Suman Samui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Suman Samui has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Indrajit Chakrabarti
5 shared publications- Soumyajit Poddar
Department of Electronics and Communication Engineering, Indian Institute Information Technology Guwahati, Guwahati, India
5 shared publications - Anand Kumar Mukhopadhyay
Department of Electronics and Electrical Communication Engineering, Indian Institute of Technology Kharagpur, Kharagpur, India
4 shared publications - Soumen Garai
Department of Electronics and Communication Engineering, National Institute of Technology Durgapur, Durgapur, India
4 shared publications Soumya Kanti Ghosh
4 shared publications- Hafizur Rahaman
Department of Information Technology, IIEST, Shibpur, Howrah, India
3 shared publications
Latest Publications
- 20 May 2026
- Published by Elsevier in Neurocomputing
- Vol. 695
Advances in small-footprint keyword spotting for TinyML: A comprehensive review of efficient models and algorithms
- 20 May 2026
- Published by Elsevier in Neurocomputing
- Vol. 695
Advances in small-footprint keyword spotting for TinyML: A comprehensive review of efficient models and algorithms
- 21 April 2026
- Published by Springer Nature
- p. 59-68
Optimizing TinyML Models for Bird Call Recognition via Multi-objective Bayesian Search and Knowledge Distillation
- 21 April 2026
- Published by Springer Nature
- p. 59-68
Optimizing TinyML Models for Bird Call Recognition via Multi-objective Bayesian Search and Knowledge Distillation
- 15 November 2024
- Published by Springer Nature
- p. 249-260
A Fast and Efficient Speech Enhancement Framework Using Audio Spectrogram Transformer with Attention Layer-Free Encoders
- 15 November 2024
- Published by Springer Nature
- p. 249-260
A Fast and Efficient Speech Enhancement Framework Using Audio Spectrogram Transformer with Attention Layer-Free Encoders
- 9 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (5) , 6418-6429
Toward Robust and Accurate Myoelectric Controller Design Based on Multiobjective Optimization Using Evolutionary Computation
Myoelectric pattern recognition holds significant importance in designing control strategies for a range of applications, including upper-limb prostheses and bio-robotic hand movement systems. It serves as a crucial aspect in formulating effective control strategies for these applications. This study presents a novel method for creating a robust and accurate EMG-based controller. The approach involves leveraging a kernelized SVM classifier to interpret surface electromyography (sEMG) signals and accurately deduce muscle movements. The primary objective in designing the classifier is to minimize false movements specifically during the "Rest" position of the controller, thereby optimizing the overall performance of the EMG-based controller. To achieve this, the training algorithm of the supervised learning system is formulated as a problem of constrained multi-objective optimization. For tuning the hyperparameters of SVM, we employ the non-dominated sorting genetic algorithm II (NSGA-II), which is an elitist multi-objective evolutionary algorithm. Experimental results are presented using a dataset comprising sEMG signals obtained from eleven subjects at five different positions of the upper limb. Furthermore, the performance of the trained models based on the two-objective metrics, namely classification accuracy, and false-negative have been evaluated on two different test sets to examine the generalization capability of the proposed training approach while implementing limb-position invariant EMG classification. The results presented clearly demonstrate that the proposed approach offers increased flexibility to the designer in selecting classifier parameters, enabling them to optimize the robustness and accuracy of the EMG-based controller more effectively.
- 9 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (5) , 6418-6429
Toward Robust and Accurate Myoelectric Controller Design Based on Multiobjective Optimization Using Evolutionary Computation
Myoelectric pattern recognition holds significant importance in designing control strategies for a range of applications, including upper-limb prostheses and bio-robotic hand movement systems. It serves as a crucial aspect in formulating effective control strategies for these applications. This study presents a novel method for creating a robust and accurate EMG-based controller. The approach involves leveraging a kernelized SVM classifier to interpret surface electromyography (sEMG) signals and accurately deduce muscle movements. The primary objective in designing the classifier is to minimize false movements specifically during the "Rest" position of the controller, thereby optimizing the overall performance of the EMG-based controller. To achieve this, the training algorithm of the supervised learning system is formulated as a problem of constrained multi-objective optimization. For tuning the hyperparameters of SVM, we employ the non-dominated sorting genetic algorithm II (NSGA-II), which is an elitist multi-objective evolutionary algorithm. Experimental results are presented using a dataset comprising sEMG signals obtained from eleven subjects at five different positions of the upper limb. Furthermore, the performance of the trained models based on the two-objective metrics, namely classification accuracy, and false-negative have been evaluated on two different test sets to examine the generalization capability of the proposed training approach while implementing limb-position invariant EMG classification. The results presented clearly demonstrate that the proposed approach offers increased flexibility to the designer in selecting classifier parameters, enabling them to optimize the robustness and accuracy of the EMG-based controller more effectively.
- 4 December 2023
- Published by Springer Nature
- p. 675-682
Heterogeneous Stacked Ensemble Framework for Surface Electromyography Signal Classification
- 4 December 2023
- Published by Springer Nature
- p. 675-682
Heterogeneous Stacked Ensemble Framework for Surface Electromyography Signal Classification
- Open Access
Towards Robust and Accurate Myoelectric Controller Design based on Multi-objective Optimization using Evolutionary Computation
Myoelectric pattern recognition is one of the important aspects in the design of the control strategy for various applications including upper-limb prostheses and bio-robotic hand movement systems. The current work has proposed an approach to design an energy-efficient EMG-based controller by considering a kernelized SVM classifier for decoding the information of surface electromyography (sEMG) signals to infer the underlying muscle movements. In order to achieve the optimized performance of the EMG-based controller, our main strategy of classifier design is to reduce the false movements of the overall system (when the EMG-based controller is at the `Rest' position). To this end, we have formulated the training algorithm of the proposed supervised learning system as a general constrained multi-objective optimization problem. An elitist multi-objective evolutionary algorithm $-$ the non-dominated sorting genetic algorithm II (NSGA-II) has been used to tune the hyperparameters of SVM. We have presented the experimental results by performing the experiments on a dataset consisting of the sEMG signals collected from eleven subjects at five different upper limb positions. Furthermore, the performance of the trained models based on the two-objective metrics, namely classification accuracy, and false-negative have been evaluated on two different test sets to examine the generalization capability of the proposed training approach while implementing limb-position invariant EMG classification. It is evident from the presented result that the proposed approach provides much more flexibility to the designer in selecting the parameters of the classifier to optimize the energy efficiency of the EMG-based controller.Open AccessTowards Robust and Accurate Myoelectric Controller Design based on Multi-objective Optimization using Evolutionary Computation
Myoelectric pattern recognition is one of the important aspects in the design of the control strategy for various applications including upper-limb prostheses and bio-robotic hand movement systems. The current work has proposed an approach to design an energy-efficient EMG-based controller by considering a kernelized SVM classifier for decoding the information of surface electromyography (sEMG) signals to infer the underlying muscle movements. In order to achieve the optimized performance of the EMG-based controller, our main strategy of classifier design is to reduce the false movements of the overall system (when the EMG-based controller is at the `Rest' position). To this end, we have formulated the training algorithm of the proposed supervised learning system as a general constrained multi-objective optimization problem. An elitist multi-objective evolutionary algorithm $-$ the non-dominated sorting genetic algorithm II (NSGA-II) has been used to tune the hyperparameters of SVM. We have presented the experimental results by performing the experiments on a dataset consisting of the sEMG signals collected from eleven subjects at five different upper limb positions. Furthermore, the performance of the trained models based on the two-objective metrics, namely classification accuracy, and false-negative have been evaluated on two different test sets to examine the generalization capability of the proposed training approach while implementing limb-position invariant EMG classification. It is evident from the presented result that the proposed approach provides much more flexibility to the designer in selecting the parameters of the classifier to optimize the energy efficiency of the EMG-based controller. - 1 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 86-90
Forearm Orientation Invariant Analysis for Surface Myoelectric Pattern Recognition
In this work, we have performed a forearm orientation invariant analysis for artificial wrist movement classification on a specific subject using the surface electromyography (sEMG) signal. The muscle contraction effect has been included to incorporate the variation in force levels by the subject user. The Time-Domain Power Spectral Density (TD-PSD) predictors have been considered, which assists the real-time operation of the controller. Our main focus in this paper is to develop an optimum model, independent of the forearm orientation angle which will map the sEMG signals captured through the sensors on the forearm to the correct hand movement response. This is useful in developing intelligent artificial myoelectric controllers for both healthy patients as well as amputees requiring an intelligent artificial hand. It is found that the extreme forearm orientation angles (0° and 180°) have a significant improvement (> 15 %) in the testing accuracy compared to the other combinations for orientation invariant analysis.
- 1 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 86-90
Forearm Orientation Invariant Analysis for Surface Myoelectric Pattern Recognition
In this work, we have performed a forearm orientation invariant analysis for artificial wrist movement classification on a specific subject using the surface electromyography (sEMG) signal. The muscle contraction effect has been included to incorporate the variation in force levels by the subject user. The Time-Domain Power Spectral Density (TD-PSD) predictors have been considered, which assists the real-time operation of the controller. Our main focus in this paper is to develop an optimum model, independent of the forearm orientation angle which will map the sEMG signals captured through the sensors on the forearm to the correct hand movement response. This is useful in developing intelligent artificial myoelectric controllers for both healthy patients as well as amputees requiring an intelligent artificial hand. It is found that the extreme forearm orientation angles (0° and 180°) have a significant improvement (> 15 %) in the testing accuracy compared to the other combinations for orientation invariant analysis.
- 1 January 2019
- Published by Elsevier in Applied Soft Computing
- Vol. 74, 583-602
Time–frequency masking based supervised speech enhancement framework using fuzzy deep belief network
- 1 January 2019
- Published by Elsevier in Applied Soft Computing
- Vol. 74, 583-602
Time–frequency masking based supervised speech enhancement framework using fuzzy deep belief network