Natasha Lynn Miles
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Natasha Lynn Miles has a total of 122 co-authors. Here are the top co-authors by number of shared publications:
- Kenneth James Davis
The Pennsylvania State University, University Park, PA, USA
28 shared publications Scott J. Richardson
Department of Meteorology and Atmospheric Science, The Pennsylvania State University, University Park, PA, 16802, USA
27 shared publications- Zachary Robert Barkley
The Pennsylvania State University University Park PA USA
20 shared publications Yunsong Liu
Department of Meteorology and Atmospheric Science, The Pennsylvania State University, University Park, PA, 16802, USA
14 shared publications- Thomas Lauvaux
Climate Impacts on Environment Laboratory (CIEL), Université de Reims-Champagne Ardenne, EMR CNRS 7007 AEROLAB, Reims, France
12 shared publications - Colm Sweeney
National Oceanic and Atmospheric Administration Global Monitoring Laboratory (NOAA/GML), 325 Broadway R/GML, Boulder, CO 80305, USA
10 shared publications
Latest Publications
- Open Access
- 17 October 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-19
Reply on CC1
Water vapor introduces dilution, spectral interference and pressure-broadening effects in greenhouse gas (GHG) measurements using infrared (IR) techniques. Accurate water vapor corrections are therefore required for measurements of ambient air samples that are undried or incompletely dried as is the case for commonly used permeation water exchangers. In this study, we developed a lightweight, low-cost, and portable system for performing water vapor corrections of GHG analyzers in both laboratory and field environments. The system uses a permeable membrane-based moisture exchanger (Permapure, Inc., BE series) to humidify gas from a compressed cylinder with known analyte mole fractions. This humidified stream is mixed with a parallel dry stream from the same cylinder to produce air with controlled water vapor levels. Water-vapor (H2O) concentrations are held constant for a defined interval and then stepped across a range of user-defined levels. Gas flow rates are regulated using mass flow controllers, and a Raspberry Pi-based Linux system automates the sequence of water vapor steps and records measurement data for subsequent analysis. Compared to previously available dew point generators, the system provides substantially improved water vapor stability (approximately 3 ppm H2O). The system was used to characterize water vapor corrections for Aeris MIRA Ultra and Picarro cavity ring-down spectroscopy (CRDS) analyzers. The two tested Aeris MIRA Ultra analyzers exhibited quadratic relationships for methane (CH4), with distinct behaviors observed between low- and high-H2O regimes, with errors of up to 30 ppb CH4 at 3 % H2O if uncorrected. However, these two tested Aeris MIRA Ultra analyzers did not show clear dependence on water vapor for ethane (C2H6). Across the investigated humidity range, all three tested Picarro analyzers showed a nearly linear dependence for carbon dioxide (CO2), and both analyzers tested for CH4 exhibited a similar near-linear response. For carbon monoxide (CO), however, two of the three tested analyzers displayed a quadratic humidity dependence, and one did not show any dependence on water vapor. For the Picarro analyzers, the errors if uncorrected for water vapor response were as large as 0.25 ppm CO2, 2.0 ppb CH4, and 12 ppb CO, all at 1.7 % H2O. After applying the derived analyzer-specific water vapor correction functions to all datasets, the corrected CH4, CO2, and CO measurements from Aeris MIRA Ultra and Picarro analyzers were well within the WMO/GAW inter-laboratory compatibility goals. These results demonstrate that the system provides a practical and reliable approach for conducting water vapor corrections for GHG analyzers in laboratory and field applications.
- 17 October 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-19
Open AccessReply on CC1
Water vapor introduces dilution, spectral interference and pressure-broadening effects in greenhouse gas (GHG) measurements using infrared (IR) techniques. Accurate water vapor corrections are therefore required for measurements of ambient air samples that are undried or incompletely dried as is the case for commonly used permeation water exchangers. In this study, we developed a lightweight, low-cost, and portable system for performing water vapor corrections of GHG analyzers in both laboratory and field environments. The system uses a permeable membrane-based moisture exchanger (Permapure, Inc., BE series) to humidify gas from a compressed cylinder with known analyte mole fractions. This humidified stream is mixed with a parallel dry stream from the same cylinder to produce air with controlled water vapor levels. Water-vapor (H2O) concentrations are held constant for a defined interval and then stepped across a range of user-defined levels. Gas flow rates are regulated using mass flow controllers, and a Raspberry Pi-based Linux system automates the sequence of water vapor steps and records measurement data for subsequent analysis. Compared to previously available dew point generators, the system provides substantially improved water vapor stability (approximately 3 ppm H2O). The system was used to characterize water vapor corrections for Aeris MIRA Ultra and Picarro cavity ring-down spectroscopy (CRDS) analyzers. The two tested Aeris MIRA Ultra analyzers exhibited quadratic relationships for methane (CH4), with distinct behaviors observed between low- and high-H2O regimes, with errors of up to 30 ppb CH4 at 3 % H2O if uncorrected. However, these two tested Aeris MIRA Ultra analyzers did not show clear dependence on water vapor for ethane (C2H6). Across the investigated humidity range, all three tested Picarro analyzers showed a nearly linear dependence for carbon dioxide (CO2), and both analyzers tested for CH4 exhibited a similar near-linear response. For carbon monoxide (CO), however, two of the three tested analyzers displayed a quadratic humidity dependence, and one did not show any dependence on water vapor. For the Picarro analyzers, the errors if uncorrected for water vapor response were as large as 0.25 ppm CO2, 2.0 ppb CH4, and 12 ppb CO, all at 1.7 % H2O. After applying the derived analyzer-specific water vapor correction functions to all datasets, the corrected CH4, CO2, and CO measurements from Aeris MIRA Ultra and Picarro analyzers were well within the WMO/GAW inter-laboratory compatibility goals. These results demonstrate that the system provides a practical and reliable approach for conducting water vapor corrections for GHG analyzers in laboratory and field applications.
- Open Access
- 17 October 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-19
Reply on RC2
Water vapor introduces dilution, spectral interference and pressure-broadening effects in greenhouse gas (GHG) measurements using infrared (IR) techniques. Accurate water vapor corrections are therefore required for measurements of ambient air samples that are undried or incompletely dried as is the case for commonly used permeation water exchangers. In this study, we developed a lightweight, low-cost, and portable system for performing water vapor corrections of GHG analyzers in both laboratory and field environments. The system uses a permeable membrane-based moisture exchanger (Permapure, Inc., BE series) to humidify gas from a compressed cylinder with known analyte mole fractions. This humidified stream is mixed with a parallel dry stream from the same cylinder to produce air with controlled water vapor levels. Water-vapor (H2O) concentrations are held constant for a defined interval and then stepped across a range of user-defined levels. Gas flow rates are regulated using mass flow controllers, and a Raspberry Pi-based Linux system automates the sequence of water vapor steps and records measurement data for subsequent analysis. Compared to previously available dew point generators, the system provides substantially improved water vapor stability (approximately 3 ppm H2O). The system was used to characterize water vapor corrections for Aeris MIRA Ultra and Picarro cavity ring-down spectroscopy (CRDS) analyzers. The two tested Aeris MIRA Ultra analyzers exhibited quadratic relationships for methane (CH4), with distinct behaviors observed between low- and high-H2O regimes, with errors of up to 30 ppb CH4 at 3 % H2O if uncorrected. However, these two tested Aeris MIRA Ultra analyzers did not show clear dependence on water vapor for ethane (C2H6). Across the investigated humidity range, all three tested Picarro analyzers showed a nearly linear dependence for carbon dioxide (CO2), and both analyzers tested for CH4 exhibited a similar near-linear response. For carbon monoxide (CO), however, two of the three tested analyzers displayed a quadratic humidity dependence, and one did not show any dependence on water vapor. For the Picarro analyzers, the errors if uncorrected for water vapor response were as large as 0.25 ppm CO2, 2.0 ppb CH4, and 12 ppb CO, all at 1.7 % H2O. After applying the derived analyzer-specific water vapor correction functions to all datasets, the corrected CH4, CO2, and CO measurements from Aeris MIRA Ultra and Picarro analyzers were well within the WMO/GAW inter-laboratory compatibility goals. These results demonstrate that the system provides a practical and reliable approach for conducting water vapor corrections for GHG analyzers in laboratory and field applications.
- 17 October 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-19
Open AccessReply on RC2
Water vapor introduces dilution, spectral interference and pressure-broadening effects in greenhouse gas (GHG) measurements using infrared (IR) techniques. Accurate water vapor corrections are therefore required for measurements of ambient air samples that are undried or incompletely dried as is the case for commonly used permeation water exchangers. In this study, we developed a lightweight, low-cost, and portable system for performing water vapor corrections of GHG analyzers in both laboratory and field environments. The system uses a permeable membrane-based moisture exchanger (Permapure, Inc., BE series) to humidify gas from a compressed cylinder with known analyte mole fractions. This humidified stream is mixed with a parallel dry stream from the same cylinder to produce air with controlled water vapor levels. Water-vapor (H2O) concentrations are held constant for a defined interval and then stepped across a range of user-defined levels. Gas flow rates are regulated using mass flow controllers, and a Raspberry Pi-based Linux system automates the sequence of water vapor steps and records measurement data for subsequent analysis. Compared to previously available dew point generators, the system provides substantially improved water vapor stability (approximately 3 ppm H2O). The system was used to characterize water vapor corrections for Aeris MIRA Ultra and Picarro cavity ring-down spectroscopy (CRDS) analyzers. The two tested Aeris MIRA Ultra analyzers exhibited quadratic relationships for methane (CH4), with distinct behaviors observed between low- and high-H2O regimes, with errors of up to 30 ppb CH4 at 3 % H2O if uncorrected. However, these two tested Aeris MIRA Ultra analyzers did not show clear dependence on water vapor for ethane (C2H6). Across the investigated humidity range, all three tested Picarro analyzers showed a nearly linear dependence for carbon dioxide (CO2), and both analyzers tested for CH4 exhibited a similar near-linear response. For carbon monoxide (CO), however, two of the three tested analyzers displayed a quadratic humidity dependence, and one did not show any dependence on water vapor. For the Picarro analyzers, the errors if uncorrected for water vapor response were as large as 0.25 ppm CO2, 2.0 ppb CH4, and 12 ppb CO, all at 1.7 % H2O. After applying the derived analyzer-specific water vapor correction functions to all datasets, the corrected CH4, CO2, and CO measurements from Aeris MIRA Ultra and Picarro analyzers were well within the WMO/GAW inter-laboratory compatibility goals. These results demonstrate that the system provides a practical and reliable approach for conducting water vapor corrections for GHG analyzers in laboratory and field applications.
- Open Access
- 17 October 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-19
Reply on RC1
Water vapor introduces dilution, spectral interference and pressure-broadening effects in greenhouse gas (GHG) measurements using infrared (IR) techniques. Accurate water vapor corrections are therefore required for measurements of ambient air samples that are undried or incompletely dried as is the case for commonly used permeation water exchangers. In this study, we developed a lightweight, low-cost, and portable system for performing water vapor corrections of GHG analyzers in both laboratory and field environments. The system uses a permeable membrane-based moisture exchanger (Permapure, Inc., BE series) to humidify gas from a compressed cylinder with known analyte mole fractions. This humidified stream is mixed with a parallel dry stream from the same cylinder to produce air with controlled water vapor levels. Water-vapor (H2O) concentrations are held constant for a defined interval and then stepped across a range of user-defined levels. Gas flow rates are regulated using mass flow controllers, and a Raspberry Pi-based Linux system automates the sequence of water vapor steps and records measurement data for subsequent analysis. Compared to previously available dew point generators, the system provides substantially improved water vapor stability (approximately 3 ppm H2O). The system was used to characterize water vapor corrections for Aeris MIRA Ultra and Picarro cavity ring-down spectroscopy (CRDS) analyzers. The two tested Aeris MIRA Ultra analyzers exhibited quadratic relationships for methane (CH4), with distinct behaviors observed between low- and high-H2O regimes, with errors of up to 30 ppb CH4 at 3 % H2O if uncorrected. However, these two tested Aeris MIRA Ultra analyzers did not show clear dependence on water vapor for ethane (C2H6). Across the investigated humidity range, all three tested Picarro analyzers showed a nearly linear dependence for carbon dioxide (CO2), and both analyzers tested for CH4 exhibited a similar near-linear response. For carbon monoxide (CO), however, two of the three tested analyzers displayed a quadratic humidity dependence, and one did not show any dependence on water vapor. For the Picarro analyzers, the errors if uncorrected for water vapor response were as large as 0.25 ppm CO2, 2.0 ppb CH4, and 12 ppb CO, all at 1.7 % H2O. After applying the derived analyzer-specific water vapor correction functions to all datasets, the corrected CH4, CO2, and CO measurements from Aeris MIRA Ultra and Picarro analyzers were well within the WMO/GAW inter-laboratory compatibility goals. These results demonstrate that the system provides a practical and reliable approach for conducting water vapor corrections for GHG analyzers in laboratory and field applications.
- 17 October 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-19
Open AccessReply on RC1
Water vapor introduces dilution, spectral interference and pressure-broadening effects in greenhouse gas (GHG) measurements using infrared (IR) techniques. Accurate water vapor corrections are therefore required for measurements of ambient air samples that are undried or incompletely dried as is the case for commonly used permeation water exchangers. In this study, we developed a lightweight, low-cost, and portable system for performing water vapor corrections of GHG analyzers in both laboratory and field environments. The system uses a permeable membrane-based moisture exchanger (Permapure, Inc., BE series) to humidify gas from a compressed cylinder with known analyte mole fractions. This humidified stream is mixed with a parallel dry stream from the same cylinder to produce air with controlled water vapor levels. Water-vapor (H2O) concentrations are held constant for a defined interval and then stepped across a range of user-defined levels. Gas flow rates are regulated using mass flow controllers, and a Raspberry Pi-based Linux system automates the sequence of water vapor steps and records measurement data for subsequent analysis. Compared to previously available dew point generators, the system provides substantially improved water vapor stability (approximately 3 ppm H2O). The system was used to characterize water vapor corrections for Aeris MIRA Ultra and Picarro cavity ring-down spectroscopy (CRDS) analyzers. The two tested Aeris MIRA Ultra analyzers exhibited quadratic relationships for methane (CH4), with distinct behaviors observed between low- and high-H2O regimes, with errors of up to 30 ppb CH4 at 3 % H2O if uncorrected. However, these two tested Aeris MIRA Ultra analyzers did not show clear dependence on water vapor for ethane (C2H6). Across the investigated humidity range, all three tested Picarro analyzers showed a nearly linear dependence for carbon dioxide (CO2), and both analyzers tested for CH4 exhibited a similar near-linear response. For carbon monoxide (CO), however, two of the three tested analyzers displayed a quadratic humidity dependence, and one did not show any dependence on water vapor. For the Picarro analyzers, the errors if uncorrected for water vapor response were as large as 0.25 ppm CO2, 2.0 ppb CH4, and 12 ppb CO, all at 1.7 % H2O. After applying the derived analyzer-specific water vapor correction functions to all datasets, the corrected CH4, CO2, and CO measurements from Aeris MIRA Ultra and Picarro analyzers were well within the WMO/GAW inter-laboratory compatibility goals. These results demonstrate that the system provides a practical and reliable approach for conducting water vapor corrections for GHG analyzers in laboratory and field applications.
- Open Access
- 20 August 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-19
Comment on egusphere-2026-3732
Water vapor introduces dilution, spectral interference and pressure-broadening effects in greenhouse gas (GHG) measurements using infrared (IR) techniques. Accurate water vapor corrections are therefore required for measurements of ambient air samples that are undried or incompletely dried as is the case for commonly used permeation water exchangers. In this study, we developed a lightweight, low-cost, and portable system for performing water vapor corrections of GHG analyzers in both laboratory and field environments. The system uses a permeable membrane-based moisture exchanger (Permapure, Inc., BE series) to humidify gas from a compressed cylinder with known analyte mole fractions. This humidified stream is mixed with a parallel dry stream from the same cylinder to produce air with controlled water vapor levels. Water-vapor (H2O) concentrations are held constant for a defined interval and then stepped across a range of user-defined levels. Gas flow rates are regulated using mass flow controllers, and a Raspberry Pi-based Linux system automates the sequence of water vapor steps and records measurement data for subsequent analysis. Compared to previously available dew point generators, the system provides substantially improved water vapor stability (approximately 3 ppm H2O). The system was used to characterize water vapor corrections for Aeris MIRA Ultra and Picarro cavity ring-down spectroscopy (CRDS) analyzers. The two tested Aeris MIRA Ultra analyzers exhibited quadratic relationships for methane (CH4), with distinct behaviors observed between low- and high-H2O regimes, with errors of up to 30 ppb CH4 at 3 % H2O if uncorrected. However, these two tested Aeris MIRA Ultra analyzers did not show clear dependence on water vapor for ethane (C2H6). Across the investigated humidity range, all three tested Picarro analyzers showed a nearly linear dependence for carbon dioxide (CO2), and both analyzers tested for CH4 exhibited a similar near-linear response. For carbon monoxide (CO), however, two of the three tested analyzers displayed a quadratic humidity dependence, and one did not show any dependence on water vapor. For the Picarro analyzers, the errors if uncorrected for water vapor response were as large as 0.25 ppm CO2, 2.0 ppb CH4, and 12 ppb CO, all at 1.7 % H2O. After applying the derived analyzer-specific water vapor correction functions to all datasets, the corrected CH4, CO2, and CO measurements from Aeris MIRA Ultra and Picarro analyzers were well within the WMO/GAW inter-laboratory compatibility goals. These results demonstrate that the system provides a practical and reliable approach for conducting water vapor corrections for GHG analyzers in laboratory and field applications.
- 20 August 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-19
Open AccessComment on egusphere-2026-3732
Water vapor introduces dilution, spectral interference and pressure-broadening effects in greenhouse gas (GHG) measurements using infrared (IR) techniques. Accurate water vapor corrections are therefore required for measurements of ambient air samples that are undried or incompletely dried as is the case for commonly used permeation water exchangers. In this study, we developed a lightweight, low-cost, and portable system for performing water vapor corrections of GHG analyzers in both laboratory and field environments. The system uses a permeable membrane-based moisture exchanger (Permapure, Inc., BE series) to humidify gas from a compressed cylinder with known analyte mole fractions. This humidified stream is mixed with a parallel dry stream from the same cylinder to produce air with controlled water vapor levels. Water-vapor (H2O) concentrations are held constant for a defined interval and then stepped across a range of user-defined levels. Gas flow rates are regulated using mass flow controllers, and a Raspberry Pi-based Linux system automates the sequence of water vapor steps and records measurement data for subsequent analysis. Compared to previously available dew point generators, the system provides substantially improved water vapor stability (approximately 3 ppm H2O). The system was used to characterize water vapor corrections for Aeris MIRA Ultra and Picarro cavity ring-down spectroscopy (CRDS) analyzers. The two tested Aeris MIRA Ultra analyzers exhibited quadratic relationships for methane (CH4), with distinct behaviors observed between low- and high-H2O regimes, with errors of up to 30 ppb CH4 at 3 % H2O if uncorrected. However, these two tested Aeris MIRA Ultra analyzers did not show clear dependence on water vapor for ethane (C2H6). Across the investigated humidity range, all three tested Picarro analyzers showed a nearly linear dependence for carbon dioxide (CO2), and both analyzers tested for CH4 exhibited a similar near-linear response. For carbon monoxide (CO), however, two of the three tested analyzers displayed a quadratic humidity dependence, and one did not show any dependence on water vapor. For the Picarro analyzers, the errors if uncorrected for water vapor response were as large as 0.25 ppm CO2, 2.0 ppb CH4, and 12 ppb CO, all at 1.7 % H2O. After applying the derived analyzer-specific water vapor correction functions to all datasets, the corrected CH4, CO2, and CO measurements from Aeris MIRA Ultra and Picarro analyzers were well within the WMO/GAW inter-laboratory compatibility goals. These results demonstrate that the system provides a practical and reliable approach for conducting water vapor corrections for GHG analyzers in laboratory and field applications.
- Open Access
- 7 August 2026
- Published by Copernicus GmbH
- p. 1-19
Comment on egusphere-2026-3732
Water vapor introduces dilution, spectral interference and pressure-broadening effects in greenhouse gas (GHG) measurements using infrared (IR) techniques. Accurate water vapor corrections are therefore required for measurements of ambient air samples that are undried or incompletely dried as is the case for commonly used permeation water exchangers. In this study, we developed a lightweight, low-cost, and portable system for performing water vapor corrections of GHG analyzers in both laboratory and field environments. The system uses a permeable membrane-based moisture exchanger (Permapure, Inc., BE series) to humidify gas from a compressed cylinder with known analyte mole fractions. This humidified stream is mixed with a parallel dry stream from the same cylinder to produce air with controlled water vapor levels. Water-vapor (H2O) concentrations are held constant for a defined interval and then stepped across a range of user-defined levels. Gas flow rates are regulated using mass flow controllers, and a Raspberry Pi-based Linux system automates the sequence of water vapor steps and records measurement data for subsequent analysis. Compared to previously available dew point generators, the system provides substantially improved water vapor stability (approximately 3 ppm H2O). The system was used to characterize water vapor corrections for Aeris MIRA Ultra and Picarro cavity ring-down spectroscopy (CRDS) analyzers. The two tested Aeris MIRA Ultra analyzers exhibited quadratic relationships for methane (CH4), with distinct behaviors observed between low- and high-H2O regimes, with errors of up to 30 ppb CH4 at 3 % H2O if uncorrected. However, these two tested Aeris MIRA Ultra analyzers did not show clear dependence on water vapor for ethane (C2H6). Across the investigated humidity range, all three tested Picarro analyzers showed a nearly linear dependence for carbon dioxide (CO2), and both analyzers tested for CH4 exhibited a similar near-linear response. For carbon monoxide (CO), however, two of the three tested analyzers displayed a quadratic humidity dependence, and one did not show any dependence on water vapor. For the Picarro analyzers, the errors if uncorrected for water vapor response were as large as 0.25 ppm CO2, 2.0 ppb CH4, and 12 ppb CO, all at 1.7 % H2O. After applying the derived analyzer-specific water vapor correction functions to all datasets, the corrected CH4, CO2, and CO measurements from Aeris MIRA Ultra and Picarro analyzers were well within the WMO/GAW inter-laboratory compatibility goals. These results demonstrate that the system provides a practical and reliable approach for conducting water vapor corrections for GHG analyzers in laboratory and field applications.
- 7 August 2026
- Published by Copernicus GmbH
- p. 1-19
Open AccessComment on egusphere-2026-3732
Water vapor introduces dilution, spectral interference and pressure-broadening effects in greenhouse gas (GHG) measurements using infrared (IR) techniques. Accurate water vapor corrections are therefore required for measurements of ambient air samples that are undried or incompletely dried as is the case for commonly used permeation water exchangers. In this study, we developed a lightweight, low-cost, and portable system for performing water vapor corrections of GHG analyzers in both laboratory and field environments. The system uses a permeable membrane-based moisture exchanger (Permapure, Inc., BE series) to humidify gas from a compressed cylinder with known analyte mole fractions. This humidified stream is mixed with a parallel dry stream from the same cylinder to produce air with controlled water vapor levels. Water-vapor (H2O) concentrations are held constant for a defined interval and then stepped across a range of user-defined levels. Gas flow rates are regulated using mass flow controllers, and a Raspberry Pi-based Linux system automates the sequence of water vapor steps and records measurement data for subsequent analysis. Compared to previously available dew point generators, the system provides substantially improved water vapor stability (approximately 3 ppm H2O). The system was used to characterize water vapor corrections for Aeris MIRA Ultra and Picarro cavity ring-down spectroscopy (CRDS) analyzers. The two tested Aeris MIRA Ultra analyzers exhibited quadratic relationships for methane (CH4), with distinct behaviors observed between low- and high-H2O regimes, with errors of up to 30 ppb CH4 at 3 % H2O if uncorrected. However, these two tested Aeris MIRA Ultra analyzers did not show clear dependence on water vapor for ethane (C2H6). Across the investigated humidity range, all three tested Picarro analyzers showed a nearly linear dependence for carbon dioxide (CO2), and both analyzers tested for CH4 exhibited a similar near-linear response. For carbon monoxide (CO), however, two of the three tested analyzers displayed a quadratic humidity dependence, and one did not show any dependence on water vapor. For the Picarro analyzers, the errors if uncorrected for water vapor response were as large as 0.25 ppm CO2, 2.0 ppb CH4, and 12 ppb CO, all at 1.7 % H2O. After applying the derived analyzer-specific water vapor correction functions to all datasets, the corrected CH4, CO2, and CO measurements from Aeris MIRA Ultra and Picarro analyzers were well within the WMO/GAW inter-laboratory compatibility goals. These results demonstrate that the system provides a practical and reliable approach for conducting water vapor corrections for GHG analyzers in laboratory and field applications.
- Open Access
- 7 August 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-19
Comment on egusphere-2026-3732
Water vapor introduces dilution, spectral interference and pressure-broadening effects in greenhouse gas (GHG) measurements using infrared (IR) techniques. Accurate water vapor corrections are therefore required for measurements of ambient air samples that are undried or incompletely dried as is the case for commonly used permeation water exchangers. In this study, we developed a lightweight, low-cost, and portable system for performing water vapor corrections of GHG analyzers in both laboratory and field environments. The system uses a permeable membrane-based moisture exchanger (Permapure, Inc., BE series) to humidify gas from a compressed cylinder with known analyte mole fractions. This humidified stream is mixed with a parallel dry stream from the same cylinder to produce air with controlled water vapor levels. Water-vapor (H2O) concentrations are held constant for a defined interval and then stepped across a range of user-defined levels. Gas flow rates are regulated using mass flow controllers, and a Raspberry Pi-based Linux system automates the sequence of water vapor steps and records measurement data for subsequent analysis. Compared to previously available dew point generators, the system provides substantially improved water vapor stability (approximately 3 ppm H2O). The system was used to characterize water vapor corrections for Aeris MIRA Ultra and Picarro cavity ring-down spectroscopy (CRDS) analyzers. The two tested Aeris MIRA Ultra analyzers exhibited quadratic relationships for methane (CH4), with distinct behaviors observed between low- and high-H2O regimes, with errors of up to 30 ppb CH4 at 3 % H2O if uncorrected. However, these two tested Aeris MIRA Ultra analyzers did not show clear dependence on water vapor for ethane (C2H6). Across the investigated humidity range, all three tested Picarro analyzers showed a nearly linear dependence for carbon dioxide (CO2), and both analyzers tested for CH4 exhibited a similar near-linear response. For carbon monoxide (CO), however, two of the three tested analyzers displayed a quadratic humidity dependence, and one did not show any dependence on water vapor. For the Picarro analyzers, the errors if uncorrected for water vapor response were as large as 0.25 ppm CO2, 2.0 ppb CH4, and 12 ppb CO, all at 1.7 % H2O. After applying the derived analyzer-specific water vapor correction functions to all datasets, the corrected CH4, CO2, and CO measurements from Aeris MIRA Ultra and Picarro analyzers were well within the WMO/GAW inter-laboratory compatibility goals. These results demonstrate that the system provides a practical and reliable approach for conducting water vapor corrections for GHG analyzers in laboratory and field applications.
- 7 August 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-19
Open AccessComment on egusphere-2026-3732
Water vapor introduces dilution, spectral interference and pressure-broadening effects in greenhouse gas (GHG) measurements using infrared (IR) techniques. Accurate water vapor corrections are therefore required for measurements of ambient air samples that are undried or incompletely dried as is the case for commonly used permeation water exchangers. In this study, we developed a lightweight, low-cost, and portable system for performing water vapor corrections of GHG analyzers in both laboratory and field environments. The system uses a permeable membrane-based moisture exchanger (Permapure, Inc., BE series) to humidify gas from a compressed cylinder with known analyte mole fractions. This humidified stream is mixed with a parallel dry stream from the same cylinder to produce air with controlled water vapor levels. Water-vapor (H2O) concentrations are held constant for a defined interval and then stepped across a range of user-defined levels. Gas flow rates are regulated using mass flow controllers, and a Raspberry Pi-based Linux system automates the sequence of water vapor steps and records measurement data for subsequent analysis. Compared to previously available dew point generators, the system provides substantially improved water vapor stability (approximately 3 ppm H2O). The system was used to characterize water vapor corrections for Aeris MIRA Ultra and Picarro cavity ring-down spectroscopy (CRDS) analyzers. The two tested Aeris MIRA Ultra analyzers exhibited quadratic relationships for methane (CH4), with distinct behaviors observed between low- and high-H2O regimes, with errors of up to 30 ppb CH4 at 3 % H2O if uncorrected. However, these two tested Aeris MIRA Ultra analyzers did not show clear dependence on water vapor for ethane (C2H6). Across the investigated humidity range, all three tested Picarro analyzers showed a nearly linear dependence for carbon dioxide (CO2), and both analyzers tested for CH4 exhibited a similar near-linear response. For carbon monoxide (CO), however, two of the three tested analyzers displayed a quadratic humidity dependence, and one did not show any dependence on water vapor. For the Picarro analyzers, the errors if uncorrected for water vapor response were as large as 0.25 ppm CO2, 2.0 ppb CH4, and 12 ppb CO, all at 1.7 % H2O. After applying the derived analyzer-specific water vapor correction functions to all datasets, the corrected CH4, CO2, and CO measurements from Aeris MIRA Ultra and Picarro analyzers were well within the WMO/GAW inter-laboratory compatibility goals. These results demonstrate that the system provides a practical and reliable approach for conducting water vapor corrections for GHG analyzers in laboratory and field applications.
- Open Access
- 31 July 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-19
Comment on egusphere-2026-3732
Water vapor introduces dilution, spectral interference and pressure-broadening effects in greenhouse gas (GHG) measurements using infrared (IR) techniques. Accurate water vapor corrections are therefore required for measurements of ambient air samples that are undried or incompletely dried as is the case for commonly used permeation water exchangers. In this study, we developed a lightweight, low-cost, and portable system for performing water vapor corrections of GHG analyzers in both laboratory and field environments. The system uses a permeable membrane-based moisture exchanger (Permapure, Inc., BE series) to humidify gas from a compressed cylinder with known analyte mole fractions. This humidified stream is mixed with a parallel dry stream from the same cylinder to produce air with controlled water vapor levels. Water-vapor (H2O) concentrations are held constant for a defined interval and then stepped across a range of user-defined levels. Gas flow rates are regulated using mass flow controllers, and a Raspberry Pi-based Linux system automates the sequence of water vapor steps and records measurement data for subsequent analysis. Compared to previously available dew point generators, the system provides substantially improved water vapor stability (approximately 3 ppm H2O). The system was used to characterize water vapor corrections for Aeris MIRA Ultra and Picarro cavity ring-down spectroscopy (CRDS) analyzers. The two tested Aeris MIRA Ultra analyzers exhibited quadratic relationships for methane (CH4), with distinct behaviors observed between low- and high-H2O regimes, with errors of up to 30 ppb CH4 at 3 % H2O if uncorrected. However, these two tested Aeris MIRA Ultra analyzers did not show clear dependence on water vapor for ethane (C2H6). Across the investigated humidity range, all three tested Picarro analyzers showed a nearly linear dependence for carbon dioxide (CO2), and both analyzers tested for CH4 exhibited a similar near-linear response. For carbon monoxide (CO), however, two of the three tested analyzers displayed a quadratic humidity dependence, and one did not show any dependence on water vapor. For the Picarro analyzers, the errors if uncorrected for water vapor response were as large as 0.25 ppm CO2, 2.0 ppb CH4, and 12 ppb CO, all at 1.7 % H2O. After applying the derived analyzer-specific water vapor correction functions to all datasets, the corrected CH4, CO2, and CO measurements from Aeris MIRA Ultra and Picarro analyzers were well within the WMO/GAW inter-laboratory compatibility goals. These results demonstrate that the system provides a practical and reliable approach for conducting water vapor corrections for GHG analyzers in laboratory and field applications.
- 31 July 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-19
Open AccessComment on egusphere-2026-3732
Water vapor introduces dilution, spectral interference and pressure-broadening effects in greenhouse gas (GHG) measurements using infrared (IR) techniques. Accurate water vapor corrections are therefore required for measurements of ambient air samples that are undried or incompletely dried as is the case for commonly used permeation water exchangers. In this study, we developed a lightweight, low-cost, and portable system for performing water vapor corrections of GHG analyzers in both laboratory and field environments. The system uses a permeable membrane-based moisture exchanger (Permapure, Inc., BE series) to humidify gas from a compressed cylinder with known analyte mole fractions. This humidified stream is mixed with a parallel dry stream from the same cylinder to produce air with controlled water vapor levels. Water-vapor (H2O) concentrations are held constant for a defined interval and then stepped across a range of user-defined levels. Gas flow rates are regulated using mass flow controllers, and a Raspberry Pi-based Linux system automates the sequence of water vapor steps and records measurement data for subsequent analysis. Compared to previously available dew point generators, the system provides substantially improved water vapor stability (approximately 3 ppm H2O). The system was used to characterize water vapor corrections for Aeris MIRA Ultra and Picarro cavity ring-down spectroscopy (CRDS) analyzers. The two tested Aeris MIRA Ultra analyzers exhibited quadratic relationships for methane (CH4), with distinct behaviors observed between low- and high-H2O regimes, with errors of up to 30 ppb CH4 at 3 % H2O if uncorrected. However, these two tested Aeris MIRA Ultra analyzers did not show clear dependence on water vapor for ethane (C2H6). Across the investigated humidity range, all three tested Picarro analyzers showed a nearly linear dependence for carbon dioxide (CO2), and both analyzers tested for CH4 exhibited a similar near-linear response. For carbon monoxide (CO), however, two of the three tested analyzers displayed a quadratic humidity dependence, and one did not show any dependence on water vapor. For the Picarro analyzers, the errors if uncorrected for water vapor response were as large as 0.25 ppm CO2, 2.0 ppb CH4, and 12 ppb CO, all at 1.7 % H2O. After applying the derived analyzer-specific water vapor correction functions to all datasets, the corrected CH4, CO2, and CO measurements from Aeris MIRA Ultra and Picarro analyzers were well within the WMO/GAW inter-laboratory compatibility goals. These results demonstrate that the system provides a practical and reliable approach for conducting water vapor corrections for GHG analyzers in laboratory and field applications.
- Open Access
- 14 July 2026
- Published by Copernicus GmbH
Supplementary material to "Portable system for characterizing greenhouse gas analyzers for sensitivity to water vapor"
- 14 July 2026
- Published by Copernicus GmbH
Open AccessSupplementary material to "Portable system for characterizing greenhouse gas analyzers for sensitivity to water vapor"
- Open Access
- 14 July 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-19
Portable system for characterizing greenhouse gas analyzers for sensitivity to water vapor
Water vapor introduces dilution, spectral interference and pressure-broadening effects in greenhouse gas (GHG) measurements using infrared (IR) techniques. Accurate water vapor corrections are therefore required for measurements of ambient air samples that are undried or incompletely dried as is the case for commonly used permeation water exchangers. In this study, we developed a lightweight, low-cost, and portable system for performing water vapor corrections of GHG analyzers in both laboratory and field environments. The system uses a permeable membrane-based moisture exchanger (Permapure, Inc., BE series) to humidify gas from a compressed cylinder with known analyte mole fractions. This humidified stream is mixed with a parallel dry stream from the same cylinder to produce air with controlled water vapor levels. Water-vapor (H2O) concentrations are held constant for a defined interval and then stepped across a range of user-defined levels. Gas flow rates are regulated using mass flow controllers, and a Raspberry Pi-based Linux system automates the sequence of water vapor steps and records measurement data for subsequent analysis. Compared to previously available dew point generators, the system provides substantially improved water vapor stability (approximately 3 ppm H2O). The system was used to characterize water vapor corrections for Aeris MIRA Ultra and Picarro cavity ring-down spectroscopy (CRDS) analyzers. The two tested Aeris MIRA Ultra analyzers exhibited quadratic relationships for methane (CH4), with distinct behaviors observed between low- and high-H2O regimes, with errors of up to 30 ppb CH4 at 3 % H2O if uncorrected. However, these two tested Aeris MIRA Ultra analyzers did not show clear dependence on water vapor for ethane (C2H6). Across the investigated humidity range, all three tested Picarro analyzers showed a nearly linear dependence for carbon dioxide (CO2), and both analyzers tested for CH4 exhibited a similar near-linear response. For carbon monoxide (CO), however, two of the three tested analyzers displayed a quadratic humidity dependence, and one did not show any dependence on water vapor. For the Picarro analyzers, the errors if uncorrected for water vapor response were as large as 0.25 ppm CO2, 2.0 ppb CH4, and 12 ppb CO, all at 1.7 % H2O. After applying the derived analyzer-specific water vapor correction functions to all datasets, the corrected CH4, CO2, and CO measurements from Aeris MIRA Ultra and Picarro analyzers were well within the WMO/GAW inter-laboratory compatibility goals. These results demonstrate that the system provides a practical and reliable approach for conducting water vapor corrections for GHG analyzers in laboratory and field applications.
- 14 July 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-19
Open AccessPortable system for characterizing greenhouse gas analyzers for sensitivity to water vapor
Water vapor introduces dilution, spectral interference and pressure-broadening effects in greenhouse gas (GHG) measurements using infrared (IR) techniques. Accurate water vapor corrections are therefore required for measurements of ambient air samples that are undried or incompletely dried as is the case for commonly used permeation water exchangers. In this study, we developed a lightweight, low-cost, and portable system for performing water vapor corrections of GHG analyzers in both laboratory and field environments. The system uses a permeable membrane-based moisture exchanger (Permapure, Inc., BE series) to humidify gas from a compressed cylinder with known analyte mole fractions. This humidified stream is mixed with a parallel dry stream from the same cylinder to produce air with controlled water vapor levels. Water-vapor (H2O) concentrations are held constant for a defined interval and then stepped across a range of user-defined levels. Gas flow rates are regulated using mass flow controllers, and a Raspberry Pi-based Linux system automates the sequence of water vapor steps and records measurement data for subsequent analysis. Compared to previously available dew point generators, the system provides substantially improved water vapor stability (approximately 3 ppm H2O). The system was used to characterize water vapor corrections for Aeris MIRA Ultra and Picarro cavity ring-down spectroscopy (CRDS) analyzers. The two tested Aeris MIRA Ultra analyzers exhibited quadratic relationships for methane (CH4), with distinct behaviors observed between low- and high-H2O regimes, with errors of up to 30 ppb CH4 at 3 % H2O if uncorrected. However, these two tested Aeris MIRA Ultra analyzers did not show clear dependence on water vapor for ethane (C2H6). Across the investigated humidity range, all three tested Picarro analyzers showed a nearly linear dependence for carbon dioxide (CO2), and both analyzers tested for CH4 exhibited a similar near-linear response. For carbon monoxide (CO), however, two of the three tested analyzers displayed a quadratic humidity dependence, and one did not show any dependence on water vapor. For the Picarro analyzers, the errors if uncorrected for water vapor response were as large as 0.25 ppm CO2, 2.0 ppb CH4, and 12 ppb CO, all at 1.7 % H2O. After applying the derived analyzer-specific water vapor correction functions to all datasets, the corrected CH4, CO2, and CO measurements from Aeris MIRA Ultra and Picarro analyzers were well within the WMO/GAW inter-laboratory compatibility goals. These results demonstrate that the system provides a practical and reliable approach for conducting water vapor corrections for GHG analyzers in laboratory and field applications.
- Open Access
- 10 February 2026
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 19 (3) , 965-981
Laboratory and field assessment of mid-infrared absorption (MIRA) instrument performance for methane and ethane dry mole fractions
Concurrent measurements of methane (CH4) and ethane (C2H6) can be used to identify and separate methane sources, as ethane is present in thermogenic sources (e.g., oil and natural gas) but not in biogenic sources (e.g., agriculture). In this study, we evaluated the performance of multiple Aeris MIRA Ultra instruments (Versions 1 and 2) through controlled laboratory tests and tower-based deployments under field conditions. The systems were modified with an external pump, flow control, a Nafion dryer, and a custom-built auxiliary box to automate the system and transmit near real-time data. We determined the best calibration approach for our application, given practical limitations, to be a full calibration cycle (with ambient and high calibration cylinders) about once per day and an ambient calibration cylinder sampled hourly. Measurement uncertainty was assessed, including the uncertainty due to instrument noise as a function of calibration frequency, uncertainty in the water vapor correction, and cylinder assignment uncertainty. Instrument noise was the dominant source of uncertainty for C2H6, while the water vapor correction dominated the CH4 uncertainty. For Version 2 systems with hourly calibrations and a Nafion dryer with counterflow, the mean total uncertainty, including both systematic errors and noise, of hourly averages was 0.8–3.0 ppb CH4 and 0.35–0.37 ppb C2H6. Laboratory intercomparisons showed network compatibility within 1.2 ppb CH4 and 0.23 ppb C2H6, and a collocated deployment with a NOAA Picarro system agreed within 1.8 ppb CH4. Instrument noise varied substantially amongst the instruments, with errors reaching up to 11 ppb CH4 and 2 ppb C2H6 for hourly means, with similar variability indicated in a 50 h cylinder test. With appropriate engineering and calibration, the Aeris MIRA Ultra has the potential to distinguish regional methane emission sources in many field settings.
- 10 February 2026
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 19 (3) , 965-981
Open AccessLaboratory and field assessment of mid-infrared absorption (MIRA) instrument performance for methane and ethane dry mole fractions
Concurrent measurements of methane (CH4) and ethane (C2H6) can be used to identify and separate methane sources, as ethane is present in thermogenic sources (e.g., oil and natural gas) but not in biogenic sources (e.g., agriculture). In this study, we evaluated the performance of multiple Aeris MIRA Ultra instruments (Versions 1 and 2) through controlled laboratory tests and tower-based deployments under field conditions. The systems were modified with an external pump, flow control, a Nafion dryer, and a custom-built auxiliary box to automate the system and transmit near real-time data. We determined the best calibration approach for our application, given practical limitations, to be a full calibration cycle (with ambient and high calibration cylinders) about once per day and an ambient calibration cylinder sampled hourly. Measurement uncertainty was assessed, including the uncertainty due to instrument noise as a function of calibration frequency, uncertainty in the water vapor correction, and cylinder assignment uncertainty. Instrument noise was the dominant source of uncertainty for C2H6, while the water vapor correction dominated the CH4 uncertainty. For Version 2 systems with hourly calibrations and a Nafion dryer with counterflow, the mean total uncertainty, including both systematic errors and noise, of hourly averages was 0.8–3.0 ppb CH4 and 0.35–0.37 ppb C2H6. Laboratory intercomparisons showed network compatibility within 1.2 ppb CH4 and 0.23 ppb C2H6, and a collocated deployment with a NOAA Picarro system agreed within 1.8 ppb CH4. Instrument noise varied substantially amongst the instruments, with errors reaching up to 11 ppb CH4 and 2 ppb C2H6 for hourly means, with similar variability indicated in a 50 h cylinder test. With appropriate engineering and calibration, the Aeris MIRA Ultra has the potential to distinguish regional methane emission sources in many field settings.