns due to photoelectron diffractions were observed in the MFPADs. The polarization-averaged MFPADs were compared with theoretical calculation and were found to be useful in determining the molecular bond-length, which is a component to determine molecular structures.
- 7 May 2019
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 150 (17) , 174306
Probing molecular bond-length using molecular-frame photoelectron angular distributions
The molecular-frame photoelectron angular distributions (MFPADs) in O 1s photoemission from CO2 molecule were measured. Patterns due to photoelectron diffractions were observed in the MFPADs. The polarization-averaged MFPADs were compared with theoretical calculation and were found to be useful in determining the molecular bond-length, which is a component to determine molecular structures.
- 1 June 2018
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 894, 107-110
Absolute laser-intensity measurement and online monitor calibration using a calorimeter at a soft X-ray free-electron laser beamline in SACLA
- 1 June 2018
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 894, 107-110
Absolute laser-intensity measurement and online monitor calibration using a calorimeter at a soft X-ray free-electron laser beamline in SACLA
- 30 May 2018
- Published by Springer Nature in IFMBE Proceedings
- p. 565-569
Feasibility Study of Alanine Dosimeter for Carbon-Beam Dosimetry
- 30 May 2018
- Published by Springer Nature in IFMBE Proceedings
- p. 565-569
Feasibility Study of Alanine Dosimeter for Carbon-Beam Dosimetry
- 15 November 2017
- Published by Optica Publishing Group in Optics Letters
- Vol. 42 (22) , 4776-4779
Compact bolometric radiometer for free-electron lasers in a wavelength range from extreme-ultraviolet to x-rays
A reliable diagnostic device for free-electron lasers (FELs) is essential for both users and the evaluation of FEL sources and beamline optics. Here, we propose a compact bolometric radiometer (CBR) that can operate at room temperature. The CBR is mainly designed for FELs in the wavelength range from the extreme-ultraviolet (EUV) to x-rays; moreover, we confirmed that the proposed device can also be applied to synchrotron radiation. As an application of the CBR, we evaluated an FEL beamline transmission by means of bolometric technique in the EUV range for the first time, to the best of our knowledge. This indicates that the CBR is an effective diagnostic device for FELs.
- 15 November 2017
- Published by Optica Publishing Group in Optics Letters
- Vol. 42 (22) , 4776-4779
Compact bolometric radiometer for free-electron lasers in a wavelength range from extreme-ultraviolet to x-rays
A reliable diagnostic device for free-electron lasers (FELs) is essential for both users and the evaluation of FEL sources and beamline optics. Here, we propose a compact bolometric radiometer (CBR) that can operate at room temperature. The CBR is mainly designed for FELs in the wavelength range from the extreme-ultraviolet (EUV) to x-rays; moreover, we confirmed that the proposed device can also be applied to synchrotron radiation. As an application of the CBR, we evaluated an FEL beamline transmission by means of bolometric technique in the EUV range for the first time, to the best of our knowledge. This indicates that the CBR is an effective diagnostic device for FELs.
- 1 October 2017
- Published by Elsevier in Journal of Electron Spectroscopy and Related Phenomena
- Vol. 220, 3-5
An accumulation mode of a room-temperature calorimeter for total pulse energy measurement of X-ray FELs
- 1 October 2017
- Published by Elsevier in Journal of Electron Spectroscopy and Related Phenomena
- Vol. 220, 3-5
An accumulation mode of a room-temperature calorimeter for total pulse energy measurement of X-ray FELs
- 15 July 2017
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 178 (2) , 235-241
COMPARISON OF PERSONAL DOSE EQUIVALENT Hp(10) IN 137CS RADIATION BETWEEN THE PRIMARY STANDARDS LABORATORIES OF JAPAN AND AUSTRALIA USING BeO OSL PERSONAL DOSEMETERS
A comparison of personal dose equivalent Hp(10) for 137Cs radiation was conducted between the primary standards laboratories of Japan and Australia. A set of 120 commercially available passive BeO OSL dosemeters were used (Dosimetrics GmbH, Munich). The aim was to investigate the precision which could be obtained with this technique, and to confirm the personal dose equivalent delivery methods in each standards laboratory. A dose of 5 mSv was delivered to 40 dosemeters in each country, and 40 dosemeters were used as controls. The result of the comparison was a ratio of Hp(10) in Japan to Australia of 1.006 with a combined standard uncertainty of 3.2%. The statistical uncertainty was 0.32% indicating that passive dosemeters can be used for comparisons of high precision.
- 15 July 2017
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 178 (2) , 235-241
COMPARISON OF PERSONAL DOSE EQUIVALENT Hp(10) IN 137CS RADIATION BETWEEN THE PRIMARY STANDARDS LABORATORIES OF JAPAN AND AUSTRALIA USING BeO OSL PERSONAL DOSEMETERS
A comparison of personal dose equivalent Hp(10) for 137Cs radiation was conducted between the primary standards laboratories of Japan and Australia. A set of 120 commercially available passive BeO OSL dosemeters were used (Dosimetrics GmbH, Munich). The aim was to investigate the precision which could be obtained with this technique, and to confirm the personal dose equivalent delivery methods in each standards laboratory. A dose of 5 mSv was delivered to 40 dosemeters in each country, and 40 dosemeters were used as controls. The result of the comparison was a ratio of Hp(10) in Japan to Australia of 1.006 with a combined standard uncertainty of 3.2%. The statistical uncertainty was 0.32% indicating that passive dosemeters can be used for comparisons of high precision.
- Open Access
- 1 July 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 875 (4) , 032004
Evidence for Efficient Pathway to Produce Slow Electrons by Ground-state Dication in Clusters
We present an experimental evidence for a so-far unobserved, but potentially very important step relaxation cascades following inner-shell ionization of a composite system: Multiply charged ionic states created after Auger decay may be neutralized by electron transfer from a neighboring species, producing at the same time a low-energy free electron. This electron transfer-mediated decay (ETMD) called process is effective even after Auger decay into the dicationic ground state. Here, we report the ETMD of Ne2+ produced after Ne 1s photoionization in Ne–Kr mixed clusters.
- 1 July 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 875 (4) , 032004
Open AccessEvidence for Efficient Pathway to Produce Slow Electrons by Ground-state Dication in Clusters
We present an experimental evidence for a so-far unobserved, but potentially very important step relaxation cascades following inner-shell ionization of a composite system: Multiply charged ionic states created after Auger decay may be neutralized by electron transfer from a neighboring species, producing at the same time a low-energy free electron. This electron transfer-mediated decay (ETMD) called process is effective even after Auger decay into the dicationic ground state. Here, we report the ETMD of Ne2+ produced after Ne 1s photoionization in Ne–Kr mixed clusters.