HAHimanshu Arora

Himanshu Arora

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Himanshu Arora has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Long Term Clinical and Aesthetic Outcomes of Implants Placed With Immediate and Early Protocol in the Anterior Maxilla: A Systematic Review

    by Thomas Briggs, Himanshu Arora, Saso Ivanovski

    Objectives: The aim of this review was to assess the long‐term clinical and aesthetic outcomes of implants placed with immediate and early protocols in the anterior maxilla with a follow‐up greater than 5 years. Materials and Methods: An electronic search in Pubmed, Embase, CINAHL via EBSCO, and the Cochrane database was performed to identify studies on single‐tooth implants placed with immediate (Type 1) and early (Type 2) placement protocols in the anterior maxilla that reported outcomes on aesthetics, hard and soft tissue changes with a mean follow up ≥ 5 years. Results: Fifteen studies on immediate and early protocol single implants placed in the anterior maxilla with a ≥ 5 year follow up were included. A lack of studies comparing the two placement protocols was observed. Soft tissue changes were found to be acceptable for immediately placed implants, with seven studies reporting mean mid‐buccal gingival recession of 0.15 ± 0.27 mm and mean papillary height loss of 0.07 mm mesial and 0.20 mm distal after a follow up of ≥ 5 years. Advanced buccal recession (> 1 mm) occurred in 12.17% of cases. Ten of the 15 included studies reported a mean bone loss of 0.68 ± 0.42 mm. Favorable aesthetic outcomes were reported by most studies with a 2.83% incidence of aesthetic failures (aesthetic score < 50% of maximum achievable). The few studies that reported on patient‐centered outcomes showed a high level of patient satisfaction post treatment. Conclusions: Immediate and early implant placement protocols showed acceptable soft tissue and aesthetic outcomes, with suboptimal aesthetic outcomes reported in 2.83% of cases. More long‐term follow‐up studies are necessary to identify factors that influence aesthetic outcomes in implants placed with various placement protocols in the anterior maxilla.

  • Open Access

    Alveolar bone regeneration using a 3D‐printed patient‐specific resorbable scaffold for dental implant placement: A case report

    by Sašo Ivanovski, Reuben Staples, Himanshu Arora, Cedryck Vaquette, Jamil Alayan

    Background: This case report demonstrates the effective clinical application of a 3D‐printed, patient‐specific polycaprolactone (PCL) resorbable scaffold for staged alveolar bone augmentation.Objective: To evaluate the effectiveness of a 3D‐printed PCL scaffold in facilitating alveolar bone regeneration and subsequent dental implant placement.Materials and Methods: A 46‐year‐old man with a missing tooth (11) underwent staged alveolar bone augmentation using a patient‐specific PCL scaffold. Volumetric bone gain and implant stability were assessed. Histological analysis was conducted to evaluate new bone formation and graft integration.Results: The novel approach resulted in a volumetric bone gain of 364.69 ± 2.53 mm3, sufficient to reconstruct the original alveolar bone contour and permit dental implant placement. Histological analysis showed new bone presence and successful graft integration across all defect zones (coronal, medial, and apical), with continuous new bone formation around and between graft particles. The dental implant achieved primary stability at 35 Ncm−1, indicating the scaffold's effectiveness in promoting bone regeneration and supporting implant therapy. The post‐grafting planned implant position deviated overall by 2.4° compared with the initial restoratively driven implant plan pre‐bone augmentation surgery. The patient reported low average daily pain during the first 48 h and no pain from Day 3.Conclusions: This proof‐of‐concept underscores the potential of 3D‐printed scaffolds in personalized dental reconstruction and alveolar bone regeneration. It marks a significant step forward in integrating additive manufacturing technologies into clinical practice through a scaffold‐guided bone regeneration (SGBR) approach. The trial was registered with the Australian New Zealand Clinical Trials Registry (ACTRN12622000118707p).


  • Open Access

    The influence of metal artifact reduction on the trueness of registration of a cone‐beam computed tomography scan with an intraoral scan in the presence of severe restoration artifact

    by John Biun, Raahib Dudhia, Himanshu Arora

    Purpose: When planning guided implant surgery, highly radiopaque materials such as metals or zirconia produce streaking artifacts (‘metal artifact’) on cone‐beam computed tomography scans, which can impair registration of the intraoral scan. This study aimed to determine the effect of metal artifact reduction on the trueness of registration in the presence of multiple full‐coverage zirconia crowns.Materials and methods: A 3D‐printed maxillary study model was restored with 12 full‐coverage zirconia crowns and scanned with an intraoral scanner. Cone‐beam computed tomography scans of the study model were acquired, with and without activation of the metal artifact reduction algorithm. Registration of the optical scans was performed using initial point‐based registration with surface‐based refinement, and the deviation was measured at four pre‐defined dental landmarks. Welch's t‐test was used to compare the registration error for the metal artifact reduction group with the control group.Results: The average registration error was 0.519 mm (95% CI 0.507 to 0.531) with metal artifact reduction deactivated, compared to 0.478 mm (95% CI 0.460 to 0.496) without metal artifact reduction. Therefore, activation of the metal artifact reduction algorithm was associated with a 0.041 mm (95% CI 0.020 to 0.061, p < 0.001) increase in average registration error.Conclusions: The use of the metal artifact reduction algorithm slightly reduced trueness in this in vitro study. Clinicians are advised not to rely on a metal artifact reduction (MAR) algorithm for registration of a cone‐beam computed tomography scan with an intraoral scan when planning guided implant surgery in the presence of restoration artifacts.


  • Open Access

    The in‐vitro accuracy of fiducial marker‐based versus markerless registration of an intraoral scan with a cone‐beam computed tomography scan in the presence of restoration artifact

    by John Biun, Raahib Dudhia, Himanshu Arora

    Objectives: To determine the effect of restoration artifact (‘metal artifact’) on registration accuracy of an intraoral scan and cone‐beam computed tomography (CBCT) scan, comparing fiducial marker‐based registration with markerless registration.Materials and methods: A maxillary model was fitted with multiple configurations of zirconia crowns to simulate various states of oral rehabilitation. Intraoral scans and CBCT scans (half and full rotation) were acquired. Registration was performed using markerless (point‐based registration with surface‐based refinement) and fiducial marker‐based registration. Each experimental condition was repeated 10 times (n = 320). The absolute deviation was measured at the canines and first molars, and the average and maximum values were analysed using multiple linear regression.Results: R2 was 0.874 for average error and 0.858 for maximum error. For markerless registration, there were 0.041 mm (p < .001) and 0.045 mm (p < .001) increases in average and maximum error per crown, respectively. For fiducial marker‐based registration, the effect of additional crowns was not statistically significant for average (p = .067) or maximum (p = .438) error. For a full arch of crowns, the regression model predicted average and maximum errors of 0.581 and 0.697 mm for the markerless technique, and 0.185 and 0.210 mm for the fiducial marker‐based technique. Overall, the fiducial marker‐based technique was more accurate for four or more crowns. The half rotation scan increased average error by 0.021 mm (p = .001) and maximum error by 0.029 mm (p < .001).Conclusions: Under the present study's experimental conditions, the fiducial marker‐based technique should be considered if four or more full‐coverage highly radiopaque restorations are present.


  • Open Access

    Ten Year Clinical and Aesthetic Outcomes of an Immediately Placed and Restored Implant in the Anterior Maxilla: A Case Report

    by Himanshu Arora, Sašo Ivanovski

    The nature of immediate implant placement followed by an immediate restoration protocol makes it particularly suited to the anterior maxilla. In addition to saving treatment time and avoiding additional surgical procedures, this protocol has been reported to improve aesthetic outcomes by supporting the peri-implant tissues during the implant healing phase through the use of a provisional restoration. This case report documents the use of this protocol in a patient with a failing maxillary anterior tooth and reports on the soft and hard tissue changes over an observation period of 10 years. An implant was immediately placed after removal of a failing maxillary central incisor followed by the provision of a screw retained provisional crown on the same day. A definitive restoration was placed after a 3-month healing period. Not only did this protocol manage to maintain peri-implant bone levels over the 10-year follow-up period, excellent aesthetic outcomes and very limited soft tissue recession were observed with the use of this technique.


  • Open Access

    Mini-Implant-Retained Overdentures for the Rehabilitation of Completely Edentulous Maxillae: A Systematic Review and Meta-Analysis

    by Serena Vi, Damon Pham, Yu Yian Marina Du, Himanshu Arora, Santosh Kumar Tadakamadla

    Purpose: Mini-dental implants (MDIs) have been used to support and retain overdentures, providing patients with a less invasive placement procedure. Although lucrative, the use of MDIs to retain a maxillary overdenture is still not an established treatment modality. This systematic review aims to answer the question: Do mini-implant-retained maxillary overdentures provide a satisfactory treatment outcome for complete edentulism? Methods: A systematic search for relevant articles was conducted to include articles published until April 2021 in the following electronic databases: CINAHL, Cochrane, EMBASE, PubMed, and Web of Science. All empirical studies evaluating the biological, survival, or patient-reported outcomes after placing mini-implant-retained overdentures in maxilla were considered for inclusion. The risk of bias was assessed by utilizing the Joanna Briggs Institute critical appraisal checklist. Study screening and data extraction were conducted by three reviewers independently. Results: The electronic search retrieved 1276 titles after omitting duplicates. Twenty articles were considered for full-text review, of which six studies were included in this systematic review. The included studies evaluated a total of 173 participants with a mean age of 66.3 years. The overall mini-implant survival rate was 77.1% (95% CI: 64.7–89.5%) with a mean follow-up time of 1.79 years (range: 6 months to 3 years). Implant survival differed significantly when comparing complete and partial palatal coverage overdentures. Those with complete palatal coverage exhibited less bone loss overall compared to partial coverage overdentures. Participants of all studies reported an increase in the quality of life and in satisfaction after rehabilitation treatment with MDIs. Conclusions: The survival rate of mini-implants retaining an overdenture in the maxilla was observed to be lower than the values reported for traditional implants in the literature. Improvements were observed in all aspects in terms of patient satisfaction, quality of life, oromyofunction, and articulation after the treatment.


  • Open Access

    Evaluating the effectiveness of nonsteroidal anti‐inflammatory drug(s) for relief of pain associated with temporomandibular joint disorders: A systematic review

    by Sachin Kulkarni, Samuel Thambar, Himanshu Arora

    Aim: The aim of this systematic review was to compile the latest evidence to assess the effectiveness of nonsteroidal anti‐inflammatory drug(s) (NSAID) in patients with temporomandibular joint disorders (TMDs) in relieving pain. TMDs are a group of musculoskeletal disorders that affect the temporomandibular joint and/or masticatory muscles.Methods: After a literature review, a comprehensive search was conducted via Pubmed, Scopus, Google Scholar, and Cochrane databases with a systematic search strategy. The inclusion criteria were randomised controlled trials in humans, published in the last 50 years evaluating the effect of NSAIDs on TMDs. Although this duration chosen would potentially identify studies that have utilised outdated treatments, research methodology, and TMDs diagnostic criteria, and this has been considered before making clinical recommendation, it was used to advise future methodological changes necessary. The included studies were subjected to full‐text review.Results: Out of 646 studies initially identified through searches, 12 were selected for full‐text review of which 11 were included in the data synthesis. All 11 studies were randomised controlled trials. In total, 424 patients were included in this review. The earliest study included was 1996. Diagnostic criteria varied among all studies, and some did not specify enough signs and symptoms to construct a diagnosis. Intervention varied among all studies, as did the control. Nonspecific diagnosis, variable control groups, and heterogenous intervention protocols affected the outcome of this review. Despite the reduction of pain in the joint and/or masticatory muscles as well as improved range of motion, conclusive clinical recommendation could not be made.Conclusion: Heterogeneity did not allow for definitive conclusion; however, there was some evidence to support the use of NSAIDs in patients with TMDs for relief of pain. Further studies with strict, consistent diagnostic criteria and treatment are required.


  • Immediate and early implant placement in single‐tooth gaps in the anterior maxilla: A prospective study on ridge dimensional, clinical, and aesthetic changes

    by Himanshu Arora, Saso Ivanovski

    Objectives: This prospective study evaluated the impact of timing of placement (immediate and early) on the horizontal ridge dimensional changes, clinical, and aesthetic outcomes of implants placed in single‐tooth gaps in the anterior maxilla.Materials and methods: Implants were placed in single‐tooth gaps in the anterior maxilla of 30 patients, either immediately after extraction (Group A, n = 15) or after a healing period of 4–8 weeks (Group B, n = 15). In both groups, implant placement was followed by a 3‐ to 4‐month period of non‐submerged healing, after which definitive crowns were placed. Study models were obtained before extraction (T0), at implant placement (T1), at the insertion of a definitive crown (T2), and 1‐year thereafter (T3). Horizontal ridge dimensional changes were measured by superimposing the optical scans of the study models from different time‐points. Radiographs and photographs were used to evaluate changes in marginal bone levels and soft tissue recession. Aesthetic evaluation was carried out using the Pink and White Esthetic Score (PES and WES) indices. Patient‐reported outcomes were measured using a subjective questionnaire.Results: A 100% implant survival rate was observed in both groups after a 1‐year follow‐up. Analysis showed a labial horizontal tissue dimensional change of 0.61 mm and 0.72 mm from T0 to T3 in Groups A and B, respectively. Acceptable PES values were observed in both groups (Group A: 9.40; Group B: 9.27) after the 1‐year follow‐up period. No incidence of advanced mucosal recession was observed between definitive crown insertion and 1‐year follow‐up in both groups. No significant changes were observed for all other measured variables at different time‐points.Conclusions: Immediate and early placed implants in single‐tooth gaps in the anterior maxilla showed similar ridge dimensional changes as well as acceptable clinical, aesthetic, and patient‐centred outcomes in the short‐term (1‐year follow‐up).


  • Evaluation of the influence of implant placement timing on the esthetic outcomes of single tooth implant treatment in the anterior maxilla: A retrospective study

    by Himanshu Arora, Saso Ivanovski

    Objectives: The purpose of this retrospective study was to investigate the influence of implant placement timing on the esthetic outcomes for single implants in the anterior maxilla.Materials and methods: One hundred and ten patients (48 males; 62 females) who received a single‐tooth implant after extraction either immediately (Type 1); after 4–8 weeks (Type 2); after 8–16 weeks (Type 3); or more than 16 weeks (Type 4) were evaluated in terms of esthetic outcomes after a mean post‐placement interval of 26.3 months (range 12–116). Esthetic outcomes were measured using the Pink and White Esthetic Score (PES; WES). Stepwise regression analysis was performed to analyze the effect of timing of placement, as well as patient demographics and other clinical parameters on the esthetic outcomes.Results: No statistically significantly differences in PES were found between the various treatment modalities with Type 1 implants (n = 33) scoring 10.58 ± 1.65 (median: 11), followed by 10.36 ± 2.09 (median: 10.5), 9.68 ± 2.43 (median: 10), and 9.63 ± 2.21 (median: 10) for Type 2 (n = 14), Type 3 (n = 19), and Type 4 (n = 44), respectively. For immediate implants, a trend towards better esthetic outcomes was observed when implant placement was done flaplessly in cases with intact buccal bone (Type 1A, median PES 11) as compared to cases with partial/complete missing buccal plates where a flap was raised (Type 1B, median PES 10). Overall, the only parameter that influenced esthetic outcomes (as measured by PES) was gender, with females having significantly superior results. The median WES was 8 and 96% of the crowns were deemed esthetically acceptable, with crowns placed by specialist prosthodontists yielding higher scores than those placed by general practitioners.Conclusions: Single tooth implants in the anterior maxilla showed satisfactory outcomes when measured with objective esthetic criteria. Timing of implant placement did not significantly influence the esthetic outcomes, although a trend towards better outcomes was seen with immediate implant placement as observed by higher median PES values.CLINICAL SIGNIFICANCE: Single tooth implant placement in the anterior maxilla is a predictable treatment modality for achieving acceptable esthetic outcomes regardless of the timing of placement.