Wolfgang Schiller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wolfgang Schiller has a total of 241 co-authors. Here are the top co-authors by number of shared publications:
Armin Welz
Department of Cardiac Surgery, University of Bonn, Bonn, Germany
24 shared publicationsFritz Mellert
From the Medizinische Klinik und Poliklinik II, Universitätsklinikum Bonn, Rheinische Friedrich-Wilhelms-Universität Bonn, Germany (A.S., N.N., J.-M.S., C.H., E.G., G.N., N.W.); Medizinische Klinik und Poliklinik II, Sektion Angiologie, Universitätsklinikum Bonn, Rheinische Friedrich-Wilhelms-Universität Bonn, Germany (N.S., S.P., C.S.); and Klinik für Herzchirurgie, Universitätsklinikum Bonn, Rheinische Friedrich-Wilhelms-Universität Bonn, Germany (F.M., W.S., A.W.).
14 shared publicationsGeorg Nickenig
From the Medizinische Klinik und Poliklinik II, Universitätsklinikum Bonn, Rheinische Friedrich-Wilhelms-Universität Bonn, Germany (A.S., N.N., J.-M.S., C.H., E.G., G.N., N.W.); Medizinische Klinik und Poliklinik II, Sektion Angiologie, Universitätsklinikum Bonn, Rheinische Friedrich-Wilhelms-Universität Bonn, Germany (N.S., S.P., C.S.); and Klinik für Herzchirurgie, Universitätsklinikum Bonn, Rheinische Friedrich-Wilhelms-Universität Bonn, Germany (F.M., W.S., A.W.).
12 shared publicationsChris Probst
Department of Cardiac Surgery, University of Bonn, Bonn, Germany
11 shared publicationsA. Welz
Klinik und Poliklinik für Herzchirurgie, Universität Bonn, Bonn, Germany
9 shared publicationsAndreas Beckmann
Department of Cardiac and Vascular Surgery, Heart Center Duisburg, Duisburg, Germany
8 shared publications
Latest Publications
- Open Access
- 12 February 2024
- Published by Springer Nature in Journal of Thrombosis and Thrombolysis
- Vol. 57 (3) , 512-519
Blood group AB is associated with reduced blood loss but also elevated cardiovascular mortality in aortocoronary bypass surgery
Patient blood group (BG) is predictive for von-Willebrand-factor (VWF) and Factor VIII variation. The clinical impact of this ABO-effect on blood loss, cardiovascular complications and outcome has been described for several patient cohorts. The aim of this study was to investigate the impact of patient BG on blood loss and outcome after coronary artery bypass surgery (CABG). Patient records, intraoperative data and perioperative transfusion records of 5713 patients receiving an on-pump CABG procedure between 05/2004 and 12/2018 were analyzed. A logistic regression model for death due to perioperative myocardial ischaemia (PMI) was developed from initially 24 variables by using an univariate and multivariate selection process. BG AB patients required less blood transfusions as compared to the other blood groups, especially in case of emergency operations. However, BG AB patients also had a higher mortality which was due to secondary cardiovascular complications. The impact of blood type on the rate of cardiovascular mortality was confirmed in the logistic regression model. BG AB patients have a worse outcome after CABG surgery due to an increased incidence of fatal cardiovascular complications. As perioperative myocardial ischemia due to graft occlusion appears to be the most likely explanation, stricter anticoagulation for BG AB patients should be discussed.
- 12 February 2024
- Published by Springer Nature in Journal of Thrombosis and Thrombolysis
- Vol. 57 (3) , 512-519
Open AccessBlood group AB is associated with reduced blood loss but also elevated cardiovascular mortality in aortocoronary bypass surgery
Patient blood group (BG) is predictive for von-Willebrand-factor (VWF) and Factor VIII variation. The clinical impact of this ABO-effect on blood loss, cardiovascular complications and outcome has been described for several patient cohorts. The aim of this study was to investigate the impact of patient BG on blood loss and outcome after coronary artery bypass surgery (CABG). Patient records, intraoperative data and perioperative transfusion records of 5713 patients receiving an on-pump CABG procedure between 05/2004 and 12/2018 were analyzed. A logistic regression model for death due to perioperative myocardial ischaemia (PMI) was developed from initially 24 variables by using an univariate and multivariate selection process. BG AB patients required less blood transfusions as compared to the other blood groups, especially in case of emergency operations. However, BG AB patients also had a higher mortality which was due to secondary cardiovascular complications. The impact of blood type on the rate of cardiovascular mortality was confirmed in the logistic regression model. BG AB patients have a worse outcome after CABG surgery due to an increased incidence of fatal cardiovascular complications. As perioperative myocardial ischemia due to graft occlusion appears to be the most likely explanation, stricter anticoagulation for BG AB patients should be discussed.
- 1 March 2022
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 31 (3) , 407-414
Comparison of Perioperative High-Sensitive Troponin T and Troponin I Assays in Cardiac Surgery
- 1 March 2022
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 31 (3) , 407-414
Comparison of Perioperative High-Sensitive Troponin T and Troponin I Assays in Cardiac Surgery
- 1 April 2018
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 66 (3) , 206-214
Dilatation of Vascular Prostheses in Ascending Aortic Position: A Long-Term Follow-Up Computed Tomography Study with Comparison of Different Measurement Methods
Background The aim of this study was to evaluate long-term dilatation of Hemashield Gold and Hemashield Platinum vascular prostheses in ascending aortic position using different measurement methods to obtain precise results. Methods Between 1999 and 2007, 73 patients with Stanford type A dissection received ascending aortic replacement with Hemashield Gold and Hemashield Platinum prostheses. Measurements were performed using multiplanar reconstruction mode of electrocardiogram (ECG)-gated, multislice spiral computed tomography (MSCT) in strictly orthogonal cross-sectional planes. Different methods of measurement were compared and maximum dilatation was estimated for different time spans. Results Diameters calculated from the measured circumference showed a significant ( p =0.037) but clinically not relevant difference (0.1 mm) to the mean between the largest and the shortest cross-sectional diameter of the prosthesis. Dilatation after 24.210.2 months was 8.5 +/- 4.5%. Long-term dilatation after 91.8 +/- 34 months amounted to 11.8 +/- 4.2%. Conclusion Based on ECG-gated MSCT images, the presented methods of measurement provided reliable results. Long-term analysis shows low dilatation rates for Hemashield prostheses, which therefore can be considered as safe from this point of view. Nevertheless, a maximal dilatation of 20% could be relevant in valve sparing root replacement. It remains unclear if a dilatation like this contributes to the formation of suture aneurysms.
- 1 April 2018
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 66 (3) , 206-214
Dilatation of Vascular Prostheses in Ascending Aortic Position: A Long-Term Follow-Up Computed Tomography Study with Comparison of Different Measurement Methods
Background The aim of this study was to evaluate long-term dilatation of Hemashield Gold and Hemashield Platinum vascular prostheses in ascending aortic position using different measurement methods to obtain precise results. Methods Between 1999 and 2007, 73 patients with Stanford type A dissection received ascending aortic replacement with Hemashield Gold and Hemashield Platinum prostheses. Measurements were performed using multiplanar reconstruction mode of electrocardiogram (ECG)-gated, multislice spiral computed tomography (MSCT) in strictly orthogonal cross-sectional planes. Different methods of measurement were compared and maximum dilatation was estimated for different time spans. Results Diameters calculated from the measured circumference showed a significant ( p =0.037) but clinically not relevant difference (0.1 mm) to the mean between the largest and the shortest cross-sectional diameter of the prosthesis. Dilatation after 24.210.2 months was 8.5 +/- 4.5%. Long-term dilatation after 91.8 +/- 34 months amounted to 11.8 +/- 4.2%. Conclusion Based on ECG-gated MSCT images, the presented methods of measurement provided reliable results. Long-term analysis shows low dilatation rates for Hemashield prostheses, which therefore can be considered as safe from this point of view. Nevertheless, a maximal dilatation of 20% could be relevant in valve sparing root replacement. It remains unclear if a dilatation like this contributes to the formation of suture aneurysms.
- 13 September 2017
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 65 (07) , 505-518
German Heart Surgery Report 2016: The Annual Updated Registry of the German Society for Thoracic and Cardiovascular Surgery
Based on a long-standing voluntary registry founded by the German Society for Thoracic and Cardiovascular Surgery (GSTCVS), well-defined data of all cardiac, thoracic, and vascular surgery procedures performed in 78 German heart surgery departments during the year 2016 are analyzed. In 2016, a total of 103,128 heart surgery procedures (implantable defibrillator, pacemaker, and extracardiac procedures excluded) were submitted to the registry. Approximately 15.7% of the patients were at least 80 years of age, resulting in an increase of 0.9% compared with the data of 2015. For 37,614 isolated coronary artery bypass grafting procedures (relationship on-/off-pump 4.4:1), an unadjusted in-hospital mortality of 2.9% was observed. Concerning the 33,451 isolated heart valve procedures (including 11,701 catheter-based procedures), the unadjusted in-hospital mortality was 4.3%. This annual updated registry of the GSTCVS represents voluntary public reporting by accumulating actual information for nearly all heart surgical procedures in Germany, describes advancements in heart medicine, and is a basis for internal and external quality assurances for all participants. In addition, the registry demonstrates that the provision of cardiac surgery in Germany is appropriate and patients are treated nationwide at all times.
- 13 September 2017
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 65 (07) , 505-518
German Heart Surgery Report 2016: The Annual Updated Registry of the German Society for Thoracic and Cardiovascular Surgery
Based on a long-standing voluntary registry founded by the German Society for Thoracic and Cardiovascular Surgery (GSTCVS), well-defined data of all cardiac, thoracic, and vascular surgery procedures performed in 78 German heart surgery departments during the year 2016 are analyzed. In 2016, a total of 103,128 heart surgery procedures (implantable defibrillator, pacemaker, and extracardiac procedures excluded) were submitted to the registry. Approximately 15.7% of the patients were at least 80 years of age, resulting in an increase of 0.9% compared with the data of 2015. For 37,614 isolated coronary artery bypass grafting procedures (relationship on-/off-pump 4.4:1), an unadjusted in-hospital mortality of 2.9% was observed. Concerning the 33,451 isolated heart valve procedures (including 11,701 catheter-based procedures), the unadjusted in-hospital mortality was 4.3%. This annual updated registry of the GSTCVS represents voluntary public reporting by accumulating actual information for nearly all heart surgical procedures in Germany, describes advancements in heart medicine, and is a basis for internal and external quality assurances for all participants. In addition, the registry demonstrates that the provision of cardiac surgery in Germany is appropriate and patients are treated nationwide at all times.
- Open Access
- 16 August 2017
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 52 (5) , 881-887
The German Aortic Valve Score II
The German Aortic Valve Score (GAVS) was developed for national quality assurance regarding the in-hospital mortality rate of patients following isolated aortic valve replacement. The goal of this work was the recalibration of the GAVS in the context of increased numbers of transcatheter aortic valve implantations. In 2011 and 2012, 36 183 cases were documented who had either surgical aortic valve replacement or transcatheter aortic valve implantation (45%). All cases were randomly assigned to the study or to the validation group. All items of the data set were checked for significance by developing a multiregression risk model using iterative backward elimination. Calibration was ascertained using the Hosmer–Lemeshow method. To define the quality of discrimination, the area under the receiver operating characteristic curve (C-statistic) was calculated. The randomized study cohort comprised 18 054 patients. After modelling with multiple regression algorithms, 18 of the initial 28 risk factors entered the risk model. When applied to the validation group, the newly developed GAVS II showed good calibration with a P-value of 0.411 in the Hosmer–Lemeshow test and good discrimination with a C-statistic of 0.741. The GAVS II is a new risk model that is applicable to cohorts having surgical aortic valve replacement or transcatheter aortic valve implantation procedures.
- 16 August 2017
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 52 (5) , 881-887
Open AccessThe German Aortic Valve Score II
The German Aortic Valve Score (GAVS) was developed for national quality assurance regarding the in-hospital mortality rate of patients following isolated aortic valve replacement. The goal of this work was the recalibration of the GAVS in the context of increased numbers of transcatheter aortic valve implantations. In 2011 and 2012, 36 183 cases were documented who had either surgical aortic valve replacement or transcatheter aortic valve implantation (45%). All cases were randomly assigned to the study or to the validation group. All items of the data set were checked for significance by developing a multiregression risk model using iterative backward elimination. Calibration was ascertained using the Hosmer–Lemeshow method. To define the quality of discrimination, the area under the receiver operating characteristic curve (C-statistic) was calculated. The randomized study cohort comprised 18 054 patients. After modelling with multiple regression algorithms, 18 of the initial 28 risk factors entered the risk model. When applied to the validation group, the newly developed GAVS II showed good calibration with a P-value of 0.411 in the Hosmer–Lemeshow test and good discrimination with a C-statistic of 0.741. The GAVS II is a new risk model that is applicable to cohorts having surgical aortic valve replacement or transcatheter aortic valve implantation procedures.
- 1 September 2016
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 64 (06) , 462-474
German Heart Surgery Report 2015: The Annual Updated Registry of the German Society for Thoracic and Cardiovascular Surgery
On the basis of a long-standing voluntary registry, which was founded by the German Society for Thoracic and Cardiovascular Surgery (GSTCVS), well-defined data of all heart, thoracic, and vascular surgery procedures performed in 78 German heart surgery departments during 2015 are analyzed. In 2015, a total of 103,967 heart surgery procedures (implantable cardioverter defibrillator, pacemaker, and extracardiac procedures without ECC excluded) were submitted to the database. Approximately 14.8% of the patients were at least 80 years old, resulting in an increase of 0.6% compared with the data of 2014. For 38,601 isolated coronary artery bypass grafting procedures (relationship on-/off-pump: 5:1), the unadjusted inhospital mortality was 2.7%. Concerning the 32,346 isolated heart valve procedures (including 10,606 catheter-based implantations) an unadjusted inhospital mortality of 4.4% was observed. This annual updated registry of the GSTCVS represents voluntary public reporting by accumulating actual information for nearly all heart surgical procedures in Germany, demonstrates advancements in heart medicine, and enables internal/external quality assurance for all participants. In addition, the registry demonstrates that the provision of heart surgery in Germany is appropriate and patients are treated nationwide in a round-the-clock service.
- 1 September 2016
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 64 (06) , 462-474
German Heart Surgery Report 2015: The Annual Updated Registry of the German Society for Thoracic and Cardiovascular Surgery
On the basis of a long-standing voluntary registry, which was founded by the German Society for Thoracic and Cardiovascular Surgery (GSTCVS), well-defined data of all heart, thoracic, and vascular surgery procedures performed in 78 German heart surgery departments during 2015 are analyzed. In 2015, a total of 103,967 heart surgery procedures (implantable cardioverter defibrillator, pacemaker, and extracardiac procedures without ECC excluded) were submitted to the database. Approximately 14.8% of the patients were at least 80 years old, resulting in an increase of 0.6% compared with the data of 2014. For 38,601 isolated coronary artery bypass grafting procedures (relationship on-/off-pump: 5:1), the unadjusted inhospital mortality was 2.7%. Concerning the 32,346 isolated heart valve procedures (including 10,606 catheter-based implantations) an unadjusted inhospital mortality of 4.4% was observed. This annual updated registry of the GSTCVS represents voluntary public reporting by accumulating actual information for nearly all heart surgical procedures in Germany, demonstrates advancements in heart medicine, and enables internal/external quality assurance for all participants. In addition, the registry demonstrates that the provision of heart surgery in Germany is appropriate and patients are treated nationwide in a round-the-clock service.
- 1 August 2016
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 9 (8)
Routine Endovascular Treatment With a Stent Graft for Access-Site and Access-Related Vascular Injury in Transfemoral Transcatheter Aortic Valve Implantation
Background—: Access-site and access-related vascular injury (ASARVI) is still a major limiting factor in transcatheter aortic valve implantation and affects the outcome of patients. Management strategies for ASARVI include manual compression, stent grafts, and vascular surgery. We hypothesized that the standard use of a self-expanding stent graft for the management of ASARVI is feasible and safe. Methods and Results—: Of 407 patients treated by transfemoral transcatheter aortic valve implantation, 110 experienced ASARVI (27.0%). Of these, 96 (87.3%) were managed by the implantation of a self-expanding nitinol stent graft. In the majority of patients, minor vascular complications triggered the implantation of a stent graft (86.5%), mainly because of bleeding (90.6%) and dissection (5.2%) of the common femoral artery with high rates of primary treatment success (97.9%). Patients receiving stent grafts were more often female (62.2 versus 45.6%, P P =0.01), and suffered more often from diabetes mellitus (34.4 versus 24.5%, P =0.04). Angiographic assessment after a median follow-up of 345 days (interquartile range, 23–745 days) revealed only one patient with moderate, asymptomatic instent-stenosis (1.0%). Compared with a propensity score–matched cohort of patients without ASARVI, stented patients had comparable long-term mortality, despite the occurrence of a vascular complication (1-year mortality: 17.7% versus 26.6%; stent versus matched cohort, respectively; P =0.1). Conclusions—: Routine use of a self-expanding nitinol stent graft in selected patients experiencing ASARVI after transcatheter aortic valve implantation is feasible, safe, and associated with favorable short- and midterm clinical outcome.
- 1 August 2016
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 9 (8)
Routine Endovascular Treatment With a Stent Graft for Access-Site and Access-Related Vascular Injury in Transfemoral Transcatheter Aortic Valve Implantation
Background—: Access-site and access-related vascular injury (ASARVI) is still a major limiting factor in transcatheter aortic valve implantation and affects the outcome of patients. Management strategies for ASARVI include manual compression, stent grafts, and vascular surgery. We hypothesized that the standard use of a self-expanding stent graft for the management of ASARVI is feasible and safe. Methods and Results—: Of 407 patients treated by transfemoral transcatheter aortic valve implantation, 110 experienced ASARVI (27.0%). Of these, 96 (87.3%) were managed by the implantation of a self-expanding nitinol stent graft. In the majority of patients, minor vascular complications triggered the implantation of a stent graft (86.5%), mainly because of bleeding (90.6%) and dissection (5.2%) of the common femoral artery with high rates of primary treatment success (97.9%). Patients receiving stent grafts were more often female (62.2 versus 45.6%, P P =0.01), and suffered more often from diabetes mellitus (34.4 versus 24.5%, P =0.04). Angiographic assessment after a median follow-up of 345 days (interquartile range, 23–745 days) revealed only one patient with moderate, asymptomatic instent-stenosis (1.0%). Compared with a propensity score–matched cohort of patients without ASARVI, stented patients had comparable long-term mortality, despite the occurrence of a vascular complication (1-year mortality: 17.7% versus 26.6%; stent versus matched cohort, respectively; P =0.1). Conclusions—: Routine use of a self-expanding nitinol stent graft in selected patients experiencing ASARVI after transcatheter aortic valve implantation is feasible, safe, and associated with favorable short- and midterm clinical outcome.
- 1 April 2016
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 11 (13) , 1522-1529
The prognostic value of acute and chronic troponin elevation after transcatheter aortic valve implantation
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- 1 April 2016
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 11 (13) , 1522-1529
The prognostic value of acute and chronic troponin elevation after transcatheter aortic valve implantation
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)