Maria Alejandra Md Henriquez
Maria Alejandra Md Henriquez has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
- Luis Izquierdo
Research Department, Oftalmosalud Institute of Eyes, Lima, Peru
14 shared publications Luis Izquierdo
4 shared publicationsLuis Jr Md Izquierdo
Research Department, Oftalmosalud Institute of Eyes, San Isidro, Lima 27, Perú
4 shared publicationsJorge Camargo
Oftalmosalud Inst Eyes, Res Dept, Lima, Peru
3 shared publicationsJose Chauca
Research Department, Oftalmosalud Institute of Eyes, Lima 27, Peru
3 shared publicationsMartin McCarthy
Research Department, Instituto de Ojos Oftalmosalud, Lima, Peru
3 shared publications
Latest Publications
- 5 December 2025
- Published by Wolters Kluwer Health in Cornea
- Vol. 45 (12) , 1533-1538
Utility of Stromal Thickness Maps in Surgical Decision Making for Corneal Crosslinking in Patients With Keratoconus
Purpose: To assess the effect of surgical decision making on the type of corneal crosslinking (CXL) protocol in eyes with keratoconus (KC) based on stromal thickness maps and thinnest corneal pachymetry (TCP). Methods: A prospective, nonrandomized cohort study was performed between January 2022 and January 2023. Patients were allocated to Epi-off or transepithelial CXL (TE-CXL) procedures depending on the TCP value using Scheimpflug. TCP ≥450 μm was used to designate patient's eye to the Epi-off CXL procedure and TCP <450 μm to TE-CXL. On the same day, a combined Placido and Anterior Segment OCT evaluation was performed to assess epithelial thickness (ET) and minimum stromal thickness (MinST). The type of surgery was then finally selected: Epi-off CXL was indicated when MinST ≥400 μm, whereas TE-CXL procedure was indicated when MinST <400 μm. We assessed the percentage of cases in which MinST data changed the surgical decision (Utility). Results: The study included 245 eyes, MinST was 407.26 ± 50.92 (range 223–497). Stromal thickness maps assessed before surgery altered the surgeon's decision making in 5.30% (13 out of 245) of cases. The procedure was changed from Epi-off to TE-CXL and from TE-CXL to Epi-Off in 3.67% and 1.63% of the cases, respectively. Conclusions: Anterior segment optical coherence tomography stromal thickness maps have minimal impact on the surgical decision making for conventional Epi-off and TE-CXL protocols. Considering that MinST data provide objective information on stromal thickness, unlike TCP, and avoid the need for deepithelialization, their implications in sub-400 protocols may be greater.
- 5 December 2025
- Published by Wolters Kluwer Health in Cornea
- Vol. 45 (12) , 1533-1538
Utility of Stromal Thickness Maps in Surgical Decision Making for Corneal Crosslinking in Patients With Keratoconus
Purpose: To assess the effect of surgical decision making on the type of corneal crosslinking (CXL) protocol in eyes with keratoconus (KC) based on stromal thickness maps and thinnest corneal pachymetry (TCP). Methods: A prospective, nonrandomized cohort study was performed between January 2022 and January 2023. Patients were allocated to Epi-off or transepithelial CXL (TE-CXL) procedures depending on the TCP value using Scheimpflug. TCP ≥450 μm was used to designate patient's eye to the Epi-off CXL procedure and TCP <450 μm to TE-CXL. On the same day, a combined Placido and Anterior Segment OCT evaluation was performed to assess epithelial thickness (ET) and minimum stromal thickness (MinST). The type of surgery was then finally selected: Epi-off CXL was indicated when MinST ≥400 μm, whereas TE-CXL procedure was indicated when MinST <400 μm. We assessed the percentage of cases in which MinST data changed the surgical decision (Utility). Results: The study included 245 eyes, MinST was 407.26 ± 50.92 (range 223–497). Stromal thickness maps assessed before surgery altered the surgeon's decision making in 5.30% (13 out of 245) of cases. The procedure was changed from Epi-off to TE-CXL and from TE-CXL to Epi-Off in 3.67% and 1.63% of the cases, respectively. Conclusions: Anterior segment optical coherence tomography stromal thickness maps have minimal impact on the surgical decision making for conventional Epi-off and TE-CXL protocols. Considering that MinST data provide objective information on stromal thickness, unlike TCP, and avoid the need for deepithelialization, their implications in sub-400 protocols may be greater.
- Open Access
- 13 May 2025
- Published by Wolters Kluwer Health in Cornea
- Vol. 45 (6) , 694-705
Latin American Consensus on Ocular Lubricants and Dry Eye Disease (LUBOS): A Report on Severity Classification, Diagnosis, and Therapy
Purpose: This consensus aims to establish a practical severity classification for applying a tailored stepladder treatment algorithm helpful to any clinician. Methods: A modified Delphi methodology was used to establish a consensus on the definition, diagnosis, severity classification, and treatment algorithms for dry eye disease (DED) adapted to the needs of Latin America. The consensus focused on promoting the effective use of lubricants and providing straightforward, practical guidance for ophthalmologists treating dry eyes. Twenty-eight corneal specialists from representative Latin American countries reviewed the scientific evidence and drew on their expertise to answer specifically designed open-ended questions. Results: A simple diagnostic algorithm (clinical history, DED questionnaire, and dry eye clinical tests) identified patients with the disease. A practical severity classification system of four grades: mild, moderate, severe, and LUBOS plus DED was based on four criteria: OSDI, film break-up time, Sjögren International Collaborative Clinical Alliance ocular surface staining score, and international workshop on meibomian gland dysfunction meibomian gland functionality test. For classification, ≥2 criteria of the highest severity grade from the worse eye were considered. A stepladder therapeutic algorithm aligned with disease severity consisted of 5 steps, each with proposed and recommended treatment alternatives. Patient education, lifestyle recommendations, adverse environment avoidance, lubricants, and eyelid therapy were reinforced during the therapy period. Conclusions: The LUBOS expert panel consensus considered the diverse geoenvironmental, socioeconomic, cultural, and ethnic factors pertinent to Latin America. This consensus offers an accessible and cost-effective tool, enabling professionals to detect, evaluate, and grade the severity of dry eye disease effectively for planning adequate therapeutic strategies that can be monitored with confidence.
- 13 May 2025
- Published by Wolters Kluwer Health in Cornea
- Vol. 45 (6) , 694-705
Open AccessLatin American Consensus on Ocular Lubricants and Dry Eye Disease (LUBOS): A Report on Severity Classification, Diagnosis, and Therapy
Purpose: This consensus aims to establish a practical severity classification for applying a tailored stepladder treatment algorithm helpful to any clinician. Methods: A modified Delphi methodology was used to establish a consensus on the definition, diagnosis, severity classification, and treatment algorithms for dry eye disease (DED) adapted to the needs of Latin America. The consensus focused on promoting the effective use of lubricants and providing straightforward, practical guidance for ophthalmologists treating dry eyes. Twenty-eight corneal specialists from representative Latin American countries reviewed the scientific evidence and drew on their expertise to answer specifically designed open-ended questions. Results: A simple diagnostic algorithm (clinical history, DED questionnaire, and dry eye clinical tests) identified patients with the disease. A practical severity classification system of four grades: mild, moderate, severe, and LUBOS plus DED was based on four criteria: OSDI, film break-up time, Sjögren International Collaborative Clinical Alliance ocular surface staining score, and international workshop on meibomian gland dysfunction meibomian gland functionality test. For classification, ≥2 criteria of the highest severity grade from the worse eye were considered. A stepladder therapeutic algorithm aligned with disease severity consisted of 5 steps, each with proposed and recommended treatment alternatives. Patient education, lifestyle recommendations, adverse environment avoidance, lubricants, and eyelid therapy were reinforced during the therapy period. Conclusions: The LUBOS expert panel consensus considered the diverse geoenvironmental, socioeconomic, cultural, and ethnic factors pertinent to Latin America. This consensus offers an accessible and cost-effective tool, enabling professionals to detect, evaluate, and grade the severity of dry eye disease effectively for planning adequate therapeutic strategies that can be monitored with confidence.
- 25 March 2025
- Published by Wolters Kluwer Health in Cornea
- Vol. 45 (1) , 41-50
Long-term Tomographic, Refractive, and Visual Analysis of Keratoconus Eyes With Extreme Corneal Flattening After Corneal Cross-linking
Purpose: To evaluate the long-term tomographic, refractive, and visual characteristics of eyes with extreme corneal flattening after corneal cross-linking (CXL) for progressive keratoconus. Methods: A retrospective observational study included eyes that underwent corneal CXL with epithelial removal between June 2006 and March 2017 and had extreme keratometric flattening [greater than 5 diopters (D)] and a minimum follow-up of 5 years. Visual, tomographic, pachymetric, and refractive characteristics were evaluated. Results: Mean follow-up time was 7.6 ± 2.6 years (range 5–13 years). Fifteen eyes were included in the study. Mean maximum keratometric (Kmax) flattening was −7.58 ± 2.63 D [range 5.0–12.2 D, ( P <0.001)]. Approximately 56.25% (9/15) of the eyes experienced progressive flattening over the years. And 40% (6/15) presented an improvement of one or more lines of corrected distance visual acuity (CDVA), and 26.6% (5/16) of the eyes showed a worsening of CDVA. Logistic regression analysis revealed that postoperative Kmax flattening greater than 2 D at the first year postop (odds ratio 17.7, 95% confidence interval, 4.4–71.2) and preoperative Kmax greater than 55 D (odds ratio 8.8, 95% confidence interval, 2.7–28.3) were significant risk factors for extreme postop keratometric flattening. Conclusions: Progressive extreme corneal flattening when accompanied with a decrease of CDVA was a late complication of CXL that may have required corneal transplantation for visual rehabilitation. Preoperative steeper corneas and keratometric flattening greater than 2 D at the first year postoperative period were risk factors associated with long-term extreme postoperative corneal flattening.
- 25 March 2025
- Published by Wolters Kluwer Health in Cornea
- Vol. 45 (1) , 41-50
Long-term Tomographic, Refractive, and Visual Analysis of Keratoconus Eyes With Extreme Corneal Flattening After Corneal Cross-linking
Purpose: To evaluate the long-term tomographic, refractive, and visual characteristics of eyes with extreme corneal flattening after corneal cross-linking (CXL) for progressive keratoconus. Methods: A retrospective observational study included eyes that underwent corneal CXL with epithelial removal between June 2006 and March 2017 and had extreme keratometric flattening [greater than 5 diopters (D)] and a minimum follow-up of 5 years. Visual, tomographic, pachymetric, and refractive characteristics were evaluated. Results: Mean follow-up time was 7.6 ± 2.6 years (range 5–13 years). Fifteen eyes were included in the study. Mean maximum keratometric (Kmax) flattening was −7.58 ± 2.63 D [range 5.0–12.2 D, ( P <0.001)]. Approximately 56.25% (9/15) of the eyes experienced progressive flattening over the years. And 40% (6/15) presented an improvement of one or more lines of corrected distance visual acuity (CDVA), and 26.6% (5/16) of the eyes showed a worsening of CDVA. Logistic regression analysis revealed that postoperative Kmax flattening greater than 2 D at the first year postop (odds ratio 17.7, 95% confidence interval, 4.4–71.2) and preoperative Kmax greater than 55 D (odds ratio 8.8, 95% confidence interval, 2.7–28.3) were significant risk factors for extreme postop keratometric flattening. Conclusions: Progressive extreme corneal flattening when accompanied with a decrease of CDVA was a late complication of CXL that may have required corneal transplantation for visual rehabilitation. Preoperative steeper corneas and keratometric flattening greater than 2 D at the first year postoperative period were risk factors associated with long-term extreme postoperative corneal flattening.
- 12 December 2024
- Published by Wolters Kluwer Health in Cornea
- Vol. 44 (11) , 1341-1351
Definition of Progressive Keratoconus: A Systematic Review
Purpose: To identify the definitions used for progressive keratoconus in the literature. Methods: A systematic literature review aimed to identify the definitions used for “progressive keratoconus” in the published articles. A comprehensive search from January 2018 to May 2023 was conducted across Cochrane Library, PubMed, Taylor & Francis, Web of Science, and other bibliographic databases at Oftalmosalud, Lima, Peru. The inclusion criteria were articles including patients with keratoconus without any previous surgical procedure and containing the definition of “progressive keratoconus” or “keratoconus progression” and a sample size greater than 10 eyes. Results: A total of 221 articles were included for analysis. The 3 most frequent parameters to define progression included data from anterior curvature, pachymetry, and refraction used in 97.8% (216/221), 37.6% (83/221), and 32.1% (71/221) of the articles, respectively. Specifically, the most frequent criterion used was maximum keratometry (Kmax), used in 85.5% (189/221) of the articles. Progression was assessed between 6- and 12-month follow-up in 64.7% (143/221) of the articles. Data from posterior cornea were used in only 8.1% (18/221) of the studies. None of the studies included data from the corneal epithelium. Conclusions: The present study demonstrates the lack of unified criteria to define progression of keratoconus and an underutilization of the technology described. It also shows that the single point Kmax measurement is the most commonly used criterion, followed by a change in refractive astigmatism and thinning at the thinnest pachymetric point.
- 12 December 2024
- Published by Wolters Kluwer Health in Cornea
- Vol. 44 (11) , 1341-1351
Definition of Progressive Keratoconus: A Systematic Review
Purpose: To identify the definitions used for progressive keratoconus in the literature. Methods: A systematic literature review aimed to identify the definitions used for “progressive keratoconus” in the published articles. A comprehensive search from January 2018 to May 2023 was conducted across Cochrane Library, PubMed, Taylor & Francis, Web of Science, and other bibliographic databases at Oftalmosalud, Lima, Peru. The inclusion criteria were articles including patients with keratoconus without any previous surgical procedure and containing the definition of “progressive keratoconus” or “keratoconus progression” and a sample size greater than 10 eyes. Results: A total of 221 articles were included for analysis. The 3 most frequent parameters to define progression included data from anterior curvature, pachymetry, and refraction used in 97.8% (216/221), 37.6% (83/221), and 32.1% (71/221) of the articles, respectively. Specifically, the most frequent criterion used was maximum keratometry (Kmax), used in 85.5% (189/221) of the articles. Progression was assessed between 6- and 12-month follow-up in 64.7% (143/221) of the articles. Data from posterior cornea were used in only 8.1% (18/221) of the studies. None of the studies included data from the corneal epithelium. Conclusions: The present study demonstrates the lack of unified criteria to define progression of keratoconus and an underutilization of the technology described. It also shows that the single point Kmax measurement is the most commonly used criterion, followed by a change in refractive astigmatism and thinning at the thinnest pachymetric point.
- 8 October 2024
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 51 (1) , 50
Letters to the Editor
- 8 October 2024
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 51 (1) , 50
Letters to the Editor
- 7 May 2024
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 50 (7) , 283-291
Morphological Features Among Gaussian, Sagittal, and Tangential Curvature Maps in Normal and Keratoconus Eyes Using Anterior Segment Optical Coherence Tomography
Purpose: To investigate and compare the morphological features and differences among Gaussian, Sagittal, and Tangential anterior corneal curvature maps obtained with an anterior segment optical coherence tomographer combined with a Placido disc MS-39 device in keratoconus (KC) and normal eyes. Methods: Prospective, cross-sectional study including 37 KC and 51 healthy eyes. The pattern of astigmatism and maximum keratometry (Kmax), keratometry at the thinnest point (Ktp) and 2 mm diameter (K2mm), and inferior–superior dioptric asymmetry values were obtained and calculated from Gaussian, Tangential, and Sagittal curvature maps using the MS-39 (CSO). Results: In KC eyes, an asymmetric bowtie pattern was observed in 64.86% (24/37), 64.86% (24/37), and 0% in the Sagittal, Tangential, and Gaussian maps, respectively. In normal eyes, 51.0% (26/51), 51.0% (26/51), and 0% showed a symmetric bowtie pattern in the Sagittal, Tangential, and Gaussian maps, respectively. There was a significant difference for the variables Kmax, Ktp, and K2mm inferior among the Gaussian, Tangential, and Sagittal maps in both normal and KC groups. Sensitivity discriminating between normal and KC eyes was 100%, 97.3%, and 90.9% and specificity was 94.1%, 100%, and 100% for Kmax coming from the Tangential, Gaussian, and Sagittal maps, respectively. Conclusions: Gaussian maps displayed significantly different morphological features when compared with Sagittal and Tangential maps in normal and KC eyes. Anterior curvature maps from Gaussian maps do not show the morphological pattern of symmetric bowtie in normal eyes nor asymmetric bowtie in KC eyes. Kmax from Gaussian maps are more specific, however less sensitive than Tangential maps in discriminating KC from normal eyes.
- 7 May 2024
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 50 (7) , 283-291
Morphological Features Among Gaussian, Sagittal, and Tangential Curvature Maps in Normal and Keratoconus Eyes Using Anterior Segment Optical Coherence Tomography
Purpose: To investigate and compare the morphological features and differences among Gaussian, Sagittal, and Tangential anterior corneal curvature maps obtained with an anterior segment optical coherence tomographer combined with a Placido disc MS-39 device in keratoconus (KC) and normal eyes. Methods: Prospective, cross-sectional study including 37 KC and 51 healthy eyes. The pattern of astigmatism and maximum keratometry (Kmax), keratometry at the thinnest point (Ktp) and 2 mm diameter (K2mm), and inferior–superior dioptric asymmetry values were obtained and calculated from Gaussian, Tangential, and Sagittal curvature maps using the MS-39 (CSO). Results: In KC eyes, an asymmetric bowtie pattern was observed in 64.86% (24/37), 64.86% (24/37), and 0% in the Sagittal, Tangential, and Gaussian maps, respectively. In normal eyes, 51.0% (26/51), 51.0% (26/51), and 0% showed a symmetric bowtie pattern in the Sagittal, Tangential, and Gaussian maps, respectively. There was a significant difference for the variables Kmax, Ktp, and K2mm inferior among the Gaussian, Tangential, and Sagittal maps in both normal and KC groups. Sensitivity discriminating between normal and KC eyes was 100%, 97.3%, and 90.9% and specificity was 94.1%, 100%, and 100% for Kmax coming from the Tangential, Gaussian, and Sagittal maps, respectively. Conclusions: Gaussian maps displayed significantly different morphological features when compared with Sagittal and Tangential maps in normal and KC eyes. Anterior curvature maps from Gaussian maps do not show the morphological pattern of symmetric bowtie in normal eyes nor asymmetric bowtie in KC eyes. Kmax from Gaussian maps are more specific, however less sensitive than Tangential maps in discriminating KC from normal eyes.
- Open Access
- 10 April 2024
- Published by Elsevier in JFO Open Ophthalmology
- Vol. 6
Female representation on editorial boards of leading ophthalmology journals
- 10 April 2024
- Published by Elsevier in JFO Open Ophthalmology
- Vol. 6
Open AccessFemale representation on editorial boards of leading ophthalmology journals
- Open Access
- 22 February 2024
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 265, 54-60
Comparison of the Biometric Characteristics After Long-term Implantation of Iris-fixated Phakic Intraocular Lens in Explanted and Nonexplanted Groups of Eyes
- 22 February 2024
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 265, 54-60
Open AccessComparison of the Biometric Characteristics After Long-term Implantation of Iris-fixated Phakic Intraocular Lens in Explanted and Nonexplanted Groups of Eyes
- 20 February 2024
- Published by Elsevier in Journal Français d'Ophtalmologie
- Vol. 47 (4) , 104096
Biometric and corneal characteristics in marfan syndrome with ectopia lentis
- 20 February 2024
- Published by Elsevier in Journal Français d'Ophtalmologie
- Vol. 47 (4) , 104096
Biometric and corneal characteristics in marfan syndrome with ectopia lentis
- Open Access
- 3 July 2023
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 17, 1865-1875
Long Term Corneal Flattening After Corneal Crosslinking in Patients with Progressive Keratoconus
Purpose: We evaluate the long-term visual, refractive, and keratometric outcomes after corneal crosslinking (CXL) in patients with progressive keratoconus (KC) and the incidence of an extreme corneal flattening effect. Settings: Oftalmosalud Institute of Eyes, Lima, Perú. Design: Retrospective cohort study. Methods: Forty-five eyes that underwent CXL with epithelial removal between June 2006 and September 2011. Data analysis was performed at preoperative evaluation, 1 year postoperatively, and at least 10 years or more postoperatively. Outcome measures included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and Scheimpflug (Pentacam) analysis. Progression was defined by an increase in steep keratometry (Ks) of 1.5D or greater between 2 examinations. Extreme flattening effect was defined as a decrease in K values equal to or greater than 5 diopters (D). Results: Mean follow-up time was 11 ± 1.07 years (range 10– 13 years). There was a significant improvement in Ks, UCVA, CDVA, and spherical equivalent at the last visit. The overall rate of progression was 2.22% (1/45). Extreme flattening was observed in 15.5% (7/45) of the eyes, and this was associated with a loss of CDVA in 4.44% (2/45) of the eyes. One eye with corneal flattening of 11.5 D lost 7 lines of CDVA and required corneal transplantation. Conclusion: CXL is a safe and effective procedure to stop the progression of KC with a good overall long-term success rate. Extreme corneal flattening may be more common than commonly recognized, and severe corneal flattening associated with a decrease in CDVA may occur.
- 3 July 2023
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 17, 1865-1875
Open AccessLong Term Corneal Flattening After Corneal Crosslinking in Patients with Progressive Keratoconus
Purpose: We evaluate the long-term visual, refractive, and keratometric outcomes after corneal crosslinking (CXL) in patients with progressive keratoconus (KC) and the incidence of an extreme corneal flattening effect. Settings: Oftalmosalud Institute of Eyes, Lima, Perú. Design: Retrospective cohort study. Methods: Forty-five eyes that underwent CXL with epithelial removal between June 2006 and September 2011. Data analysis was performed at preoperative evaluation, 1 year postoperatively, and at least 10 years or more postoperatively. Outcome measures included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and Scheimpflug (Pentacam) analysis. Progression was defined by an increase in steep keratometry (Ks) of 1.5D or greater between 2 examinations. Extreme flattening effect was defined as a decrease in K values equal to or greater than 5 diopters (D). Results: Mean follow-up time was 11 ± 1.07 years (range 10– 13 years). There was a significant improvement in Ks, UCVA, CDVA, and spherical equivalent at the last visit. The overall rate of progression was 2.22% (1/45). Extreme flattening was observed in 15.5% (7/45) of the eyes, and this was associated with a loss of CDVA in 4.44% (2/45) of the eyes. One eye with corneal flattening of 11.5 D lost 7 lines of CDVA and required corneal transplantation. Conclusion: CXL is a safe and effective procedure to stop the progression of KC with a good overall long-term success rate. Extreme corneal flattening may be more common than commonly recognized, and severe corneal flattening associated with a decrease in CDVA may occur.