YLYueqin Li

Yueqin Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yueqin Li has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Jin Yuan

    Key Laboratory of All Optical Network & Advanced Telecommunication Network of Ministry of Education, Institute of Lightwave Technology, Beijing Jiaotong University, Beijing, China

    1 shared publication
  • Jing Li

    Key Laboratory of All Optical Network & Advanced Telecommunication Network of Ministry of Education, Institute of Lightwave Technology, Beijing Jiaotong University, Beijing, China

    1 shared publication
  • Li Pei

    Beijing Jiaotong University

    1 shared publication
  • Tigang Ning

    Key Laboratory of All Optical Network & Advanced Telecommunication Network of Ministry of Education, Institute of Lightwave Technology, Beijing Jiaotong University, Beijing, China

    1 shared publication
  • Yiqun Wang

    Key Laboratory of All Optical Network & Advanced Telecommunication Network of Ministry of Education, Institute of Lightwave Technology, Beijing Jiaotong University, Beijing, China

    1 shared publication

Latest Publications

  • Open Access

    Photonic instantaneous frequency measurement of wideband microwave signals

    by Yueqin Li, Li Pei, Jing Li, Yiqun Wang, Jin Yuan, Tigang Ning

    We propose a photonic system for instantaneous frequency measurement (IFM) of wideband microwave signals with a tunable measurement range and resolution based on a polarization-maintaining fiber Bragg grating (PM-FBG). Firstly, in order to be insensitive to laser power fluctuation, we aim at generating two different frequency to amplitude characteristics so that we can normalize them to obtain an amplitude comparison function (ACF). Then we encode these two different wavelengths in two perpendicular polarizations by using the PM-FBG which shows different transmission profiles at two polarizations. The ACF is capable of being adjusted by tuning polarization angle, therefore the measurement range and resolution are tunable. By theoretical analyses and simulated verification, a frequency measurement range of 0~17.2 GHz with average resolution of ±0.12 GHz can be achieved, which signifies a wide measurement range with relatively high resolution. Our system does not require large optical bandwidth for the components because the wavelength spacing can be small, making the system affordable, stable, and reliable with more consistent characteristics due to the narrowband nature of the optical parts. PM-FBG with high integration can be potentially used for more polarization manipulating systems and the use of a single-polarization dual-wavelength laser can simplify the architecture and enhance the stability.