Fu Wing Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Fu Wing Yu has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Kwok Tai Chan
Department of Building Services Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, China
42 shared publications K.T. Chan
7 shared publicationsJ. Yang
6 shared publicationsR.K.Y. Sit
6 shared publicationsW.T. Ho
4 shared publicationsJia Yang
Department of Building Services Engineering The Hong Kong Polytechnic University Hong Kong
3 shared publications
Latest Publications
- Open Access
- 11 December 2023
- Published by Elsevier in Cleaner Energy Systems
- Vol. 7
Optimizing hybrid ventilation and daylight-linked dimming control for carbon reduction and thermal comfort in a subtropical high-rise office building
- 11 December 2023
- Published by Elsevier in Cleaner Energy Systems
- Vol. 7
Open AccessOptimizing hybrid ventilation and daylight-linked dimming control for carbon reduction and thermal comfort in a subtropical high-rise office building
- Open Access
- 18 April 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (8) , 6793
Time Series Forecast of Cooling Demand for Sustainable Chiller System in an Office Building in a Subtropical Climate
Commercial buildings can take up one-third of the energy related carbon emissions. There is limited research on forecasting cooling demands to evaluate sustainable air conditioning systems under climate change. This paper develops a simplified cooling demand model based on the time series of climatic and architectural variables to analyze carbon reduction by a sustainable chiller system. EnergyPlus is used to simulate hourly cooling demands of a hypothesized high-rise office building in Hong Kong under a change of architectural parameters and future climate conditions. An hourly cooling demand model with R2 above 0.9 is developed with inputs of the window-to-wall ratio, outdoor air enthalpy, global solar radiation, wind speed and their two steps ahead. The validated model is then used to analyze carbon reduction potentials by free cooling and a full variable speed chiller system. The low carbon technologies reduce carbon emissions by over 20% with but the reduction shrinks to 2.51–4.93% under future climate conditions. The novelty of this study is the simplified cooling demand model based on the time series of climatic and architectural variables. The significances of this study are to quantify carbon reduction by a sustainable chiller system under climate change and to appeal for more carbon reduction technologies for carbon neutrality.
- 18 April 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (8) , 6793
Open AccessTime Series Forecast of Cooling Demand for Sustainable Chiller System in an Office Building in a Subtropical Climate
Commercial buildings can take up one-third of the energy related carbon emissions. There is limited research on forecasting cooling demands to evaluate sustainable air conditioning systems under climate change. This paper develops a simplified cooling demand model based on the time series of climatic and architectural variables to analyze carbon reduction by a sustainable chiller system. EnergyPlus is used to simulate hourly cooling demands of a hypothesized high-rise office building in Hong Kong under a change of architectural parameters and future climate conditions. An hourly cooling demand model with R2 above 0.9 is developed with inputs of the window-to-wall ratio, outdoor air enthalpy, global solar radiation, wind speed and their two steps ahead. The validated model is then used to analyze carbon reduction potentials by free cooling and a full variable speed chiller system. The low carbon technologies reduce carbon emissions by over 20% with but the reduction shrinks to 2.51–4.93% under future climate conditions. The novelty of this study is the simplified cooling demand model based on the time series of climatic and architectural variables. The significances of this study are to quantify carbon reduction by a sustainable chiller system under climate change and to appeal for more carbon reduction technologies for carbon neutrality.
- 4 March 2021
- Published by Taylor & Francis in Engineering Optimization
- Vol. 54 (3) , 504-523
Variable importance for chiller system optimization and sustainability
Very few studies have considered modelling the statuses of loading and component combinations (LC) in chiller systems. This study uses a decision tree (DT) and a neural network (NN) to model accurately six output levels of LC in terms of 11 predictor variables. The NN model gave a higher correct prediction of 89.52% than 84.44% in the DT model. A variable dropout analysis from the DT and NN models generalizes the top five significant variables: the statuses of cooling towers and primary chilled water pumps, and the supply temperature, return temperature and flow rate of chilled water. The system coefficient of performance (SCOP) modelled by NN has an improved R2 of 84.18% versus 74.62% when the significant variables are included as inputs. The SCOP maximization brings three optimal strategies—implementing chiller sequencing, operating components in pairs and optimizing chilled water supply temperature—which reduce CO2 emissions by 99,815–346,987 kg.
- 4 March 2021
- Published by Taylor & Francis in Engineering Optimization
- Vol. 54 (3) , 504-523
Variable importance for chiller system optimization and sustainability
Very few studies have considered modelling the statuses of loading and component combinations (LC) in chiller systems. This study uses a decision tree (DT) and a neural network (NN) to model accurately six output levels of LC in terms of 11 predictor variables. The NN model gave a higher correct prediction of 89.52% than 84.44% in the DT model. A variable dropout analysis from the DT and NN models generalizes the top five significant variables: the statuses of cooling towers and primary chilled water pumps, and the supply temperature, return temperature and flow rate of chilled water. The system coefficient of performance (SCOP) modelled by NN has an improved R2 of 84.18% versus 74.62% when the significant variables are included as inputs. The SCOP maximization brings three optimal strategies—implementing chiller sequencing, operating components in pairs and optimizing chilled water supply temperature—which reduce CO2 emissions by 99,815–346,987 kg.
- 1 June 2020
- Published by Elsevier in International Journal of Refrigeration
- Vol. 114, 47-53
Determinants of low energy performance in a multi-chiller system serving an educational premise
- 1 June 2020
- Published by Elsevier in International Journal of Refrigeration
- Vol. 114, 47-53
Determinants of low energy performance in a multi-chiller system serving an educational premise
- Open Access
- 1 January 2018
- Published by National Library of Serbia in Thermal Science
- Vol. 22 (1 Part A) , 193-204
Cooling effectiveness of mist precooler for improving energy performance of air-cooled chiller
Mist is increasingly applied to precool outdoor air in heat rejection. This study investigates how the coefficient of performance (COP) of an air-cooled chiller varies with a mist precooler at different levels of cooling effectiveness. A multivariate regression model was developed to simulate the operating variables of an air-cooled chiller with mist precooling. The model was validated with typical performance data of an air-cooled centrifugal chiller. The COP would increase by up to 30%, depending on the cooling effectiveness and the wet bulb depression-the difference between the dry bulb and wet bulb temperatures of outdoor air. At a large wet bulb depression, the percentage increase of COP tended to correlate linearly with the chiller capacity. Yet at a small wet bulb depression, the dynamic control of condensing temperature resulted in a non-linear relationship between the percentage change of COP and the cooling effectiveness. Further experimental work is required to optimize cooling effectiveness for the maximum COP.
- 1 January 2018
- Published by National Library of Serbia in Thermal Science
- Vol. 22 (1 Part A) , 193-204
Open AccessCooling effectiveness of mist precooler for improving energy performance of air-cooled chiller
Mist is increasingly applied to precool outdoor air in heat rejection. This study investigates how the coefficient of performance (COP) of an air-cooled chiller varies with a mist precooler at different levels of cooling effectiveness. A multivariate regression model was developed to simulate the operating variables of an air-cooled chiller with mist precooling. The model was validated with typical performance data of an air-cooled centrifugal chiller. The COP would increase by up to 30%, depending on the cooling effectiveness and the wet bulb depression-the difference between the dry bulb and wet bulb temperatures of outdoor air. At a large wet bulb depression, the percentage increase of COP tended to correlate linearly with the chiller capacity. Yet at a small wet bulb depression, the dynamic control of condensing temperature resulted in a non-linear relationship between the percentage change of COP and the cooling effectiveness. Further experimental work is required to optimize cooling effectiveness for the maximum COP.
- 1 March 2017
- Published by Elsevier in Energy and Buildings
- Vol. 139, 653-664
Critique of operating variables importance on chiller energy performance using random forest
- 1 March 2017
- Published by Elsevier in Energy and Buildings
- Vol. 139, 653-664
Critique of operating variables importance on chiller energy performance using random forest
- 1 January 2017
- Published by Elsevier in International Journal of Refrigeration
- Vol. 73, 54-64
Economic analysis of air-cooled chiller with advanced heat rejection
- 1 January 2017
- Published by Elsevier in International Journal of Refrigeration
- Vol. 73, 54-64
Economic analysis of air-cooled chiller with advanced heat rejection
- 27 October 2016
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 23 (2) , 334-344
Analysis of centrifugal chillers with oil-free magnetic bearings for enhancing building energy performance
This article examines the actual operating performance of centrifugal chillers with oil-free magnetic bearings (hereafter oil-free chillers) to analyze energy saving potentials for commercial buildings. A chiller system retrofit for a shopping arcade involved replacing three existing constant speed water-cooled centrifugal chillers by three oil-free centrifugal chillers of the same capacity. The coefficient of performance was calculated based on operating data logged at 1-h intervals for over 1 year before and after replacement. Oil-free chillers with variable speed control operated at a higher coefficient of performance under part load conditions, reducing the total electricity consumption of the shopping arcade by 9.6%. If the average technical efficiency in data envelopment analysis was improved to 1 from 0.6 in the existing case, the average system coefficient of performance could increase from 6.2 to 10.3. The improvement involved controlling the temperature of supply chilled water at a lower boundary curve and operating an equal percentage of capacity among chillers. It is economically viable to design an all-variable speed chiller system with oil-free chillers instead of the conventional constant speed system for a reference office building in a subtropical climate.
- 27 October 2016
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 23 (2) , 334-344
Analysis of centrifugal chillers with oil-free magnetic bearings for enhancing building energy performance
This article examines the actual operating performance of centrifugal chillers with oil-free magnetic bearings (hereafter oil-free chillers) to analyze energy saving potentials for commercial buildings. A chiller system retrofit for a shopping arcade involved replacing three existing constant speed water-cooled centrifugal chillers by three oil-free centrifugal chillers of the same capacity. The coefficient of performance was calculated based on operating data logged at 1-h intervals for over 1 year before and after replacement. Oil-free chillers with variable speed control operated at a higher coefficient of performance under part load conditions, reducing the total electricity consumption of the shopping arcade by 9.6%. If the average technical efficiency in data envelopment analysis was improved to 1 from 0.6 in the existing case, the average system coefficient of performance could increase from 6.2 to 10.3. The improvement involved controlling the temperature of supply chilled water at a lower boundary curve and operating an equal percentage of capacity among chillers. It is economically viable to design an all-variable speed chiller system with oil-free chillers instead of the conventional constant speed system for a reference office building in a subtropical climate.