BMBrendan B. Murphy

Brendan B. Murphy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Brendan B. Murphy has a total of 63 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A comparative assessment of the simple and modified Randles cells using machine learning for optimal impedance fitting on artificial skin

    by Brendan B. Murphy, Takeshi Torita

    Wearable devices in the healthcare space rely on electrodes interfacing with the skin to capture biosignals such as the electroencephalogram (EEG), electromyogram (EMG), and electrocardiogram (ECG), and a low electrode–skin impedance is essential for high-fidelity recording. Equivalent circuit models (ECMs) are widely used to interpret impedance data, but choosing models that balance accuracy with interpretability remains challenging. In this study, impedance spectra from seven types of commercial gelled and dry electrodes interfacing with artificial skin were fitted using two ECMs: the common Randles cell and a modified Randles cell featuring a Warburg impedance element. Both ECMs fit the impedance data well, but logistic regression (LR) using the ECM parameters revealed key differences. While either model could be used to classify electrodes as gelled or dry with > 70% accuracy, only the modified Randles cell supported multiclass differentiation among the seven electrode types with > 80% accuracy. These findings demonstrate that a Warburg-modified Randles cell results in more informative fitting results during wearable sensor characterization. More broadly, this report establishes a generalizable workflow integrating impedance fitting with supervised machine learning (ML) to optimize ECM selection, which we strongly recommend to researchers in the wearable devices field.


  • Stability of Ti3C2Tx MXene Films and Devices under Clinical Sterilization Processes

    by Spencer R. Averbeck, Doris Xu, Brendan B. Murphy, Kateryna Shevchuk, Sneha Shankar, Mark Anayee, Marcelo Der Torossian Torres, Michael S. Beauchamp, Cesar de la Fuente-Nunez, Yury Gogotsi, et al.

    MXenes are being heavily investigated in biomedical research, with applications ranging from regenerative medicine to bioelectronics. To enable the adoption and integration of MXenes into therapeutic platforms and devices, however, their stability under standard sterilization procedures must be established. Here, we present a comprehensive investigation of the electrical, chemical, structural, and mechanical effects of common thermal (autoclave) and chemical (ethylene oxide (EtO) and H2O2 gas plasma) sterilization protocols on both thin-film Ti3C2Tx MXene microelectrodes and mesoscale arrays made from Ti3C2Tx-infused cellulose–elastomer composites. We also evaluate the effectiveness of the sterilization processes in eliminating all pathogens from the Ti3C2Tx films and composites. Post-sterilization analysis revealed that autoclave and EtO did not alter the DC conductivity, electrochemical impedance, surface morphology, or crystallographic structure of Ti3C2Tx and were both effective at eliminating E. coli from both types of Ti3C2Tx-based devices. On the other end, exposure to H2O2 gas plasma sterilization for 45 min induced severe degradation of the structure and properties of Ti3C2Tx films and composites. The stability of the Ti3C2Tx after EtO and autoclave sterilization and the complete removal of pathogens establish the viability of both sterilization processes for Ti3C2Tx-based technologies.


  • Top Cited Papers

    MXene-infused bioelectronic interfaces for multiscale electrophysiology and stimulation

    by Nicolette Driscoll, Brian Erickson, Brendan B. Murphy, Andrew G. Richardson, Gregory Robbins, Nicholas V. Apollo, Georgios Mentzelopoulos, Tyler Mathis, Kanit Hantanasirisakul, Puneet Bagga, et al.

    Ti 3 C 2 MXene–based bioelectronics produced through a highly scalable process enable multiscale electrophysiology and stimulation.


  • Open Access

    Time Evolution of the Skin–Electrode Interface Impedance under Different Skin Treatments

    by Brendan B. Murphy, Brittany H. Scheid, Quincy Hendricks, Nicholas V. Apollo, Brian Litt, Flavia Vitale

    A low and stable impedance at the skin–electrode interface is key to high-fidelity acquisition of biosignals, both acutely and in the long term. However, recording quality is highly variable due to the complex nature of human skin. Here, we present an experimental and modeling framework to investigate the interfacial impedance behavior, and describe how skin interventions affect its stability over time. To illustrate this approach, we report experimental measurements on the skin–electrode impedance using pre-gelled, clinical-grade electrodes in healthy human subjects recorded over 24 h following four skin treatments: (i) mechanical abrasion, (ii) chemical exfoliation, (iii) microporation, and (iv) no treatment. In the immediate post-treatment period, mechanical abrasion yields the lowest initial impedance, whereas the other treatments provide modest improvement compared to untreated skin. After 24 h, however, the impedance becomes more uniform across all groups (<20 kΩ at 10 Hz). The impedance data are fitted with an equivalent circuit model of the complete skin–electrode interface, clearly identifying skin-level versus electrode-level contributions to the overall impedance. Using this model, we systematically investigate how time and treatment affect the impedance response, and show that removal of the superficial epidermal layers is essential to achieving a low, long-term stable interface impedance.


  • Open Access

    Multimodal in vivo recording using transparent graphene microelectrodes illuminates spatiotemporal seizure dynamics at the microscale

    by Nicolette Driscoll, Richard E. Rosch, Brendan B. Murphy, Arian Ashourvan, Ramya Vishnubhotla, Olivia O. Dickens, A. T. Charlie Johnson, Kathryn A. Davis, Brian Litt, Danielle S. Bassett, et al.

    Neurological disorders such as epilepsy arise from disrupted brain networks. Our capacity to treat these disorders is limited by our inability to map these networks at sufficient temporal and spatial scales to target interventions. Current best techniques either sample broad areas at low temporal resolution (e.g. calcium imaging) or record from discrete regions at high temporal resolution (e.g. electrophysiology). This limitation hampers our ability to understand and intervene in aberrations of network dynamics. Here we present a technique to map the onset and spatiotemporal spread of acute epileptic seizures in vivo by simultaneously recording high bandwidth microelectrocorticography and calcium fluorescence using transparent graphene microelectrode arrays. We integrate dynamic data features from both modalities using non-negative matrix factorization to identify sequential spatiotemporal patterns of seizure onset and evolution, revealing how the temporal progression of ictal electrophysiology is linked to the spatial evolution of the recruited seizure core. This integrated analysis of multimodal data reveals otherwise hidden state transitions in the spatial and temporal progression of acute seizures. The techniques demonstrated here may enable future targeted therapeutic interventions and novel spatially embedded models of local circuit dynamics during seizure onset and evolution.


  • Gels, jets, mosquitoes, and magnets: a review of implantation strategies for soft neural probes

    by Nicholas V Apollo, Brendan Murphy, Kayla Prezelski, Nicolette Driscoll, Andrew G Richardson, Timothy H Lucas, Flavia Vitale

    Implantable neuroelectronic interfaces have enabled breakthrough advances in the clinical diagnosis and treatment of neurological disorders, as well as in fundamental studies of brain function, behavior, and disease. Intracranial electroencephalography (EEG) mapping with stereo-EEG (sEEG) depth electrodes is routinely adopted for precise epilepsy diagnostics and surgical treatment, while deep brain stimulation has become the standard of care for managing movement disorders. Intracortical microelectrode arrays for high-fidelity recordings of neural spiking activity have led to impressive demonstrations of the power of brain-machine interfaces for motor and sensory functional recovery. Yet, despite the rapid pace of technology development, the issue of establishing a safe, long-term, stable, and functional interface between neuroelectronic devices and the host brain tissue still remains largely unresolved. A body of work spanning at least the last 15 years suggests that safe, chronic integration between invasive electrodes and the brain requires a close match between the mechanical properties of man-made components and the neural tissue. In other words, the next generation of invasive electrodes should be soft and compliant, without sacrificing biological and chemical stability. Soft neuroelectronic interfaces, however, pose a new and significant surgical challenge: bending and buckling during implantation that can preclude accurate and safe device placement. In this topical review, we describe the next generation of soft electrodes and the surgical implantation methods for safe and precise insertion into brain structures. We provide an overview of the most recent innovations in the field of insertion strategies for flexible neural electrodes such as dissolvable or biodegradable carriers, microactuators, biologically-inspired support structures, and electromagnetic drives. In our analysis, we also highlight approaches developed in different fields, such as robotic surgery, which could be potentially adapted and translated to the insertion of flexible neural probes.


  • A Gel‐Free Ti3C2Tx‐Based Electrode Array for High‐Density, High‐Resolution Surface Electromyography

    by Brendan B. Murphy, Patrick J. Mulcahey, Nicolette Driscoll, Andrew G. Richardson, Gregory T. Robbins, Nicholas V. Apollo, Kathleen Maleski, Timothy H. Lucas, Yury Gogotsi, Timothy Dillingham, et al.

    Wearable sensors for surface electromyography (EMG) are composed of single‐ to few‐channel large‐area contacts, which exhibit high interfacial impedance and require conductive gels or adhesives to record high‐fidelity signals. These devices are also limited in their ability to record activation across large muscle groups due to poor spatial coverage. To address these challenges, a novel high‐density EMG array is developed based on titanium carbide (Ti3C2Tx) MXene encapsulated in parylene‐C. Ti3C2Tx is a 2D nanomaterial with excellent electrical, electrochemical, and mechanical properties, which forms colloidally stable aqueous dispersions, enabling safe, scalable solutions‐processing. Leveraging the excellent combination of metallic conductivity, high pseudocapacitance, and ease of processability of Ti3C2Tx MXene, the fabrication of gel‐free, high‐density EMG arrays is demonstrated, which are ≈8 µm thick, feature 16 recording channels, and are highly skin conformable. The impedance of Ti3C2Tx electrodes in contact with human skin is 100–1000× lower than the impedance of commercially available electrodes which require conductive gels to be effective. Furthermore, the arrays can record high‐fidelity, low‐noise EMG, and can resolve muscle activation with improved spatiotemporal resolution and sensitivity compared to conventional gelled electrodes. Overall, the results establish Ti3C2Tx‐based bioelectronic interfaces as a powerful platform technology for high‐resolution, noninvasive wearable sensing technologies.


  • Open Access

    Multimodal in vivo recording using transparent graphene microelectrodes illuminates spatiotemporal seizure dynamics at the microscale

    by Nicolette Driscoll, Richard Rosch, Brendan B. Murphy, Arian Ashourvan, Ramya Vishnubhotla, Olivia O. Dickens, A.T. Charlie Johnson, Kathryn A. Davis, Brian Litt, Danielle S. Bassett, et al.

    Neurological disorders such as epilepsy arise from disrupted brain networks. Our capacity to treat these disorders is limited by our inability to map these networks at sufficient temporal and spatial scales to target interventions. Current best techniques either sample broad areas at low temporal resolution (e.g. calcium imaging) or record from discrete regions at high temporal resolution (e.g. electrophysiology). This limitation hampers our ability to understand and intervene in aberrations of network dynamics. Here we present a technique to map the onset and spatiotemporal spread of acute epileptic seizures in vivo by simultaneously recording high bandwidth microelectrocorticography and calcium fluorescence using transparent graphene microelectrode arrays. We integrate dynamic data features from both modalities using non-negative matrix factorization to identify sequential spatiotemporal patterns of seizure onset and evolution, revealing how the temporal progression of ictal electrophysiology is linked to the spatial evolution of the recruited seizure core. This integrated analysis of multimodal data reveals otherwise hidden state transitions in the spatial and temporal progression of acute seizures. The techniques demonstrated here may enable future targeted therapeutic interventions and novel spatially embedded models of local circuit dynamics during seizure onset and evolution.


  • Open Access

    Biomimetic extracellular matrix coatings improve the chronic biocompatibility of microfabricated subdural microelectrode arrays

    by Flavia Vitale, Wendy Shen, Nicolette Driscoll, Justin C Burrell, Andrew G Richardson, Oladayo Adewole, Brendan Murphy, Akshay Ananthakrishnan, Hanju Oh, Theodore Wang, et al.

    Intracranial electrodes are a vital component of implantable neurodevices, both for acute diagnostics and chronic treatment with open and closed-loop neuromodulation. Their performance is hampered by acute implantation trauma and chronic inflammation in response to implanted materials and mechanical mismatch between stiff synthetic electrodes and pulsating, natural soft host neural tissue. Flexible electronics based on thin polymer films patterned with microscale conductive features can help alleviate the mechanically induced trauma; however, this strategy alone does not mitigate inflammation at the device-tissue interface. In this study, we propose a biomimetic approach that integrates microscale extracellular matrix (ECM) coatings on microfabricated flexible subdural microelectrodes. Taking advantage of a high-throughput process employing micro-transfer molding and excimer laser micromachining, we fabricate multi-channel subdural microelectrodes primarily composed of ECM protein material and demonstrate that the electrochemical and mechanical properties match those of standard, uncoated controls. In vivo ECoG recordings in rodent brain confirm that the ECM microelectrode coatings and the protein interface do not alter signal fidelity. Astrogliotic, foreign body reaction to ECM coated devices is reduced, compared to uncoated controls, at 7 and 30 days, after subdural implantation in rat somatosensory cortex. We propose microfabricated, flexible, biomimetic electrodes as a new strategy to reduce inflammation at the device-tissue interface and improve the long-term stability of implantable subdural electrodes.