Sutton Elizabeth Wheelis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sutton Elizabeth Wheelis has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Danieli C. Rodrigues
Department of Bioengineering, University of Texas at Dallas (UTD), Richardson, USA
4 shared publications Gustavo P. Garlet
Bauru School of Dentistry, Department of Biological Sciences, University of São Paulo, Bauru - São Paulo 17012-901, Brazil
2 shared publicationsAlexandra Arteaga
Deparment of Bioengineering, University of Texas at DallasRINGGOLD, 800 W Campbell Rd, Richardson, Texas 75080, United States
1 shared publicationAna Gabriela Montaño‐Figueroa
Departamento de Investigación en Polímeros y Materiales, Universidad de Sonora, Sonora, Mexico
1 shared publicationBhuvana Lakkasettar Chandrashekar
Deparment of Bioengineering, University of Texas at DallasRINGGOLD, 800 W Campbell Rd, Richardson, Texas 75080, United States
1 shared publication- Brian M Hedden
Deparment of Bioengineering, University of Texas at Dallas, Dallas, Texas, United States
1 shared publication
Latest Publications
- 24 February 2021
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 7 (6) , 2392-2407
Cellular and Molecular Dynamics during Early Oral Osseointegration: A Comprehensive Characterization in the Lewis Rat
Objective: There is a need to improve the predictability of osseointegration in implant dentistry. Current literature uses a variety of in vivo titanium (Ti) implantation models to investigate failure modes and test new materials and surfaces. However, these models produce a variety of results, making comparison across studies difficult. The purpose of this study is to validate an oral osseointegration in the Lewis rat to provide a reproducible baseline to track the inflammatory response and healing of Ti implants. Methods: Ti screws (0.76 mm Ø × 2 mm length) were implanted into the maxillary diastema of 52 adult male Lewis rats. Peri-implant tissues were evaluated 2, 7, 14, and 30 days after implantation (n = 13). Seven of the 13 samples underwent microtomographic analysis, histology, histomorphometry, and immunohistochemistry to track healing parameters. The remaining six samples underwent quantitative polymerase chain reaction (qPCR) to evaluate gene expression of inflammation and bone remodeling markers over time. Results: This model achieved a 78.5% success rate. Successful implants had a bone to implant contact (BIC)% of 68.86 ± 3.15 at 30 days on average. Histologically, healing was similar to other rodent models: hematoma and acute inflammation at 2 days, initial bone formation at 7, advanced bone formation and remodeling at 14, and bone maturation at 30. qPCR indicated the highest expression of bone remodeling and inflammatory markers 2–7 days, before slowly declining to nonsurgery control levels at 14–30 days. Conclusion: This model combines cost-effectiveness and simplicity of a rodent model, while maximizing BIC, making it an excellent candidate for evaluation of new surfaces.
- 24 February 2021
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 7 (6) , 2392-2407
Cellular and Molecular Dynamics during Early Oral Osseointegration: A Comprehensive Characterization in the Lewis Rat
Objective: There is a need to improve the predictability of osseointegration in implant dentistry. Current literature uses a variety of in vivo titanium (Ti) implantation models to investigate failure modes and test new materials and surfaces. However, these models produce a variety of results, making comparison across studies difficult. The purpose of this study is to validate an oral osseointegration in the Lewis rat to provide a reproducible baseline to track the inflammatory response and healing of Ti implants. Methods: Ti screws (0.76 mm Ø × 2 mm length) were implanted into the maxillary diastema of 52 adult male Lewis rats. Peri-implant tissues were evaluated 2, 7, 14, and 30 days after implantation (n = 13). Seven of the 13 samples underwent microtomographic analysis, histology, histomorphometry, and immunohistochemistry to track healing parameters. The remaining six samples underwent quantitative polymerase chain reaction (qPCR) to evaluate gene expression of inflammation and bone remodeling markers over time. Results: This model achieved a 78.5% success rate. Successful implants had a bone to implant contact (BIC)% of 68.86 ± 3.15 at 30 days on average. Histologically, healing was similar to other rodent models: hematoma and acute inflammation at 2 days, initial bone formation at 7, advanced bone formation and remodeling at 14, and bone maturation at 30. qPCR indicated the highest expression of bone remodeling and inflammatory markers 2–7 days, before slowly declining to nonsurgery control levels at 14–30 days. Conclusion: This model combines cost-effectiveness and simplicity of a rodent model, while maximizing BIC, making it an excellent candidate for evaluation of new surfaces.
- 14 January 2020
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 6 (2) , 984-994
Investigation of the Early Healing Response to Dicationic Imidazolium-Based Ionic Liquids: A Biocompatible Coating for Titanium Implants
Dicationic Imidazolum-based ionic liquids with amino acid anions (IonL) have been proposed as a multifunctional coating for titanium dental implants, as their properties have been shown to address multiple early complicating factors while maintaining host cell compatibility. This study aims to evaluate effects of this coating on host response in the absence of complicating oral factors during the early healing period using a subcutaneous implantation model in the rat. IonLs with the best cytocompatibility and antimicrobial properties (IonL-Phe, IonL-Met) were chosen as coatings. Three different doses were applied to cpTi disks and subcutaneously implanted into 36 male Lewis rats. Rats received 2 implants: 1 coated implant on one side and an uncoated implant on the contralateral sides (n=3 per formulation, per dose). Peri-implant tissue was evaluated 2 and 14 days after implantation with H&E staining and IHC markers associated with macrophage polarization as well as molecular analysis (qPCR) for inflammatory and healing markers. H&E stains revealed the presence of the coating, blood clots and inflammatory infiltrate at 2 days around all implants. At 14 days, inflammation had receded with more developed connective tissue with fibroblasts, blood vessels in certain doses of coated and uncoated samples with no foreign body giant cells. This study demonstrated that IonL at the appropriate concentration does not significantly interfere with and healing and Ti foreign body response. Results regarding optimal dose and formulation from this study will be applied in future studies using an oral osseointegration model.
- 14 January 2020
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 6 (2) , 984-994
Investigation of the Early Healing Response to Dicationic Imidazolium-Based Ionic Liquids: A Biocompatible Coating for Titanium Implants
Dicationic Imidazolum-based ionic liquids with amino acid anions (IonL) have been proposed as a multifunctional coating for titanium dental implants, as their properties have been shown to address multiple early complicating factors while maintaining host cell compatibility. This study aims to evaluate effects of this coating on host response in the absence of complicating oral factors during the early healing period using a subcutaneous implantation model in the rat. IonLs with the best cytocompatibility and antimicrobial properties (IonL-Phe, IonL-Met) were chosen as coatings. Three different doses were applied to cpTi disks and subcutaneously implanted into 36 male Lewis rats. Rats received 2 implants: 1 coated implant on one side and an uncoated implant on the contralateral sides (n=3 per formulation, per dose). Peri-implant tissue was evaluated 2 and 14 days after implantation with H&E staining and IHC markers associated with macrophage polarization as well as molecular analysis (qPCR) for inflammatory and healing markers. H&E stains revealed the presence of the coating, blood clots and inflammatory infiltrate at 2 days around all implants. At 14 days, inflammation had receded with more developed connective tissue with fibroblasts, blood vessels in certain doses of coated and uncoated samples with no foreign body giant cells. This study demonstrated that IonL at the appropriate concentration does not significantly interfere with and healing and Ti foreign body response. Results regarding optimal dose and formulation from this study will be applied in future studies using an oral osseointegration model.
- 15 August 2018
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 20 (5) , 838-847
Effects of titanium oxide surface properties on bone‐forming and soft tissue‐forming cells
Background: Previous studies have concluded that certain titanium oxide (TiO2) surface properties promote bone‐forming cell attachment. However, no comprehensive studies have investigated the effects of TiO2 surface and film morphology on hard and soft tissues.Purpose: The aim of this study is to understand the effects of TiO2 morphology on the proliferation and differentiation of murine preosteoblasts (MC3T3‐E1) and proliferation of human gingival fibroblasts (HGF‐1) using in vitro experiments.Materials and Methods: Samples were fabricated with several TiO2 thickness and crystalline structure to mimic various dental implant surfaces. in vitro analysis was performed for 1, 3, and 7 days on these samples to assess the viability of MC3T3‐E1 and HGF‐1 cells in contact with the modified oxide surfaces.Results: Results showed that HGF‐1 cells exhibited no significant difference in viability on modified oxide surfaces versus a titanium control across experiments. MC3T3‐E1 cells exhibited a significantly higher viability for the modified oxide surface in 1 day experiments, but not in 3 or 7 day experiments. Alkaline phosphatase expression in MC3T3‐E1 was not significantly different on modified oxide surfaces versus the control across all experiments. A slight positive trend in viability was observed for cells in contact with rougher modified oxide surfaces versus a titanium control in both cell types.Conclusions: These observations suggest that crystallinity and thickness do not affect the long‐term viability of hard or soft tissue cells when compared to a cpTi surface. Therefore, treatments like anodization on implant components may not directly affect the attachment of hard or soft tissue cells in vivo.
- 15 August 2018
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 20 (5) , 838-847
Effects of titanium oxide surface properties on bone‐forming and soft tissue‐forming cells
Background: Previous studies have concluded that certain titanium oxide (TiO2) surface properties promote bone‐forming cell attachment. However, no comprehensive studies have investigated the effects of TiO2 surface and film morphology on hard and soft tissues.Purpose: The aim of this study is to understand the effects of TiO2 morphology on the proliferation and differentiation of murine preosteoblasts (MC3T3‐E1) and proliferation of human gingival fibroblasts (HGF‐1) using in vitro experiments.Materials and Methods: Samples were fabricated with several TiO2 thickness and crystalline structure to mimic various dental implant surfaces. in vitro analysis was performed for 1, 3, and 7 days on these samples to assess the viability of MC3T3‐E1 and HGF‐1 cells in contact with the modified oxide surfaces.Results: Results showed that HGF‐1 cells exhibited no significant difference in viability on modified oxide surfaces versus a titanium control across experiments. MC3T3‐E1 cells exhibited a significantly higher viability for the modified oxide surface in 1 day experiments, but not in 3 or 7 day experiments. Alkaline phosphatase expression in MC3T3‐E1 was not significantly different on modified oxide surfaces versus the control across all experiments. A slight positive trend in viability was observed for cells in contact with rougher modified oxide surfaces versus a titanium control in both cell types.Conclusions: These observations suggest that crystallinity and thickness do not affect the long‐term viability of hard or soft tissue cells when compared to a cpTi surface. Therefore, treatments like anodization on implant components may not directly affect the attachment of hard or soft tissue cells in vivo.
- 6 December 2017
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 20 (2) , 180-190
Surface characterization of titanium implant healing abutments before and after placement
Background: Implant healing abutments (IHA) have a vital role in soft tissue healing after implant placement. Although there is thorough investigation on the implant surface, little is known about the effects potentially damaging oral conditions impose on healing abutments.Purpose: To characterize the surface of titanium healing abutments before and after clinical placement to understand the effects of the oral environment and time on the device surface.Materials and Methods: Ten regular Straumann IHA were subjected to characterization pre and postplacement to elucidate the effects of the oral environment on device surfaces. Changes in surface crystallinity, morphology, and elemental composition were monitored with Raman spectroscopy, scanning electron microscopy, optical microscopy, and x‐ray photoelectron spectroscopy, respectively. In addition, corrosion rate and polarization resistance were obtained to assess electrochemical device stability after placement.Results: Control analysis indicated the titanium oxide of IHAs was thicker than natural commercially pure titanium and had the structure of crystalline anatase. After removal, the abutments possessed large amounts of biological debris, visible scratches, and discoloration sparsely on the surface. Spectroscopic analysis revealed the titanium oxide on the surface of IHAs was structurally unchanged, with crystalline titanium dioxide still present on the surface. Electrochemical results revealed that implanted healing abutments possessed a significantly higher corrosion rate than controls (change in corrosion rate = 2.34 ± 0.58 nm/year).Conclusions: Healing abutments were stable in the oral environment due to the chemical stability of the oxide, and were likely subjected to abrasions from unintentional loading and oral hygiene techniques.
- 6 December 2017
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 20 (2) , 180-190
Surface characterization of titanium implant healing abutments before and after placement
Background: Implant healing abutments (IHA) have a vital role in soft tissue healing after implant placement. Although there is thorough investigation on the implant surface, little is known about the effects potentially damaging oral conditions impose on healing abutments.Purpose: To characterize the surface of titanium healing abutments before and after clinical placement to understand the effects of the oral environment and time on the device surface.Materials and Methods: Ten regular Straumann IHA were subjected to characterization pre and postplacement to elucidate the effects of the oral environment on device surfaces. Changes in surface crystallinity, morphology, and elemental composition were monitored with Raman spectroscopy, scanning electron microscopy, optical microscopy, and x‐ray photoelectron spectroscopy, respectively. In addition, corrosion rate and polarization resistance were obtained to assess electrochemical device stability after placement.Results: Control analysis indicated the titanium oxide of IHAs was thicker than natural commercially pure titanium and had the structure of crystalline anatase. After removal, the abutments possessed large amounts of biological debris, visible scratches, and discoloration sparsely on the surface. Spectroscopic analysis revealed the titanium oxide on the surface of IHAs was structurally unchanged, with crystalline titanium dioxide still present on the surface. Electrochemical results revealed that implanted healing abutments possessed a significantly higher corrosion rate than controls (change in corrosion rate = 2.34 ± 0.58 nm/year).Conclusions: Healing abutments were stable in the oral environment due to the chemical stability of the oxide, and were likely subjected to abrasions from unintentional loading and oral hygiene techniques.