STSindri Traustason

Sindri Traustason

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sindri Traustason has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Spectrophotometric Retinal Oximetry in Pigs

    by Sindri Traustason, Jens F. Kiilgaard, Robert A. Karlsson, Sveinn H. Hardarson, Einar Stefansson, Morten la Cour

    Purpose. To assess the validity of spectrophotometric retinal oximetry by comparison to blood gas analysis and intravitreal measurements of partial pressure of oxygen (pO2). Methods. Female domestic pigs were used for all experiments (n = 8). Oxygen fraction in inspired air was changed using a mixture of room air, pure oxygen, and pure nitrogen, ranging from 5% to 100% oxygen. Femoral arterial blood gas analysis and retinal oximetry were performed at each level of inspiratory oxygen fraction. Retinal oximetry was performed using a commercial instrument, the Oxymap Retinal Oximeter T1. The device simultaneously acquires images at two wavelengths (570 nm and 600 nm), and specialized software automatically detects retinal blood vessels. In three pigs, invasive pO2 measurements were performed after the initial noninvasive measurements. Results. Comparison of femoral arterial oxygen saturation and the optical density ratio over retinal arteries revealed an approximately linear relationship (R2 = 0.74, P = 3.4 × 10−9). In order to test the validity of applying the arterial calibration to veins, we compared noninvasive oximetry measurements to invasive pO2 measurements in three pigs. This relationship was approximately linear (R2 = 0.45, P = 0.04). Conclusions. Noninvasive spectrophotometric oximetry is sensitive to changes in oxygen saturation in pigs and correlated with intravitreal pO2 measurements and with femoral artery pO2. Pigs present a higher intraindividual variability in retinal oxygen saturation and a lower overall saturation than do humans. The difference between porcine and human eyes makes direct comparisons of measurements difficult.


  • Open Access

    Acute macular neuroretinopathy in relation to anti‐thymocyte globulin infusion

    by Inger C. Munch, Sindri Traustason, Klaus Olgaard, Michael Larsen


  • Retinal Oxygen Saturation in Patients with Systemic Hypoxemia

    by Sindri Traustason, Annette Schophuus Jensen, Henrik Sven Arvidsson, Inger Christine Munch, Lars Søndergaard, Michael Larsen

    Purpose.: To assess spectrophotometric oximetry across a broad range of arterial saturation levels and to study the effect of chronic systemic hypoxemia on retinal oxygen extraction. Methods.: The study included 16 patients with Eisenmenger syndrome, a cyanotic cardiac defect, and 17 healthy volunteers. Oxygen saturation in selected major retinal arteries and veins was assessed using noninvasive spectrophotometric oximetry. Arterial blood gases were determined within 1 day of the ophthalmic examination in blood samples from the femoral artery. Results.: The retinal arterial oxygen saturation of 81% ± 9% (mean ± SD) in patients with Eisenmenger syndrome was subnormal and demonstrated more interindividual variation than the 93% ± 3% observed in healthy subjects (P < 0.001). A comparable difference was found for the respective retinal venous oxygen saturations of 44% ± 12% and 59% ± 5% (P < 0.001). Fractional arteriovenous oxygen extraction was comparable between the two groups (37% ± 6% and 34% ± 5%, respectively; P = 0.29). Retinal and femoral artery oxygen saturation were correlated (ρ = 0.82; P < 0.001), the former approximating the latter at least as well as fingertip oximetry. Conclusions.: When compared to arterial blood gas analysis of blood samples drawn by arterial puncture, the gold standard in the field, fundus oximetry was found to be in good overall agreement with the arterial blood samples. Blood flow measurements will be needed to determine whether the systemic hypoxia is completely compensated, as suggested by oxygen extraction being comparable between the two groups.


  • Dorzolamide-timolol combination and retinal vessel oxygen saturation in patients with glaucoma or ocular hypertension

    by S Traustason, S H Hardarson, M S Gottfredsdottir, T Eysteinsson, R A Karlsson, E Stefansson, A Harris

    Aims: To examine whether the addition of dorzolamide to timolol monotherapy influences oxygen saturation in the human retina. Methods: Non-invasive spectrophotometric retinal oximetry was used to measure oxygen saturation in retinal vessels. Twenty patients with open-angle glaucoma (11) and ocular hypertension (9) were recruited. The patients were randomised into receiving timolol monotherapy or dorzolamide–timolol combination for an 8-month test period, followed by a second test period, before which the patients switched treatments. Oximetry measurements were performed at 2-month intervals during each period. Of the 20 patients, 13 followed the study protocol into the second test period, and 10 managed all study visits. Results: The oxygen saturation in retinal vessels was stable within the test periods. The mean arteriolar saturation was 96 (2)% (mean (SD)) during timolol monotherapy and 97 (2)% during dorzolamide–timolol combination therapy (p = 0.17, all patients pooled, n = 13). Corresponding values in venules were 66 (5)% during timolol monotherapy and 65 (6)% during dorzolamide–timolol therapy (p = 0.13). Patients who started on dorzolamide–timolol combination showed a significant reduction in arteriolar (98 (2)% to 95 (2)%, pConclusion: Adding dorzolamide to timolol monotherapy has a minimal effect, but going from dorzolamide–timolol combination to timolol alone lowered arteriolar and venular oxygen saturation. The retinal oxygen saturation measurements show a high degree of stability over an extended period of time. Previous studies have suggested increased retinal and optic nerve blood flow with dorzolamide. Unchanged oxygen saturation and increased blood flow would indicate increased oxygen delivery to the retina.


  • GABA agonists fail to protect the retina from ischemia–reperfusion injury

    by Sindri Traustason, Thor Eysteinsson, Bjarni A. Agnarsson, Einar Stefánsson