ACAmy L. de Jongh Curry

Amy L. de Jongh Curry

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Amy L. de Jongh Curry has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Focality of the Induced E-Field Is a Contributing Factor in the Choice of TMS Parameters: Evidence from a 3D Computational Model of the Human Brain

    by Deepika Konakanchi, Amy L. de Jongh Curry, Robert S. Waters, Shalini Narayana

    Transcranial magnetic stimulation (TMS) is a promising, non-invasive approach in the diagnosis and treatment of several neurological conditions. However, the specific results in the cortex of the magnitude and spatial distribution of the secondary electrical field (E-field) resulting from TMS at different stimulation sites/orientations and varied TMS parameters are not clearly understood. The objective of this study is to identify the impact of TMS stimulation site and coil orientation on the induced E-field, including spatial distribution and the volume of activation in the cortex across brain areas, and hence demonstrate the need for customized optimization, using a three-dimensional finite element model (FEM). A considerable difference was noted in E-field values and distribution at different brain areas. We observed that the volume of activated cortex varied from 3000 to 7000 mm3 between the selected nine clinically relevant coil locations. Coil orientation also changed the induced E-field by a maximum of 10%, and we noted the least optimal values at the standard coil orientation pointing to the nose. The volume of gray matter activated varied by 10% on average between stimulation sites in homologous brain areas in the two hemispheres of the brain. This FEM simulation model clearly demonstrates the importance of TMS parameters for optimal results in clinically relevant brain areas. The results show that TMS parameters cannot be interchangeably used between individuals, hemispheres, and brain areas. The focality of the TMS induced E-field along with its optimal magnitude should be considered as critical TMS parameters that should be individually optimized.


  • Open Access

    Telemetry-controlled simultaneous stimulation-and-recording device (SRD) to study interhemispheric cortical circuits in rat primary somatosensory (SI) cortex

    by John T. Ramshur, Bashir I. Morshed, Amy L. de Jongh Curry, Robert S. Waters

    A growing need exists for neuroscience platforms that can perform simultaneous chronic recording and stimulation of neural tissue in animal models in a telemetry-controlled fashion with signal processing for analysis of the chronic recording data and external triggering capability. We describe the system design, testing, evaluation, and implementation of a wireless simultaneous stimulation-and-recording device (SRD) for modulating cortical circuits in physiologically identified sites in primary somatosensory (SI) cortex in awake-behaving and freely-moving rats. The SRD was developed using low-cost electronic components and open-source software. The function of the SRD was assessed by bench and in-vivo testing. The SRD recorded spontaneous spiking and bursting neuronal activity, evoked responses to programmed intracortical microstimulation (ICMS) delivered internally by the SRD, and evoked responses to external peripheral forelimb stimulation. The SRD is capable of wireless stimulation and recording on a predetermined schedule or can be wirelessly synchronized with external input as would be required in behavioral testing prior to, during, and following ICMS.


  • Open Access

    Esophageal electric fields are predictive of atrial cardioversion success-a finite element analysis

    by David A. Fitch, Amy L. de Jongh Curry

    Esophageal electric fields are predictive of atrial cardioversion success—a finite element analysis

  • Esophageal Electric Fields are Predictive of Atrial Defibrillation Thresholds

    by David A. Fitch, Judith Soberman, Amy L. DE Jongh Curry

    Atrial fibrillation (AF) is a common cardiac arrhythmia characterized by disorganized cardiac electrical activity. Defibrillation electrode placement has been shown to affect the amount of energy and number of shocks required to defibrillate. The objective of this study was to investigate the relationship between esophageal electric fields (EEFs) and atrial defibrillation thresholds (ADFTs) to determine the feasibility of using EEFs during a low-strength shock to predict patient-specific defibrillation electrode placements. AF was induced and defibrillated according to a Bayesian four-shock protocol for 12-electrode placements in six pigs. EEFs were measured during each of the four shocks of the protocol and during a 1-J shock for each electrode placement. Squared EEFs (EEF(2) s) during all shocks were compared to the ADFTs using a linear regression. There was a negative relationship between EEF(2) s during the 1-J shocks and ADFTs, with median R(2) values of 0.863 and 0.840 for anterior-anterior (AA) and anterior-posterior (AP) electrode placements, respectively. There was a strong, positive relationship between applied energy and EEF(2) s, with median R(2) values of at least 0.866 for all animals. The placement with the highest EEF(2) resulted in the lowest ADFT for both AA and AP placements in four of six pigs. In the other two animals, this held for one electrode set but not both. There was a strong negative relationship between EEF(2) s during 1-J shocks and ADFTs for both AA and AP electrode placements. These preliminary results suggest that using EEF(2) s to predict patient-specific electrode placements is feasible.


  • Transthoracic Atrial Defibrillation Energy Thresholds are Correlated to Uniformity of Current Density Distributions

    by Leslie C. Hunt, Amy L. de Jongh Curry

    Previous studies have shown that successful defibrillation depends on the uniformity of current density in the heart and the percentage of total current reaching the heart. This study uses an anatomically-realistic finite element computer model of the human torso for external atrial defibrillation to (1) examine the defibrillation energy thresholds and current density distributions for common clinical paddle placements and (2) investigate the effects of electrode shifts on these defibrillation parameters. The model predicts atrial defibrillation threshold (AD FT) energy by requiring a voltage gradient of 5 V/cm over at least 95% of atrial myocardium. This study finds that variation in electrode placement by only a few centimeters increases ADFTs by up to 46% with a corresponding change of 38% between the average current density in the left and right atria and 34% between the heterogeneity indices of atrial current density distributions. Additionally, the heterogeneity index, or degree of uniformity, is linearly correlated to the ADFT (R2=0.9). We suggest that uniformity of current density distribution, in addition to minimum current density, may be an important parameter to use for predicting successful defibrillation when testing new electrode placements


  • Esophageal Electric Fields are Correlated to Atrial Defibrillation Thresholds: Towards Patient-Specific Optimization of External Atrial Defibrillation

    by David A. Fitch, Judith E. Soberman, Amy de Jongh Curry

    Studies have investigated the effect of defibrillator paddle position on the efficacy of external electrocardioversion of atrial fibrillation, without agreeing upon an optimal placement. We wish to investigate using esophageal electric fields (EEFs) to predict atrial defibrillation thresholds (ADFTs) on a patient-specific basis. We propose to (1) investigate the relationship between EEFs and ADFTs using computer simulations, (2) develop an esophageal probe that can accurately measure three-dimensional electric fields and (3) investigate the relationship between EEFs and ADFTs values in-vivo. Sixteen anterior-anterior and eleven anterior-posterior placements were simulated yielding a negative relationship between EEFs and ADFTs (R2=0.91 and 0.93, respectively). An esophageal probe was developed that accurately measures EEFs. Animal studies showed a negative relationship between EEFs and ADFTs. This data suggests using EEFs to predict ADFTs on a patient-specific basis is plausible


  • Esophageal Electric Fields are Correlated to Atrial Defibrillation Thresholds: Towards Patient-Specific Optimization of External Atrial Defibrillation

    by David A. Fitch, Judith E. Soberman, Amy de Jongh Curry

    Studies have investigated the effect of defibrillator paddle position on the efficacy of external electrocardioversion of atrial fibrillation, without agreeing upon an optimal placement. We wish to investigate using esophageal electric fields (EEFs) to predict atrial defibrillation thresholds (ADFTs) on a patient-specific basis. We propose to (1) investigate the relationship between EEFs and ADFTs using computer simulations, (2) develop an esophageal probe that can accurately measure three-dimensional electric fields and (3) investigate the relationship between EEFs and ADFTs values in-vivo. Sixteen anterior-anterior and eleven anterior-posterior placements were simulated yielding a negative relationship between EEFs and ADFTs (R2=0.91 and 0.93, respectively). An esophageal probe was developed that accurately measures EEFs. Animal studies showed a negative relationship between EEFs and ADFTs. This data suggests using EEFs to predict ADFTs on a patient-specific basis is plausible

  • Transthoracic Atrial Defibrillation Energy Thresholds are Correlated to Uniformity of Current Density Distributions

    by Leslie C. Hunt, Amy L. de Jongh Curry

    Previous studies have shown that successful defibrillation depends on the uniformity of current density in the heart and the percentage of total current reaching the heart. This study uses an anatomically-realistic finite element computer model of the human torso for external atrial defibrillation to (1) examine the defibrillation energy thresholds and current density distributions for common clinical paddle placements and (2) investigate the effects of electrode shifts on these defibrillation parameters. The model predicts atrial defibrillation threshold (AD FT) energy by requiring a voltage gradient of 5 V/cm over at least 95% of atrial myocardium. This study finds that variation in electrode placement by only a few centimeters increases ADFTs by up to 46% with a corresponding change of 38% between the average current density in the left and right atria and 34% between the heterogeneity indices of atrial current density distributions. Additionally, the heterogeneity index, or degree of uniformity, is linearly correlated to the ADFT (R2=0.9). We suggest that uniformity of current density distribution, in addition to minimum current density, may be an important parameter to use for predicting successful defibrillation when testing new electrode placements

  • Left ventricular geometry immediately following defibrillation: shock-induced relaxation

    by Amy L. De Jongh, Vijaya Ramanathan, Brent K. Hoffmeister, Robert A. Malkin

    A previous two-dimensional (2D) ultrasound study suggested that there is relaxation of the myocardium after defibrillation. The 2D study could not measure activity occurring within the first 33 ms after the shock, a period that may be critical for discriminating between shock- and excitation-induced relaxation. The objective of our study was to determine the left ventricular (LV) geometry during the first 33 ms after defibrillation. Biphasic defibrillation shocks were delivered 5–50 s after the induction of ventricular fibrillation in each of the seven dogs. One-dimensional, short-axis ultrasound images of the LV cavity were acquired at a rate of 250 samples/s. The LV cavity diameter was computed from 32 ms before to 32 ms after the shock. Preshock and postshock percent changes in LV diameter were analyzed as a function of time with the use of regression analysis. The normalized mean pre- and postshock slopes (0.2 ± 2.2 and 3.3 ± 7.9% per 10 ms) were significantly different ( P < 0.01). The postshock slope was positive ( P < 0.005). Our results confirm that the bulk of the myocardium is relaxing immediately after defibrillation.


  • Defibrillation Efficacy of Different Electrode Placements in a Human Thorax Model

    by Amy L. DE Jongh, Emilia G. Entcheva, Janice A. Replogle, Robert S. Booker, Bruce H. Kenknight, Frank J. Claydon

    The objective of this study was to measure the defibrillation threshold (DFT) associated with different electrode placements using a three‐dimensional anatomically realistic finite element model of the human thorax. Coil electrodes (Endotak DSP, model 125, Guidant/CPI) were placed in the RV apex along the lateral wall (RV), withdrawn 10 mm away from the RV apex along the lateral wall (RVprox), in the RV apex along the anterior septum (RVseptal), and in the SVC. An active pulse generator (can) was placed in the subcutaneous prepectoral space. Five electrode configurations were studied: RV → SVC, RVprox→ SVC, RVSEPTAL→SVC, RV →Can, and RV →SVC+Can. DFTs are defined as the energy required to produce a potential gradient of at least 5 V/cm in 95% of the ventricular myocardium. DFTs for RV → SVC, RVPROX→ SVC, RVseptal→ SVC, RV → Can, and RV → SVC + Can were 10, 16, 7, 9, and 6 J, respectively. The DFTs measured at each configuration fell within one standard deviation of the mean DFTs reported in clinical studies using the Endotak leads. The relative changes in DFT among electrode configurations also compared favorably. This computer model allows measurements of DFT or other defibrillation parameters with several different electrode configurations saving time and cost of clinical studies.