Sávio José Cardoso Bezerra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sávio José Cardoso Bezerra has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Taís Scaramucci
Department of Restorative Dentistry, University of São Paulo, Av. Professor Lineu Prestes 2227, São Paulo, SP 05508-000, Brazil
15 shared publications - Samira Helena Niemeyer
Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland
9 shared publications - Ítallo Emídio Lira Viana
Department of Comprehensive Care, Division of Operative Dentistry, Tufts University School of Dental Medicine, Boston, United States
6 shared publications - Alexandre Luiz Souto Borges
Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos 12245-000, SP, Brazil
5 shared publications - Anderson Takeo Hara
Department of Biomedical and Applied Sciences, Oral Health Research Institute, Indiana University School of Dentistry, 415 N Lansing St, Indianapolis, IN 46202, USA
5 shared publications - Ana Cecilia Correa Aranha
Departament of Restorative Dentistry, School of Dentistry University of São Paulo São Paulo Brazil
4 shared publications
Latest Publications
- Open Access
- 17 August 2026
- Published by Wiley in Australian Dental Journal
Evaluation of the Adequate Radiopacity of Cavity Lining/Base and Core Build‐Up Light Cured Composite Resins
Background: This study aimed to compare the radiopacity of composite resins (CR) used as lining, base, and core‐build up materials with enamel and dentine and evaluate their compliance with ISO 4049. Methods: Specimens of 1, 2, and 3 mm thicknesses; ( n = 6) were fabricated from 13 low‐viscosity and 10 regular‐viscosity CRs. Slices of enamel and dentine from human molar crowns (1, 2, and 3 mm, n = 3) were used as references. Five radiographic exposures of all samples were taken and analysed through Welch One‐way ANOVA with Games‐Howell/Dunnett's or Kruskal‐Wallis with Dwass‐Steel‐Critchlow‐Fligner tests regarding viscosity, insertion technique, particle size, filler size and composition. Results: At 1 mm thickness, the mean radiopacity of all materials was above 1 mm aluminium. At all thicknesses, bulk‐fill application technique exhibited significantly higher radiopacity than incremental ( p < 0.001). Regular viscosity composite resins were significantly more radiopaque than low viscosity at 2 mm ( p = 0.013) and 3 mm ( p = 0.005) thicknesses. All tested composite resins complied with ISO 4049 radiopacity requirements. However, for liner and core build‐up applications, radiopacity higher than dentine may be clinically advantageous for reliable radiographic detection. Thus, material selection should consider the intended clinical use, as current ISO criteria may not fully address all restorative purposes.
- 17 August 2026
- Published by Wiley in Australian Dental Journal
Open AccessEvaluation of the Adequate Radiopacity of Cavity Lining/Base and Core Build‐Up Light Cured Composite Resins
Background: This study aimed to compare the radiopacity of composite resins (CR) used as lining, base, and core‐build up materials with enamel and dentine and evaluate their compliance with ISO 4049. Methods: Specimens of 1, 2, and 3 mm thicknesses; ( n = 6) were fabricated from 13 low‐viscosity and 10 regular‐viscosity CRs. Slices of enamel and dentine from human molar crowns (1, 2, and 3 mm, n = 3) were used as references. Five radiographic exposures of all samples were taken and analysed through Welch One‐way ANOVA with Games‐Howell/Dunnett's or Kruskal‐Wallis with Dwass‐Steel‐Critchlow‐Fligner tests regarding viscosity, insertion technique, particle size, filler size and composition. Results: At 1 mm thickness, the mean radiopacity of all materials was above 1 mm aluminium. At all thicknesses, bulk‐fill application technique exhibited significantly higher radiopacity than incremental ( p < 0.001). Regular viscosity composite resins were significantly more radiopaque than low viscosity at 2 mm ( p = 0.013) and 3 mm ( p = 0.005) thicknesses. All tested composite resins complied with ISO 4049 radiopacity requirements. However, for liner and core build‐up applications, radiopacity higher than dentine may be clinically advantageous for reliable radiographic detection. Thus, material selection should consider the intended clinical use, as current ISO criteria may not fully address all restorative purposes.
- Open Access
- 28 April 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (5) , 510
Comparative Analysis of Physical and Mechanical Properties of Acrylic Resins for Interim Fixed Prostheses Under Thermocycling Aging
This study evaluated the physical and mechanical properties of acrylic resins used for interim fixed prostheses, with and without metal reinforcement, before and after aging. A total of 138 samples were divided into three groups: VIPI + Wire (control), VIPI, and Diamond D. Samples were assessed for microhardness, porosity, roughness, and flexural strength. Aging was simulated using 500 thermocycling cycles at 5 and 55 ± 1 °C. Data were analyzed using ANOVA and Tukey’s test. Group Diamond D did not fracture during flexural testing, but it exhibited significantly lower microhardness at both baseline and after aging. Before aging, Group Diamond D had higher roughness than Group VIPI, which exhibited greater porosity. Aging increased the microhardness of Group VIPI and the roughness of Group Diamond D. The percentage of porosity decreased significantly for Groups VIPI + Wire and VIPI, and pore size was reduced in all groups. Based on the results obtained from Diamond D material, this resin does not meet the required properties for the proposed indication for temporary fixed prostheses, whereas VIPI with reinforcement showed superior properties and greater stability after aging.
- 28 April 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (5) , 510
Open AccessComparative Analysis of Physical and Mechanical Properties of Acrylic Resins for Interim Fixed Prostheses Under Thermocycling Aging
This study evaluated the physical and mechanical properties of acrylic resins used for interim fixed prostheses, with and without metal reinforcement, before and after aging. A total of 138 samples were divided into three groups: VIPI + Wire (control), VIPI, and Diamond D. Samples were assessed for microhardness, porosity, roughness, and flexural strength. Aging was simulated using 500 thermocycling cycles at 5 and 55 ± 1 °C. Data were analyzed using ANOVA and Tukey’s test. Group Diamond D did not fracture during flexural testing, but it exhibited significantly lower microhardness at both baseline and after aging. Before aging, Group Diamond D had higher roughness than Group VIPI, which exhibited greater porosity. Aging increased the microhardness of Group VIPI and the roughness of Group Diamond D. The percentage of porosity decreased significantly for Groups VIPI + Wire and VIPI, and pore size was reduced in all groups. Based on the results obtained from Diamond D material, this resin does not meet the required properties for the proposed indication for temporary fixed prostheses, whereas VIPI with reinforcement showed superior properties and greater stability after aging.
- 10 January 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 166, 106503
Synergistic effect of sodium fluoride and encapsulated calcium lactate on dental erosion-abrasion prevention
- 10 January 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 166, 106503
Synergistic effect of sodium fluoride and encapsulated calcium lactate on dental erosion-abrasion prevention
- Open Access
- 12 April 2024
- Published by Universidade Federal do Rio Grande do Sul in Revista da Faculdade de Odontologia de Porto Alegre
- Vol. 65
Produtos clareadores de venda livre:
Objetivo: Revisar a literatura quanto aos efeitos dos produtos de venda livre destinados ao clareamento dental disponíveis no mercado brasileiro. Revisão de literatura: Foram consultadas as bases de dados PubMed, Scielo e Google Scholar, além de busca manual de referências. A incessante busca pelo sorriso perfeito aumenta a procura por procedimentos estéticos, como o clareamento dental, recomendado por cirurgiões-dentistas devido à sua segurança e eficácia comprovadas. Contudo, em meio à demanda por alternativas mais acessíveis e que dispensem o acompanhamento profissional, surgiram no mercado os produtos clareadores de venda livre ou OTC (do inglês over-the-counter), que são opções alternativas ao clareamento profissional. Discussão: A predominância de estudos laboratoriais destaca que a eficácia dos produtos OTC difere dos tratamentos profissionais. Os dentifrícios branqueadores contendo peróxido demonstram eficácia na redução de manchas extrínsecas, com desgaste semelhante ou inferior aos dentifrícios regulares, dependendo do substrato avaliado. Já os enxaguatórios clareadores apresentam evidências limitadas de eficácia em comparação aos produtos de concentrações mais elevadas de peróxido. As receitas caseiras e produtos naturais para clareamento dental mostraram-se ineficazes em comparação aos tratamentos profissionais, levantando preocupações sobre sua segurança devido ao potencial de causar danos irreversíveis à estrutura dental. O carvão ativado não possui efeito clareador, apresenta potencial abrasivo e causa manchamento em mucosa bucal. Conclusão: Produtos clareadores OTC, embora atrativos pela autonomia oferecida, não demonstram, em sua maioria, eficácia significativa, devendo seu uso ser recomendando com cautela, preferencialmente com orientação profissional. Salienta-se a importância da educação contínua para que cirurgiões-dentistas acompanhem as tendências nesse campo.
- 12 April 2024
- Published by Universidade Federal do Rio Grande do Sul in Revista da Faculdade de Odontologia de Porto Alegre
- Vol. 65
Open AccessProdutos clareadores de venda livre:
Objetivo: Revisar a literatura quanto aos efeitos dos produtos de venda livre destinados ao clareamento dental disponíveis no mercado brasileiro. Revisão de literatura: Foram consultadas as bases de dados PubMed, Scielo e Google Scholar, além de busca manual de referências. A incessante busca pelo sorriso perfeito aumenta a procura por procedimentos estéticos, como o clareamento dental, recomendado por cirurgiões-dentistas devido à sua segurança e eficácia comprovadas. Contudo, em meio à demanda por alternativas mais acessíveis e que dispensem o acompanhamento profissional, surgiram no mercado os produtos clareadores de venda livre ou OTC (do inglês over-the-counter), que são opções alternativas ao clareamento profissional. Discussão: A predominância de estudos laboratoriais destaca que a eficácia dos produtos OTC difere dos tratamentos profissionais. Os dentifrícios branqueadores contendo peróxido demonstram eficácia na redução de manchas extrínsecas, com desgaste semelhante ou inferior aos dentifrícios regulares, dependendo do substrato avaliado. Já os enxaguatórios clareadores apresentam evidências limitadas de eficácia em comparação aos produtos de concentrações mais elevadas de peróxido. As receitas caseiras e produtos naturais para clareamento dental mostraram-se ineficazes em comparação aos tratamentos profissionais, levantando preocupações sobre sua segurança devido ao potencial de causar danos irreversíveis à estrutura dental. O carvão ativado não possui efeito clareador, apresenta potencial abrasivo e causa manchamento em mucosa bucal. Conclusão: Produtos clareadores OTC, embora atrativos pela autonomia oferecida, não demonstram, em sua maioria, eficácia significativa, devendo seu uso ser recomendando com cautela, preferencialmente com orientação profissional. Salienta-se a importância da educação contínua para que cirurgiões-dentistas acompanhem as tendências nesse campo.
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 35, e24-5500
The Effect of Actives in Desensitizing and Conventional Mouth Rinses Against Dentin Erosive Wear
This study evaluated the effect of actives present in conventional and desensitizing mouth rinses on the control of dentin erosive tooth wear. Two hundred and seventy dentin specimens from human molars were prepared. The specimens were randomly allocated into 10 experimental groups (n=10): 4 corresponding to desensitizing mouth rinses, 4 to conventional mouth rinses, a negative control group (C-: distilled water), and a positive control group (C+: 500 ppm fluoride plus 800 ppm tin mouth rinse). Specimens were subjected to an erosion-abrasion cycling model: 5 min immersion in 0.3% citric acid and 60 min exposure to artificial saliva. This procedure was repeated 4x/day for 5 days. Immediately after the first and last erosive challenges, the specimens were brushed with a slurry of fluoride toothpaste for 15 s, with a total of 2 min exposure to the slurry. Afterward, the specimens were exposed to the mouth rinses. Dentin surface loss (SL, in µm) was determined by optical profilometry. Data were statistically analyzed by using Kruskal-Wallis and Dunn's tests (α=0.05). The only mouth rinses that presented significantly lower dentin SL than the C- was a desensitizing one containing sodium fluoride (220 ppm F-) with dipotassium oxalate (1.4%) and the C+ (p0.05). Dentin SL of the other groups did not significantly differ from the C- (p>0.05). The combination of sodium fluoride with dipotassium oxalate in a desensitizing mouth rinse showed a promising result against dentin erosive wear, matching the protection offered by a fluoride/tin mouth rinse.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 35, e24-5500
Open AccessThe Effect of Actives in Desensitizing and Conventional Mouth Rinses Against Dentin Erosive Wear
This study evaluated the effect of actives present in conventional and desensitizing mouth rinses on the control of dentin erosive tooth wear. Two hundred and seventy dentin specimens from human molars were prepared. The specimens were randomly allocated into 10 experimental groups (n=10): 4 corresponding to desensitizing mouth rinses, 4 to conventional mouth rinses, a negative control group (C-: distilled water), and a positive control group (C+: 500 ppm fluoride plus 800 ppm tin mouth rinse). Specimens were subjected to an erosion-abrasion cycling model: 5 min immersion in 0.3% citric acid and 60 min exposure to artificial saliva. This procedure was repeated 4x/day for 5 days. Immediately after the first and last erosive challenges, the specimens were brushed with a slurry of fluoride toothpaste for 15 s, with a total of 2 min exposure to the slurry. Afterward, the specimens were exposed to the mouth rinses. Dentin surface loss (SL, in µm) was determined by optical profilometry. Data were statistically analyzed by using Kruskal-Wallis and Dunn's tests (α=0.05). The only mouth rinses that presented significantly lower dentin SL than the C- was a desensitizing one containing sodium fluoride (220 ppm F-) with dipotassium oxalate (1.4%) and the C+ (p0.05). Dentin SL of the other groups did not significantly differ from the C- (p>0.05). The combination of sodium fluoride with dipotassium oxalate in a desensitizing mouth rinse showed a promising result against dentin erosive wear, matching the protection offered by a fluoride/tin mouth rinse.
- 28 March 2023
- Published by Elsevier in Journal of Dentistry
- Vol. 132, 104502
Influence of different ultra-soft toothbrushes on erosive tooth wear
- 28 March 2023
- Published by Elsevier in Journal of Dentistry
- Vol. 132, 104502
Influence of different ultra-soft toothbrushes on erosive tooth wear
- 22 March 2023
- Published by Elsevier in Journal of Dentistry
- Vol. 132, 104498
Tooth color change promoted by different whitening toothpastes under alternate cycles of staining and brushing
- 22 March 2023
- Published by Elsevier in Journal of Dentistry
- Vol. 132, 104498
Tooth color change promoted by different whitening toothpastes under alternate cycles of staining and brushing
- Open Access
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 37, e081
Longitudinal assessment of dental erosion-abrasion by cross-polarization optical coherence tomography in vitro
This study tested a novel in vitro dental erosion-abrasion model and the performance of cross-polarization optical coherence tomography (CP-OCT) in longitudinally monitoring the simulated lesions. Thirty human enamel specimens were prepared and randomized to receive three dental erosion-abrasion (EA) protocols: severe (s-EA, lemon juice/pH:2.5/4.25%w/v citric acid), moderate (m-EA, grapefruit juice/pH:3.5/1.03%w/v citric acid) and no-EA (water, control). EA challenge was performed by exposing the specimens to acidic solutions 4x/day and to brushing 2x/day with 1:3 fluoridated toothpaste slurry, for 14 days. Enamel thickness measurements were obtained using CP-OCT at baseline (D0), 7 (D7) and 14 days (D14) and micro-computed tomography (micro-CT) at D14. Enamel surface loss was measured with both CP-OCT and optical profilometry at D0, D7 and D14. Data was analyzed with repeated-measures ANOVA and Pearson's correlation (r) (α = 0.05). CP-OCT enamel thickness decreased over time in the s-EA group (D0 >D7 > D14, p < 0.001) and m-EA group (D0 > D14, p = 0.019) but did not change in the no-EA group (p = 0.30). Overall, CP-OCT and micro-CT results at D14 correlated moderately (r = 0.73). CP-OCT surface loss was highest for s-EA (p m-EA>s-EA, p < 0.001). D14 surface loss was higher than D7 for both methods except for the no-EA group with profilometry. CP-OCT and profilometry had moderate overall correlation (r = 0.70). Our results revealed that the currently proposed in vitro dental erosion-abrasion model is valid and could simulate lesions of different severities over time. CP-OCT was a suitable method for monitoring the EA lesions.
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 37, e081
Open AccessLongitudinal assessment of dental erosion-abrasion by cross-polarization optical coherence tomography in vitro
This study tested a novel in vitro dental erosion-abrasion model and the performance of cross-polarization optical coherence tomography (CP-OCT) in longitudinally monitoring the simulated lesions. Thirty human enamel specimens were prepared and randomized to receive three dental erosion-abrasion (EA) protocols: severe (s-EA, lemon juice/pH:2.5/4.25%w/v citric acid), moderate (m-EA, grapefruit juice/pH:3.5/1.03%w/v citric acid) and no-EA (water, control). EA challenge was performed by exposing the specimens to acidic solutions 4x/day and to brushing 2x/day with 1:3 fluoridated toothpaste slurry, for 14 days. Enamel thickness measurements were obtained using CP-OCT at baseline (D0), 7 (D7) and 14 days (D14) and micro-computed tomography (micro-CT) at D14. Enamel surface loss was measured with both CP-OCT and optical profilometry at D0, D7 and D14. Data was analyzed with repeated-measures ANOVA and Pearson's correlation (r) (α = 0.05). CP-OCT enamel thickness decreased over time in the s-EA group (D0 >D7 > D14, p < 0.001) and m-EA group (D0 > D14, p = 0.019) but did not change in the no-EA group (p = 0.30). Overall, CP-OCT and micro-CT results at D14 correlated moderately (r = 0.73). CP-OCT surface loss was highest for s-EA (p m-EA>s-EA, p < 0.001). D14 surface loss was higher than D7 for both methods except for the no-EA group with profilometry. CP-OCT and profilometry had moderate overall correlation (r = 0.70). Our results revealed that the currently proposed in vitro dental erosion-abrasion model is valid and could simulate lesions of different severities over time. CP-OCT was a suitable method for monitoring the EA lesions.
- Open Access
- 29 August 2022
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 33 (4) , 54-61
Development of a sodium fluoride and stannous chloride-containing gel for treatment of dental erosion
Resumo Este estudo desenvolveu e testou géis experimentais contendo íons fluoreto (F-) e estanho (Sn2+) para o controle da erosão dentária. Os espécimes polidos, de esmalte e dentina, foram previamente erodidos (solução de ácido cítrico a 1%, 10 min) e alocados aleatoriamente em 5 grupos (n = 10): Placebo - gel de hidroxipropilmetilcelulose (HMC); F + Sn + HMC - 7.500 ppm F- / 15.000 ppm Sn2+; F + HMC - 7.500 ppm F-; Gel de flúor fosfato acidulado comercial (12.300 ppm F-); e Controle - sem tratamento. Após o tratamento (aplicado por 60 s), os espécimes foram submetidos a uma ciclagem de erosão-remineralização (5 min em solução de ácido cítrico a 0,3%, 60 min em saliva artificial, 4 × / dia, 20 dias). A perda de superfície (SL, em µm) foi determinada após o 5º, 10º e 20º dias de ciclagem (α = 0,05). Para o esmalte, após 5 e 10 dias, o F + Sn + HMC apresentou a menor PS, não diferindo do gel comercial. Após 20 dias, não foram encontradas diferenças entre os grupos comercial, F + HMC e F + Sn + HMC. O placebo não diferiu do controle em nenhum momento, e ambos os grupos apresentaram a maior PS, comparado aos demais grupos. Para dentina, no 5º dia , F + Sn + HMC, F + HMC e comercial não diferiram significativamente, apresentando menor PS que o grupo controle e placebo. No 10º dia, F+Sn+HMC e comercial apresentaram a menor PS comparado ao grupo controle e placebo. No 20º dia, apenas o gel comercial apresentou PS menor que o controle e o placebo. Assim, o gel experimental F + Sn + HMC foi capaz de controlar a progressão da erosão dentária.
- 29 August 2022
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 33 (4) , 54-61
Open AccessDevelopment of a sodium fluoride and stannous chloride-containing gel for treatment of dental erosion
Resumo Este estudo desenvolveu e testou géis experimentais contendo íons fluoreto (F-) e estanho (Sn2+) para o controle da erosão dentária. Os espécimes polidos, de esmalte e dentina, foram previamente erodidos (solução de ácido cítrico a 1%, 10 min) e alocados aleatoriamente em 5 grupos (n = 10): Placebo - gel de hidroxipropilmetilcelulose (HMC); F + Sn + HMC - 7.500 ppm F- / 15.000 ppm Sn2+; F + HMC - 7.500 ppm F-; Gel de flúor fosfato acidulado comercial (12.300 ppm F-); e Controle - sem tratamento. Após o tratamento (aplicado por 60 s), os espécimes foram submetidos a uma ciclagem de erosão-remineralização (5 min em solução de ácido cítrico a 0,3%, 60 min em saliva artificial, 4 × / dia, 20 dias). A perda de superfície (SL, em µm) foi determinada após o 5º, 10º e 20º dias de ciclagem (α = 0,05). Para o esmalte, após 5 e 10 dias, o F + Sn + HMC apresentou a menor PS, não diferindo do gel comercial. Após 20 dias, não foram encontradas diferenças entre os grupos comercial, F + HMC e F + Sn + HMC. O placebo não diferiu do controle em nenhum momento, e ambos os grupos apresentaram a maior PS, comparado aos demais grupos. Para dentina, no 5º dia , F + Sn + HMC, F + HMC e comercial não diferiram significativamente, apresentando menor PS que o grupo controle e placebo. No 10º dia, F+Sn+HMC e comercial apresentaram a menor PS comparado ao grupo controle e placebo. No 20º dia, apenas o gel comercial apresentou PS menor que o controle e o placebo. Assim, o gel experimental F + Sn + HMC foi capaz de controlar a progressão da erosão dentária.
- 2 March 2022
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 34 (6) , 933-941
Impact of desensitizing/whitening toothpastes on tooth color change after abrasion and erosion–abrasion
Objective: To evaluate the impact of desensitizing toothpastes (D), their whitening versions (DW) and whitening toothpastes (W) on tooth color change.Methods: Tooth specimens were allocated into 11 groups (n = 10): 1. Artificial saliva (control); 2. Sensodyne Repair & Protect (SRP–D); 3. Sensodyne Repair & Protect Whitening (SRP–DW); 4. Colgate Sensitive Pro‐Relief (CSPR–D); 5. Colgate Sensitive Pro‐Relief Real White (CSPR–DW); 6. Colgate Total 12 (CT12); 7. Colgate Total 12 Whitening (CT12–W); 8. Sensodyne True White (ST–W); 9. Curaprox Black Is White (CB–W); 10.Oral‐B 3D White Perfection (OB3D‐W) and 11. Erosion‐only. They were submitted to two models: A. abrasion; B. erosion/abrasion. Color change (ΔE00), ΔL, Δa, and Δb were determined with a spectrophotometer. Data were statistically evaluated (α = 0.05).Results: For both models, ∆E00 of D did not differ significantly from DW. An overall decrease in luminosity (−∆L) and increase (+∆b) in yellowness of the tooth occurred. In abrasion, all groups reduced redness (−∆a) and only SRP‐DW differed from control (p = 0.016), but for ∆E00, ∆L and ∆b, all toothpastes did not differ from the control. In erosion/abrasion, CB‐W showed significantly lower ∆E00 and ∆b than the control (∆E00: p = 0.026; ∆b: p = 0.005) and SRP‐D (∆E00: p = 0.028; ∆b: p = 0.025). Only SRP‐DW, CSPR‐DW, ST‐W, CB‐W, and erosion‐only had increased redness (+∆a), but none differed from control.Conclusions: The toothpastes did neither promote whitening nor avoid the yellowish aspect of the tooth after abrasion and erosion‐abrasion, regardless of their claim.Clinical significance: Desensitizing and/or whitening toothpastes induced similar changes on tooth color, without promoting whitening effect or reduction in its yellowish aspect.
- 2 March 2022
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 34 (6) , 933-941
Impact of desensitizing/whitening toothpastes on tooth color change after abrasion and erosion–abrasion
Objective: To evaluate the impact of desensitizing toothpastes (D), their whitening versions (DW) and whitening toothpastes (W) on tooth color change.Methods: Tooth specimens were allocated into 11 groups (n = 10): 1. Artificial saliva (control); 2. Sensodyne Repair & Protect (SRP–D); 3. Sensodyne Repair & Protect Whitening (SRP–DW); 4. Colgate Sensitive Pro‐Relief (CSPR–D); 5. Colgate Sensitive Pro‐Relief Real White (CSPR–DW); 6. Colgate Total 12 (CT12); 7. Colgate Total 12 Whitening (CT12–W); 8. Sensodyne True White (ST–W); 9. Curaprox Black Is White (CB–W); 10.Oral‐B 3D White Perfection (OB3D‐W) and 11. Erosion‐only. They were submitted to two models: A. abrasion; B. erosion/abrasion. Color change (ΔE00), ΔL, Δa, and Δb were determined with a spectrophotometer. Data were statistically evaluated (α = 0.05).Results: For both models, ∆E00 of D did not differ significantly from DW. An overall decrease in luminosity (−∆L) and increase (+∆b) in yellowness of the tooth occurred. In abrasion, all groups reduced redness (−∆a) and only SRP‐DW differed from control (p = 0.016), but for ∆E00, ∆L and ∆b, all toothpastes did not differ from the control. In erosion/abrasion, CB‐W showed significantly lower ∆E00 and ∆b than the control (∆E00: p = 0.026; ∆b: p = 0.005) and SRP‐D (∆E00: p = 0.028; ∆b: p = 0.025). Only SRP‐DW, CSPR‐DW, ST‐W, CB‐W, and erosion‐only had increased redness (+∆a), but none differed from control.Conclusions: The toothpastes did neither promote whitening nor avoid the yellowish aspect of the tooth after abrasion and erosion‐abrasion, regardless of their claim.Clinical significance: Desensitizing and/or whitening toothpastes induced similar changes on tooth color, without promoting whitening effect or reduction in its yellowish aspect.