Steve Sungwon Cho
Steve Sungwon Cho has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Jin Pyeong Jeon
Department of Neurosurgery, Hallym University College of Medicine, Chuncheon, Korea
3 shared publications - John Y. K. Lee
Department of Neurosurgery at the Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
3 shared publications - Hyuk Jai Choi
Department of Neurosurgery, Hallym University College of Medicine, Chuncheon, Korea
2 shared publications - Jin Seo Yang
Department of Neurosurgery, Chuncheon Sacred Heart Hospital, Hallym University College of Medicine, Chuncheon, Republic of Korea
2 shared publications - Suk Hyung Kang
Department of Neurosurgery, Kyung Hee University Hospital, College of Medicine, Kyung Hee University, Seoul, Korea
2 shared publications - Bong Jun Kim
Hallym Univ, Inst New Frontier Res, Coll Med, Chunchon, South Korea
1 shared publication
Latest Publications
- 23 September 2025
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 30 (6) , 994-995
Unilateral Biportal Endoscopic Transforaminal Lumbar Interbody Fusion Using the Modified Trans-Kambin's Triangle Approach: 2-Dimensional Operative Video
- 23 September 2025
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 30 (6) , 994-995
Unilateral Biportal Endoscopic Transforaminal Lumbar Interbody Fusion Using the Modified Trans-Kambin's Triangle Approach: 2-Dimensional Operative Video
- Open Access
- 1 July 2022
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 65 (4) , 572-581
Assessment and Comparison of Three Dimensional Exoscopes for Near-Infrared Fluorescence-Guided Surgery Using Second-Window Indocyanine-Green
Objective : Compared to microscopes, exoscopes have advantages in field-depth, ergonomics, and educational value. Exoscopes are especially well-poised for adaptation into fluorescence-guided surgery (FGS) due to their excitation source, light path, and image processing capabilities. We evaluated the feasibility of near-infrared FGS using a 3-dimensional (3D), 4 K exoscope with nearinfrared fluorescence imaging capability. We then compared it to the most sensitive, commercially-available near-infrared exoscope system (3D and 960 p). In-vitro and intraoperative comparisons were performed.Methods : Serial dilutions of indocyanine-green (1–2000 μg/mL) were imaged with the 3D, 4 K Olympus Orbeye (system 1) and the 3D, 960 p VisionSense Iridium (system 2). Near-infrared sensitivity was calculated using signal-to-background ratios (SBRs). In addition, three patients with brain tumors were administered indocyanine-green and imaged with system 1, with two also imaged with system 2 for comparison.Results : Systems 1 and 2 detected near-infrared fluorescence from indocyanine green concentrations of >250 μg/L and >31.3 μg/L, respectively. Intraoperatively, system 1 visualized strong near-infrared fluorescence from two, strongly gadoliniumenhancing meningiomas (SBR=2.4, 1.7). The high-resolution, bright images were sufficient for the surgeon to appreciate the underlying anatomy in the near-infrared mode. However, system 1 was not able to visualize fluorescence from a weakly-enhancing intraparenchymal metastasis. In contrast, system 2 successfully visualized both the meningioma and the metastasis but lacked high resolution stereopsis.Conclusion : Three-dimensional exoscope systems provide an alternative visualization platform for both standard microsurgery and near-infrared fluorescent guided surgery. However, when tumor fluorescence is weak (i.e., low fluorophore uptake, deep tumors), highly sensitive near-infrared visualization systems may be required.
- 1 July 2022
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 65 (4) , 572-581
Open AccessAssessment and Comparison of Three Dimensional Exoscopes for Near-Infrared Fluorescence-Guided Surgery Using Second-Window Indocyanine-Green
Objective : Compared to microscopes, exoscopes have advantages in field-depth, ergonomics, and educational value. Exoscopes are especially well-poised for adaptation into fluorescence-guided surgery (FGS) due to their excitation source, light path, and image processing capabilities. We evaluated the feasibility of near-infrared FGS using a 3-dimensional (3D), 4 K exoscope with nearinfrared fluorescence imaging capability. We then compared it to the most sensitive, commercially-available near-infrared exoscope system (3D and 960 p). In-vitro and intraoperative comparisons were performed.Methods : Serial dilutions of indocyanine-green (1–2000 μg/mL) were imaged with the 3D, 4 K Olympus Orbeye (system 1) and the 3D, 960 p VisionSense Iridium (system 2). Near-infrared sensitivity was calculated using signal-to-background ratios (SBRs). In addition, three patients with brain tumors were administered indocyanine-green and imaged with system 1, with two also imaged with system 2 for comparison.Results : Systems 1 and 2 detected near-infrared fluorescence from indocyanine green concentrations of >250 μg/L and >31.3 μg/L, respectively. Intraoperatively, system 1 visualized strong near-infrared fluorescence from two, strongly gadoliniumenhancing meningiomas (SBR=2.4, 1.7). The high-resolution, bright images were sufficient for the surgeon to appreciate the underlying anatomy in the near-infrared mode. However, system 1 was not able to visualize fluorescence from a weakly-enhancing intraparenchymal metastasis. In contrast, system 2 successfully visualized both the meningioma and the metastasis but lacked high resolution stereopsis.Conclusion : Three-dimensional exoscope systems provide an alternative visualization platform for both standard microsurgery and near-infrared fluorescent guided surgery. However, when tumor fluorescence is weak (i.e., low fluorophore uptake, deep tumors), highly sensitive near-infrared visualization systems may be required.
- Open Access
- 1 November 2020
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 63 (6) , 806-813
A Prospective Observational Study of Return to Work after Single Level Lumbar Discectomy
Objective : Lumbar disc herniation (LDH) is a common disease, and lumbar discectomy (LD) is a common neurosurgical procedure. However, there is little previous data on return to work (RTW) after LD. This study investigated the period until the RTW after LD prospectively. Clinically, the pain state at the time of RTW also checked. RTW failure rate 6 months after surgery also investigated. Methods : Patients with daily/regular jobs undergoing LD between September 2014 and December 2018 were enrolled. Pain was assessed by the Oswestri Disability Index (ODI) and the Numeric Rate Scale (NRS). Employment type was divided into self-employed, regular and contracted. Monthly telephone interviews were conducted to check RTW status and self-estimated work capability after surgery. Results : Sixty-seven patients enrolled in this study. Three patients failed to RTW, and three others resigned within 6 months after surgery. The preoperative NRS and ODI were 7.2±1.2 and 22.1±7.9, respectively. The average time to RTW was 5.1±6.0 weeks. At RTW, NRS was 1.5±1.8 and ODI was 6.3±3.9. Amongst patients that successfully returned to work were 16 self-employed workers, 42 regular employees, and three contracted workers. The time to RTW of self-employed, regular, and contracted workers were 5.9±8.8, 4.2±4.3 and 13.3±2.3 weeks, respectively (p=0.011). Thirty-six of the patients that returned to work self-reported a 22.8±15.6% reduction in work capability at 6 months. Conclusion : RTW may vary depending on the employment status. In this study, we found that while employment type may affect the length to RTW, most patients were able to RTW and >40% of patients reported no loss of work capabilities 6 months postoperatively, hopefully alleviating some patient hesitation towards LD.
- 1 November 2020
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 63 (6) , 806-813
Open AccessA Prospective Observational Study of Return to Work after Single Level Lumbar Discectomy
Objective : Lumbar disc herniation (LDH) is a common disease, and lumbar discectomy (LD) is a common neurosurgical procedure. However, there is little previous data on return to work (RTW) after LD. This study investigated the period until the RTW after LD prospectively. Clinically, the pain state at the time of RTW also checked. RTW failure rate 6 months after surgery also investigated. Methods : Patients with daily/regular jobs undergoing LD between September 2014 and December 2018 were enrolled. Pain was assessed by the Oswestri Disability Index (ODI) and the Numeric Rate Scale (NRS). Employment type was divided into self-employed, regular and contracted. Monthly telephone interviews were conducted to check RTW status and self-estimated work capability after surgery. Results : Sixty-seven patients enrolled in this study. Three patients failed to RTW, and three others resigned within 6 months after surgery. The preoperative NRS and ODI were 7.2±1.2 and 22.1±7.9, respectively. The average time to RTW was 5.1±6.0 weeks. At RTW, NRS was 1.5±1.8 and ODI was 6.3±3.9. Amongst patients that successfully returned to work were 16 self-employed workers, 42 regular employees, and three contracted workers. The time to RTW of self-employed, regular, and contracted workers were 5.9±8.8, 4.2±4.3 and 13.3±2.3 weeks, respectively (p=0.011). Thirty-six of the patients that returned to work self-reported a 22.8±15.6% reduction in work capability at 6 months. Conclusion : RTW may vary depending on the employment status. In this study, we found that while employment type may affect the length to RTW, most patients were able to RTW and >40% of patients reported no loss of work capabilities 6 months postoperatively, hopefully alleviating some patient hesitation towards LD.
- Open Access
- 1 July 2019
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 62 (4) , 389-397
The Effects of Balloon-Guide Catheters on Outcomes after Mechanical Thrombectomy in Acute Ischemic Strokes : A Meta-Analysis
Mechanical thrombectomies with balloon-guide catheters (BGC) are thought to improve successful recanalization rates and to decrease the incidence of distal emboli compared to thrombectomies without BGC. We aimed to assess the effects of BGC on the outcomes of mechanical thrombectomy in acute ischemic strokes. Studies from PubMed, EMBASE, and the Cochrane library database from January 2010 to February 2018 were reviewed. Random effect model for meta-analysis was used. Analyses such as meta-regression and the "trim-and-fill" method were additionally carried out. A total of seven articles involving 2223 patients were analyzed. Mechanical thrombectomy with BGC was associated with higher rates of successful recanalization (odds ratio [OR], 1.632; 95% confidence interval [CI], 1.293-2.059). BGC did not significantly decrease distal emboli, both before (OR, 0.404; 95% CI, 0.108-1.505) and after correcting for bias (adjusted OR, 1.165; 95% CI, 0.310- 4.382). Good outcomes were observed more frequently in the BGC group (OR, 1.886; 95% CI, 1.564-2.273). Symptomatic intracranial hemorrhage and mortality did not differ significantly with BGC use. Our meta-analysis demonstrates that BGC enhance recanalization rates. However, BGC use did not decrease distal emboli after mechanical thrombectomies. This should be interpreted with caution due to possible publication bias and heterogeneity. Additional meta-analyses based on individual patient data are needed to clarify the role of BGC in mechanical thrombectomies.
- 1 July 2019
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 62 (4) , 389-397
Open AccessThe Effects of Balloon-Guide Catheters on Outcomes after Mechanical Thrombectomy in Acute Ischemic Strokes : A Meta-Analysis
Mechanical thrombectomies with balloon-guide catheters (BGC) are thought to improve successful recanalization rates and to decrease the incidence of distal emboli compared to thrombectomies without BGC. We aimed to assess the effects of BGC on the outcomes of mechanical thrombectomy in acute ischemic strokes. Studies from PubMed, EMBASE, and the Cochrane library database from January 2010 to February 2018 were reviewed. Random effect model for meta-analysis was used. Analyses such as meta-regression and the "trim-and-fill" method were additionally carried out. A total of seven articles involving 2223 patients were analyzed. Mechanical thrombectomy with BGC was associated with higher rates of successful recanalization (odds ratio [OR], 1.632; 95% confidence interval [CI], 1.293-2.059). BGC did not significantly decrease distal emboli, both before (OR, 0.404; 95% CI, 0.108-1.505) and after correcting for bias (adjusted OR, 1.165; 95% CI, 0.310- 4.382). Good outcomes were observed more frequently in the BGC group (OR, 1.886; 95% CI, 1.564-2.273). Symptomatic intracranial hemorrhage and mortality did not differ significantly with BGC use. Our meta-analysis demonstrates that BGC enhance recanalization rates. However, BGC use did not decrease distal emboli after mechanical thrombectomies. This should be interpreted with caution due to possible publication bias and heterogeneity. Additional meta-analyses based on individual patient data are needed to clarify the role of BGC in mechanical thrombectomies.
- Open Access
- 25 February 2019
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 8 (2) , 275
Genomic Variations in Susceptibility to Intracranial Aneurysm in the Korean Population
Genome-wide association studies found genetic variations with modulatory effects for intracranial aneurysm (IA) formations in European and Japanese populations. We aimed to identify the susceptibility of single nucleotide polymorphisms (SNPs) to IA in a Korean population consisting of 250 patients, and 294 controls using the Asian-specific Axiom Precision Medicine Research Array. Twenty-nine SNPs reached a genome-wide significance threshold (5 × 10−8). The rs371331393 SNP, with a stop-gain function of ARHGAP32 (11q24.3), showed the most significant association with the risk of IA (OR = 43.57, 95% CI: 21.84–86.95; p = 9.3 × 10−27). Eight out of 29 SNPs—GBA (rs75822236), TCF24 (rs112859779), OLFML2A (rs79134766), ARHGAP32 (rs371331393), CD163L1 (rs138525217), CUL4A (rs74115822), LOC102724084 (rs75861150), and LRRC3 (rs116969723)—demonstrated sufficient statistical power greater than or equal to 0.8. Two previously reported SNPs, rs700651 (BOLL, 2q33.1) and rs6841581 (EDNRA, 4q31.22), were validated in our GWAS (Genome-wide association study). In a subsequent analysis, three SNPs showed a significant difference in expressions: the rs6741819 (RNF144A, 2p25.1) was down-regulated in the adrenal gland tissue (p = 1.5 × 10−6), the rs1052270 (TMOD1. 9q22.33) was up-regulated in the testis tissue (p = 8.6 × 10−10), and rs6841581 (EDNRA, 4q31.22) was up-regulated in both the esophagus (p = 5.2 × 10−12) and skin tissues (1.2 × 10−6). Our GWAS showed novel candidate genes with Korean-specific variations in IA formations. Large population based studies are thus warranted.
- 25 February 2019
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 8 (2) , 275
Open AccessGenomic Variations in Susceptibility to Intracranial Aneurysm in the Korean Population
Genome-wide association studies found genetic variations with modulatory effects for intracranial aneurysm (IA) formations in European and Japanese populations. We aimed to identify the susceptibility of single nucleotide polymorphisms (SNPs) to IA in a Korean population consisting of 250 patients, and 294 controls using the Asian-specific Axiom Precision Medicine Research Array. Twenty-nine SNPs reached a genome-wide significance threshold (5 × 10−8). The rs371331393 SNP, with a stop-gain function of ARHGAP32 (11q24.3), showed the most significant association with the risk of IA (OR = 43.57, 95% CI: 21.84–86.95; p = 9.3 × 10−27). Eight out of 29 SNPs—GBA (rs75822236), TCF24 (rs112859779), OLFML2A (rs79134766), ARHGAP32 (rs371331393), CD163L1 (rs138525217), CUL4A (rs74115822), LOC102724084 (rs75861150), and LRRC3 (rs116969723)—demonstrated sufficient statistical power greater than or equal to 0.8. Two previously reported SNPs, rs700651 (BOLL, 2q33.1) and rs6841581 (EDNRA, 4q31.22), were validated in our GWAS (Genome-wide association study). In a subsequent analysis, three SNPs showed a significant difference in expressions: the rs6741819 (RNF144A, 2p25.1) was down-regulated in the adrenal gland tissue (p = 1.5 × 10−6), the rs1052270 (TMOD1. 9q22.33) was up-regulated in the testis tissue (p = 8.6 × 10−10), and rs6841581 (EDNRA, 4q31.22) was up-regulated in both the esophagus (p = 5.2 × 10−12) and skin tissues (1.2 × 10−6). Our GWAS showed novel candidate genes with Korean-specific variations in IA formations. Large population based studies are thus warranted.
- 1 October 2017
- Published by Elsevier in World Neurosurgery
- Vol. 106, 120-130
Intraoperative Near-Infrared Optical Contrast Can Localize Brain Metastases
- 1 October 2017
- Published by Elsevier in World Neurosurgery
- Vol. 106, 120-130
Intraoperative Near-Infrared Optical Contrast Can Localize Brain Metastases