Pai-Shan Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Pai-Shan Chen has a total of 113 co-authors. Here are the top co-authors by number of shared publications:
Jung-Hsuan Chen
Graduate Institute of Toxicology, College of Medicine, National Taiwan University, Taipei, Taiwan, ROC
8 shared publications- Shang-Da Huang
Department of Chemistry, National Tsing Hua University, Hsinchu, Taiwan
7 shared publications Da-Peng Yang
Graduate Institute of Toxicology, College of Medicine, National Taiwan University, Taipei, Taiwan, ROC
4 shared publicationsHuei-Wen Chen
Graduate Institute of Toxicology, College of Medicine, National Taiwan University, Taipei, Taiwan, ROC
4 shared publications- Huei-Wen Chen
Graduate Institute of Toxicology, National Taiwan University, College of Medicine, Taipei, Taiwan
4 shared publications - Pin-Chuan Chen
Department of Mechanical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan
4 shared publications
Latest Publications
Graphitized Mesoporous Nanocomposites Enables Matrix‐Free Soft Ionization for Multi‐Class Drug Screening
The rapid proliferation of over a thousand new psychoactive substances (NPS) presents a growing challenge for global public health and forensic science, due to their structural diversity and widespread illicit use, which significantly complicate analytical detection. In response, a fundamentally reengineered ionization strategy is introduced that integrates mesoporous graphitic‐zeolite nanoparticles (MGNs) with UV‐activated photothermal nanomaterials into a next‐generation surface‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (SALDI‐TOF MS) platform. MGNs—hierarchically structured carbon‐based semiconductors synthesized via chemical vapor deposition—exhibit an exceptionally high surface area (>900 m 2 g −1 ), broadband light absorption, and efficient photothermal energy transfer. These properties collectively enhance desorption and ionization efficiency in the low m/z range (100–500), a region where small‐molecule drug detection is often hindered by matrix interference and low signal fidelity. Compared to conventional organic matrices, the MGN‐based system achieves a 95‐fold improvement in signal‐to‐noise ratio and delivers quantification accuracies exceeding 90% for twelve representative compounds across seven drug classes, including structurally diverse NPS. Mechanistic investigations reveal that localized photothermal heating, in synergy with strong analyte adsorption within the mesoporous framework, accelerates soft ionization while suppressing background noise. This design enables rapid, reproducible, and interference‐free detection—key to real‐time diagnostics and screening applications.
Graphitized Mesoporous Nanocomposites Enables Matrix‐Free Soft Ionization for Multi‐Class Drug Screening
The rapid proliferation of over a thousand new psychoactive substances (NPS) presents a growing challenge for global public health and forensic science, due to their structural diversity and widespread illicit use, which significantly complicate analytical detection. In response, a fundamentally reengineered ionization strategy is introduced that integrates mesoporous graphitic‐zeolite nanoparticles (MGNs) with UV‐activated photothermal nanomaterials into a next‐generation surface‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (SALDI‐TOF MS) platform. MGNs—hierarchically structured carbon‐based semiconductors synthesized via chemical vapor deposition—exhibit an exceptionally high surface area (>900 m 2 g −1 ), broadband light absorption, and efficient photothermal energy transfer. These properties collectively enhance desorption and ionization efficiency in the low m/z range (100–500), a region where small‐molecule drug detection is often hindered by matrix interference and low signal fidelity. Compared to conventional organic matrices, the MGN‐based system achieves a 95‐fold improvement in signal‐to‐noise ratio and delivers quantification accuracies exceeding 90% for twelve representative compounds across seven drug classes, including structurally diverse NPS. Mechanistic investigations reveal that localized photothermal heating, in synergy with strong analyte adsorption within the mesoporous framework, accelerates soft ionization while suppressing background noise. This design enables rapid, reproducible, and interference‐free detection—key to real‐time diagnostics and screening applications.
- Open Access
- 20 February 2025
- Published by Springer Nature in BioChip Journal
- Vol. 19 (2) , 237-247
Additive Manufacturing a One-Piece Microfluidic Device Coupled to Liquid Chromatography–Mass Spectrometry for In Vitro Drug Metabolism Analysis
Understanding the metabolism of drugs is a principal consideration when it comes to understanding the activity of a precursor drug and determining if the precursor is converted into bioactive metabolites after ingestion in the human body. This process is typically studied using either animal models or in vitro models, such as human liver microsomes (HLM). In this research, a novel one-piece microreactor was fabricated with light-curing 3D printing technology, which can be seamlessly and directly integrated with a liquid chromatography–mass spectrometer (LC–MS) system for drug metabolic analysis after an in vitro human liver microsomal reaction. The results clearly showed that: (1) this system was able to conduct metabolic reactions (demonstrated by three commonly abused substances or impurity in illicit heroin including heroin, 6-acetylcodeine, and buprenorphine) at the operation temperature of 37 °C and operation pressure ranging from 7.8 to 21.5 bars, and its performance was very competitive to the conventional method while reducing total processing steps and minimizing manual operation, (2) the integrated LC–MS system demonstrated a high stability and precision where the RSD of chromatographic peak area and retention time was only 2.53% and 0.91%, and (3) the 3D printed reactors, featuring an integrated locking design and a bonded filtration membrane, can significantly enhance usage convenience, reduce specimen process time, and resist high back pressure, potentially advancing drug metabolism studies.
- 20 February 2025
- Published by Springer Nature in BioChip Journal
- Vol. 19 (2) , 237-247
Open AccessAdditive Manufacturing a One-Piece Microfluidic Device Coupled to Liquid Chromatography–Mass Spectrometry for In Vitro Drug Metabolism Analysis
Understanding the metabolism of drugs is a principal consideration when it comes to understanding the activity of a precursor drug and determining if the precursor is converted into bioactive metabolites after ingestion in the human body. This process is typically studied using either animal models or in vitro models, such as human liver microsomes (HLM). In this research, a novel one-piece microreactor was fabricated with light-curing 3D printing technology, which can be seamlessly and directly integrated with a liquid chromatography–mass spectrometer (LC–MS) system for drug metabolic analysis after an in vitro human liver microsomal reaction. The results clearly showed that: (1) this system was able to conduct metabolic reactions (demonstrated by three commonly abused substances or impurity in illicit heroin including heroin, 6-acetylcodeine, and buprenorphine) at the operation temperature of 37 °C and operation pressure ranging from 7.8 to 21.5 bars, and its performance was very competitive to the conventional method while reducing total processing steps and minimizing manual operation, (2) the integrated LC–MS system demonstrated a high stability and precision where the RSD of chromatographic peak area and retention time was only 2.53% and 0.91%, and (3) the 3D printed reactors, featuring an integrated locking design and a bonded filtration membrane, can significantly enhance usage convenience, reduce specimen process time, and resist high back pressure, potentially advancing drug metabolism studies.
- 29 June 2024
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 476, 135020
Wastewater-based epidemiology to monitor 68 NPS/conventional drug use in Taipei metropolitan area in Taiwan during and after COVID-19 pandemic
- 29 June 2024
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 476, 135020
Wastewater-based epidemiology to monitor 68 NPS/conventional drug use in Taipei metropolitan area in Taiwan during and after COVID-19 pandemic
- 1 March 2022
- Published by Oxford University Press (OUP) in Environmental Toxicology and Chemistry
- Vol. 41 (3) , 715-725
Monitoring Phthalates in Maternal and Cord Blood: Implications for Prenatal Exposure and Birth Outcomes
Although many phthalates are endocrine-disrupting chemicals that are associated with adverse birth outcomes, the relationship between maternal phthalate exposure and birth outcomes is not yet conclusive. The objective of the present study was to investigate the association between prenatal exposure to phthalates in human maternal and cord blood and birth outcomes of the infants. Sixty-five mother–infant pairs were recruited in Taipei City and New Taipei City, and birth outcomes of the infants were recorded. Twelve phthalate metabolites were measured in maternal and cord blood samples. The mean of mono-ethyl phthalate, mono-isobutyl phthalate (MiBP), mono-n-butyl phthalate (MnBP), and mono-(2-ethylhexyl) phthalate (MEHP) was relatively higher than that of the other metabolites in both maternal and infant blood. There was a significant difference (p < 0.05) for mono-methyl phthalate (MMP) and MnBP between the maternal blood and cord blood of male infants. Mono-benzyl phthalate (MBzP), MMP, MiBP, and ∑di-2-ethylhexyl phthalate (∑DEHP) in maternal blood were inversely correlated with the anogenital index (AGI) of male infants, with a p value between 0.011 and 0.033. Mono-n-octyl phthalate, MMP, MiBP, MnBP, and MBzP were positively correlated with the AGI of female infants, with a p value between 0.001 and 0.034. Cord blood levels of MnBP, mono-(2-ethyl-5-oxohexyl)-phthalate, MEHP, and ∑DEHP were found to be inversely associated with head circumference in all the infants, adjusted for gestational age. Phthalate monoesters are potentially estrogenic and antiandrogenic chemicals. Longitudinal follow-up of the present study population could help clarify the long-term impact of phthalates on growth and the health effects of background exposure levels. Environ Toxicol Chem 2022;41:715–725. © 2022 SETAC Abstract Monitoring phthalates in maternal and cord blood for birth outcomes.
- 1 March 2022
- Published by Oxford University Press (OUP) in Environmental Toxicology and Chemistry
- Vol. 41 (3) , 715-725
Monitoring Phthalates in Maternal and Cord Blood: Implications for Prenatal Exposure and Birth Outcomes
Although many phthalates are endocrine-disrupting chemicals that are associated with adverse birth outcomes, the relationship between maternal phthalate exposure and birth outcomes is not yet conclusive. The objective of the present study was to investigate the association between prenatal exposure to phthalates in human maternal and cord blood and birth outcomes of the infants. Sixty-five mother–infant pairs were recruited in Taipei City and New Taipei City, and birth outcomes of the infants were recorded. Twelve phthalate metabolites were measured in maternal and cord blood samples. The mean of mono-ethyl phthalate, mono-isobutyl phthalate (MiBP), mono-n-butyl phthalate (MnBP), and mono-(2-ethylhexyl) phthalate (MEHP) was relatively higher than that of the other metabolites in both maternal and infant blood. There was a significant difference (p < 0.05) for mono-methyl phthalate (MMP) and MnBP between the maternal blood and cord blood of male infants. Mono-benzyl phthalate (MBzP), MMP, MiBP, and ∑di-2-ethylhexyl phthalate (∑DEHP) in maternal blood were inversely correlated with the anogenital index (AGI) of male infants, with a p value between 0.011 and 0.033. Mono-n-octyl phthalate, MMP, MiBP, MnBP, and MBzP were positively correlated with the AGI of female infants, with a p value between 0.001 and 0.034. Cord blood levels of MnBP, mono-(2-ethyl-5-oxohexyl)-phthalate, MEHP, and ∑DEHP were found to be inversely associated with head circumference in all the infants, adjusted for gestational age. Phthalate monoesters are potentially estrogenic and antiandrogenic chemicals. Longitudinal follow-up of the present study population could help clarify the long-term impact of phthalates on growth and the health effects of background exposure levels. Environ Toxicol Chem 2022;41:715–725. © 2022 SETAC Abstract Monitoring phthalates in maternal and cord blood for birth outcomes.
- Open Access
- 1 February 2022
- Published by Elsevier in Regulatory Toxicology and Pharmacology
- Vol. 128, 105097
A proposed approach to confirm heroin administration – Regional differences in heroin purity is a major factor
- 1 February 2022
- Published by Elsevier in Regulatory Toxicology and Pharmacology
- Vol. 128, 105097
Open AccessA proposed approach to confirm heroin administration – Regional differences in heroin purity is a major factor
- Open Access
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Drug Surveillance in High-Risk Population Based on Analytical Confirmation, Questionnaires, and Criminal Investigations: A Longitudinal Study in Taiwan between 2014 and 2018
Background: The continual emergence of new synthetic drugs can lead to rapid changes in drug prevalence patterns. The diversity of synthetic drugs challenges current approaches to drug monitoring, control, and responses. In this study, we combined drugs analysis using liquid chromatography-mass spectrometry, questionnaires from abusers, and information from criminal investigations to construct a comprehensive landscape of drug abuse and develop strategies for drug control. Methods: The urine samples (n=3,064) analyzed in the present study were randomly selected from the database of suspected drug abusers apprehended by police between August 2014 to July 2018 in Taiwan (N=6,335). Then the results were compared with a detailed list of drugs recently seized by border/police force. Demographic factors were self-reported by suspected abusers, and the place and means of arrest were provided by police. In advance, principal component analysis (PCA) were used to explore the drug using pattern among the suspected drug abusers. Findings: Most samples (93.44%) contained 1 to 16 drugs, in which amphetamines, opioids, ketamine, new psychoactive substances (NPS), and benzodiazepines were the top 5 appeared ones. The positive detection of NPS (not including ketamine) reached 19.6%. Principal component analysis (PCA) revealed that people tended to use amphetamines or ketamine might be in different sub-population since their using patterns of amphetamines and ketamine were in opposite direction of PC2 axis. In addition, opioid-users might seldom use other drugs since the opioid vector was close to orthogonal to the plane of amphetamines and ketamine users. Subjects with high PC3 score indicated the high preference of polydrug use. We observed the following links: phenethylamines and the co-use of amphetamines (aOR 4.33), benzodiazepines (aOR 2.09), and synthetic cathinones (aOR 5.01); piperazines and the co-use of benzodiazepines (aOR 2.26) and synthetic cathinones (aOR 3.22); and synthetic cathinones and the co-use of ketamine (aOR 6.72) and benzodiazepines (aOR 2.62). We also found that phenethylamines were associated with the means of investigation (aOR 0.27 for extended or due-to-case investigation). Interpretation: We obtained no evidence indicating an increase in the use of NPS or other substances as a replacement for traditional drugs. The presence of polydrug patterns may be due to similarities in the effects of the various drugs or users undergoing a transition in their drug abuse patterns. We observed a correlation between urine analysis and the quantity of drugs seized by border/police force. This indicates that updating drug lists could assist in monitoring drug prevalence and provide instantaneous feedback pertaining to the effectiveness of drug control systems. Funding Information: This work was supported by Taiwan Food and Drug Administration and Ministry of Science and Technology. Declaration of Interests: We declare no competing interests.
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Open AccessDrug Surveillance in High-Risk Population Based on Analytical Confirmation, Questionnaires, and Criminal Investigations: A Longitudinal Study in Taiwan between 2014 and 2018
Background: The continual emergence of new synthetic drugs can lead to rapid changes in drug prevalence patterns. The diversity of synthetic drugs challenges current approaches to drug monitoring, control, and responses. In this study, we combined drugs analysis using liquid chromatography-mass spectrometry, questionnaires from abusers, and information from criminal investigations to construct a comprehensive landscape of drug abuse and develop strategies for drug control. Methods: The urine samples (n=3,064) analyzed in the present study were randomly selected from the database of suspected drug abusers apprehended by police between August 2014 to July 2018 in Taiwan (N=6,335). Then the results were compared with a detailed list of drugs recently seized by border/police force. Demographic factors were self-reported by suspected abusers, and the place and means of arrest were provided by police. In advance, principal component analysis (PCA) were used to explore the drug using pattern among the suspected drug abusers. Findings: Most samples (93.44%) contained 1 to 16 drugs, in which amphetamines, opioids, ketamine, new psychoactive substances (NPS), and benzodiazepines were the top 5 appeared ones. The positive detection of NPS (not including ketamine) reached 19.6%. Principal component analysis (PCA) revealed that people tended to use amphetamines or ketamine might be in different sub-population since their using patterns of amphetamines and ketamine were in opposite direction of PC2 axis. In addition, opioid-users might seldom use other drugs since the opioid vector was close to orthogonal to the plane of amphetamines and ketamine users. Subjects with high PC3 score indicated the high preference of polydrug use. We observed the following links: phenethylamines and the co-use of amphetamines (aOR 4.33), benzodiazepines (aOR 2.09), and synthetic cathinones (aOR 5.01); piperazines and the co-use of benzodiazepines (aOR 2.26) and synthetic cathinones (aOR 3.22); and synthetic cathinones and the co-use of ketamine (aOR 6.72) and benzodiazepines (aOR 2.62). We also found that phenethylamines were associated with the means of investigation (aOR 0.27 for extended or due-to-case investigation). Interpretation: We obtained no evidence indicating an increase in the use of NPS or other substances as a replacement for traditional drugs. The presence of polydrug patterns may be due to similarities in the effects of the various drugs or users undergoing a transition in their drug abuse patterns. We observed a correlation between urine analysis and the quantity of drugs seized by border/police force. This indicates that updating drug lists could assist in monitoring drug prevalence and provide instantaneous feedback pertaining to the effectiveness of drug control systems. Funding Information: This work was supported by Taiwan Food and Drug Administration and Ministry of Science and Technology. Declaration of Interests: We declare no competing interests.
- Open Access
- 19 October 2021
- Published by MDPI AG in Pharmaceutics
- Vol. 13 (10) , 1728
Optimization and Development of Selective Histone Deacetylase Inhibitor (MPT0B291)-Loaded Albumin Nanoparticles for Anticancer Therapy
Histone deacetylase (HDAC) inhibitors have emerged as a new class of antitumor agent for various types of tumors. MPT0B291, a novel selective inhibitor of HDAC6, demonstrated significant antiproliferative activity in various human cancer cell types. However, MPT0B291 has very low water solubility, which limits its clinical use for cancer therapy. In the current study, MPT0B291 was encapsulated in human serum albumin (HSA), and its anticancer activities were investigated. Nanoparticles (NPs) were prepared using two-stage emulsification resulting in 100~200-nm NPs with a fine size distribution (polydispersity index of t1/2) leading to significantly enhanced efficacy of anticancer treatment.
- 19 October 2021
- Published by MDPI AG in Pharmaceutics
- Vol. 13 (10) , 1728
Open AccessOptimization and Development of Selective Histone Deacetylase Inhibitor (MPT0B291)-Loaded Albumin Nanoparticles for Anticancer Therapy
Histone deacetylase (HDAC) inhibitors have emerged as a new class of antitumor agent for various types of tumors. MPT0B291, a novel selective inhibitor of HDAC6, demonstrated significant antiproliferative activity in various human cancer cell types. However, MPT0B291 has very low water solubility, which limits its clinical use for cancer therapy. In the current study, MPT0B291 was encapsulated in human serum albumin (HSA), and its anticancer activities were investigated. Nanoparticles (NPs) were prepared using two-stage emulsification resulting in 100~200-nm NPs with a fine size distribution (polydispersity index of t1/2) leading to significantly enhanced efficacy of anticancer treatment.
- Open Access
Development of an Automated Optical Inspection System for Rapidly and Precisely Measuring Dimensions of Embedded Microchannel Structures in Transparent Bonded Chips
This study aimed to develop an automated optical inspection (AOI) system that can rapidly and precisely measure the dimensions of microchannels embedded inside a transparent polymeric substrate, and can eventually be used on the production line of a factory. The AOI system is constructed based on Snell’s law. The concept holds that, when light travels through two transparent media (air and the microfluidic chip transparent material), by capturing the parallel refracted light from a light source that went through the microchannel using a camera with a telecentric lens, the image can be analyzed using formulas derived from Snell’s law to measure the dimensions of the microchannel cross-section. Through the NI LabVIEW 2018 SP1 programming interface, we programmed this system to automatically analyze the captured image and acquire all the needed data. The system then processes these data using custom-developed formulas to calculate the height and width measurements of the microchannel cross-sections and presents the results on the human–machine interface (HMI). In this study, a single and straight microchannel with a cross-sectional area of 300 μm × 300 μm and length of 44 mm was micromachined and sealed with another polymeric substrate by a solvent bonding method for experimentations. With this system, 45 cross-sectional areas along the straight microchannel were measured within 20 s, and experiment results showed that the average measured error was less than 2%.
Open AccessDevelopment of an Automated Optical Inspection System for Rapidly and Precisely Measuring Dimensions of Embedded Microchannel Structures in Transparent Bonded Chips
This study aimed to develop an automated optical inspection (AOI) system that can rapidly and precisely measure the dimensions of microchannels embedded inside a transparent polymeric substrate, and can eventually be used on the production line of a factory. The AOI system is constructed based on Snell’s law. The concept holds that, when light travels through two transparent media (air and the microfluidic chip transparent material), by capturing the parallel refracted light from a light source that went through the microchannel using a camera with a telecentric lens, the image can be analyzed using formulas derived from Snell’s law to measure the dimensions of the microchannel cross-section. Through the NI LabVIEW 2018 SP1 programming interface, we programmed this system to automatically analyze the captured image and acquire all the needed data. The system then processes these data using custom-developed formulas to calculate the height and width measurements of the microchannel cross-sections and presents the results on the human–machine interface (HMI). In this study, a single and straight microchannel with a cross-sectional area of 300 μm × 300 μm and length of 44 mm was micromachined and sealed with another polymeric substrate by a solvent bonding method for experimentations. With this system, 45 cross-sectional areas along the straight microchannel were measured within 20 s, and experiment results showed that the average measured error was less than 2%.