Nese Orbey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nese Orbey has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Ezgi Melis Dogan
Chemical Engineering Department and ‡Chemistry Department, University of Massachusetts Lowell, 1 University Avenue, Lowell, Massachusetts 01854 United States
2 shared publicationsFulya Sudur
Chemical Engineering Department, University of Massachusetts Lowell, 1 University Avenue, Lowell, Massachusetts 01854, United States
2 shared publicationsFulya Sudur Zalluhoglu
Chemical Engineering Department and ‡Chemistry Department, University of Massachusetts Lowell, 1 University Avenue, Lowell, Massachusetts 01854 United States
2 shared publications- Ravi Mosurkal
US Army Natick Soldier Research, Development and Engineering Center, Natick, MA 01760, USA
2 shared publications Azadeh Farahanchi
Plastics Engineering University of Massachusetts Lowell 1 University Avenue Lowell Massachusetts 01854
1 shared publicationBrian Pleskowicz
Chemical Engineering Department, University of Massachusetts Lowell, 1 University Avenue, Lowell, Massachusetts 01854, United States
1 shared publication
Latest Publications
- 17 December 2025
- Published by Elsevier in Colloids and Surfaces A: Physicochemical and Engineering Aspects
- Vol. 733
Microencapsulation of geraniol using UV curable GeLMA/gum arabic coacervates
- 17 December 2025
- Published by Elsevier in Colloids and Surfaces A: Physicochemical and Engineering Aspects
- Vol. 733
Microencapsulation of geraniol using UV curable GeLMA/gum arabic coacervates
- Open Access
- 24 March 2025
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 64 (16) , 8202-8210
Investigation of the Synergistic Effect of Combined Antimicrobial Agents and Insect Repellent Microcapsules on Fabrics
- 24 March 2025
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 64 (16) , 8202-8210
Open AccessInvestigation of the Synergistic Effect of Combined Antimicrobial Agents and Insect Repellent Microcapsules on Fabrics
- 7 August 2024
- Published by American Chemical Society (ACS) in ACS Applied Polymer Materials
- Vol. 6 (16) , 9430-9439
Comparison of High-Throughput and Conventional Tensile Testing for 3D-Printed Polymers
- 7 August 2024
- Published by American Chemical Society (ACS) in ACS Applied Polymer Materials
- Vol. 6 (16) , 9430-9439
Comparison of High-Throughput and Conventional Tensile Testing for 3D-Printed Polymers
- 21 February 2019
- Published by Springer Nature in Biomedical Microdevices
- Vol. 21 (1) , 21
Numerical evaluation and experimental validation of cross-flow microfiltration device design
This research presents a comprehensive analysis of the design and validation of a cross-flow microfiltration device for separation of microspheres based on size. Simulation results showed that pillar size, pillar shape, incorporation of back-flow preventers, and rounding of pillar layouts affected flow patterns in a cross-flow microfiltration device. Simulation results suggest that larger pillar sizes reduce filtration capacity by decreasing the density of microfiltration gaps in the device. Therefore, 10 μm rather than 20 μm diameter pillars were incorporated in the device. Fluid flow was not greatly affected when comparing circular, octagonal, and hexagonal pillars. However, side-channel fluid velocities decreased when using triangular and square pillars. The lengths of back-flow prevention walls were optimized to completely prevent back flow without inhibiting filtration ability. A trade-off was observed in the designs of the pillar layouts; while rounding the pillars layout in the channels bends eliminated stagnation areas, the design also decreased side-channel fluid velocity compared to the right-angle layout. Experimental separation efficiency was tested using polydimethylsiloxane (PDMS) and silicon microfluidic devices with microspheres simulating white and red blood cells. Efficiencies for separation of small microspheres to the side channels ranged from 73 to 75%. The silicon devices retained the large microspheres in the main channel with efficiencies between 95 and 100%, but these efficiencies were lower with PDMS devices and were affected by sphere concentration. Additionally, PDMS devices resulted in greater agglomeration of spheres when compared to silicon devices. PDMS devices, however, were easier and less expensive to fabricate.
- 21 February 2019
- Published by Springer Nature in Biomedical Microdevices
- Vol. 21 (1) , 21
Numerical evaluation and experimental validation of cross-flow microfiltration device design
This research presents a comprehensive analysis of the design and validation of a cross-flow microfiltration device for separation of microspheres based on size. Simulation results showed that pillar size, pillar shape, incorporation of back-flow preventers, and rounding of pillar layouts affected flow patterns in a cross-flow microfiltration device. Simulation results suggest that larger pillar sizes reduce filtration capacity by decreasing the density of microfiltration gaps in the device. Therefore, 10 μm rather than 20 μm diameter pillars were incorporated in the device. Fluid flow was not greatly affected when comparing circular, octagonal, and hexagonal pillars. However, side-channel fluid velocities decreased when using triangular and square pillars. The lengths of back-flow prevention walls were optimized to completely prevent back flow without inhibiting filtration ability. A trade-off was observed in the designs of the pillar layouts; while rounding the pillars layout in the channels bends eliminated stagnation areas, the design also decreased side-channel fluid velocity compared to the right-angle layout. Experimental separation efficiency was tested using polydimethylsiloxane (PDMS) and silicon microfluidic devices with microspheres simulating white and red blood cells. Efficiencies for separation of small microspheres to the side channels ranged from 73 to 75%. The silicon devices retained the large microspheres in the main channel with efficiencies between 95 and 100%, but these efficiencies were lower with PDMS devices and were affected by sphere concentration. Additionally, PDMS devices resulted in greater agglomeration of spheres when compared to silicon devices. PDMS devices, however, were easier and less expensive to fabricate.
- 16 December 2018
- Published by Oxford University Press (OUP) in Journal of Applied Microbiology
- Vol. 126 (3) , 965-972
Stabilization and Controlled Release of Microencasulated Hydrogen Peroxide for Wound Treatment Applications
Aims Hydrogen peroxide (H2O2) disinfection applications are limited by its rapid inactivation. The aims of this study were to 1) microencapsulate H2O2 in silica hydrogels to obtain controlled release up to 72 hours, 2) test hydrogel antimicrobial activity against four common pathogens, and 3) assess H2O2 release kinetics and antimicrobial activity in 35 – 65% relative humidity and 37°C to approximate bandaged wound conditions. Methods and Results Hydrogels were characterized using scanning electron microscopy, nitrogen sorption porosimetry, Brunauer Emmet Teller analysis, and the Barret – Joyner – Halenda method. Hydrogels formed at lower pH demonstrated increased surface area and decreased pore size, resulting in H2O2 release lasting 72 hours. Using agar well diffusion for antimicrobial activity, statistically significant zones of inhibition (as compared to controls) were seen for Escherichia coli, Staphylococcus aureus, Pseudomona aeruginiosa, and Vancomycin‐resistant Enterococcus faecalis. Activity remained for hydrogels aged for 72 hours in humid, 37°C conditions. Conclusions Hydrogels can be synthesized to provide a continuous, controlled release of H2O2 for up to 72 hours. Significance and Impact of the Study Stable, controlled‐release H2O2 hydrogels have potential applications for wound treatment and disinfection of medical equipment, through bonding to bandages or materials such as catheter lumens.
- 16 December 2018
- Published by Oxford University Press (OUP) in Journal of Applied Microbiology
- Vol. 126 (3) , 965-972
Stabilization and Controlled Release of Microencasulated Hydrogen Peroxide for Wound Treatment Applications
Aims Hydrogen peroxide (H2O2) disinfection applications are limited by its rapid inactivation. The aims of this study were to 1) microencapsulate H2O2 in silica hydrogels to obtain controlled release up to 72 hours, 2) test hydrogel antimicrobial activity against four common pathogens, and 3) assess H2O2 release kinetics and antimicrobial activity in 35 – 65% relative humidity and 37°C to approximate bandaged wound conditions. Methods and Results Hydrogels were characterized using scanning electron microscopy, nitrogen sorption porosimetry, Brunauer Emmet Teller analysis, and the Barret – Joyner – Halenda method. Hydrogels formed at lower pH demonstrated increased surface area and decreased pore size, resulting in H2O2 release lasting 72 hours. Using agar well diffusion for antimicrobial activity, statistically significant zones of inhibition (as compared to controls) were seen for Escherichia coli, Staphylococcus aureus, Pseudomona aeruginiosa, and Vancomycin‐resistant Enterococcus faecalis. Activity remained for hydrogels aged for 72 hours in humid, 37°C conditions. Conclusions Hydrogels can be synthesized to provide a continuous, controlled release of H2O2 for up to 72 hours. Significance and Impact of the Study Stable, controlled‐release H2O2 hydrogels have potential applications for wound treatment and disinfection of medical equipment, through bonding to bandages or materials such as catheter lumens.
- 27 February 2017
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 56 (9) , 2607-2614
In Situ Encapsulation of Hydrogen Peroxide in a Silica Matrix in the Presence of Divalent Metal Ions (Mg2+ and Ca2+)
- 27 February 2017
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 56 (9) , 2607-2614
In Situ Encapsulation of Hydrogen Peroxide in a Silica Matrix in the Presence of Divalent Metal Ions (Mg2+ and Ca2+)
- 1 November 2016
- Published by Society of Rheology in Journal of Rheology
- Vol. 60 (6) , 1115-1120
On the use of continuous relaxation spectra to characterize model polymers
There have been many more papers published on methods for inferring a continuous relaxation spectrum from linear viscoelastic data than have been published on the use of such methods for polymer characterization. But a continuous spectrum can reveal key details of the relaxation process that are not evident from plots of the storage and loss moduli, particularly in the case of model polymers prepared for research. In particular there are sharp peaks in the spectrum where Rouse relaxation is complete and further relaxation is inhibited by entanglements in the plateau zone and at the entry to the terminal zone where molecules have escaped their tubes. Examples of continuous spectra that reveal these relaxation phenomena are presented.
- 1 November 2016
- Published by Society of Rheology in Journal of Rheology
- Vol. 60 (6) , 1115-1120
On the use of continuous relaxation spectra to characterize model polymers
There have been many more papers published on methods for inferring a continuous relaxation spectrum from linear viscoelastic data than have been published on the use of such methods for polymer characterization. But a continuous spectrum can reveal key details of the relaxation process that are not evident from plots of the storage and loss moduli, particularly in the case of model polymers prepared for research. In particular there are sharp peaks in the spectrum where Rouse relaxation is complete and further relaxation is inhibited by entanglements in the plateau zone and at the entry to the terminal zone where molecules have escaped their tubes. Examples of continuous spectra that reveal these relaxation phenomena are presented.
- 7 July 2016
- Published by Wiley in Polymer Engineering & Science
- Vol. 57 (1) , 60-68
The Effect of ultra‐high speed twin screw extrusion on ABS/organoclay nanocomposite blend properties
Acrylonitrile butadiene styrene (ABS) nanocomposites containing Cloisite 11 organoclay at 2 wt% were prepared using a 60 L/D ultra‐ high speed twin screw extruder (TSE), with speeds ranging from 400 to 4000 rpm. The purpose of this study was to investigate the effect of high shear melt processing on the intercalation and exfoliation of organoclay in the polymer, as well as the mechanical and rheological properties of the material. X‐ray Diffraction (XRD), and Transmission Electron Microscopy (TEM) results showed better intercalation of the nanofiller with increasing screw speed up to a point, and indicated an exfoliated structure of the nanocomposites extruded at 4000 rpm. Mechanical and rheological testing results indicated that by adding organoclay to ABS, the properties improved with increasing screw speed up to an optimum value of 2000 rpm. However, at the higher screw speeds of 3000 and 4000 rpm, the intense shear history led to a decrease in properties, most likely due to chain scission and molecular weight reduction. Similar trends were observed in rheological properties of the nanocomposite as well. At 2000 rpm, the results indicate that the lowering of the molecular weight due to shear effects is balanced by good intercalation/exfoliation of the organoclay. POLYM. ENG. SCI., 57:60–68, 2017. © 2016 Society of Plastics Engineers
- 7 July 2016
- Published by Wiley in Polymer Engineering & Science
- Vol. 57 (1) , 60-68
The Effect of ultra‐high speed twin screw extrusion on ABS/organoclay nanocomposite blend properties
Acrylonitrile butadiene styrene (ABS) nanocomposites containing Cloisite 11 organoclay at 2 wt% were prepared using a 60 L/D ultra‐ high speed twin screw extruder (TSE), with speeds ranging from 400 to 4000 rpm. The purpose of this study was to investigate the effect of high shear melt processing on the intercalation and exfoliation of organoclay in the polymer, as well as the mechanical and rheological properties of the material. X‐ray Diffraction (XRD), and Transmission Electron Microscopy (TEM) results showed better intercalation of the nanofiller with increasing screw speed up to a point, and indicated an exfoliated structure of the nanocomposites extruded at 4000 rpm. Mechanical and rheological testing results indicated that by adding organoclay to ABS, the properties improved with increasing screw speed up to an optimum value of 2000 rpm. However, at the higher screw speeds of 3000 and 4000 rpm, the intense shear history led to a decrease in properties, most likely due to chain scission and molecular weight reduction. Similar trends were observed in rheological properties of the nanocomposite as well. At 2000 rpm, the results indicate that the lowering of the molecular weight due to shear effects is balanced by good intercalation/exfoliation of the organoclay. POLYM. ENG. SCI., 57:60–68, 2017. © 2016 Society of Plastics Engineers
- 4 July 2016
- Published by Wiley in AIChE Journal
- Vol. 63 (2) , 409-417
Effect of potassium ion on the stability and release rate of hydrogen peroxide encapsulated in silica hydrogels
Hydrogen peroxide (H2O2) is encapsulated in silica hydrogels using sol‐gel method and the effects of the K+ : Na+ ion ratio on gelation time, hydrogel structure, stability, and release rate of H2O2 were investigated. As the amount of K+ ions increased relative to the amount of Na+ ions at the same pH, the gel structure became less compact and the pore diameter increased. Hydrogen peroxide retention values up to 90 and 80% were observed at the end of 7 and 20 days, respectively, in the presence of K+ ions at low pH values when the initial H2O2 concentration was 19.9 wt %. Release rate of hydrogen peroxide decreased with decreasing pH for the two K+ : Na+ ion ratios studied. This work presents an environmentally friendly, low cost, and easy to scale up method to increase the stability of high initial concentrations of H2O2 at room temperature and customize the release rate. © 2016 American Institute of Chemical Engineers AIChE J, 63: 409–417, 2017
- 4 July 2016
- Published by Wiley in AIChE Journal
- Vol. 63 (2) , 409-417
Effect of potassium ion on the stability and release rate of hydrogen peroxide encapsulated in silica hydrogels
Hydrogen peroxide (H2O2) is encapsulated in silica hydrogels using sol‐gel method and the effects of the K+ : Na+ ion ratio on gelation time, hydrogel structure, stability, and release rate of H2O2 were investigated. As the amount of K+ ions increased relative to the amount of Na+ ions at the same pH, the gel structure became less compact and the pore diameter increased. Hydrogen peroxide retention values up to 90 and 80% were observed at the end of 7 and 20 days, respectively, in the presence of K+ ions at low pH values when the initial H2O2 concentration was 19.9 wt %. Release rate of hydrogen peroxide decreased with decreasing pH for the two K+ : Na+ ion ratios studied. This work presents an environmentally friendly, low cost, and easy to scale up method to increase the stability of high initial concentrations of H2O2 at room temperature and customize the release rate. © 2016 American Institute of Chemical Engineers AIChE J, 63: 409–417, 2017
- 2 November 2015
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 54 (44) , 11251-11257
Properties of Hydrogen Peroxide Encapsulated in Silica Hydrogels and Xerogels
- 2 November 2015
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 54 (44) , 11251-11257
Properties of Hydrogen Peroxide Encapsulated in Silica Hydrogels and Xerogels