Isador H. Lieberman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Isador H. Lieberman has a total of 166 co-authors. Here are the top co-authors by number of shared publications:
Xiaobang Hu
University of Texas South Western Medical Center, Dallas, USA
15 shared publications- Xiaobang Hu
Department of Pathology and Laboratory Medicine, Penn State College of Medicine, Penn State Health Milton S. Hershey Medical Center, Hershey, USA
14 shared publications - Ram Haddas
Department of Orthopaedics, University of Rochester Medical Center, Rochester, USA
11 shared publications Stanley Kisinde
Scoliosis and Spine Tumor Center, Texas Back Institute, Plano, USA
7 shared publicationsDonna D. Ohnmeiss
Texas Back Institute Research Foundation, Plano, TX
5 shared publicationsAlexander M. Satin
Texas Back Institute
4 shared publications
Latest Publications
- 27 May 2025
- Published by Springer Nature in European Spine Journal
- p. 1-14
Feasibility and intra-operative accuracy of robotic-guided stacked S1AI and S2AI screw placement
Background Pelvic fixation with S1 and S2 sacral alar-iliac screws (S1 & S2 AIs) in a stacked configuration can help to offset the exceedingly large forces across the lumbosacral junction in long spinal fusion constructs extending to the sacrum. Traditionally, these modalities of pelvic fixation have been heavily reliant on fluoroscopy and other intraoperative imaging for safe insertion through the sacral alar, the sacroiliac joint and into the narrow corridor of the wing of the ilium. However, recently, computer-assisted robotic guidance and its intraoperative re-registration function has allowed for safe and accurate placement, and intraoperative accuracy assessment of S1 & S2 AIs while minimizing additional radiation associated with fluoroscopic-guidance. Objective To review and report our experience with, and assess the intraoperative accuracy and feasibility of, robotic-guided S1AI and S2AI screws inserted in a stacked bedrock configuration as part of instrumented constructs aimed to achieve spinopelvic fusion. Study design / setting Retrospective Cohort study. Outcome measures We evaluated the number of sacral spinopelvic fixation screws successfully implanted under robotic guidance and the deviation of the achieved screw trajectories from the pre-operatively planned trajectories. The presence and orientation of sacral alar-iliac cortical screw breaches and other intra- or postoperative complications directly related to placement of the stacked S1AI or S2AI implants were also evaluated. Methods We included all patients that underwent posterior instrumented spinal fusion up to the pelvis under computer-assisted robotic guidance with open bilateral sacroiliac joint fixation and fusion using S1 & S2 AIs from June 2022 to December 2024. Patients were excluded if the pelvic fixation was not applied in a stacked bedrock configuration. Patient demographics, intra-operative technical errors, complications and other surgical parameters, and any post-operative complications were reviewed and recorded. The data was collected from clinical charts in the electronic medical records system, radiologic images from PACS, and surgical details from operative notes. We also obtained intraoperative secondary registration images for assessment of accuracy, interpreted as the deviation (mm) of the achieved trajectories from the preoperatively planned trajectories in the coronal and sagittal planes, from the robotic planning software system. Results 51 patients (32 F & 19 M), mean age 66 (34–80) years, underwent placement of S1AI and S2AI screws under computer-assisted robotic guidance in a stacked bedrock configuration. The most common primary indication for instrumented spinopelvic fusion in these cases was scoliosis (degenerative scoliosis = 26, idiopathic scoliosis = 8), followed in descending order by degenerative spondylolisthesis [10] and kyphosis [7]. Robotic guidance was successful in all 204 screws (4 screws per patient). There was no significant difference in the length of implants inserted on either side of the pelvis, however, the mean length of the S1 AIs (80 mm) was significantly shorter than the S2 AIs (90 mm) [p = 0.005]. The overall mean accuracy in all planes was 2.05 ± 1.97 mm; larger values of proximal deviation were associated with similarly larger values of distal deviation. The mean deviation of the revision screws was greater (3.5 ± 2.16) than that of newly inserted screws (1.72 ± 1.30) [p-value = 0.003]. There were no complications directly related to the robotic-guided placement of the screws. 11 iliac cortical breaches − 5 each through the lateral and medial cortices, and one through the inferior cortex - were identified in 10 patients on post-operative CT images but with no further clinical consequences as they only invaded the bulk masses of the surrounding mm. Conclusion Robotic-guided placement of S1 and S2 AI implants in a stacked bedrock configuration for spinopelvic fixation and fusion is feasible with clinically acceptable results. Secondary registration and intra-operative accuracy assessment of screw placement may help to avoid the need for revision surgery related to misplacement of these implants.
- 27 May 2025
- Published by Springer Nature in European Spine Journal
- p. 1-14
Feasibility and intra-operative accuracy of robotic-guided stacked S1AI and S2AI screw placement
Background Pelvic fixation with S1 and S2 sacral alar-iliac screws (S1 & S2 AIs) in a stacked configuration can help to offset the exceedingly large forces across the lumbosacral junction in long spinal fusion constructs extending to the sacrum. Traditionally, these modalities of pelvic fixation have been heavily reliant on fluoroscopy and other intraoperative imaging for safe insertion through the sacral alar, the sacroiliac joint and into the narrow corridor of the wing of the ilium. However, recently, computer-assisted robotic guidance and its intraoperative re-registration function has allowed for safe and accurate placement, and intraoperative accuracy assessment of S1 & S2 AIs while minimizing additional radiation associated with fluoroscopic-guidance. Objective To review and report our experience with, and assess the intraoperative accuracy and feasibility of, robotic-guided S1AI and S2AI screws inserted in a stacked bedrock configuration as part of instrumented constructs aimed to achieve spinopelvic fusion. Study design / setting Retrospective Cohort study. Outcome measures We evaluated the number of sacral spinopelvic fixation screws successfully implanted under robotic guidance and the deviation of the achieved screw trajectories from the pre-operatively planned trajectories. The presence and orientation of sacral alar-iliac cortical screw breaches and other intra- or postoperative complications directly related to placement of the stacked S1AI or S2AI implants were also evaluated. Methods We included all patients that underwent posterior instrumented spinal fusion up to the pelvis under computer-assisted robotic guidance with open bilateral sacroiliac joint fixation and fusion using S1 & S2 AIs from June 2022 to December 2024. Patients were excluded if the pelvic fixation was not applied in a stacked bedrock configuration. Patient demographics, intra-operative technical errors, complications and other surgical parameters, and any post-operative complications were reviewed and recorded. The data was collected from clinical charts in the electronic medical records system, radiologic images from PACS, and surgical details from operative notes. We also obtained intraoperative secondary registration images for assessment of accuracy, interpreted as the deviation (mm) of the achieved trajectories from the preoperatively planned trajectories in the coronal and sagittal planes, from the robotic planning software system. Results 51 patients (32 F & 19 M), mean age 66 (34–80) years, underwent placement of S1AI and S2AI screws under computer-assisted robotic guidance in a stacked bedrock configuration. The most common primary indication for instrumented spinopelvic fusion in these cases was scoliosis (degenerative scoliosis = 26, idiopathic scoliosis = 8), followed in descending order by degenerative spondylolisthesis [10] and kyphosis [7]. Robotic guidance was successful in all 204 screws (4 screws per patient). There was no significant difference in the length of implants inserted on either side of the pelvis, however, the mean length of the S1 AIs (80 mm) was significantly shorter than the S2 AIs (90 mm) [p = 0.005]. The overall mean accuracy in all planes was 2.05 ± 1.97 mm; larger values of proximal deviation were associated with similarly larger values of distal deviation. The mean deviation of the revision screws was greater (3.5 ± 2.16) than that of newly inserted screws (1.72 ± 1.30) [p-value = 0.003]. There were no complications directly related to the robotic-guided placement of the screws. 11 iliac cortical breaches − 5 each through the lateral and medial cortices, and one through the inferior cortex - were identified in 10 patients on post-operative CT images but with no further clinical consequences as they only invaded the bulk masses of the surrounding mm. Conclusion Robotic-guided placement of S1 and S2 AI implants in a stacked bedrock configuration for spinopelvic fixation and fusion is feasible with clinically acceptable results. Secondary registration and intra-operative accuracy assessment of screw placement may help to avoid the need for revision surgery related to misplacement of these implants.
- 26 April 2025
- Published by Springer Nature in European Spine Journal
- p. 1-16
Modalities of failure of cement-augmented pedicle screws
Introduction Cement-augmented pedicle screw instrumentation procedures are performed for stabilization in patients with surgical spinal conditions with poor bone quality at the target levels. Although this is done to combat the risk of failure due to loosening, cutting out or pulling out of the screws, failure may still occur. The purpose of this study was to identify the modalities and rates of failure of CAPSI constructs to better predict occurrence of failure. Methods We retrospectively reviewed clinical data of patients who underwent CAPSI fusion procedures between 2010 and 2022. We collected pre, intra and post-operative clinical and radiographic data. Results 621 pedicle screws in 319 levels were augmented out of 1333 screws in 809 instrumented levels in 120 patients. F:M = 3:1; mean age 68.6 years and mean BMI 27.10. The mean length of follow up overall was 2.2 years (Range 7 days–11 years). The most common surgical indications were degenerative scoliosis and osteoporotic fractures. Construct failure occurred in 32 cases; seven cases were associated with trauma and 11 cases presented with a neurologic deficit. The most common modality of failure was osteonecrotic collapse (20 cases); proximal construct failure occurred in 22 cases; there was evidence of haloing at the screw-bone-cement interfaces in 23 out 32 cases. 21 out of 32 cases required revision surgical procedures within an average of 453 days. Conclusion Failure of CAPSI constructs occurred in 26.7% of patients. High occurrence of osteonecrotic collapse and haloing at the screw-cement-bone interfaces likely represents a relationship with construct failure.
- 26 April 2025
- Published by Springer Nature in European Spine Journal
- p. 1-16
Modalities of failure of cement-augmented pedicle screws
Introduction Cement-augmented pedicle screw instrumentation procedures are performed for stabilization in patients with surgical spinal conditions with poor bone quality at the target levels. Although this is done to combat the risk of failure due to loosening, cutting out or pulling out of the screws, failure may still occur. The purpose of this study was to identify the modalities and rates of failure of CAPSI constructs to better predict occurrence of failure. Methods We retrospectively reviewed clinical data of patients who underwent CAPSI fusion procedures between 2010 and 2022. We collected pre, intra and post-operative clinical and radiographic data. Results 621 pedicle screws in 319 levels were augmented out of 1333 screws in 809 instrumented levels in 120 patients. F:M = 3:1; mean age 68.6 years and mean BMI 27.10. The mean length of follow up overall was 2.2 years (Range 7 days–11 years). The most common surgical indications were degenerative scoliosis and osteoporotic fractures. Construct failure occurred in 32 cases; seven cases were associated with trauma and 11 cases presented with a neurologic deficit. The most common modality of failure was osteonecrotic collapse (20 cases); proximal construct failure occurred in 22 cases; there was evidence of haloing at the screw-bone-cement interfaces in 23 out 32 cases. 21 out of 32 cases required revision surgical procedures within an average of 453 days. Conclusion Failure of CAPSI constructs occurred in 26.7% of patients. High occurrence of osteonecrotic collapse and haloing at the screw-cement-bone interfaces likely represents a relationship with construct failure.
- Open Access
- 9 August 2024
- Published by MDPI AG in Surgical Techniques Development
- Vol. 13 (3) , 278-293
Perioperative Benefits of a 3D Printed Spine Biomodel in the Setting of Congenital Scoliosis Surgery
The spine community is continuously adding to its armamentarium of intraoperative techniques for visualization and instrumentation of the spine. Recently, three-dimensional printed spine models were introduced for use in preoperative planning, surgical simulation, and intraoperative guidance. We present a 14-year old African male with congenital kyphoscoliosis, small stature, an obvious gibbus deformity and coronal imbalance, who underwent a three-staged posterior surgical correction procedure, during which a 3D-printed spine biomodel was utilized for better appreciation of his complex spinal deformity patho-anatomy. During the first stage of the procedure, he developed diminished lower extremity motor strength bilaterally and bowel/bladder control, but, following his third stage procedure and with focused rehabilitation efforts, he has regained full control of his bowel and bladder function, and is able to ambulate and perform activities of daily living independently, albeit still requiring intermittent walking support with a single forearm crutch due to residual left leg weakness. The 3D spine biomodel functioned successfully as a valuable tool and surrogate anatomic blueprint for the surgeons, enabling adequate appreciation of the complex bony anatomy which could not be easily resolved on the conventionally available imaging modalities, intraoperative navigation or robotic platform. Theoretically, up to $2900 USD in savings, translated from the mean estimated time saved per procedure with the use 3D-printed spine models has been proposed in some studies. Therefore, 3D-printed spine models have utility in complex spinal deformity correction surgery.
- 9 August 2024
- Published by MDPI AG in Surgical Techniques Development
- Vol. 13 (3) , 278-293
Open AccessPerioperative Benefits of a 3D Printed Spine Biomodel in the Setting of Congenital Scoliosis Surgery
The spine community is continuously adding to its armamentarium of intraoperative techniques for visualization and instrumentation of the spine. Recently, three-dimensional printed spine models were introduced for use in preoperative planning, surgical simulation, and intraoperative guidance. We present a 14-year old African male with congenital kyphoscoliosis, small stature, an obvious gibbus deformity and coronal imbalance, who underwent a three-staged posterior surgical correction procedure, during which a 3D-printed spine biomodel was utilized for better appreciation of his complex spinal deformity patho-anatomy. During the first stage of the procedure, he developed diminished lower extremity motor strength bilaterally and bowel/bladder control, but, following his third stage procedure and with focused rehabilitation efforts, he has regained full control of his bowel and bladder function, and is able to ambulate and perform activities of daily living independently, albeit still requiring intermittent walking support with a single forearm crutch due to residual left leg weakness. The 3D spine biomodel functioned successfully as a valuable tool and surrogate anatomic blueprint for the surgeons, enabling adequate appreciation of the complex bony anatomy which could not be easily resolved on the conventionally available imaging modalities, intraoperative navigation or robotic platform. Theoretically, up to $2900 USD in savings, translated from the mean estimated time saved per procedure with the use 3D-printed spine models has been proposed in some studies. Therefore, 3D-printed spine models have utility in complex spinal deformity correction surgery.
- Open Access
- 30 September 2022
- Published by The Korean Spinal Neurosurgery Society in Neurospine
- Vol. 19 (3) , 773-779
Minimally Invasive Posterior Facet Decortication and Fusion Using Navigated Robotic Guidance: Feasibility and Workflow Optimization
Minimally invasive spine surgery reduces tissue dissection and retraction, decreasing the morbidity associated with traditional open spine surgery by decreasing blood loss, blood transfusion, complications, and pain. One of the key challenges with a minimally invasive approach is achieving consistent posterior fusion. Although advantageous in all fusion surgeries, solid posterior fusion is particularly important in spinal deformity, revisions, and fusions without anterior column support. A minimally invasive surgical approach accomplished without sacrificing the quality of the posterior fusion has the potential to decrease both short- and long-term complications compared to the traditional open techniques. Innovations in navigated and robotic-assisted spine surgery continue to address this need. In this article, we will outline the feasibility of achieving posterior facet fusion using the Mazor X Stealth Edition Robotic Guidance System.
- 30 September 2022
- Published by The Korean Spinal Neurosurgery Society in Neurospine
- Vol. 19 (3) , 773-779
Open AccessMinimally Invasive Posterior Facet Decortication and Fusion Using Navigated Robotic Guidance: Feasibility and Workflow Optimization
Minimally invasive spine surgery reduces tissue dissection and retraction, decreasing the morbidity associated with traditional open spine surgery by decreasing blood loss, blood transfusion, complications, and pain. One of the key challenges with a minimally invasive approach is achieving consistent posterior fusion. Although advantageous in all fusion surgeries, solid posterior fusion is particularly important in spinal deformity, revisions, and fusions without anterior column support. A minimally invasive surgical approach accomplished without sacrificing the quality of the posterior fusion has the potential to decrease both short- and long-term complications compared to the traditional open techniques. Innovations in navigated and robotic-assisted spine surgery continue to address this need. In this article, we will outline the feasibility of achieving posterior facet fusion using the Mazor X Stealth Edition Robotic Guidance System.
- 19 August 2022
- Published by Elsevier in The Spine Journal
- Vol. 22 (9) , S55-S56
102. An introductory investigation of standing postural control ‘error’ and its relation to balance in adult spinal deformity surgery patients
- 19 August 2022
- Published by Elsevier in The Spine Journal
- Vol. 22 (9) , S55-S56
102. An introductory investigation of standing postural control ‘error’ and its relation to balance in adult spinal deformity surgery patients
- 19 August 2022
- Published by Elsevier in The Spine Journal
- Vol. 22 (9) , S16-S17
32. An introductory investigation of postural balance strategy reliance using a novel force plate analysis technique among common degenerative spinal pathologies
- 19 August 2022
- Published by Elsevier in The Spine Journal
- Vol. 22 (9) , S16-S17
32. An introductory investigation of postural balance strategy reliance using a novel force plate analysis technique among common degenerative spinal pathologies
- 28 June 2022
- Published by International Journal of Spine Surgery in International Journal of Spine Surgery
- Vol. 16 (S2) , S44-S49
Can Robotic Spine Surgery Become the Standard of Care?
Concerns regarding traditional techniques led to the development of robotic systems to facilitate the safe and accurate placement of pedicle screws. The Mazor Spine Assist was the first robotic spine surgery (RSS) platform to receive US Food and Drug Administration approval in 2004. Since then, there has been a steady increase in the application of RSS with several additional iterations of the Mazor platform and other competing systems receiving approval. As the indications, potential benefits, and utilization of RSS continue to expand, the question naturally arises as to whether RSS will eventually become the standard of care for spine surgery. In this article, we review the available evidence and experience with RSS and discuss the potential for RSS to become the medical standard of care.
- 28 June 2022
- Published by International Journal of Spine Surgery in International Journal of Spine Surgery
- Vol. 16 (S2) , S44-S49
Can Robotic Spine Surgery Become the Standard of Care?
Concerns regarding traditional techniques led to the development of robotic systems to facilitate the safe and accurate placement of pedicle screws. The Mazor Spine Assist was the first robotic spine surgery (RSS) platform to receive US Food and Drug Administration approval in 2004. Since then, there has been a steady increase in the application of RSS with several additional iterations of the Mazor platform and other competing systems receiving approval. As the indications, potential benefits, and utilization of RSS continue to expand, the question naturally arises as to whether RSS will eventually become the standard of care for spine surgery. In this article, we review the available evidence and experience with RSS and discuss the potential for RSS to become the medical standard of care.
- 16 June 2022
- Published by International Journal of Spine Surgery in International Journal of Spine Surgery
- Vol. 16 (S2) , S14-S21
Robotic-Assisted Revision Spine Surgery
As the surgical treatment of spinal degenerative conditions increases, more patients will ultimately require revision spine surgery. Revision spine surgery is more technically demanding than primary surgery with increased complication rates and variable clinical outcomes. The freehand placement of pedicle screws into a previously operated and/or fused level is more difficult due to the altered anatomic landmarks and/or bone loss. Additional benefit of robotic spine surgery is appreciated during such revision spine surgical procedures with unusual anatomic considerations, whereby the preoperative planning using robotic planning software and computer-assisted robotic guidance play a crucial role in assisting the surgeon to “visualize the invisible.” We highlight 3 roles of this technology in 3 cases: planning strategic osteotomies, redrilling of screw holes, and insertion of revision screws in previously operated thoracolumbar and cervical spine regions.
- 16 June 2022
- Published by International Journal of Spine Surgery in International Journal of Spine Surgery
- Vol. 16 (S2) , S14-S21
Robotic-Assisted Revision Spine Surgery
As the surgical treatment of spinal degenerative conditions increases, more patients will ultimately require revision spine surgery. Revision spine surgery is more technically demanding than primary surgery with increased complication rates and variable clinical outcomes. The freehand placement of pedicle screws into a previously operated and/or fused level is more difficult due to the altered anatomic landmarks and/or bone loss. Additional benefit of robotic spine surgery is appreciated during such revision spine surgical procedures with unusual anatomic considerations, whereby the preoperative planning using robotic planning software and computer-assisted robotic guidance play a crucial role in assisting the surgeon to “visualize the invisible.” We highlight 3 roles of this technology in 3 cases: planning strategic osteotomies, redrilling of screw holes, and insertion of revision screws in previously operated thoracolumbar and cervical spine regions.