Young Jun Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Young Jun Kim has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
- Hee Sun Park
Department of Radiology, Konkuk University School of Medicine, Seoul, Korea
21 shared publications Hae Jeong Jeon
Department of Radiology, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, Korea
16 shared publicationsSung Il Jung
Department of Radiology, Konkuk University Medical Center, Konkuk University School of Medicine, 120-1 Neungdong-ro, Gwangjin-gu, Seoul 05030, South Korea
15 shared publications- Mi Hye Yu
Department of Radiology, Konkuk University Medical Center, Research Institute of Medical Science, Konkuk University School of Medicine, Seoul, Republic of Korea
8 shared publications - Sung Il Jung
Konkuk University Medical Center, Konkuk University School of Medicine
8 shared publications Sang Woo Park
Department of Radiology, Konkuk University, School of Medicine, South Korea
6 shared publications
Latest Publications
- 14 October 2024
- Published by Springer Nature in Abdominal Radiology
- p. 1-16
Multisystem diseases in the abdomen and pelvis: imaging manifestations and diagnostic roles of cross-sectional imaging
Systemic diseases, such as IgG4-related disease, sarcoidosis, and amyloidosis, usually involve multiple systems or organs simultaneously or sequentially. The gastrointestinal tract, hepatobiliary system, and genitourinary tract are commonly involved in many multisystem diseases and can also be the first sites with disease involvement. Cross-sectional imaging, such as CT and MR, plays an important role in the diagnosis and management of multisystem diseases by aiding in the evaluation of multiorgan involvement. Here, common imaging features of frequently affected organs are reviewed in multisystem diseases that we often encounter in the abdomen and pelvis, and the diagnostic roles of cross-sectional imaging for these diseases are also discussed.
- 14 October 2024
- Published by Springer Nature in Abdominal Radiology
- p. 1-16
Multisystem diseases in the abdomen and pelvis: imaging manifestations and diagnostic roles of cross-sectional imaging
Systemic diseases, such as IgG4-related disease, sarcoidosis, and amyloidosis, usually involve multiple systems or organs simultaneously or sequentially. The gastrointestinal tract, hepatobiliary system, and genitourinary tract are commonly involved in many multisystem diseases and can also be the first sites with disease involvement. Cross-sectional imaging, such as CT and MR, plays an important role in the diagnosis and management of multisystem diseases by aiding in the evaluation of multiorgan involvement. Here, common imaging features of frequently affected organs are reviewed in multisystem diseases that we often encounter in the abdomen and pelvis, and the diagnostic roles of cross-sectional imaging for these diseases are also discussed.
- Open Access
- 10 April 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (8) , 789
Discrepancies in Splenic Size Measurement: A Comparative Analysis of Ultrasound and Computed Tomography
The accurate measurement of splenic size is essential for the diagnosis and management of various gastrointestinal and hematological conditions. While ultrasound (US) and computed tomography (CT) are widely used imaging modalities for assessing splenic size, discrepancies between their measurements have been observed in clinical practice. This study aimed to analyze the measurement differences between US and CT and identify factors influencing these differences. A retrospective analysis of 598 asymptomatic patients who underwent both abdominal US and CT was conducted. Measurements of splenic size obtained from US, axial CT, and coronal CT scans were compared, and various factors such as patient demographics, operator experience, and imaging parameters were evaluated to elucidate their impact on the measurement discrepancies. The results revealed that US consistently underestimated splenic size compared to CT. The magnitude of the discrepancy was influenced by factors such as patient age, body mass index (BMI), depth of the spleen from skin on US and that on CT, visibility of the splenic hilum on US, sonic window quality, and operator experience. This study underscores the importance of considering these factors when interpreting splenic measurements obtained from different imaging modalities in clinical practice.
- 10 April 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (8) , 789
Open AccessDiscrepancies in Splenic Size Measurement: A Comparative Analysis of Ultrasound and Computed Tomography
The accurate measurement of splenic size is essential for the diagnosis and management of various gastrointestinal and hematological conditions. While ultrasound (US) and computed tomography (CT) are widely used imaging modalities for assessing splenic size, discrepancies between their measurements have been observed in clinical practice. This study aimed to analyze the measurement differences between US and CT and identify factors influencing these differences. A retrospective analysis of 598 asymptomatic patients who underwent both abdominal US and CT was conducted. Measurements of splenic size obtained from US, axial CT, and coronal CT scans were compared, and various factors such as patient demographics, operator experience, and imaging parameters were evaluated to elucidate their impact on the measurement discrepancies. The results revealed that US consistently underestimated splenic size compared to CT. The magnitude of the discrepancy was influenced by factors such as patient age, body mass index (BMI), depth of the spleen from skin on US and that on CT, visibility of the splenic hilum on US, sonic window quality, and operator experience. This study underscores the importance of considering these factors when interpreting splenic measurements obtained from different imaging modalities in clinical practice.
- Open Access
- 7 March 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (6) , 1008
Motion-Corrected versus Conventional Diffusion-Weighted Magnetic Resonance Imaging of the Liver Using Non-Rigid Registration
It is challenging to overcome motion artifacts in diffusion-weighted imaging (DWI) of the abdomen. This study aimed to evaluate the image quality of motion-corrected DWI of the liver using non-rigid registration in comparison with conventional DWI (c-DWI) in patients with liver diseases. Eighty-nine patients who underwent 3-T magnetic resonance imaging (MRI) of the liver were retrospectively included. DWI was performed using c-DWI and non-rigid motion-corrected (moco) DWI was performed in addition to c-DWI. The image quality and conspicuity of hepatic focal lesions were scored using a five-point scale by two radiologists and compared between the two DWI image sets. The apparent diffusion coefficient (ADC) was measured in three regions of the liver parenchyma and in hepatic focal lesions, and compared between the two DWI image sets. Moco-DWI achieved higher scores in image quality compared to c-DWI in terms of liver edge sharpness and hepatic vessel margin delineation. The conspicuity scores of hepatic focal lesions were higher in moco-DWI. The standard deviation values of ADC of the liver parenchyma were lower in the moco-DWI than in the c-DWI. Moco-DWI using non-rigid registration showed improved overall image quality and provided more reliable ADC measurement, with an equivalent scan time, compared with c-DWI.
- 7 March 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (6) , 1008
Open AccessMotion-Corrected versus Conventional Diffusion-Weighted Magnetic Resonance Imaging of the Liver Using Non-Rigid Registration
It is challenging to overcome motion artifacts in diffusion-weighted imaging (DWI) of the abdomen. This study aimed to evaluate the image quality of motion-corrected DWI of the liver using non-rigid registration in comparison with conventional DWI (c-DWI) in patients with liver diseases. Eighty-nine patients who underwent 3-T magnetic resonance imaging (MRI) of the liver were retrospectively included. DWI was performed using c-DWI and non-rigid motion-corrected (moco) DWI was performed in addition to c-DWI. The image quality and conspicuity of hepatic focal lesions were scored using a five-point scale by two radiologists and compared between the two DWI image sets. The apparent diffusion coefficient (ADC) was measured in three regions of the liver parenchyma and in hepatic focal lesions, and compared between the two DWI image sets. Moco-DWI achieved higher scores in image quality compared to c-DWI in terms of liver edge sharpness and hepatic vessel margin delineation. The conspicuity scores of hepatic focal lesions were higher in moco-DWI. The standard deviation values of ADC of the liver parenchyma were lower in the moco-DWI than in the c-DWI. Moco-DWI using non-rigid registration showed improved overall image quality and provided more reliable ADC measurement, with an equivalent scan time, compared with c-DWI.
- Open Access
- 28 January 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (3) , 480
Computed Tomography Indicators for Differentiating Stage 1 Borderline Ovarian Tumors from Stage I Malignant Epithelial Ovarian Tumors
Preoperative diagnosis of borderline ovarian tumors (BOTs) is of increasing concern. This study aimed to determine computed tomography (CT) features in differentiating stage 1 BOTs from stage I malignant epithelial ovarian tumors (MEOTs). A total of 170 ovarian masses (97 BOTs and 73 MEOTs) from 141 consecutive patients who underwent preoperative CT imaging were retrospectively analyzed. Two readers independently and retrospectively reviewed quantitative and qualitative CT features. Multivariate logistic analysis demonstrated that a larger tumor size (p = 0.0284 for reader 1, p = 0.0391 for reader 2) and a smaller solid component (p = 0.0007 for reader 1, p = 0.0003 for reader 2) were significantly associated with BOTs compared with MEOTs. In the subanalysis of cases with a solid component, smaller (p = 0.0092 for reader 1, p = 0.0014 for reader 2) and ill-defined (p = 0.0016 for reader 1, p = 0.0414 for reader 2) solid component was significantly associated with BOTs compared with MEOTs. Tumor size and the size and margin of the solid component were useful for differentiating stage 1 BOTs from stage 1 MEOTs on CT images.
- 28 January 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (3) , 480
Open AccessComputed Tomography Indicators for Differentiating Stage 1 Borderline Ovarian Tumors from Stage I Malignant Epithelial Ovarian Tumors
Preoperative diagnosis of borderline ovarian tumors (BOTs) is of increasing concern. This study aimed to determine computed tomography (CT) features in differentiating stage 1 BOTs from stage I malignant epithelial ovarian tumors (MEOTs). A total of 170 ovarian masses (97 BOTs and 73 MEOTs) from 141 consecutive patients who underwent preoperative CT imaging were retrospectively analyzed. Two readers independently and retrospectively reviewed quantitative and qualitative CT features. Multivariate logistic analysis demonstrated that a larger tumor size (p = 0.0284 for reader 1, p = 0.0391 for reader 2) and a smaller solid component (p = 0.0007 for reader 1, p = 0.0003 for reader 2) were significantly associated with BOTs compared with MEOTs. In the subanalysis of cases with a solid component, smaller (p = 0.0092 for reader 1, p = 0.0014 for reader 2) and ill-defined (p = 0.0016 for reader 1, p = 0.0414 for reader 2) solid component was significantly associated with BOTs compared with MEOTs. Tumor size and the size and margin of the solid component were useful for differentiating stage 1 BOTs from stage 1 MEOTs on CT images.
- Open Access
- 23 November 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (12) , 2168
Association of Hepatic Steatosis Index with Nonalcoholic Fatty Liver Disease Diagnosed by Non-Enhanced CT in a Screening Population
The noninvasive diagnosis of hepatic steatosis is of increasing concern. This study investigated the association of hepatic steatosis determined by non-enhanced CT criteria with clinical parameters in a screening population. Asymptomatic patients who underwent abdominal CT at our healthcare center were retrospectively analyzed (n = 339). Two radiologists measured the attenuation values of the liver parenchyma and spleen using non-enhanced CT images. CT criteria for hepatic steatosis were (a) absolute liver attenuation value <48 Hounsfield units (HU), (b) liver-to-spleen attenuation ratio <0.8, and (c) attenuation difference between the liver and spleen <−10. Body mass index (BMI) and hepatic steatosis index (HSI) were calculated, and laboratory findings were recorded. The association of hepatic steatosis with clinical parameters was assessed using univariate and logistic regression analyses. The presence of hepatic steatosis was significantly associated with the levels of serum fasting glucose and triglycerides, the alanine aminotransferase to aspartate aminotransferase (ALT/AST) ratio, BMI, and HSI values using any of the CT criteria. Logistic regression analysis revealed that the serum fasting glucose level and HSI were significantly associated with hepatic steatosis using criterion (a), while the ALT/AST ratio and HSI were associated with hepatic steatosis using criteria (b) and (c). The presence of hepatic steatosis on non-enhanced CT should be considered to indicate possible clinical profile abnormalities regarding metabolic syndrome.
- 23 November 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (12) , 2168
Open AccessAssociation of Hepatic Steatosis Index with Nonalcoholic Fatty Liver Disease Diagnosed by Non-Enhanced CT in a Screening Population
The noninvasive diagnosis of hepatic steatosis is of increasing concern. This study investigated the association of hepatic steatosis determined by non-enhanced CT criteria with clinical parameters in a screening population. Asymptomatic patients who underwent abdominal CT at our healthcare center were retrospectively analyzed (n = 339). Two radiologists measured the attenuation values of the liver parenchyma and spleen using non-enhanced CT images. CT criteria for hepatic steatosis were (a) absolute liver attenuation value <48 Hounsfield units (HU), (b) liver-to-spleen attenuation ratio <0.8, and (c) attenuation difference between the liver and spleen <−10. Body mass index (BMI) and hepatic steatosis index (HSI) were calculated, and laboratory findings were recorded. The association of hepatic steatosis with clinical parameters was assessed using univariate and logistic regression analyses. The presence of hepatic steatosis was significantly associated with the levels of serum fasting glucose and triglycerides, the alanine aminotransferase to aspartate aminotransferase (ALT/AST) ratio, BMI, and HSI values using any of the CT criteria. Logistic regression analysis revealed that the serum fasting glucose level and HSI were significantly associated with hepatic steatosis using criterion (a), while the ALT/AST ratio and HSI were associated with hepatic steatosis using criteria (b) and (c). The presence of hepatic steatosis on non-enhanced CT should be considered to indicate possible clinical profile abnormalities regarding metabolic syndrome.
- Open Access
- 1 September 2020
- Published by XMLink in Journal of the Korean Society of Radiology
- Vol. 81 (6) , 1436-1447
Prediction of Necrotizing Pancreatitis on Early CT Based on the Revised Atlanta Classification
송연선, et al. J Korean Soc Radiol. 2020 Aug;81:e64. https://doi.org/10.3348/jksr.2020.0012
- 1 September 2020
- Published by XMLink in Journal of the Korean Society of Radiology
- Vol. 81 (6) , 1436-1447
Open AccessPrediction of Necrotizing Pancreatitis on Early CT Based on the Revised Atlanta Classification
송연선, et al. J Korean Soc Radiol. 2020 Aug;81:e64. https://doi.org/10.3348/jksr.2020.0012
- Open Access
- 14 June 2020
- Published by Baishideng Publishing Group Inc. in World Journal of Gastroenterology
- Vol. 26 (22) , 2967-2986
Benign gallbladder diseases: Imaging techniques and tips for differentiating with malignant gallbladder diseases
Benign gallbladder diseases: Imaging techniques and tips for differentiating with malignant gallbladder diseases
- 14 June 2020
- Published by Baishideng Publishing Group Inc. in World Journal of Gastroenterology
- Vol. 26 (22) , 2967-2986
Open AccessBenign gallbladder diseases: Imaging techniques and tips for differentiating with malignant gallbladder diseases
Benign gallbladder diseases: Imaging techniques and tips for differentiating with malignant gallbladder diseases
- Open Access
- 1 January 2020
- Published by The Korean Urological Association in Investigative and Clinical Urology
- Vol. 61 (3) , 291-296
Korean ureter length: A computed tomography–based study
Jung SI, et al. Investig Clin Urol. 2020 May;61(3):291-296. https://doi.org/10.4111/icu.2020.61.3.291
- 1 January 2020
- Published by The Korean Urological Association in Investigative and Clinical Urology
- Vol. 61 (3) , 291-296
Open AccessKorean ureter length: A computed tomography–based study
Jung SI, et al. Investig Clin Urol. 2020 May;61(3):291-296. https://doi.org/10.4111/icu.2020.61.3.291
- Open Access
- 28 February 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (2) , e0210667
Shrinkage of hepatocellular carcinoma after radiofrequency ablation following transcatheter arterial chemoembolization: Analysis of contributing factors
This study was conducted to investigate tumor shrinkage and influencing factors in patients with hepatocellular carcinoma (HCC) from radiofrequency (RF) ablation following transcatheter arterial chemoembolization (TACE). A total of 222 patients underwent combined sequential treatment of TACE and RF ablation for HCC at our institution between 2008 and 2014. Of those, 86 patients (men, 68; women, 18) who achieved compact iodized oil tagging and complete ablation were included for this retrospective study. We measured three-dimensional tumor diameters and calculated tumor volumes on pre-treatment CT/MRI and follow-up CT scans performed post-TACE, post-ablation, and 1 month post-treatment, respectively. To compare periodically generated tumor diameters and volumes, repeated measures analysis of variance (ANOVA) was applied. Multiple linear regression analysis was performed to identify factors impacting tumor shrinkage after RF ablation. Diameters and volumes of HCCs declined significantly in the immediate aftermath of RF ablation (i.e., between post-TACE and post-ablation CT scans) (p < 0.001, for both). Mean reduction rates in tumor diameter and volume immediately after RF ablation were 18.2 ± 9.1% and 44.4 ± 14.6%, respectively. Of note, tumors of left hepatic lobe and in subphrenic or perivascular locations showed lower rates of post-ablative volume reduction than those in counterpart locations (p = 0.002, 0.046, 0.024, respectively). Tumor size and liver function did not influence tumor shrinkage after RF ablation. In patients with HCC, significant tumor shrinkage occurs immediately after RF ablation. The degree of shrinkage in response to ablative treatment seems to vary by tumor location.
- 28 February 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (2) , e0210667
Open AccessShrinkage of hepatocellular carcinoma after radiofrequency ablation following transcatheter arterial chemoembolization: Analysis of contributing factors
This study was conducted to investigate tumor shrinkage and influencing factors in patients with hepatocellular carcinoma (HCC) from radiofrequency (RF) ablation following transcatheter arterial chemoembolization (TACE). A total of 222 patients underwent combined sequential treatment of TACE and RF ablation for HCC at our institution between 2008 and 2014. Of those, 86 patients (men, 68; women, 18) who achieved compact iodized oil tagging and complete ablation were included for this retrospective study. We measured three-dimensional tumor diameters and calculated tumor volumes on pre-treatment CT/MRI and follow-up CT scans performed post-TACE, post-ablation, and 1 month post-treatment, respectively. To compare periodically generated tumor diameters and volumes, repeated measures analysis of variance (ANOVA) was applied. Multiple linear regression analysis was performed to identify factors impacting tumor shrinkage after RF ablation. Diameters and volumes of HCCs declined significantly in the immediate aftermath of RF ablation (i.e., between post-TACE and post-ablation CT scans) (p < 0.001, for both). Mean reduction rates in tumor diameter and volume immediately after RF ablation were 18.2 ± 9.1% and 44.4 ± 14.6%, respectively. Of note, tumors of left hepatic lobe and in subphrenic or perivascular locations showed lower rates of post-ablative volume reduction than those in counterpart locations (p = 0.002, 0.046, 0.024, respectively). Tumor size and liver function did not influence tumor shrinkage after RF ablation. In patients with HCC, significant tumor shrinkage occurs immediately after RF ablation. The degree of shrinkage in response to ablative treatment seems to vary by tumor location.
- 1 September 2018
- Published by Elsevier in Clinical Imaging
- Vol. 51, 50-58
Estimation of hepatic fat fraction using modified Dixon magnetic resonance imaging techniques: effect of liver cirrhosis
- 1 September 2018
- Published by Elsevier in Clinical Imaging
- Vol. 51, 50-58
Estimation of hepatic fat fraction using modified Dixon magnetic resonance imaging techniques: effect of liver cirrhosis