LCLili Chen

Lili Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lili Chen has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Fugang Xu

    Key Laboratory of Functional Small Organic Molecule, Ministry of Education, Jiangxi Province, People's Republic of China

    1 shared publication
  • Hongliang Tan

    Key Laboratory of Functional Small Organic Molecule, Ministry of Education, Jiangxi Province, People's Republic of China

    1 shared publication
  • Juan Hao

    Key Laboratory of Functional Small Organic Molecule, Ministry of Education, College of Chemistry and Chemical Engineering, Jiangxi Normal University, Nanchang, China

    1 shared publication
  • Li Wang

    Key Laboratory of Functional Small Organic Molecule, Ministry of Education, Jiangxi Province, People's Republic of China

    1 shared publication
  • Li Wang

    National Engineering Research Center for Carbohydrate Synthesis/Key Lab of Fluorine and Silicon for Energy Materials and Chemistry of Ministry of Education, College of Chemistry and Materials, Jiangxi Normal University, Nanchang, China

    1 shared publication
  • Nan Liu

    Key Laboratory of Functional Small Organic Molecule, Ministry of Education, College of Chemistry and Chemical Engineering, Jiangxi Normal University, Nanchang, China

    1 shared publication

Latest Publications

  • Ratiometric fluorescent detection of Cu2+ based on dual‐emission ZIF‐8@rhodamine‐B nanocomposites

    by Nan Liu, Juan Hao, Lili Chen, Yonghai Song, Li Wang

    Zeolitic imidazolate framework‐8 (ZIF‐8) loading rhodamine‐B (ZIF‐8@rhodamine‐B) nanocomposites was proposed and used as ratiometric fluorescent sensor to detect copper(II) ion (Cu2+). Scanning electron microscopy, Fourier transform infrared spectroscopy, X‐ray powder diffraction, nitrogen adsorption/desorption isotherms and fluorescence emission spectroscopy were employed to characterize the ZIF‐8@rhodamine‐B nanocomposites. The results showed the rhodamine‐B was successfully assembled on ZIF‐8 based on the π‐π interaction and the hydrogen bond between the nitrogen atom of ZIF‐8 and –COOH of rhodamine‐B. The as‐obtained ZIF‐8@rhodamine‐B nanocomposites were octahedron with size about 150–200 nm, had good water dispersion, and exhibited the characteristic fluorescence emission of ZIF‐8 at 335 nm and rhodamine‐B at 575 nm. The Cu2+ could quench fluorescence of ZIF‐8 rather than rhodamine‐B. The ZIF‐8 not only acted as the template to assemble rhodamine‐B, but also was employed as the signal fluorescence together with the fluorescence of rhodamine‐B as the reference to construct a novel ratiometric fluorescent sensor to detect Cu2+. The resulted ZIF‐8@rhodamine‐B nanocomposite fluorescence probe showed good linear range (68.4 nM to 125 μM) with a low detection limit (22.8 nM) for Cu2+ combined with good sensitivity and selectivity. The work also provides a better way to design ratiometric fluorescent sensors from ZIF‐8 and other fluorescent molecules.


  • Open Access

    Terbium (III) coordination polymer–copper (II) compound as fluorescent probe for time‐resolved fluorescence ‘turn‐on’ detection of hydrogen sulfide

    by Lili Chen, Hongliang Tan, Fugang Xu, Li Wang

    With recognition of the biological importance of hydrogen sulfide (H2S), we present a simple and effective fluorescent probe for H2S using a Tb3+ coordination polymer–Cu2+ compound (DPA/Tb/G–Cu2+). Dipicolinic acid (DPA) and guanosine (G) can coordinate with Tb3+ to form a macromolecular coordination polymer (DPA/Tb/G). DPA/Tb/G specifically binds to Cu2+ in the presence of coexisting cations, and obvious fluorescence quenching is observed. The quenched fluorescence can be exclusively recovered upon the addition of sulfide, which is measured in the mode of time‐resolved fluorescence. The fluorescence intensities of the DPA/Tb/G–Cu2+ compound enhance linearly with increasing sulfide concentrations from 1 to 30 μM. The detection limit for sulfide in aqueous solution is estimated to be 0.3 μM (at 3σ). The DPA/Tb/G–Cu2+ compound was successfully applied to sense H2S in human serum samples and exhibited a satisfactory result. It displays some desirable properties, such as fast detection procedure, high selectivity and excellent sensitivity. This method is very promising to be utilized for practical detection of H2S in biological and environmental samples.