    Sustained Radiopacity of Biodegradable Iodinated Polyether Blends for Tracking Long-Term Degradation in Medical Devices

    by Netsanet Waal, Mayson Whipple, Robert C. Ferrier Jr, D. Adam Lauver, Kendell Pawelec

    Longitudinal monitoring of biomedical devices is emerging as the next phase of personalized medicine, enabling individualized treatment plans based on radiological evaluation of devices over time. However, incorporation of a contrast agent is necessary to functionalize polymeric devices for imaging, but must be balanced by changes in device properties and biocompatibility. Here we demonstrate the use of a novel polymer blend as a potential material for biomedical devices incorporating imaging functionality, consisting of 90% biodegradable poly(lactide-co-glycolide) (PLGA 50:50) matrix and 10% of an iodinated block co-polymer, poly(ethylene oxide)-co-poly(epichlorohydrin) (PEO-PECH). Addition of the iodinated PEOPECH produced porous radiopaque phantom devices with up to 3 wt% iodine. The porous phantoms remained CT-visible for the duration of a 12-week in vitro degradation study, with changes in attenuation correlating to changes in apparent density. Phantom mechanics and mass loss were affected by PECH molecular weight and iodine content in the blend but remained comparable to properties of clinical devices. During degradation, iodine was released from phantoms at a steady rate. The iodine remained molecularly bound to the polyether, which was lost more slowly than the PLGA matrix. The stable degradation and consistent attenuation make this blend promising for use in biomedical devices.

  • Open Access

    In vivo study of the effect of composition and implantation site on scaffold degradation rate

    by Kendell M. Pawelec, Jeremy M. L. Hix, Arianna Troia, Niharika Sinha, Keith W. MacRenaris, Matti Kiupel, Thomas V. O’HAlloran, Erik M. Shapiro

  • Open Access

    Material Composition and Implantation Site Affect in vivo Device Degradation Rate

    by Kendell Pawelec, Jeremy Hix, Arianna Troia, Niharika Sinha, Keith MacRenaris, Matti Kiupel, Thomas O'HAlloran, Erik Shapiro

    Tissue engineering requires biomedical devices that stabilize wounds, then degrade as tissue regenerates. However, published material degradation rates are often conflicting. Incorporating monitoring functionality into implanted devices allows real-time assessment of degradation and failure, but requires contrast agents, as most biomedical devices are composed of polymeric materials invisible to medical imaging modalities. Computed tomography (CT)-visible radiopaque composites were created from 5-20wt% tantalum oxide (TaOx) nanoparticles in polymers with distinct degradation profiles: polycaprolactone (PCL), poly(lactide-co-glycolide) (PLGA) 85:15 and PLGA 50:50, representing slow, medium and fast degrading materials respectively. Radiopaque phantoms, mimicking biomedical devices, were implanted into mice intramuscularly or intraperitoneally, and monitored via CT over 20 weeks. Changes in phantom volume, including collapse and swelling, were visualized. Phantom degradation profile was dictated by polymer matrix, regardless of nanoparticle addition. Foreign body response was dependent on implant site and degradation kinetics were significantly affected in mid-degrading materials, transitioning from linear degradation intramuscularly to exponential degradation intraperitoneally, due to differences in inflammatory responses and fluid flow. Nanoparticle excretion via liver and spleen lagged polymer degradation, requiring modulation of nanoparticle clearance. Tracking real time device behavior advances the new era of personalized medicine, allowing individualized treatment plans to biomedical devices.

  • Open Access

    Non-cytotoxic, iodinated poly(ethylene oxide) (PEO) block- co -polymer contrast agents for computed tomography (CT) imaging

    by Mayson Whipple, Barbara Christian, Kendell M. Pawelec, Netsanet Waal, D. Adam Lauver, Robert C. Ferrier

    We present a novel polymeric contrast agent based on PEG-derivatives that is non-cytotoxic and provides excellent contrast for CT imaging. The block size and iodine incorporation is highly tunable and enables modulation of properties.


  • Open Access

    Distinct Roles of Surface Nanostructure and Polymer Degradation in Fibroblast Response to Device Design

    by Kendell M Pawelec, Erik M. Shapiro

    Fibrotic encapsulation of implanted biomedical devices represents the highest cause of device failure across numerous fields, including orthopedics, breast implants and neural electrodes. While most research has focused on the immune system for driving the foreign body response to devices, fibroblasts are emerging as another key regulator of tissue response. In the present study, we evaluated the effects of porous device design on the activation of primary human dermal fibroblasts into myofibroblasts, a contractile cell that is a hallmark of fibrosis, over four weeks in culture. In particular two factors were studied 1) the introduction of nanoparticles, as they are increasingly being used for device functionalization, and 2) the polymer matrix, which dictates chemistry, mechanics and degradation. The addition of tantalum oxide (TaOx) nanoparticles (0-20wt%) had a minimal effect on fibroblasts, significantly down-regulating expression of alpha smooth muscle actin (αSMA) (0.31 ± 0.1), likely driven by the increase in nanoscale surface roughness. The polymer matrix of the device caused significant changes to myofibroblast activation, with the fast degrading polymer, poly(lactide co-glycolide) (PLGA) 50:50, significantly up-regulating multiple myofibroblast markers, including αSMA (5.16 ± 2.5), vinculin, integrin β 1 , and integrin β 5 , compared to non-degrading polycaprolactone (PCL). The effect was due to the release of degradation products, namely lactic acid, which affects cellular metabolism. Together this highlights that device design affects biological response immediately post-implantation in ways that impact the ultimate success or failure of biomedical devices.

  • Open Access

    Non-cytotoxic, iodinated poly(ethylene oxide) (PEO) block-co-polymer contrast agents for computed tomography (CT) imaging.

    by Mayson Whipple, Barbara Christian, Kendell M. Pawelec, D. Adam Lauver, Robert C. Ferrier

    Medical imaging techniques like X-ray, Magnetic Resonance Imaging (MRI), and Computed Tomography (CT) rely on contrast agents to enhance the visibility of blood vessels, tissues, and organs making them crucial for medical diagnoses. Contrast agents used clinically are typically small molecules containing iodine, which are associated with nephrotoxicity, large dose requirements with potentially thyroid-disrupting levels of iodine, short half-lives, and are sometimes immunogenic. Loading/functionalization of larger molecules with iodine may attenuate X-rays similarly to small molecules, but at much lower concentrations, potentially mitigating the adverse effects of current contrast agents. To test this, iodinated poly(ethyene oxide) (PEO) was synthesized with varying amounts of iodine and structural features and examined for use as a contrast agent. First, 5 kDa PEG containing one terminal hydroxyl was reacted with trimethylaluminum to form a macroinitiator from which block-co-polymers consisting of PEO-co-poly(epichlorohydrin) (PECH) were synthesized with PECH blocks of 5, 15, and 30 kDa. The polymers were subsequently iodinated and characterized with 1H NMR and 13C NMR spectroscopy, size exclusion chromatography (SEC), and differential scanning calorimetry (DSC). X-ray attenuation was found to rival that of iohexol, a conventional contrast agent, at 1/20th the concentration. Further, we found that high molecular weight polymers were completely non-cytoxic, unlike iohexol. These new materials hold promise as medical contrast agents.

  • Open Access

    Hydrophilic Particles Exit While Hydrophobic Particles Persist Following In Vivo Biodegradation of Nanoparticle‐Laden Polymeric Devices

    by Kendell M. Pawelec, Jeremy M. L. Hix, Matti Kiupel, Peter J. Bonitatibus, Erik M. Shapiro

    Longitudinally monitoring biomedical devices postimplantation can improve patient outcomes by allowing targeted intervention during healing. Most polymeric devices are not visible via biomedical imaging technologies. Incorporation of nanoparticle contrast agents into polymer matrices creates imageable devices, but understanding and controlling nanoparticle clearance from the implant site after polymer degradation is needed for clinical translation. To achieve homogeneous distribution throughout biomedical devices, nanoparticle surface chemistry, particularly hydrophobicity, is often manipulated to generate stable suspensions during manufacture. As nanoparticle surface chemistry is a key parameter determining blood circulation, the effects of nanoparticle hydrophilicity on tissue clearance of nanoparticles from implant sites following polymeric device degradation are investigated. Hydrophilic and hydrophobic radiopaque tantalum oxide (TaOx) nanoparticles are incorporated at 10 wt% tantalum into gelatin phantoms. In vitro, the diffusion coefficient of released hydrophilic nanoparticles after phantom degradation is significantly greater than hydrophobic nanoparticles, 1.29 ± 0.26 × 10−5 and 0.40 ± 0.16 × 10−5 cm2 s−1, respectively. After subcutaneous implantation in mouse and subsequent phantom degradation, hydrophilic nanoparticles clear skin and muscle tissue within 24 h, whereas hydrophobic nanoparticles remained at the implant site >14 days without change in radiopacity. This clearly demonstrates that nanoparticle surface chemistry must be balanced for initial device manufacturing and final excretion.


  • Open Access

    Material Composition and Implantation Site Affect in vivo Device Degradation Rate

    by K. M. Pawelec, J. M.L. Hix, A. Troia, M. Kiupel, E. M. Shapiro

    Successful tissue engineering requires biomedical devices that initially stabilize wounds, then degrade as tissue is regenerated. However, the material degradation rates reported in literature are often conflicting. Incorporation of in situ monitoring functionality into implanted devices would allow real time assessment of degradation and potential failure. This necessitates introduction of contrast agent as most biomedical devices are composed of polymeric materials with no inherent contrast in medical imaging modalities. In the present study, computed tomography (CT)-visible radiopaque composites were created by adding 5-20wt% tantalum oxide (TaO x ) nanoparticles into polymers with distinct degradation profiles: polycaprolactone (PCL), poly(lactide-co-glycolide) (PLGA) 85:15 and PLGA 50:50, representing slow, medium and fast degrading materials respectively. Radiopaque phantoms, mimicking porous tissue engineering devices, were implanted into mice intramuscularly or intraperitoneally, and monitored via CT over 20 weeks. Changes in phantom volume, including collapse and swelling, were visualized over time. Phantom degradation profile was determined by polymer matrix, regardless of nanoparticle addition and foreign body response was dictated by the implant site. In addition, degradation kinetics were significantly affected in mid-degrading materials, transitioning from linear degradation intramuscularly to exponential degradation intraperitoneally, due to differences in inflammatory responses and fluid flow. Nanoparticle excretion from degraded phantoms lagged behind polymer, and future studies will modulate nanoparticle clearance. Utilizing in situ monitoring, this study seeks to unify literature and facilitate better tissue engineering devices, by highlighting the relative effect of composition and implant site on important materials properties.


  • Open Access

    Device Design and Advanced Computed Tomography of 3D Printed Radiopaque Composite Scaffolds and Meniscus

    by Mitchell Delemeester, Kendell M. Pawelec, Jeremy M.L. Hix, James R. Siegenthaler, Micah Lissy, Philippe C. Douek, Angèle Houmeau, Salim A. Si‐Mohamed, Erik M. Shapiro

    3D‐printed biomaterial implants are revolutionizing personalized medicine for tissue repair, especially in orthopedics. In this study, a radiopaque bismuth oxide (Bi2O3) doped polycaprolactone (PCL) composite is developed and implemented to enable the use of diagnostic X‐ray technologies, especially spectral photon counting X‐ray computed tomography (SPCCT), for comprehensive tissue engineering scaffold (TES) monitoring. PCL filament with homogeneous Bi2O3 nanoparticle (NP) dispersion (0.8 to 11.7 wt%) is first fabricated. TES are then 3D printed with the composite filament, optimizing printing parameters for small features and severely overhung geometries. These composite TES are characterized via micro‐computed tomography (µCT), tensile testing, and a cytocompatibility study, with 2 wt% Bi2O3 NPs providing improved tensile properties, equivalent cytocompatibility to neat PCL, and excellent radiographic distinguishability. Radiographic performance is validated in situ by imaging 4 and 7 wt% Bi2O3 doped PCL TES in a mouse model with µCT, showing excellent agreement with in vitro measurements. Subsequently, CT image‐derived swine menisci are 3D printed with composite filament and re‐implanted in corresponding swine legs ex vivo. Re‐imaging the swine legs via clinical CT allows facile identification of device location and alignment. Finally, the emergent technology of SPCCT unambiguously distinguishes the implanted meniscus in situ via color K‐edge imaging.