SGShima Ghasemi

Shima Ghasemi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shima Ghasemi has a total of 54 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Effect of Single-stage Oral Disinfection and Quadrant Scaling and Root Planing on Serum IL-23 Level and Periodontal Clinical Indices in Periodontitis

    by Adileh Shirmohammadi, Amirreza Babaloo, Shima Ghasemi, Mahdi Rahbar, Safa Valizadeh Haghi, Rima Shirzadeh

    Introduction: Periodontitis is a chronic inflammatory condition marked by the gradual destruction of tooth-supporting structures. Interleukin-23 (IL-23) plays a central role in the progression of periodontal disease. Thus, this study aimed to assess serum IL-23 levels and periodontal indices following single-stage full-mouth disinfection (FMD) and quadrant scaling and root planing (Q-SRP) in patients with chronic, moderate-to-advanced periodontitis. Methods: Twenty patients were included in this double-blind trial study and divided into two groups. One group received single-stage FMD, while the other underwent Q-SRP. Periodontal status was assessed by measuring the clinical attachment level (CAL), bleeding on probing (BOP), plaque index (PI), probing depth (PD), and the modified gingival index (MGI). Evaluations were performed at baseline and at two- and four-month follow-ups. Moreover, serum IL-23 levels were estimated at the time points using an enzyme-linked immunosorbent assay. Data were analyzed with SPSS 16. Results: Mean serum IL-23 levels decreased after both FMD and Q-SRP treatments, with no statistically significant difference between the groups (P>0.05). Periodontal indices, including BOP, CAL, PI, and PD, improved in both groups, again without significant intergroup differences (P>0.05). However, the MGI was significantly lower in the FMD group at 2-month and 4-month follow-ups (P<0.05). Conclusion: Both FMD and Q-SRP effectively enhanced periodontal parameters while reducing serum IL-23 levels, with no significant differences between the two methods for most indices. Overall, although the lower MGI observed in the FMD group suggests a potential advantage in reducing gingival inflammation, the findings indicate that both treatments are similarly effective.

  • Open Access

    Serum levels of vitamin E, vitamin D, and omega-3 fatty acids in patients with generalized chronic periodontitis: A cross-sectional study

    by Shima Ghasemi, Amirreza Babaloo, Mohammadtaghi Chitsazi, Atiyeh Ghassemi, Saeid Forghani

    Background. The present study aimed to investigate the serum levels of vitamin D, vitamin E, and omega-3 in patients with chronic periodontitis. Methods. Thirty-six patients with periodontitis participated in this cross-sectional descriptive study. Clinical parameters such as the gingival index, pocket depth (PD) (mm), and clinical attachment loss (CAL) (mm) were measured. Serum samples were obtained and analyzed for levels of vitamin D, vitamin E, and omega-3 fatty acids. The data were analyzed using SPSS 24, and a probability value of<0.05 was considered statistically significant. Results. All the clinical parameters used to measure periodontal status differed significantly according to the severity of periodontitis (P<0.05). The mean serum levels of all vitamins and omega-3 fatty acids were lower in the severe periodontitis group than in the moderate periodontitis group. The mean levels were high in the mild periodontitis group. However, the differences were significant only for vitamin E and vitamin D (P<0.05). No statistically significant effect was observed for omega-3 fatty acids, but higher amounts of omega-3 fatty acids were detected in mild periodontitis patients than in moderate and severe periodontitis patients. Conclusion. It can be concluded that the optimal consumption of vitamin E and vitamin D, either as supplements or as part of an individual’s daily diet, may contribute to maintaining periodontal health.

  • Open Access

    Effects of differentangles of abutment screwchannel on removal torquevalue of ball torx screws

    by Fatemeh Bakhtiari, Ramin Negahdari, Amirreza Babaloo, Kasra Rahimipour, Shima Ghasemi

    Aim: This study investigates the impact of various tightening protocols on torque requirements in screw-retained crowns, focusing on the Angulated Screw Channel (ASC) system. The ASC alters the screw channel angle in the crown while aligning the abutment with the implant, potentially enhancing function and aesthetics in cases of improper implant positioning. Methods: The investigation involved three sample groups: DIO abutment with 0-degree screw access and regular screw (D0), Ti-base angled screw channel abutment with 0-degree access and ball torx screw (A0), and Ti-base with 20-degree access and ball torx screw (A20). Each group was subdivided into four protocol categories, using nine screws each. Screws were initially hand-tightened, then subjected to the respective tightening protocols, with torque measurements taken using a calibrated Digital Torque Meter. Results: Significant statistical differences in torque requirements were observed between the D0 group and both the A0 and A20 groups. However, the torque reduction percentage did not vary significantly among the different tightening protocols or between the 0- and 20-degree angles in the ASC system. The results indicate notable distinctions in torque needs between standard and angled screw channel systems. The lack of significant variance in tightening protocols and angles within the ASC system suggests consistency in torque requirements, regardless of these factors. Conclusions: While the ASC system demonstrates a significant difference in torque requirements compared to the traditional system, the angle of the screw channel and the tightening protocol do not substantially affect torque reduction in the ASC system.

  • Open Access

    A comparative study of deformation in hexagonal and star-shaped implant screwdriver heads

    by Amin Nourizadeh, Shima Ghasemi, Elnaz Shafiee, Sevda JafarZadeh, Fatemeh Bakhtiari

    Dental implants are a popular and effective solution for replacing missing teeth. However, there are challenges such as screw loosening and component failure. This deformation can impact torque application and screw retention. While research has focused on implant system longevity, there is limited investigation into how different screwdriver head designs, particularly hexagonal and star-shaped, perform under repeated opening and closing cycles, which are crucial for long-term implant stability. The study compared the deformation characteristics of hexagonal and star-shaped implant screwdriver heads after multiple opening and closing cycles. In this in vitro experimental study, abutments were placed on two implant systems mounted in die stone and torqued to 25 N/cm according to the manufacturer’s recommendations, using 12 screwdrivers (n = six for each implant). The screwdriver heads underwent examination under a stereomicroscope at 50x magnification. Subsequently, the outline and deformation of the screwdriver head after 0, 50, 100, 200, and 300 opening and closing cycles were analyzed using AutoCAD software. The changes in the surface area of hexagonal and star-shaped driver heads after different cycles were statistically evaluated using SPSS 24 (α = 0.05). The investigation revealed a reduction in the surface area of both hexagonal and star-shaped driver heads with an increase in the frequency of cycles. Notably, following all cycles, except 0–50 and 50–100, the alterations in the surface area of the star-shaped driver head were significantly greater than those observed in the hexagonal driver head (P < 0.001). The study shows that the star-shaped driver head deformed more than the hexagonal one, especially in cycles exceeding 100.


  • Open Access

    Evaluation of Microgap Size and Microbial Microleakage at the Implant Fixture–Abutment Interface in Original and Compatible Abutments

    by Reza Sharifi, Tahereh Ghaffari, Shima Ghasemi, Hossein Samadi Kafil

    Introduction: The microgap between implant and abutment can lead to mechanical and biological problems such as abutment screw breakage or peri‐implantitis. The utilization of compatible abutments in place of the original components results in a decrease in costs and provides dentists with a broader selection of abutment options. The purpose of this study was to compare bacterial microleakage and microgap in the Korean Osstem, Dio, and Cis systems, whose regular abutments are compatible with each other. Method: Twelve implant abutments were used in this study, each four from Osstem (Seoul, South Korea), Dio (Seoul, South Korea), and Cis (Medimecca, Seoul, South Korea), all measuring 7 mm in length, 4.5 mm in diameter, and 3 mm in height. These were attached to Osstem fixtures of regular size (4.5 mm diameter and 11.5 mm length), which were contaminated with a bacterial suspension. Bacterial contamination was assessed at 5, 24, and 48 h, while microgap size was measured at four points using an electron microscope. Statistical analyses, including one‐way ANOVA and the Kruskal–Wallis tests, were performed by SPSS 17 to evaluate differences in microgap and microleakage among the groups. Results: There is a statistically significant difference between the mean microgap in the Dio group and the other two groups. The mean microgap in the Dio group was higher than both of the other groups ( p value < 0.001). There is no statistically significant difference between the mean microgap in the Osstem group and its mean in the Cis group ( p value > 0.05). There was no statistically significant difference between the mean number of colonies (CFU) in the study groups at any of the four evaluation times ( p value > 0.05). Conclusion: Considering the limitations of this study, it can be inferred that the Cis‐compatible abutment is also applicable for use with the Osstem fixtures.


  • Open Access

    Evaluation of the effect of Echium amoenum on pain control after clinical crown lengthening surgery

    by Shima Ghasemi, Fatemeh Bakhtiari, Pariya Rahimi Asl, Amirreza Babaloo, Atieh Ghasemi

    Background. Pain after periodontal surgeries is one of the most common complications. Echium amoenum is among the important therapeutic herbs in Iranian traditional medicine. Various studies have shown its pain control properties. This study aimed to evaluate this herb’s efficacy in controlling pain after periodontal surgeries. Methods. In this randomized clinical trial, 50 patients referred to Tabriz Dental School for clinical crown lengthening surgery were divided into two equal groups: control and test. In the test group (using E. amoenum), 24 hours before surgery, E. amoenum was administered to the patient at home every 12 hours, and a dose of E. amoenum was administered one hour before the procedure. The postoperative pain was assessed using VAS 30 minutes, 1 hour, and 3 hours after the surgery and verbal rating scale (VRS) 24, 48, and 72 hours postoperatively. A chi-square test was used to compare the pain severity between the two groups. Results. The VAS index was significantly lower in the E. amoenum group compared to the control group (30 minutes, 1 hour, and 3 hours after the procedure) (P<0.05). In both groups, pain severity increased significantly up to 3 hours postoperatively (P<0.05). In the first 24 hours, the VRS index of the E. amoenum group was significantly lower than that of the control group (P0.05). Conclusion. The E. amoenum herb reduced the pain severity after clinical crown lengthening surgeries.


  • Open Access

    Prevalence of proximal contact loss between implant-supported fixed prosthesis and adjacent teeth and associated factors: A systematic review and meta-analysis

    by Shima Ghasemi, Laleh Oveisi-Oskouei, Ali Torab, Hanieh Salehi-Pourmehr, Amirreza Babaloo, Nafiseh Vahed, Nasrin Abolhasanpour, Sina Taghilou, Atieh Ghasemi

    Background. This systematic review and meta-analysis investigated the prevalence of proximal contact loss and its associated factors. Methods. A bibliographic search was conducted in June 2021 with no limitation in the article date or language and updated in January 2022 by hand searching. There was no time limit on the search to retrieve all studies. The search included randomized controlled trials or quasi-experiments, and cross-sectional or cohort studies were included in the absence of these studies. Two authors screened the title and After evaluating the full texts of selected articles, irrelevant studies and or non-English papers that were impossible to translate were excluded. Disagreements between the re­viewers’ selection process were resolved by debate on the eligibility of studies. Standardized critical appraisal instruments from the Joanna Briggs Institute for different types of studies were used to assess the studies’ quality. Comprehensive Meta-Analysis (CMA) software (Version 2.2; Biostat, Englewood, NJ) was used for data analysis. Results. The proximal contact loss (PCL) frequency was %29. According to the results, the frequencies of PCL for the distal and mesial aspects were %7 and %21, respectively. The meta-analysis results showed that the contact loss events on the mesial aspect were statistically higher than on the distal aspect (P%50, the proximal contact loss was higher (OR: %95[ 2.43 CI: 4.03‒1.47], P=0.0006). The PCL in the anterior area was lower than in the posterior area (P=0.004). Although the frequency of contact loss in females was higher than in males, this rate was not statistically significant. Conclusion. The PCL on the mesial aspect and the posterior area was high. In individuals with bone loss >%50, the proximal contact loss was higher than in others.


  • Open Access

    Effect of vitamin B complex administration on pain and sensory problems related to inferior alveolar nerve damage following mandibular implant placement surgery

    by Shima Ghasemi, Amirreza Babaloo, Mehrnoosh Sadighi, Zeinab Torab, Hamidreza Mohammadi, Elshan Khodadust

    Background. Inferior alveolar nerve damage can lead to mild to severe paresthesia and even facial pain. One of the treatments considered today for the reconstruction and treatment of damaged peripheral nerves is the use of vitamin supplements. This study aimed to evaluate the effect of vitamin B complex supplementation on pain and sensory problems following mandibular implant placement surgery. Methods. In this single-blind clinical trial, 46 patients applying for implant placement, who were eligible for the study, were evaluated. All the patients were examined for sensory facial injury and inferior alveolar nerve injury within 24 hours after implant placement. The nerve damage was recorded by AI (asymmetry index) in the initial examination. Patients who reported clinical and radiographic signs of nerve damage due to implant or drill impingement of the nerve canal were excluded from the study and promptly treated with anti-inflammatory protocols. Then the patients were randomly divided into control (n=23) and intervention (n=23) groups. Patients in the control group received routine treatment after implantation, and patients in the intervention group received vitamin B complex pills in addition to routine treatment. A placebo was used to eliminate the inductive effect of the drug in the control group. Follow-up of patients was performed at intervals of 14 days and 1, 2, and 3 months after treatment. Data analysis was performed using SPSS 24 and Kruskal-Wallis, Wilcoxon, and chi-squared tests. Results. In both groups, a decreasing trend in pain intensity was observed for up to three months. There were no significant differences between the mean pain intensity in the intervention and control groups at all the follow-up intervals. In both groups, a decrease in the rate of paresthesia was observed during the 3-month follow-up. The mean of paresthesia in the two groups was not significantly different at any follow-up interval. Conclusion. Vitamin B complex might not affect pain intensity and paresthesia after implant surgery.


  • Open Access

    Evaluation of the effect of coenzyme Q10 supplementation along with scaling and root planing (SRP) on periodontal and gingival indices in controlled diabetic patients

    by Shima Ghasemi, Zeinab Torab, Adileh Shirmohammadi, Amirreza Babaloo, Reza Johari, Farrokh Farhadi, Majid Mobasseri, Hamidreza Mohammadi

    Background. This clinical trial evaluated the effect of coenzyme Q10 supplementation along with scaling and root planing (SRP) on periodontal and gingival indices in controlled diabetic patients. Methods. Forty-two diabetic patients (controlled type), referred to the Department of Periodontics with chronic periodontitis and eligible for the study, were included in the study. Patients suffering from chronic periodontitis with a probing pocket depth of ≥5 mm in different quadrants of the oral cavity with radiographic evidence of bone loss were included in the present randomized, double-masked, placebo-controlled clinical trial. The subjects were instructed to take one capsule of coenzyme Q10 or a placebo every day for 30 days following SRP. Clinical parameters, i.e., plaque index (PI), gingival index (GI), bleeding on probing (BOP), clinical attachment level (CAL), and probing pocket depth (PPD), were recorded at baseline and four weeks after treatment by two masked and calibrated examiners. The study results were reported as (mean ± standard deviations) and frequencies (percentages). Results. One month after the intervention, PPD, CAL, BOP, and PI indices in the intervention group were significantly lower than those in the control group. One month after the intervention, the GI was similar in both groups. A significant decrease was observed in the GI in both groups after the intervention. Conclusion. The results of the present study showed that Q10 orally with scaling and root planing in patients with controlled diabetes with chronic periodontitis might accelerate the treatment process and significantly reduce the pocket depth.


  • Open Access

    An In Vitro Analysis of the Antifungal Effect of Nystatin and Fluconazole Incorporated into Tissue Conditioner with and Without Using Varnish Containing Self-cured Resin and 1,1,1-Trichloroethane

    by Shima Ghasemi, Safa Raeesi, Katayoun Sadr, Azra Kiafar, Amir Reza Babaloo

    Background: Incorporating antifungal drugs into liners has been proposed to treat denture stomatitis. Varnish application on tissue conditioners can decrease the porosities and irregularities, biofilm, and pathogens adhesion. In this study, we evaluated the effect of varnish application on releasing the antifungal drugs incorporated into tissue conditioners. Methods: Pure form of nystatin and fluconazole were mixed into tissue conditioner powder separately at 5% wt/wt concentration and prepared according to manufacturer’s instruction. Then, disk-shaped specimens (5 mm in diameter and 1 mm in thickness) were prepared at 30 nystatin and 30 fluconazole specimens. Varnish (containing 50 mL of 1,1,1-trichloroethane and 3 ml of self-cured resin) was applied on the surface of 15 disks of each drug and the other specimens were used as the control group (without varnish). Next, the disks were put in agar plates cultured with standard Candida albicans and incubated for 7 days. Mean inhibition diameter for each disk was measured with digital caliper at 24 hours, 3 days, and 7 days. Each step was performed in triplicate. Data was analyzed with one-way ANOVA and Friedman, Wilcoxon, and Mann-Whitney U tests. Results: The mean inhibition diameter (MID) at days 1, 3, and 7 in fluconazole without varnish group was 12.63, 3.90, and 3.67, respectively; in fluconazole with varnish was 3.00, 2.50, and 2.50, respectively; in nystatin without varnish was 5.78, 3.90, and 3.87, respectively; in nystatin with varnish group was 2.50, 0.00, and 0.00, respectively. fluconazole without varnish group exhibited significantly higher MID and nystatin with varnish group had lower MID. Conclusions: In this experimental study, fluconazole was more effective than nystatin. In groups without varnish, antifungal effect continued up to day 7. Using varnish in tissue conditioner can decrease antifungal effect.