Natakorn Thasnas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Natakorn Thasnas has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Apirat Siritaratiwat
Department of IoT and Information Engineering, School of Engineering, King Mongkut’s Institute of Technology Ladkrabang, Bangkok 10520, Thailand
2 shared publications - Kriengkrai Nabudda
Department of Industrial Engineering, School of Engineering, King Mongkut’s Institute of Technology Ladkrabang, Bangkok 10520, Thailand
2 shared publications Apirat Siritaratiwat
Khon Kaen University
1 shared publication- Narong Kamolrat
Faculty of Natural Resources and Agro-Industry, Kasetsart University, Chalermphrakiat Sakon Nakhon Province Campus, Sakon Nakhon 47000, Thailand
1 shared publication - Natthanan Wanna
Department of Electrical and Computer Engineering, Faculty of Science and Engineering, Kasetsart University, Chalermphrakiat Sakon Nakhon Province Campus, Sakon Nakhon, Thailand
1 shared publication Neville Robert Watson
Department of Electrical and Computer Engineering University of Canterbury Christchurch New Zealand
1 shared publication
Latest Publications
- Open Access
- 24 June 2026
- Published by Elsevier in Ain Shams Engineering Journal
- Vol. 17 (8)
Integrated CFD–drying model for design optimisation of multi-layer rack drying systems for mackerel processing
- 24 June 2026
- Published by Elsevier in Ain Shams Engineering Journal
- Vol. 17 (8)
Open AccessIntegrated CFD–drying model for design optimisation of multi-layer rack drying systems for mackerel processing
- Open Access
- 5 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 69612-69632
Multi-Regime GRU-Scheduled PID Control for Greenhouse VPD Regulation With Real-Time PLC Deployment
Vapor pressure deficit is a physiologically meaningful climate variable governing plant transpiration and water transport in greenhouse cultivation. However, accurate regulation in evaporative-cooled greenhouses is challenging due to nonlinear temperature–humidity coupling, time-varying dynamics, and rapidly changing solar disturbances. Conventional fixed-gain proportional–integral–derivative controllers, tuned for a single operating condition, often exhibit performance degradation under regime transitions. This study proposes a multi-regime admissible-region-constrained gain-scheduled control framework in which a gated recurrent unit network serves as a supervisory scheduler to generate smooth, near-optimal controller gains for real-time vapor pressure deficit regulation. Control-oriented first-order-plus-dead-time models are identified under representative operating regimes, and an interval-bounded plant ensemble is constructed to capture dynamic variability. Regime-wise optimal gains are obtained offline using hybrid evolutionary optimization and used as supervisory training labels. To support safe deployment, all scheduled gains are constrained within a pre-validated admissible stability region, such that each deployed gain configuration remains inside an offline-validated frozen-time stabilizing set. The controller is implemented on an industrial programmable logic controller and experimentally validated in a full-scale evaporative greenhouse under real environmental disturbances. Comparative multi-day experiments demonstrate improved tracking accuracy, reduced overshoot, smoother actuator behavior, and enhanced disturbance attenuation relative to fixed-gain strategies, while maintaining deterministic real-time execution. The results establish an industrially deployable learning-based gain-scheduling framework for practical greenhouse climate control.
- 5 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 69612-69632
Open AccessMulti-Regime GRU-Scheduled PID Control for Greenhouse VPD Regulation With Real-Time PLC Deployment
Vapor pressure deficit is a physiologically meaningful climate variable governing plant transpiration and water transport in greenhouse cultivation. However, accurate regulation in evaporative-cooled greenhouses is challenging due to nonlinear temperature–humidity coupling, time-varying dynamics, and rapidly changing solar disturbances. Conventional fixed-gain proportional–integral–derivative controllers, tuned for a single operating condition, often exhibit performance degradation under regime transitions. This study proposes a multi-regime admissible-region-constrained gain-scheduled control framework in which a gated recurrent unit network serves as a supervisory scheduler to generate smooth, near-optimal controller gains for real-time vapor pressure deficit regulation. Control-oriented first-order-plus-dead-time models are identified under representative operating regimes, and an interval-bounded plant ensemble is constructed to capture dynamic variability. Regime-wise optimal gains are obtained offline using hybrid evolutionary optimization and used as supervisory training labels. To support safe deployment, all scheduled gains are constrained within a pre-validated admissible stability region, such that each deployed gain configuration remains inside an offline-validated frozen-time stabilizing set. The controller is implemented on an industrial programmable logic controller and experimentally validated in a full-scale evaporative greenhouse under real environmental disturbances. Comparative multi-day experiments demonstrate improved tracking accuracy, reduced overshoot, smoother actuator behavior, and enhanced disturbance attenuation relative to fixed-gain strategies, while maintaining deterministic real-time execution. The results establish an industrially deployable learning-based gain-scheduling framework for practical greenhouse climate control.
- 3 February 2026
- Published by Chiang Mai University in Natural and Life Sciences Communications
- Vol. 25 (3)
Bio-inspired LED Lighting and Nutrient Supplementation for Sustainable Wolffia globosa Cultivation
This study demonstrates an effective cultivation protocol for Wolffia globosa through a bio-inspired approach. Light parameters from the plant's natural, shaded habitats (PPFD ~44 µmol m⁻² s⁻¹) were first characterized to calibrate a laboratory LED system. The experiment revealed that a one-time nutrient supplementation at initiation was the critical factor for sustained growth. While all treatments were exposed to the same light regimen, the unenriched groups (C, T1, T2, and T5) experienced a "bloom-and-bust" cycle, with growth ceasing after day 9. In contrast, treatments supplemented with N-P-K fertilizer (T3 and T4) maintained a positive specific growth rate (SGR) throughout the 15-day experimental period (max SGR 0.11–0.23 day⁻¹). This finding provides a practical proof-of-concept demonstrating that a low-energy, bio-inspired lighting strategy is sufficient for cultivating W. globosa in closed systems, provided the plant's fundamental nutrient requirements are satisfied. This study presents a sustainable, energy-efficient alternative to conventional high-intensity lighting methods for aquatic plant production.
- 3 February 2026
- Published by Chiang Mai University in Natural and Life Sciences Communications
- Vol. 25 (3)
Bio-inspired LED Lighting and Nutrient Supplementation for Sustainable Wolffia globosa Cultivation
This study demonstrates an effective cultivation protocol for Wolffia globosa through a bio-inspired approach. Light parameters from the plant's natural, shaded habitats (PPFD ~44 µmol m⁻² s⁻¹) were first characterized to calibrate a laboratory LED system. The experiment revealed that a one-time nutrient supplementation at initiation was the critical factor for sustained growth. While all treatments were exposed to the same light regimen, the unenriched groups (C, T1, T2, and T5) experienced a "bloom-and-bust" cycle, with growth ceasing after day 9. In contrast, treatments supplemented with N-P-K fertilizer (T3 and T4) maintained a positive specific growth rate (SGR) throughout the 15-day experimental period (max SGR 0.11–0.23 day⁻¹). This finding provides a practical proof-of-concept demonstrating that a low-energy, bio-inspired lighting strategy is sufficient for cultivating W. globosa in closed systems, provided the plant's fundamental nutrient requirements are satisfied. This study presents a sustainable, energy-efficient alternative to conventional high-intensity lighting methods for aquatic plant production.
- Open Access
- 2 May 2019
- Published by Wiley in Journal of Electrical and Computer Engineering
- Vol. 2019, 1-14
Implementation of Static Line Voltage Stability Indices for Improved Static Voltage Stability Margin
Nowadays, the changes of economic, environment, and regulations are forcing the electric utilities to operate systems at maximum capacity. Therefore, the operation and control of power system to improve the system stability has been receiving a great deal of attention. This paper presents an approach for enhancing the static voltage stability margin and reducing the power losses of the system with voltage security-constrained optimal power flow (VSC-OPF) that is based on static line voltage stability indices. The control approaches incorporate the voltage stability criteria into the conventional OPF. The minimization of the summation of fast voltage stability index (FVSI), line stability index (Lmn), and line voltage stability index (LVSI) is used as the objective functions. The performance and effectiveness of the proposed control approaches are evaluated on the standard IEEE 30-bus, 57-bus, and 118-bus test systems under normal and contingency conditions. The comparison analysis is carried out with different cases including minimization of generation cost. The proposed control approaches indicate the promising results and offer efficient countermeasures against the voltage instability of the system.
- 2 May 2019
- Published by Wiley in Journal of Electrical and Computer Engineering
- Vol. 2019, 1-14
Open AccessImplementation of Static Line Voltage Stability Indices for Improved Static Voltage Stability Margin
Nowadays, the changes of economic, environment, and regulations are forcing the electric utilities to operate systems at maximum capacity. Therefore, the operation and control of power system to improve the system stability has been receiving a great deal of attention. This paper presents an approach for enhancing the static voltage stability margin and reducing the power losses of the system with voltage security-constrained optimal power flow (VSC-OPF) that is based on static line voltage stability indices. The control approaches incorporate the voltage stability criteria into the conventional OPF. The minimization of the summation of fast voltage stability index (FVSI), line stability index (Lmn), and line voltage stability index (LVSI) is used as the objective functions. The performance and effectiveness of the proposed control approaches are evaluated on the standard IEEE 30-bus, 57-bus, and 118-bus test systems under normal and contingency conditions. The comparison analysis is carried out with different cases including minimization of generation cost. The proposed control approaches indicate the promising results and offer efficient countermeasures against the voltage instability of the system.
- 7 December 2018
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 14 (4) , 534-544
A comparison of the effectiveness of voltage stability indices in an optimal power flow
Voltage stability is very important, as without it voltage collapse will occur. There is therefore a need to incorporate the consideration of voltage stability into the optimal power flow (OPF). This paper presents a comparison of the effectiveness of five voltage stability indices (VSIs) when incorporated in an OPF. The improved particle swarm optimization (IPSO) algorithm is used to solve the OPF problem. The five VSIs investigated are the L‐index, fast voltage stability index (FVSI), line stability index (L mn ), online voltage stability index (LVSI), and voltage collapse proximity indicator (VCPI). The effectiveness of each VSI is considered in the terms of the generation cost, emission, transmission loss, and voltage stability. The IEEE standard 14‐, 30‐, 57‐, and 118‐bus test systems are used for the comparison. It is found that considering each voltage stability index as part of the objective function for the OPF provided different values of generation cost, emission, transmission loss, and maximum loadability. The results suggest that FVSI and L mn provide the minimum generation cost values for all test systems, while VCPI and LVSI provide lower emission values for most systems. VCPI gives the lowest transmission losses for all systems, and the L‐index provides the maximum loadability for most systems. Incorporation of these indices into the OPF can provide the optimal values in different terms, and the most suitable voltage stability index will depend on the situation and size of the system, which needs to be judiciously chosen. © 2018 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.
- 7 December 2018
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 14 (4) , 534-544
A comparison of the effectiveness of voltage stability indices in an optimal power flow
Voltage stability is very important, as without it voltage collapse will occur. There is therefore a need to incorporate the consideration of voltage stability into the optimal power flow (OPF). This paper presents a comparison of the effectiveness of five voltage stability indices (VSIs) when incorporated in an OPF. The improved particle swarm optimization (IPSO) algorithm is used to solve the OPF problem. The five VSIs investigated are the L‐index, fast voltage stability index (FVSI), line stability index (L mn ), online voltage stability index (LVSI), and voltage collapse proximity indicator (VCPI). The effectiveness of each VSI is considered in the terms of the generation cost, emission, transmission loss, and voltage stability. The IEEE standard 14‐, 30‐, 57‐, and 118‐bus test systems are used for the comparison. It is found that considering each voltage stability index as part of the objective function for the OPF provided different values of generation cost, emission, transmission loss, and maximum loadability. The results suggest that FVSI and L mn provide the minimum generation cost values for all test systems, while VCPI and LVSI provide lower emission values for most systems. VCPI gives the lowest transmission losses for all systems, and the L‐index provides the maximum loadability for most systems. Incorporation of these indices into the OPF can provide the optimal values in different terms, and the most suitable voltage stability index will depend on the situation and size of the system, which needs to be judiciously chosen. © 2018 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.
- 1 August 2015
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 781, 288-291
Static Voltage Stability Margin Enhancement Using Shunt Capacitor, SVC and STATCOM
This paper presents the study of static voltage stability margin enhancement using shunt capacitor, SVC and STATCOM. AC and DC representations of shunt compensation devices are used in the continuation power flow process in static voltage stability study. Various performance measures including PV curves, voltage profiles, and power losses are compared. Placement and sizing techniques of shunt compensation devices are proposed for loading margin enhancement. The study has been carried out on the IEEE 14 bus test system.
- 1 August 2015
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 781, 288-291
Static Voltage Stability Margin Enhancement Using Shunt Capacitor, SVC and STATCOM
This paper presents the study of static voltage stability margin enhancement using shunt capacitor, SVC and STATCOM. AC and DC representations of shunt compensation devices are used in the continuation power flow process in static voltage stability study. Various performance measures including PV curves, voltage profiles, and power losses are compared. Placement and sizing techniques of shunt compensation devices are proposed for loading margin enhancement. The study has been carried out on the IEEE 14 bus test system.