Lion Augel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lion Augel has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
I. A. Fischer
8 shared publicationsJ. Schulze
8 shared publicationsJörg Schulze
Institute of Semiconductor Engineering, University of Stuttgart 2 , Stuttgart 70569, Germany
6 shared publicationsS. Bechler
5 shared publications- Audrey Berrier
Physikalisches Institut and Research Center SCoPE, Universität Stuttgart , Pfaffenwaldring 57, 70550 Stuttgart, Germany
4 shared publications Inga Anita Fischer
BTU Cottbus-Senftenberg, Germany
4 shared publications
Latest Publications
- Open Access
- 1 February 2026
- Published by AIP Publishing in APL Photonics
- Vol. 11 (2)
Integration of nanophotonic structures with optoelectronic devices on the Si platform
Light–matter interaction in nanostructures and the integration of optical and electro-optical technologies on the Si platform are research fields that receive strong and growing attention and that are relevant for a broad range of application areas, from imaging to quantum computation. Here, we put a focus on their intersection with the discussion of device concepts, challenges, and opportunities for the integration of nanophotonic structures into optoelectronic devices on the Si platform. The incorporation, in particular, of metasurfaces into optoelectronic devices offers unique possibilities not only for adding device functionality and improving efficiency at the same time but also for material integration, provided that the challenges associated with device integration can be addressed.
- 1 February 2026
- Published by AIP Publishing in APL Photonics
- Vol. 11 (2)
Open AccessIntegration of nanophotonic structures with optoelectronic devices on the Si platform
Light–matter interaction in nanostructures and the integration of optical and electro-optical technologies on the Si platform are research fields that receive strong and growing attention and that are relevant for a broad range of application areas, from imaging to quantum computation. Here, we put a focus on their intersection with the discussion of device concepts, challenges, and opportunities for the integration of nanophotonic structures into optoelectronic devices on the Si platform. The incorporation, in particular, of metasurfaces into optoelectronic devices offers unique possibilities not only for adding device functionality and improving efficiency at the same time but also for material integration, provided that the challenges associated with device integration can be addressed.
- Open Access
- 24 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 14 (3) , 1-8
Optimization of Fully Integrated Al Nanohole Array-Based Refractive Index Sensors for Use With a LED Light Source
Plasmonic nanohole arrays that are directly structured into the top metallization of vertical Ge-on-Si PIN photodiodes can be used to sense refractive index changes. This concept can pave the way to fully integrated biosensors with small footprint and high sensitivities. Here, we show that by optimizing the layer structure of the Ge-on-Si PIN photodiode as well as the geometry of the nanohole arrays, we can achieve high and narrow optical responsivity peaks with Fano-resonance lineshapes. We used an iterative, simulation-based approach in order to optimize the photodiode layer structure as well as the nanohole geometry and compared the predictions to measurement results obtained from fabricated devices. Our fabricated device shows large peak shifts upon changes in the superstrate refractive index. Finally, we argue that the improved device setup can have potential applications in a sensor system that uses an LED light source and estimate the limit of detection to be $2.2\cdot 10^{-5}$ RIU- 24 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 14 (3) , 1-8
Open AccessOptimization of Fully Integrated Al Nanohole Array-Based Refractive Index Sensors for Use With a LED Light Source
Plasmonic nanohole arrays that are directly structured into the top metallization of vertical Ge-on-Si PIN photodiodes can be used to sense refractive index changes. This concept can pave the way to fully integrated biosensors with small footprint and high sensitivities. Here, we show that by optimizing the layer structure of the Ge-on-Si PIN photodiode as well as the geometry of the nanohole arrays, we can achieve high and narrow optical responsivity peaks with Fano-resonance lineshapes. We used an iterative, simulation-based approach in order to optimize the photodiode layer structure as well as the nanohole geometry and compared the predictions to measurement results obtained from fabricated devices. Our fabricated device shows large peak shifts upon changes in the superstrate refractive index. Finally, we argue that the improved device setup can have potential applications in a sensor system that uses an LED light source and estimate the limit of detection to be $2.2\cdot 10^{-5}$ RIU - 2 July 2020
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 128 (1) , 013105
Comparing Fourier transform infrared spectroscopy results with photocurrent measurements for Ge-on-Si PIN photodetectors with and without Al nanoantennas
Plasmonic and nanophotonic structures have been used to enhance the performance of photonic devices through the control and manipulation of photonic energy. Characterization of such devices typically requires the fabrication of contacting structures followed by stepwise spectral illumination and data recording. The acquisition of reflectance and transmittance spectra with Fourier transform infrared spectroscopy (FTIR) is—in contrast—a contactless and faster process. Since FTIR measurements take into account substrate absorption, which does not contribute to photocurrent, the two measurement approaches cannot be compared without further data processing. Here, we present a strategy to separate substrate absorption from absorption processes within the device layers in order to predict device performance from FTIR measurements. We apply our strategy to Ge-on-Si planar photodetectors with and without plasmonic structures.
- 2 July 2020
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 128 (1) , 013105
Comparing Fourier transform infrared spectroscopy results with photocurrent measurements for Ge-on-Si PIN photodetectors with and without Al nanoantennas
Plasmonic and nanophotonic structures have been used to enhance the performance of photonic devices through the control and manipulation of photonic energy. Characterization of such devices typically requires the fabrication of contacting structures followed by stepwise spectral illumination and data recording. The acquisition of reflectance and transmittance spectra with Fourier transform infrared spectroscopy (FTIR) is—in contrast—a contactless and faster process. Since FTIR measurements take into account substrate absorption, which does not contribute to photocurrent, the two measurement approaches cannot be compared without further data processing. Here, we present a strategy to separate substrate absorption from absorption processes within the device layers in order to predict device performance from FTIR measurements. We apply our strategy to Ge-on-Si planar photodetectors with and without plasmonic structures.
- 22 October 2019
- Published by The Electrochemical Society in ECS Transactions
- Vol. 93 (1) , 41-44
Plasmonics-Integrated Ge PIN-Photodetectors
Refractive index sensors can be designed for high sensitivities at small device foot-print. Using a complementary metal-oxide-semiconductor compatible process for fabrication paves the way to cheap devices enabling integrated biosensors. We present results on combining vertical Ge PIN photodetectors with metallic nanostructures such as Al nanohole arrays placed directly on top of the diode. The interaction of plasmonic resonances and photonic modes such as waveguide modes or optical modes in nanostructured photodetectors can potentially be exploited to design refractive index sensors with very high sensitivities. We discuss how the interplay of material properties and device geometry can be tailored for applications in integrated biosensing.
- 22 October 2019
- Published by The Electrochemical Society in ECS Transactions
- Vol. 93 (1) , 41-44
Plasmonics-Integrated Ge PIN-Photodetectors
Refractive index sensors can be designed for high sensitivities at small device foot-print. Using a complementary metal-oxide-semiconductor compatible process for fabrication paves the way to cheap devices enabling integrated biosensors. We present results on combining vertical Ge PIN photodetectors with metallic nanostructures such as Al nanohole arrays placed directly on top of the diode. The interaction of plasmonic resonances and photonic modes such as waveguide modes or optical modes in nanostructured photodetectors can potentially be exploited to design refractive index sensors with very high sensitivities. We discuss how the interplay of material properties and device geometry can be tailored for applications in integrated biosensing.
- Open Access
Optofluidic sensor system with Ge PIN photodetector for CMOS-compatible sensing
Vertical optofluidic biosensors based on refractive index sensing promise highest sensitivities at smallest area foot-print. Nevertheless, when it comes to large scale fabrication and application of such sensors, cheap and robust platforms for sample preparation and supply are needed - not to mention the expected ease of use in application. We present an optofluidic sensor system using a cyclic olefin copolymer microfluidic chip as carrier and feeding supply for a complementary metal-oxide-semiconductor-compatibly fabricated Ge PIN photodetector. Whereas typically only passive components of a sensor are located within the microfluidic channel, here the active device is directly exposed to the fluid, enabling top-illumination. The capability for detecting different refractive indices was verified by different fluids with subsequent recording of the optical responsivity. All components excel in their capability to be transferred to large scale fabrication and further integration of microfluidic and sensing systems. The photodetector itself is intended to serve as a platform for further sophisticated collinear sensing approaches.
Open AccessOptofluidic sensor system with Ge PIN photodetector for CMOS-compatible sensing
Vertical optofluidic biosensors based on refractive index sensing promise highest sensitivities at smallest area foot-print. Nevertheless, when it comes to large scale fabrication and application of such sensors, cheap and robust platforms for sample preparation and supply are needed - not to mention the expected ease of use in application. We present an optofluidic sensor system using a cyclic olefin copolymer microfluidic chip as carrier and feeding supply for a complementary metal-oxide-semiconductor-compatibly fabricated Ge PIN photodetector. Whereas typically only passive components of a sensor are located within the microfluidic channel, here the active device is directly exposed to the fluid, enabling top-illumination. The capability for detecting different refractive indices was verified by different fluids with subsequent recording of the optical responsivity. All components excel in their capability to be transferred to large scale fabrication and further integration of microfluidic and sensing systems. The photodetector itself is intended to serve as a platform for further sophisticated collinear sensing approaches.
- 29 October 2018
- Published by American Chemical Society (ACS) in ACS Photonics
- Vol. 5 (11) , 4586-4593
Integrated Collinear Refractive Index Sensor with Ge PIN Photodiodes
- 29 October 2018
- Published by American Chemical Society (ACS) in ACS Photonics
- Vol. 5 (11) , 4586-4593
Integrated Collinear Refractive Index Sensor with Ge PIN Photodiodes
- 8 May 2018
- Published by IOP Publishing in Semiconductor Science and Technology
- Vol. 33 (6) , 065008
Ex situ n + doping of GeSn alloys via non-equilibrium processing
Full integration of Ge-based alloys like GeSn with complementary-metal-oxide-semiconductor technology would require the fabrication of p- and n-type doped regions for both planar and tri-dimensional device architectures which is challenging using in situ doping techniques. In this work, we report on the influence of ex situ doping on the structural, electrical and optical properties of GeSn alloys. n-type doping is realized by P implantation into GeSn alloy layers grown by molecular beam epitaxy (MBE) followed by flash lamp annealing. We show that effective carrier concentration of up to 1 × 10 19 cm −3 can be achieved without affecting the Sn distribution. Sn segregation at the surface accompanied with an Sn diffusion towards the crystalline/amorphous GeSn interface is found at P fluences higher than 3 × 10 15 cm −2 and electron concentration of about 4 × 10 19 cm −3 . The optical and structural properties of ion-implanted GeSn layers are comparable with the in situ doped MBE grown layers.
- 8 May 2018
- Published by IOP Publishing in Semiconductor Science and Technology
- Vol. 33 (6) , 065008
Ex situ n + doping of GeSn alloys via non-equilibrium processing
Full integration of Ge-based alloys like GeSn with complementary-metal-oxide-semiconductor technology would require the fabrication of p- and n-type doped regions for both planar and tri-dimensional device architectures which is challenging using in situ doping techniques. In this work, we report on the influence of ex situ doping on the structural, electrical and optical properties of GeSn alloys. n-type doping is realized by P implantation into GeSn alloy layers grown by molecular beam epitaxy (MBE) followed by flash lamp annealing. We show that effective carrier concentration of up to 1 × 10 19 cm −3 can be achieved without affecting the Sn distribution. Sn segregation at the surface accompanied with an Sn diffusion towards the crystalline/amorphous GeSn interface is found at P fluences higher than 3 × 10 15 cm −2 and electron concentration of about 4 × 10 19 cm −3 . The optical and structural properties of ion-implanted GeSn layers are comparable with the in situ doped MBE grown layers.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 40.5.1-40.5.4
An integrated plasmonic refractive index sensor: Al nanohole arrays on Ge PIN photodiodes
Collinear refractive index sensors offer highest sensitivities at smallest device foot-print. Using a complementary metal-oxide-semiconductor compatible process for fabrication paves the way to cheap devices enabling integrated biosensors. We present a vertical Ge PIN photodiode equipped with Al nanohole arrays placed directly on top of the diode. The interaction of plasmonic resonances and thin-film reflection within the PIN layer stack enables sensitivities comparable to Au sensing systems showing FOM* up to 14.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 40.5.1-40.5.4
An integrated plasmonic refractive index sensor: Al nanohole arrays on Ge PIN photodiodes
Collinear refractive index sensors offer highest sensitivities at smallest device foot-print. Using a complementary metal-oxide-semiconductor compatible process for fabrication paves the way to cheap devices enabling integrated biosensors. We present a vertical Ge PIN photodiode equipped with Al nanohole arrays placed directly on top of the diode. The interaction of plasmonic resonances and thin-film reflection within the PIN layer stack enables sensitivities comparable to Au sensing systems showing FOM* up to 14.