Guanhua Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Guanhua Lin has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
Gang Chen
Strait Laboratory of Flexible Electronics (SLoFE), Fujian Key Laboratory of Flexible Electronics, and Strait Institute of Flexible Electronics (SIFE, Future Technologies)
7 shared publicationsHaifei Wang
State Key Laboratory of Radio Frequency Heterogeneous Integration College of Physics and Optoelectronic Engineering Shenzhen University Shenzhen 518060 China
6 shared publicationsShuo Wang
Future Technology School
6 shared publications- Yongxiang Gao
Institute for Advanced Study Shenzhen University 518060 Shenzhen P.R. China
6 shared publications - Wensheng Lu
College of Civil Engineering Tongji University Shanghai China
5 shared publications Moyi Xie
Strait Laboratory of Flexible Electronics (SLoFE), Fujian Key Laboratory of Flexible Electronics, and Strait Institute of Flexible Electronics (SIFE, Future Technologies)
4 shared publications
Latest Publications
- 24 April 2026
- Published by Elsevier in Progress in Materials Science
- Vol. 162
In-situ transmission electron microscopy reveals dynamics of nanostructures
- 24 April 2026
- Published by Elsevier in Progress in Materials Science
- Vol. 162
In-situ transmission electron microscopy reveals dynamics of nanostructures
- 23 December 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (1) , 1118-1128
Anisotropic Growth of Amorphous Structures via Interfacial Self-Assembly of Hydrophobic Gold Nanoparticles for Reliable and Accurate Detection of Pesticide Residues
Recently, amorphous nanomaterials with unique structural features that crystalline materials may lack such as long-range atomic disorder have attracted great attention due to their outstanding surface-enhanced Raman scattering (SERS) properties. Herein, uniform hydrophobic gold nanoparticles (4.4 ± 0.95 nm) have been fabricated for realizing dodecylamine-assisted interfacial self-assembly at the air-water interface of Langmuir-Blodgett (LB) instruments for producing disordered amorphous disc superstructures, with their diameter ranging from ∼200 to ∼700 nm and height within 10-15 nm. When the surface tension of the air-water interface is increased from 0 to 10 and 20 mN/m, they can be linked together to form disc chains and networks, respectively. Interestingly, in the absence of free dodecylamine, these dodecylamine-stabilized hydrophobic gold nanoparticles will form highly ordered hexagonal close-packed monolayer films. Significantly, these amorphous disk superstructures possess better SERS performance than the ordered monolayer films. Further studies suggest that amorphous disc superstructures prepared for SERS sensors have advantages of low limit of detection (0.032 nM), excellent long-term stability, and a wide linear range (0.01-1000.0 nM) for detecting acetamiprid. Furthermore, they display splendid SERS performance for rapid determination of acetamiprid residues on the surface of apples, showing their ability for reliable and accurate detection of pesticide residues in real samples. Our research provides an effective approach for preparing amorphous structures via interfacial self-assembly, which reveals promising application prospects for detecting pesticide residues in real food samples.
- 23 December 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (1) , 1118-1128
Anisotropic Growth of Amorphous Structures via Interfacial Self-Assembly of Hydrophobic Gold Nanoparticles for Reliable and Accurate Detection of Pesticide Residues
Recently, amorphous nanomaterials with unique structural features that crystalline materials may lack such as long-range atomic disorder have attracted great attention due to their outstanding surface-enhanced Raman scattering (SERS) properties. Herein, uniform hydrophobic gold nanoparticles (4.4 ± 0.95 nm) have been fabricated for realizing dodecylamine-assisted interfacial self-assembly at the air-water interface of Langmuir-Blodgett (LB) instruments for producing disordered amorphous disc superstructures, with their diameter ranging from ∼200 to ∼700 nm and height within 10-15 nm. When the surface tension of the air-water interface is increased from 0 to 10 and 20 mN/m, they can be linked together to form disc chains and networks, respectively. Interestingly, in the absence of free dodecylamine, these dodecylamine-stabilized hydrophobic gold nanoparticles will form highly ordered hexagonal close-packed monolayer films. Significantly, these amorphous disk superstructures possess better SERS performance than the ordered monolayer films. Further studies suggest that amorphous disc superstructures prepared for SERS sensors have advantages of low limit of detection (0.032 nM), excellent long-term stability, and a wide linear range (0.01-1000.0 nM) for detecting acetamiprid. Furthermore, they display splendid SERS performance for rapid determination of acetamiprid residues on the surface of apples, showing their ability for reliable and accurate detection of pesticide residues in real samples. Our research provides an effective approach for preparing amorphous structures via interfacial self-assembly, which reveals promising application prospects for detecting pesticide residues in real food samples.
- 17 July 2025
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (1)
Accurate and Reliable Detection of Dynamic Electrophysiological Signals via In Situ Formation of Epidermal Electrodes
Accurate and reliable monitoring of dynamic electrophysiological signals is essential for advancing human health. However, gaps and relative movements between the detection electrodes and human skin can severely interfere the accuracy and stability of acquired bioelectrical signals. Here, an approach to rapidly form a stable bioelectronic interface through an in situ self‐catalytic reaction at the interface between an organogel electrode and the epidermal tissue of skin, referred to as the epidermisgel interlocking electrode (EGIE), is proposed. Significantly, the electrode with an interlocking structure exhibits superior interfacial adhesion, excellent epidermal conformability, outstanding mechanical stability, stable electrochemical performance, and good biocompatibility. Accurate and reliable detection of electrocardiogram (ECG) signals during walking, squatting, jogging, and post‐sweating, as well as electromyogram (EMG) signals during leg stretching exercises and running activities, is achieved with a signal‐to‐noise ratio of 21.83 ± 0.12 dB. An EGIE‐enabled ECG wear is further developed for multi‐parameter physiological monitoring during dynamic human activities, which demonstrates the promising application of the proposed method.
- 17 July 2025
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (1)
Accurate and Reliable Detection of Dynamic Electrophysiological Signals via In Situ Formation of Epidermal Electrodes
Accurate and reliable monitoring of dynamic electrophysiological signals is essential for advancing human health. However, gaps and relative movements between the detection electrodes and human skin can severely interfere the accuracy and stability of acquired bioelectrical signals. Here, an approach to rapidly form a stable bioelectronic interface through an in situ self‐catalytic reaction at the interface between an organogel electrode and the epidermal tissue of skin, referred to as the epidermisgel interlocking electrode (EGIE), is proposed. Significantly, the electrode with an interlocking structure exhibits superior interfacial adhesion, excellent epidermal conformability, outstanding mechanical stability, stable electrochemical performance, and good biocompatibility. Accurate and reliable detection of electrocardiogram (ECG) signals during walking, squatting, jogging, and post‐sweating, as well as electromyogram (EMG) signals during leg stretching exercises and running activities, is achieved with a signal‐to‐noise ratio of 21.83 ± 0.12 dB. An EGIE‐enabled ECG wear is further developed for multi‐parameter physiological monitoring during dynamic human activities, which demonstrates the promising application of the proposed method.
- 9 May 2025
- Published by Elsevier in Journal of Power Sources
- Vol. 646
2D CuO materials with superior photoelectrochemical performances for water splitting
- 9 May 2025
- Published by Elsevier in Journal of Power Sources
- Vol. 646
2D CuO materials with superior photoelectrochemical performances for water splitting
- 26 March 2025
- Published by Elsevier in Advances in Colloid and Interface Science
- Vol. 341, 103490
A comprehensive understanding on droplets
- 26 March 2025
- Published by Elsevier in Advances in Colloid and Interface Science
- Vol. 341, 103490
A comprehensive understanding on droplets
- 3 March 2025
- Published by Elsevier in Journal of Power Sources
- Vol. 639
Structure engineering and controllable synthesis of urchin-like Cu(OH)2 electrocatalyst for simulated seawater oxidation
- 3 March 2025
- Published by Elsevier in Journal of Power Sources
- Vol. 639
Structure engineering and controllable synthesis of urchin-like Cu(OH)2 electrocatalyst for simulated seawater oxidation
- 14 February 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (8) , 11888-11897
Flexible Alternating-Current Electroluminescent Devices for Reliable Identification of Fingerprints
Flexible bioelectronic devices, which can directly detect various external stimuli or biosignals and communicate the information to the users, have been broadly investigated due to the increasing demand for wearable devices. Among them, alternating-current electroluminescence (ACEL) devices are proposed as sensitive sensing systems for various targets, such as fingerprints. Herein, we propose a method for preparing high-performance ACEL devices by using an Ag electrode, polyethylene terephthalate (PET) substrate, FKM/EMI ionogel, and ZnS:Cu/BaTiO3/Ecoflex emissive layer. Their influence has also been studied for achieving high performances. The results demonstrate that the prepared ACEL devices can achieve high performances of emitting bright green and blue light when contacted with various ionic liquids. Significantly, they achieved good sensing performance for detecting Na+ with a limit of detection at 17.1 μM in the linear range of 100-800 mM. Moreover, the ACEL devices can be used for identity recognition, as they are capable of efficient collection and distinguishing of fingerprints. Even the characteristics of fingerprints collected from bending surfaces or contaminated fingers could be distinguished by the naked eyes. Compared with commercial fingerprint devices, our ACEL devices exhibit superior performance in fingerprint identification. High-resolution and three-dimensional image analysis further validates the reliability of our ACEL devices in fingerprint collection and identification. As such, we believe that the designed ACEL devices have very promising application prospects in many fields.
- 14 February 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (8) , 11888-11897
Flexible Alternating-Current Electroluminescent Devices for Reliable Identification of Fingerprints
Flexible bioelectronic devices, which can directly detect various external stimuli or biosignals and communicate the information to the users, have been broadly investigated due to the increasing demand for wearable devices. Among them, alternating-current electroluminescence (ACEL) devices are proposed as sensitive sensing systems for various targets, such as fingerprints. Herein, we propose a method for preparing high-performance ACEL devices by using an Ag electrode, polyethylene terephthalate (PET) substrate, FKM/EMI ionogel, and ZnS:Cu/BaTiO3/Ecoflex emissive layer. Their influence has also been studied for achieving high performances. The results demonstrate that the prepared ACEL devices can achieve high performances of emitting bright green and blue light when contacted with various ionic liquids. Significantly, they achieved good sensing performance for detecting Na+ with a limit of detection at 17.1 μM in the linear range of 100-800 mM. Moreover, the ACEL devices can be used for identity recognition, as they are capable of efficient collection and distinguishing of fingerprints. Even the characteristics of fingerprints collected from bending surfaces or contaminated fingers could be distinguished by the naked eyes. Compared with commercial fingerprint devices, our ACEL devices exhibit superior performance in fingerprint identification. High-resolution and three-dimensional image analysis further validates the reliability of our ACEL devices in fingerprint collection and identification. As such, we believe that the designed ACEL devices have very promising application prospects in many fields.
- 14 November 2024
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 8 (18) , 9120-9129
Ordered 2D Gold Nanoparticle Films for Sensing of Toluene and Ethanol Gases
- 14 November 2024
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 8 (18) , 9120-9129
Ordered 2D Gold Nanoparticle Films for Sensing of Toluene and Ethanol Gases
- 23 April 2024
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 668, 142-153
Developing excellent plantar pressure sensors for monitoring human motions by using highly compressible and resilient PMMA conductive iongels
- 23 April 2024
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 668, 142-153
Developing excellent plantar pressure sensors for monitoring human motions by using highly compressible and resilient PMMA conductive iongels